| 1 | Earth work in excavation by meachanical means(Hydraulic excavator)/manual means over ares (exceeding 30cm in depth 1.5 m in width as well as 10 sqm on plan) including getting out and dispaosal of excavated earth, lead upto 50 m and lift upto 1.5 m as directed by the Engineer-in-Charge. 2.6.1 All kinds of soil. |
| 2 | Filling in available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layer not exceeding 20 cm in depth consolidating each deposited layer by ramming and watering lead upto 50 m and lift upto 1.5 m. |
| 3 | Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating and dressing complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level: 4.1.6 1:4:8(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size. |
| 5 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pazzolana/Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads\" but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete. All works upto plinth level. Concrete of M-25 grade with minimum cement concrete of 330kg/cum. |
| 6 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pazzolana/Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate/retard setting of concrete to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads\" but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete. All works above plinth level upto floor V level. Concrete of M-25 grade with minimum cement concrete of 330kg/cum. |
| 7 | Reinforced cement concrete work in beams, suspended floors, roof shaving slope upto 15 deg., landings, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 8 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 9 | Applying a coat of residual petroleum bitumen of grade VG-10 of proved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 10 | Reinfocement for R.C.C works including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars. |
| 11 | Reinfocement for R.C.C works including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars. |
| 12 | Brick work with 1st class common burnt clay F.P.S (non-modular) bricks in foundation and plinth inCement mortar 1:4 (1 cement : 4 coarse sand) |
| 13 | Half brick masonry with 1st class common burnt clay F.P.S (non-modular) bricks in superstructure above plinth lavel upto floor five level inCement mortar 1:4 (1 cement : 4 coarse sand). |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts. |
| 16 | 52 mm thick cement concrete flooring with cement hardener topping layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate 6 mm nominal size) by volume hardening compound is mixed @ 2 litre per 50 kg of cement or as per manufacturers specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 17 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid separately. Local best quality Tolhao wood. |
| 18 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S, butt hinges bright finished of required size and necessary screws. Local best quality Tolhao wood30 mm thick. |
| 19 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 300 x 16 mm |
| 20 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: 250 x 10 mm |
| 21 | Providing and fixing chromium plated brass handles with necessary screws etc. complete. 125 mm |
| 22 | Providing 40 x 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 3010 x 15 cm. 1:3:6 mix(1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 23 | Steel work in built up tubular (round, square or rectangular tubes etc. including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. Hot finished welded type tubes. |
| 24 | Providing and fixing precoated galvinised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied 1 in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5 x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussess and including cutting to size and shape wherever required with Precoated galvanised iron profile sheets 0.35 mm thick. |
| 25 | Providing and fixing precoated steel sheet roofing accessories, Zinc coating 120 gm as per IS:277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I seam bolts and nuts, G.I plain ad bitumen washers complete : Ridge plain (500-600 mm) |
| 26 | Precoated glavanised iron profile sheets 0.35 mm thick |
| 27 | Gutter (600 mm over all girth). Precoated galvanised iron profile sheets 0.35 mm thick. |
| 28 | Providing and fixing on wall unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm diameter. |
| 29 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia. M/S bar bent to shape with hooked ends in R.C.C slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. |
| 30 | INTERNAL WATER SUPPY AND SANITAY INSTALLATION |
| 31 | Providing and fixing water closet squatting pan Iindian type W.C pan) with 100 mm sand cast iron P or Starp, 10 litre low level white I.P V.C flushing cistern, including flush pipe, with manually controlled devide (handle lever) conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C pan of size 580 x 440 mm with integral type foot rests. |
| 32 | Proving and fixing stainless steel A ISI 304(18/8) kitchen sink s per IS:13983 with C.I brackets and stainless steel plug 40 mm including oainting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610 x 460 mm bowl depth 200 mm. |
| 33 | Providing and fixing wash basin with C.I brackets, 15 mm C.P brass pillar taps, 32 mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China flat back wash basin size 450 x 300 mm with single 15 mm C.P brass pillar tap. |
| 34 | Providing and fixing PTMP Waste Coupling for wash basin and sink, of approved quality and colour, Waste Coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms. |
| 35 | Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete. Flexible pipe 40 mm dia. |
| 36 | Providing and fixing 600 x 450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P brass screws and washer complete. |
| 37 | Providing and fixing PTMP liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 38 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge. 25 mm nominal outer dia Pipes. |
| 39 | Providing and fixing on terrace (at all floor levels) polyethylene water storage tabk IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 40 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25 mm nominal bore, weighing not less than 62 gms. |
| 41 | Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying coat of 1 approved steel primer all complete. |
| 42 | Vertical [ISMC 49.5 x 49.5 x 4.5]:[4 x 4 = 16 m @ 5.95kg/m] |
| 43 | Horizontal [ISMC 38 x 38 x 4.0]:[14 x 1.52 = 21.28 m@ 3.95 kg/m] |
| 44 | Ready made Septic Tank |
| 45 | INTERNAL ELECTRICAL INSTALLATION |
| 46 | 6A Socket |
| 47 | 16 A Socket |
| 48 | 16 A Switch |
| 49 | 12 way metal box |
| 50 | 12 way modular plate |
| 51 | 6W Metal Box |
| 52 | 6W Modular Plate |
| 53 | Fan Regulator switch type |
| 54 | Surface Light |
| 55 | 6A switch |
| 56 | Fan Box |
| 57 | Deep JB 4 way |
| 58 | Conduit pipe 25 mm |
| 59 | Wire 1.5 sqmm Red |
| 60 | Wire 1.5 sqmm Blue |
| 61 | Wire 1.5 sqmm Green |
| 62 | Wire 2.5 sqmm |
| 63 | Wire 4 Sqmm Red |
| 64 | Wire 4 Sqmm Blue |
| 65 | Wire 4 Sqmm Green |