| 1 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 2 | Glazed vitrified floor tiles polished finish of size |
| 3 | Size of Tile 600 x 1200 mm |
| 4 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in- harge. |
| 5 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading,transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved |
| 7 | Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level : |
| 8 | 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size |
| 9 | P/F of stainless steel finish locks OPL-1 of ozone/drona or equivalent for toughened glass fixed in bottom/ centre of the door complete in all respect and to the entire satisfaction of engineer in charge. |
| 10 | Providing and fixing steel tublar type handle set 32mm dia, 450mm long with stainless steel screws etc. complete in all respect to the entire satisfaction of engineer in charge. |
| 11 | Providing and fixing 12 mm thick fix toughened glass of approved brand and manufacture,and fixed with necessary fixutres of SS and SS screws,angles etc to the entire sarisfaction of engineer in charge. |
| 12 | Providing and fixing 8 mm thick fix toughened glass of approved brand and manufacture,and fixed in the existing window frame with necessary fixtuers etc to the entire satisfaction of engineer in charge. |
| 13 | Providing and fixing of Hydroulic floor spring of approved brand (Hardwyn/Ozone) for doors including cost of cutting floors, embedded in floors as required and making good the same eith cover plates with brass pivet complete in all respect, |
| 14 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 15 | For fixed portion |
| 16 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 17 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 18 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 19 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 20 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 21 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 22 | Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side |
| 23 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 24 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 25 | 300x10 mm |
| 26 | 250x10mm |
| 27 | 200x10 mm |
| 28 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 29 | 125 mm |
| 30 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 31 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 32 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 33 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 34 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 35 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 36 | Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 37 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 38 | Hot finished welded type tubes |
| 39 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 40 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) |
| 41 | Providing and fixing of polycarbonate sheet of approved colour and size complete in all respect including silicon strips on edges and aluminium section as requited as per the approval of engineer in charge. |
| 42 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 43 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 44 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 45 | Group C |
| 46 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 47 | Group C |
| 48 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 49 | 3 x 1.5 sq. mm |
| 50 | 3 x 2.5 sq. mm |
| 51 | 3 x 4 sq. mm |
| 52 | 3 x 6 sq. mm |
| 53 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 54 | 20 mm |
| 55 | 25 mm |
| 56 | Supply,erection,testing and commissioning of ceiling fans 1400mm sweep One star rating white color with copper winding but without regulator complete with aluminium blades, plastic canoples 2 nos, double ball bearing, MS hanging rods, etc. complete in all respect. The job includes Installation, testing and commissioning of ceiling fan, including wiring with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required upto adjacent light point complete in all resepect.Makes Havells-Velocity ES/Orient- Summer-Breeze Pro /Crompton-High Speed/Bajaj- SABSE TEZZ-EE only |
| 57 | Supply and erection of fan rod made of seemless MS pipe dia duly powder coated complete in all respect. Make National |
| 58 | 24\" leght |
| 59 | 30\" length |
| 60 | Supply ,installation, testing and commissioning of recessed type down lighter 15 watt of 4000K/5700K/6500K (as approved by engineer in charge) having synthetic/powder coated pressure diecast alulminium body having high efficiency diffuser with more than 85% transmittance with rated life of L-70 @50,000 hours having system lumens more than 1200 lumensand efficacy better than 110 lumens/watt with CRI >80 and drivers efficiency >85% , THD less than 10% with inbuilt surge protection minimum 2.5 KV. The job includes fixing down lighter and connection with 3x1.5sqmm copper wire upto 1.5mtr length from adjacent light point with all petty material and labour required to complete the job in all respect. Please Enable Macros to View BoQ information |