| 1 | Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying cables/poles foundation/stay assembly, etc. n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed |
| 2 | M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) asin foundation, filling and mass concrete complete all as specified and directed |
| 3 | M&L for old size brickwork with fly ash bricks straight or curved on plan exc 6m mean radius wall built in cement mortar 1:6 complete all as specified and directed |
| 4 | M&L for RCC (1:1½:3) type A1 (using 20mm graded aggregate) as inBeams, cantilevers, bressummers, lintels over 1.5m , lintel bend complete all as specified |
| 5 | Form work tosides and soffits of floor or roof beam, beam, hauchings, girders, bressumemers, lintels, cantilevers, shelves incl supports overhangs, chajja projection etc also splays between floors and beams, flat, rough finished surfaces of concrete complete all as specified and directed |
| 6 | S&F MS TMT Bars of 10 mm dia and over, cut to length, bent to shape requiredincluding cranking, bindingspirally for hooping for columns hooking ends and bindingwithand including MS wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified |
| 7 | S&F MS TMT Bars of 5 mm dia and overup to 10 mm diain stirrups, spacers and binders, cut to length bent to shape requiredincluding cranking, bindingspirally for hooping for columns hooking ends and bindingwithand including MS wire annealed not less than 0.9 mm dia or securing with clip complete all as specified |
| 8 | M&L for ramming earth below flooringincluding raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n.exc. 1.5 m high from base of floor finish complete all as specified and directed |
| 9 | M&L for 100mm thickPCC 1:4:8 type D-2 (Using 40 mm graded aggregate), as in flooring, sub base etc complete all as specified |
| 10 | M&L for 40 mm thickPCC 1:2:4 type B-0 (Using 12.5 mm graded aggregate), with glass dividing stirrups as in flooring complete all as specified |
| 11 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay complete with glazing bars, dovetailed or welded all as specified and directed by Engineer-in-Charge. |
| 12 | S&F Steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed |
| 13 | M&L for sheet glass ordinary quality 4 mm thick and glazing with oil putty in square n.exc 0.50 Sqm in each panes fixed to steel, metal or wooden window frames complete all as specified |
| 14 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer, calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge |
| 15 | S&F factory made single extruded WPC (Wood polymer composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (suspension grade),calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm² and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutters and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per direction of Engineer-in-charge. (Note : stainless steel butt hinges shall be paid separately) |
| 16 | S&F 100 mm long, Stainless Steel hinges with stainless steel screws complete all as specified and directed |
| 17 | S&F Aluminium anodised barrel tower bolts, 200 mm long of extruded section complete all as specified and directed. |
| 18 | S&F Aluminium anodised handles, cast type anodised 150 mm long complete all as specified and directed. |
| 19 | S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified |
| 20 | S&F 140 mm floor door stopper of Stainless Steel body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 21 | M&L for Rendering 10 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cementall as specified and directed by Engr -in - charge. |
| 22 | M&L for Rendering 15 mm thick in cement plaster 1:4onsurface other than fair face of brickworkor stone masonry surfaces or on one side of lathing,finished even and smooth without using extra cement complete all as specified and directed by Engr -in - charge |
| 23 | M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of distemper oil emulsion white/tinted over a coat of wall care putty finished even and smooth surface by hand roller complete all as specified and directed by Engr -in - charge |
| 24 | M&L for preparation of newly plastered or unplastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed by Engr -in - charge |
| 25 | M&L for cement concrete 50mm thick type C-2, 1:3:6 using 20mm graded aggregate as in plinth protection/path finishing surfaces even and fair (without using extra cement) complete all as specified and directed by Engr -in - charge |
| 26 | M&L for Roof trusses (framed),tubular vertical post, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections, tubular pole) including distance pieces, cleats etc. complete all as specified and directed by Engr -in - charge |
| 27 | S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet (ISI Marked) 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screw all as specified and directed. |
| 28 | M&L for Preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed |
| 29 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified |
| 30 | Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified |
| 31 | Point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLSH with multistranded copper conductor drawn through concealed in PVC rigid conduit suitable size with all accessories such as bend, reducers, MS hooks, modular junction boxes, 1.6 mm thick galvanised steel pressed modular boxes of suitable sizes for mounting of modular switches, sockets, fan regulator etc covered with modular cover plate of required size fixed with brass screws and cup washers including 1.5 sqmm copper conductor of same specification as earth continuity to connect common earth dolly complete for One light point/Fan point/Exhaust point controlled by one way switch all as specified and as directed |
| 32 | All as per Srl Item No. 31 here-in-before but One three pin socket out let 5 amps on the same board with other switches |
| 33 | All as per Srl Item No. 31 here-in-before but One 3 pin, 5A socket outlet point on independent board |
| 34 | S&F of LED tube light fitting 20W 230 V, surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire with suitable size complete all as specified and directed by Engineer-in-chrg |
| 35 | M&L for ceiling rose 3 terminal/PVC/polycarbonate isolated body complete all as specified and directed by Engr in charge |
| 36 | S&F Modular switch 1 way 6 amps one module switch all as specified and directed. |
| 37 | S&F Modular socket 6A 2/3 pin, 2 module socket all as specified and directed |
| 38 | S&F ceiling fans BLDC type regulator operated complete with blades, down rods and accessories, 230 V, 1200 mm sweep, with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) complete all as directed |
| 39 | S&F fan step regulator, 120W - 1 module suitable for BLDC fan complete all as specified and directed by Engr in charge (Modular type) |
| 40 | S&F sheet metal enclosure for DB\"s SPN 230 volts 8 way double door with 200 amps rated bus bar complete all as specified and directed. |
| 41 | S&F 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by Engr in charge |
| 42 | S&F amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr in charge |
| 43 | M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick hurried directly in ground vertically to a depth not less than 2.25 metre below ground level with tap edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (B SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel & wiremesh, PCC chamber in cement concrete (1:2:4) type B1 Including 40mm thick pre-cast ROC (1:2:4) type BO cover and 40x40x6mm angle iron frame on top of pit cover and excavation & earth work complete all as shown in electrical plate No, 3 of MES Schedule Part-of SSR-2009. complete all as specified and directed. Notes :- (i) GI wire upto earth test point/ equipment is included in this tam, (ii) Outer edge of earth pit chamber shall be 1 metre away from the outer edge of PCC chamber. |
| 44 | S&F energy efficient LED Security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Morethan 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily) |
| 45 | Supply and Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core in trenches/floors/wall and under road including connecting with suitable aluminium lugs complete all as specified and directed by Engr in charge |
| 46 | Supply and laying double wall corrugated pipe (DWC) size of 50/38 Non metallic resistance to compression typo 450, resistance to impact normal resistance to bending pliable resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation, non flame propagating conforming to IS-16205 (part-24) 2017 including necessary jointing material le snap fit coupler with rubber ring sealing plug, tees bend, angel bend etc for passing electrical cable complete all as specified and directed by Engr in charge |