| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 2 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 3 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 4 | Of area 3 sq. metres and below |
| 5 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 6 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite)soliddoor/window/Clerestorywindows&otherFrames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywithpropertyofbeingtermite/borerproof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 7 | Frame size 65 x 100 mm |
| 8 | Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle boardIS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type ll exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). |
| 9 | 25 mm thick |
| 10 | Providing and fixing factory made single extruded WPC window shutters, fixing with 100 mm stainless steel butt hinges including 4mm thick float glass panes etc all complete as per the direction of Engineer-in-charge. |
| 11 | 30 mm thick WPC |
| 12 | Cement concrete flooring 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 13 | 40 mm thick with 20 mm nominal size stone aggregate |
| 14 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 15 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 16 | Re-fixing M.S grills of required pattern in framesof windows etc .with M.S flats square of round bars etc. including priming coat with approved steel primer all complete. |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 18 | Two or more coats on new work |
| 19 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approvedbrandandmanufacture,includingapplyingadditionalcoats wherever required to achieve even shade and colour. |
| 20 | Two coats |
| 21 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 22 | Old work (Two or more coats applied @ 1.43 V/ 10 sqm) over existing cement paint surface |
| 23 | White washing with lime to give an even shade: |
| 24 | New work (three or more coats) |
| 25 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 26 | 300x16 mm |
| 27 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 28 | 100x10 mm |
| 29 | 200x10 mm |
| 30 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 31 | 125 mm |
| 32 | 100 mm |
| 33 | Providing and fixing in position eaves or facia board with 18 mm thick 30 cm wide WPC solid board including fixing with nuts & bolts etc. all complete as per the direction of Engineer-in-charge. |
| 34 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 35 | Twin rubber stopper |
| 36 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 37 | Providing and fixing 4 mm dia. G.I. wire adjusting hangers (upto 3000mm length), fixed to roof truss by tieing at both ends, complete as per direction of Engineer-in-charge. |
| 38 | Providingand fixingplainmultipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 39 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 40 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type orof approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 41 | 75 mm average thickness |
| 42 | 50 mm average thickness |
| 43 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust freesteel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 44 | Bars above 12 mm diameter |
| 45 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 46 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 47 | Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] with specified average thickness.Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete and appropriate approved Super-Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument) |
| 48 | 75 mm thick in Grade M25 with cement content not less than 330 kg per cum |
| 49 | 50 mm thick in Grade M25 with cement content not less than 330 kg per cum |
| 50 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as perspecifications and direction of Engineer- In-charge complete in all respect. |
| 51 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 52 | Providing and fixing uPVC Gutter (160mm x 160mm) including allnecessary accessories as per the direction of the Engineer-in-charge all complete. |
| 53 | Providing and fixing unplasticised - PVC pipes for sanitation work conforming to IS : 13592 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (i) Single socketed pipes. |
| 54 | 75 mm dia UPVC pipe |
| 55 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 56 | Coupler75 mm |
| 57 | Providing and fixing aluminium hooks and eyes : |
| 58 | 150 mm |
| 59 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 60 | Superior Hard Wood Cat-II (A) |
| 61 | Providing and fixing 35mm thick panelled, glazed or panelled & glazed shutters for door including MS Butt hinges with necessary screws with superior hardwood Cat-II (A) including panelling with 12mm thick Plywood (BWR) conforming relevant specification complete with wooden cleats & blocks as directed by Engineer in charge. |
| 62 | Providing and fixing 35mm thick glazed shutter for window with superior hard wood cat-II (A) using 10 Kg/Sqm 4mm thick glass and stainless steel butt hinges and screws including the cost of panellingas per the direction of Engineer-in-charge. |
| 63 | Superior hardwood Cat-II (A) |
| 64 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 65 | Of sectional area 40 square centimetres and above |
| 66 | Providing wood work in wrought framed and fixed in position in roof trusses, purlins, rafters, ties etc complete with: |
| 67 | Superior Hard Wood Cat-II (A) |
| 68 | Painttingwithoiltypewoodpreservativeofapprovedbrandand manufacture: |
| 69 | New work (two or more coats) |
| 70 | Re-fixing of existing precoated galvanised iron profile sheets by using self drilling/self tapping screws of size (5.5x55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces as per the direction of Engineer-in-charge. |
| 71 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equalavent(size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling / self tapping aluminium screws (Xylan) of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 72 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equalavent(size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns usning self drilling/self tapping screws complete.Ridges plain (500-600mm) |
| 73 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 74 | 1:3:6 (1Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 75 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 76 | Lintels,beams,plinthbeams,girders,bressumersand cantilevers |
| 77 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 78 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 79 | Providing and laying vitrified floor tiles in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 80 | Size of tiles 1200 x 300 mm |
| 81 | Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 82 | Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |