| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable insurface /recessedmediumclassPVCconduit,withmodular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group B |
| 3 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cablein surface/ recessedmedium class PVC conduit alongwith 1No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesofFRLSPVCinsulatedcopper conductor,single corecableinsurface/recessedmediumclassPVCconduitas required. |
| 5 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 6 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 7 | Supplyingand drawingfollowingpair 0.5mmdiaFRLSPVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 8 | 1 Pair |
| 9 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductorPEinsulated,shieldedwithfinetinnedcopper braidandprotectedwithPVCsheathintheexistingsurface/ recessed steel/ PVC conduit as required. |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 11 | 20mm |
| 12 | Supplying and fixing following modular switch/ socket on the existing modularplate&switchboxincludingconnectionsbutexcluding modular plate etc. as required. |
| 13 | Telephone socket outlet |
| 14 | TV antenna socket outlet |
| 15 | Supplyingand fixingtwo module steppedtypeelectronicfan regulatorontheexistingmodularplateswitch boxincluding connections but excluding modular plate etc. as required. |
| 16 | Supplying and fixing suitable size GI box withmodular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6Amodularsocketoutlet and 5/6Amodularswitch, connections etc. as required. |
| 17 | Supplying and fixing suitable size GI box withmodular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 &15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 18 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 19 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 20 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connectionsetc. as required. |
| 21 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 22 | Installation,testingandcommissioningofpre-wired,fluorescent fitting / compact fluorescent fittingof alltypes,complete withall accessoriesand tube/lamp etc.directly on ceiling/ wall,including connectionswith 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 23 | Installation,testingandcommissioningofceilingfan,including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 24 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socketoutletand 25 A modularSPMCB,\"C\"curveincluding connections, painting etc. as required. |
| 25 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 26 | 12 way , Double door |
| 27 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles intheexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. |
| 28 | Single pole |
| 29 | Supplying and fixing following rating, double pole, 240 V, isolator in theexistingMOBDBcompletewithconnections,testingand commissioning etc. as required. |
| 30 | 40A |
| 31 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories,andprovidingmasonryenclosurewithcoverplate havinglockingarrangementandwateringpipeetc. (butwithout charcoal/ coke and salt ) as required. |
| 32 | Providing and laying earth connection from earth electrode with 6 SWG diaG.I.Wirein15 mm diaG.I.pipe fromearthelectrode including connection withG.I. thimble excavation andre-filling as required. |
| 33 | Providing and fixing 6 SWG dia GI. wire on surface or in recess for loop earthing as required. |
| 34 | Supplying of BLDC 5 - STAR AC ceiling fan 1200mm sweep (W/O Remote) Make-Crompton BLDC BEE 5- STAR 1200mm ENERGION Riviera or similar in Make- Usha/Anchor/Bajaj/orient etc complete with all accessories etc as required. |
| 35 | Supplying of prewired LED tube lamp fittting 20 W Essential Bright Batten similar to make Philips Cat BN 170C LED20S-6500 SU L120 or similar in make Havels, Syska, Bajaj, Crompton. etc as required and directed in Engineer-in- charge. |
| 36 | Supplying, Installation, Testing and Commissioning of LED Bulkhead fitting 10W Similar to Havells, HEXA 10W Cat No. HEXAFT 10W LED 857SSYMBOPC or similar in Bajaj, philips, Crompton etc as suitable for indoor and outdoor application as required and directed by Engineer- in -Charge. |
| 37 | Supplying of LED bulb similar to Make Havells LED bulb 9watt B22CDL odering code LHLDDDEBIASR009, 880 LUMEN hsn CODE 85395200. |