| 1 | M & L for Servicing and repair of cast iron, double flange, butterfly valve of P.N.16 Rating. Of following sizes including replacement of nut & bolts, gaskets etccomplete all as specifiedf and as directed. |
| 2 | (a) 80mm NB |
| 3 | (b) 100mm NB |
| 4 | (c) 150mm NB |
| 5 | Supply and Installation in replacement of cast iron, double flanged, butterfly valve of P.N.16 Rating. Of following sizes complete all as specifiedf and as directed. |
| 6 | (a) 80mm NB |
| 7 | (b) 100mm NB |
| 8 | (c) 150mm NB |
| 9 | M & L for Servicing and repair of double flange NRV of P.N.16 Rating. Of following sizes including replacement of nuts & Bolts, gaskets etc complete all as specifiedf and as directed. |
| 10 | (a) 80mm NB |
| 11 | (b) 150mm NB |
| 12 | Supplying and installing in replacement of double flange NRV of P.N.16 Rating. Of following sizes complete all as specifiedf and as directed. |
| 13 | (a) 80mm NB |
| 14 | (b) 150mm NB |
| 15 | Supplying and installing in replacement of strainer of P.N.16 Rating of following sizes complete all as specifiedf and as directed. |
| 16 | (a)100 mm NB |
| 17 | (b) 150 mm NB |
| 18 | Supplying and installing in replacement of pressure gauge of 100 mm dia., 0-300 PSI or 0-21 kg/sq.cm fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow, etc. as per requirement as specified and directed by Engineer-in-charge. |
| 19 | Supplying and installing in replacement of pressure switch with 12/15 mm dia. Isolation valve, G.I. nipple, elbow, etc. as per site requirement as specified and directed by Engineer-in-charge. |
| 20 | Supplying and installing in replacement of 63mm gun metal single outlet hydrant valve fitted with necessary accessories complete all as directed by Engineer-in-charge. |
| 21 | Servicing and repairing 63mm gun metal single outlet hydrant valve including replacement of neceessary accessories complete as directed by Engineer-in-charge. |
| 22 | Supplying fire fighting R.R.L. Hose pipe 63 mm dia, 15m in length, fitted with necessary accessories complete all as directed by Engineer-in-charge. |
| 23 | Hose binding with GI Wire fire fighting R.R.L. Hose pipe 63 mm dia, 15m in length,complete all as directed by Engineer-in-charge. |
| 24 | S & F in replacement indoor type lockable hose cabinet made of 18 gauge MS sheet of size 800 mm X 600 mm X 250 mm with double door with 4 mm thick glass and door frame made of 16 gauge MS sheet painted two coats of fire red outside and brilliant white inside over a coat of primer suitable to house two sets of hose RRL hose and gunmetal branch pipe all complete as specified and directed.. |
| 25 | Supplying and Installing in replacement wall mounting swinging Hose reel drum fitted with 19 mm dia. 36 meter high pressure polypropylene (Polyhose) hose pipe long fitted with necessary accessories complete all as specified and directed by Engr-in-Charge. |
| 26 | Servicing and repairing of wall mounting swinging Hose reel drum fitted with upto 25 mm dia hose pipe including replacement of rusted nuts and bolts, fixing with anchor fastners cleaning and greasing etc all as directed by Engineer-in-charge. |
| 27 | Supplying & fixing in replacement G.M. branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle. |
| 28 | Supplying & installing gun metal ball valve of size 25 mm dia. of P.N.16 Rating.complete as specified and as directed. |
| 29 | Supplying & installing gun metal air release valve of size 25 mm dia.,of P.N.16 Rating complete as specified and as directed. |
| 30 | Servicing ,of Two way Breaching inlet valve with male instantaneous inlet with cap & chain complete as specified and as directed. |
| 31 | Supplying, Installation,Testing , Programming and commissioning in replacement of addressable type multi sensor detector with heat & smoke combination complete as specified and as directed. |
| 32 | Supplying, erecting, Programming ,testing and commissioningManual Call Point (Pill box) with break glass push button in metal enclosure complete all as directed by Engineer-in-charge. |
| 33 | Supply, Installation in replacement of addressible electronic sounder cum strobe Hooter including connecting and programming with existing fire alarm panel complete as directed by Engineer-in-charge. |
| 34 | Supply, installation,Programming & commissioning in replacement of 2 loopFire Alarm Panel 230V AC, standby battery & battery charger Provision To Connectdetectors like smoke detectors , Heat Detectors Withstd. facilities as directedby Engineer-in-charge. |
| 35 | Servicing and cleaning of Fire/Smoke detectors of highrise buildings upto G+9 configuration including replacement of control supply connector terminals if required all as directed by Engineer-in-charge. |
| 36 | M&L for Disconnecting booster pump motor power cables of various sizes from electrical motor of different capacities and decoupling from thepump sets, removing and taking down carefully and transporting to authorised/reputed workshop, Dismantaling stator and rotor carefully and rewinding stator assembly with supper enamelled copper winding wire of suitable gauge matching to existing gauge and cleaning of slots, core with carbon tetra chloride solution and applying two coats of insulation varnish and keep stator assembly in heating chamber to improve insulation strength, reassemble motor completey and transporting back to site, coupling pump to motor and check for proper shaft alignments such that no vibrations produced during opertion, connecting power cables to motor including replacement of any unserviceable nuts and bolts of any size and testing of following capacity booster pump set motors |
| 37 | Pump set motor capacity 7.5 HP complete. |
| 38 | Pump set motor capacity 12.5 HP complete. |
| 39 | M & L for removing existing Booster pump set motor from base frame after disconnecting electrical connections and replacing bearings for pump or motor, grinding the shaft or replacing the shaft, replacment of coupling, replacement of mechanical seal, replacing C.I impeller etc complete and re-assembling and fixingback to original positionand checking for proper shaft alignments such that no vibrations produced during opertion complete testing all as directed by engineer-in-charge for the following capacity of pumps and motors:- Notes :-(a) The cost of bearings, shafts, coupling sets, Mechanical seal, gland bush plates, C.I impeller etc will be measured & paid separately under relevant schedule as supply only item .(b) The quoted rate deemed to be include cost of labour for above work along with any minor part like nuts and bolts, gland packing, lathe works if any required etc as per work/job requirement. |
| 40 | Pump set motor capacity 7.5 HP complete. |
| 41 | Pump set motor capacity 12.5 HP complete. |
| 42 | Supply only coupling set with all connected accessories for the following capacity pumping set |
| 43 | Pump set motor capacity 7.5 HP complete. |
| 44 | Pump set motor capacity 12.5 HP complete. |
| 45 | Supply only stainless steel Ball bearing of existing/ suitable size for the following size pumping setcomplete all as specified & as directed. |
| 46 | Pump set motor capacity 7.5 HP complete. |
| 47 | Pump set motor capacity 12.5 HP complete. |
| 48 | Supply only Mechanical seal of existing/ suitable size for the following size pumping setcomplete all as specified & as directed. |
| 49 | Pump set motor capacity 7.5 HP complete. |
| 50 | Pump set motor capacity 12.5 HP complete. |
| 51 | M & L for painting of fire fighting pipe line and connected valves as per existing colour fitted in each G+9 building ground floor to fire fighting terrace tank of KIRTI ENCLAVEwith synthetic enamel paint after scrapping old surface and applying red oxide primer of two coats all as directed by Engineer-in-charge. |
| 52 | M & L for painting of fire fighting pipe line and connected valves as per existing colour fitted in each G+9 building ground floor to fire fighting terrace tank ofTRISHUL ENCLAVE with synthetic enamel paint after scrapping old surface and applying red oxide primer of two coats all as directed by Engineer-in-charge. |
| 53 | M & L for painting of fire fighting pipe line and connected valves as per existing colour fitted in each G+10 building ground floor to fire fighting terrace tank of PRAKASH & SHAJIMON Buildings with synthetic enamel paint after scrapping old surface and applying red oxide primer of two coats all as directed by Engineer-in-charge. |
| 54 | M & L for painting of fire fighting pipe line and connected valves as per existing colour fitted in each G+8 building ground floor to fire fighting terrace tank of ACHARYA with synthetic enamel paint after scrapping old surface and applying red oxide primer of two coats all as directed by Engineer-in-charge. |
| 55 | M & L for painting of fire fighting pipe line and connected valves as per existing colour fitted in ecah G+5 building ground floor to fire fighting terrace tank of RAKSH & PRATIRAKSHA with synthetic enamel paint after scrapping old surface and applying red oxide primer of two coats all as directed by Engineer-in-charge. |
| 56 | M & L for painting of fire hydrant pipe line along with connected valves existing over area including firehose cabinets at TRISHUL ENCLAVE as per existing colour at ground level with synthetic enamel paint after scrapping old surface and applying red oxide primer of two coats all as directed by Engineer-in-charge. |
| 57 | M & L for painting of fire hydrant pipe line along with connected valves existing over area including firehose cabinets at KIRTI ENCLAVE as per existing colour at ground level with synthetic enamel paint after scrapping old surface and applying red oxide primer of two coats all as directed by Engineer-in-charge. |
| 58 | M & L for painting of fire hydrant pipe line along with connected valves existing over area including firehose cabinets at PRAKASH SHAJIMON buildings area as per existing colour at ground level with synthetic enamel paint after scrapping old surface and applying red oxide primer of two coats all as directed by Engineer-in-charge. |
| 59 | Providing services for welding/ jointing of GI/MS pipe of any size for any alteration or arrest leakage by using electric arc welding, replacing of hinges for firehose cabinets and connected welding works including all necessary patch material including necessary excavation and refilling of spoil complete all as specified and directed. |