| 1 | Supplying, laying jointing, testing in replacement of old unserviceable MS pipe of dia 150 mm Heavy duty class\"C\" confirming to IS - 1239 (Part-I), laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header, to connected out-going water mains,and laid in trench or above ground for wet riser/down comer complete all as specified and directed. |
| 2 | Supplying, laying jointing, testing in replacement of old unserviceable MS pipe,of dia 100 mm Heavy duty class\"C\" confirming to IS - 1239(Part-I), laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header, to connected out-going water mains,and laid in trench or above ground for wet riser/down comer complete all as specified and directed. |
| 3 | Supplying, laying jointing, testing in replacement of old unserviceable MS pipe,of dia 80 mm Heavy duty class\"C\" confirming to IS - 1239(Part-I), laid in trenches or laying on floors for connections to centrifugal pump sets for suction, pump to header, to connected out-going water mains,and laid in trench or above ground for wet riser/down comer complete all as specified and directed. |
| 4 | Supply and fixing in replacement SS (Stainless Steel) Single head landing valve with 80/100 mm N.B.flangedinlet, SS spindle (IS : 6603) controlled 63 mm dia instantaneous female outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories conforming to IS:5290.Includingfixing with anchor fastener and flanged tappingfromwet riser complete all as specified and directed. |
| 5 | Supply and fixing in replacement SS (Stainless Steel) double head landing valve with 80/100 mm N.B.flangedinlet, SS spindle (IS : 6603) controlled 63 mm dia instantaneous female outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories conforming to IS:5290.Includingfixing with anchor fastener and flanged tappingfromwet riser complete all as specified and directed. |
| 6 | M&Lin replacement of Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and directed. |
| 7 | Supply and Fixingin replacement 63 mm dia instantaneous pattern SS (Stainless Steel) Short branch pipe,20 mmdia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling required complete all as specified and directed. |
| 8 | Supply and fixing in replacement ofNon-percolating rubber reinforced lined fire hose pipe (as per IS : 636) Type-A of 63 mm dia and length as described below. The hose shall be rated for burst pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked SS male & femalecoupling (IS:903) bound & riveted to hose pipe with aluminum rivets & 1.5 mm GI wire. (For Internal Hydrant & External Hydrant). Complete all as specified and directed. |
| 9 | Supply and fixingin replacement of old unserviceable CI Non return Valve of dia 100 mmwith GM seat, PN-1.0 ISI marked, includingflange joints such as packing, nut and bolts etc complete all as specified and directed. |
| 10 | Supply and fixing in replacement of old unserviceable CI Non return Valve of dia 150 mmwith GM seat, PN-1.0 ISI marked, includingflange joints such as packing, nut and bolts etc complete all as specified and directed. |
| 11 | Supply and fixing sluice valve 80 mm bore class-1 ISI marked confirming to IS-14846flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gasket including jointing and testing complete all as specified and directed by Engineer-in-charge |
| 12 | Supply and fixing sluice valve 100 mm bore class-1 ISI marked confirming to IS-14846flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gasket including jointing and testing complete all as specified and directed by Engineer-in-charge |
| 13 | Supply and fixing sluice valve 150 mm bore class-1 ISI marked confirming to IS-14846flanged ends drilled pressure rating PN 1.6 having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gasket including jointing and testing complete all as specified and directed by Engineer-in-charge |
| 14 | Supply and fixing in replacement ofswinging type First Aid hose reel in red color drum with 30 mts long and 20 mm dia heavy duty rubber water hose, 20 mm dia gate gun metal valve,stop cock, (IS:778, class - II) terminating with SS coupling&nozzleof 6 mm outlet with shut off valve confirming to IS 8090 - 1976complete withMS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastener, bolts & nuts complete all as specified and directed. |
| 15 | Supply and fix in replacement Gun metal fire brigade inlet connection for connecting to external fire hydrant ring main consisting of four way 63 mm dia instantaneous type male coupling with built in check valve and with all accessories complete all as specified and directed. |
| 16 | Supply and fixing in replacement of signage shop glow in dark FIRE EXIT sign board with man running arrow symbol and stair of dimension 12\" x 6\" X 8 mm decorative transparent acralic, including fixing arrangement all as specified and directed. |
| 17 | M&Lin replacement of Pressure gauge 4\" dial 0-14 kgs rating complete all as specified and directed. |
| 18 | Supply and fixing in replacement air cushioning tank 250mm dia x 1000 mm high with dished top, made of minimum 6mm thick MS pipe/plate complete with 20mm dia. Brass air valve (ball type), 20 mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accesories complete all as specified and directed. |
| 19 | Supply and fixingin replacement branch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090 complete all as specified and directed. |
| 20 | M&L for painting with two coat of synthetic enamelled paint over a coat of red oxide primer on steel surface all as specified and directed. |
| 21 | Provision of fire point with shade and accessories like as bucket, fire bitter, fire hook, digging tool including earth work. PCC & 02 coat of red paint on all surface &equipment etc(as per sample) complete all as specified and directed. |
| 22 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 0.4 mpa working pressure for 150 mm dia MS pipe complete all as specified and directed. |
| 23 | M&L Yard hydrant Post / Stand Post 80/100mm DiaMS both flanged type including reducer as per site requirement & 1.0 meter height above ground complete all as specified and directed. |
| 24 | Excavation in trenches in any type of soil i.e. loose/soft not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth and getting out completeall as specified and as directed by Engineer-In-Charge. |
| 25 | All as per item No. 24 above but in hard/dense soil/cutting of road/hard standing/breaking of PCC etc complete all as specified and directed. |
| 26 | Returning,filling and including spreading, leveling and watering and well ramming in layers not exceeding 25 cm to achieve desired compactness as directed by Engineer-In-Charge. |
| 27 | Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed. |
| 28 | M&L for PCC (1:2:4) type B-1 finished even and smoooth without using extra cement as on brick pillars complete all as specified and directed. |
| 29 | Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric Centrifugal/Monoblock/High pressure motor ofcapacitiesupto 20 HP from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for replacement and back, re-installed after replacement including testing complete all as specified and as directed . |
| 30 | All as per item No 29.00 above but of capacity of 50 HP and upto 100 HP |
| 31 | Opening the electric Centrifugal/Monoblock/High pressure motor ofcapacity upto 20 HP including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight incl replacement of existing size bearings or other mechanical parts etc. including all other insulating material to make it functionalcomplete all as specified and as directed . |
| 32 | All as per item No 31.00 above but of capacity of 50 HP and upto 100 HP |
| 33 | Disconnecting and De-coupling the Centrifugal/Monoblock/High pressure pump ofcapacity upto 20 HP,after opening /cutting the rustednuts, bolts etc including transporting the pump to workshop for replacementand back, re-installed at existing position after replacement and providing new MS nuts, bolts,packing flange etcincluding testing complete all as specified and as directed. |
| 34 | All as per item No 33.00 above but of capacity of 50HP andabove upto 100HP complete all as specified and directed. |
| 35 | Opening the Centrifugal/Monoblock/High pressure pump ofcapacity, upto 20 HP replacementing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete all as specified and as directed.Note:-All Spare Parts required to make pump fully functional is deemed to be included in above quoted rates. |
| 36 | All as per item No 35.00 above but of capacity of 50HP andabove upto 100HP complete all as specified and directed. |
| 37 | S&F in replacement of Dry Chemical Powder Fire Extinguisher ( ABC Type ) 6 Kgs capacity completewith chromium plated gun metal union(cap), fitted with braided hose and opennozzle with initial charge of Dry Chemical Powder and gas cartridge (STORED PRESSURE TYPE)The extinguisher is internally coated with Lead Tinby electrolitic Process and externally coated with lead tin with Fire red Paint and cylinder bearing No. (IS:15683:2006) and the gascartridge bearing with ISI certitifcation markcomplete all as specified and directed. |
| 38 | Supply and fixingin replacement 3 pole power contactor type ML-5/6,80-160 Amps,415 Volts, 50 HZ complete all as specified and as directed. |
| 39 | S & F in replacement of Bimetal over load relay typeML 5/6, starter type MN, relay range 80-160 Amps CT operated complete all as specified and as directed. |
| 40 | S&F in replacement of3 Pole MCCB,250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA microprocessor base release with Icu= 100% ICSincl rotating handle & taking down the existing MCCBcomplete all as specified & directed |
| 41 | S&F in replacement of 3 Pole MCCB,400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA microprocessor base release with Icu= 100% ICSincl rotating handle & taking down the existing MCCBcomplete all as specified & directed |
| 42 | Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.5meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron strip of 25mmx4mm by means of Copper nuts, bolts and washers.Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :-(a)GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel shall be properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. |
| 43 | M&L GI strip 25mmx4mm buried in ground including necessary excavation & earth work in soft/loose soil and removal of excavated material to a distance n.exc 50 mtrs and deposited where directed including taking out old unserviceablecomplete all as specified and directed. |
| 44 | S&F in replacementElectronic timer type ET-100, 9 to 30 sec, 415V suitable for star-delta/DOL starter upto 100 HP capacity complete all as specified and directed. |
| 45 | S&F in replacement 3 phase sequence relay suitable for 30 HP motor with supply voltage range of 200-480 VAC, frequency 50 Hz & response time less than 1 sec complete all as specified and directed. |
| 46 | S&F in replacementsingle phase preventor operating volt 280V to 520V VAC, 50Hz response time 200 MS suitable for 3 phase centrifugal motor upto 100HP complete all as specified and directed. |
| 47 | S&F in replacement Digital ammeter of existing size 100mm (Square type) with selector switch & copper thimble and connecting up complete all as specified and directed. |
| 48 | S&F in replacementDigital multimeter of existing size 100mm (Square type)with selector switch &copper thimble and connecting up complete all as specified and directed. |
| 49 | Supply & fix in replacement of LED type Indicatinglamp type of voltage AC/DC set of RYB,as per matching to existing complete all as specified and directed. |
| 50 | Supply & fix in replacement of pressure switch of range 2-14 bar rating with suitable size & core cable upto 10 mtrs length complete all as specified and directed. |
| 51 | Supply and fixing welded to flanges on ends for GI/MS pipe of dia upto150 mm & welded flange of suitable size for making connection to internal hydrant landing valve,flange not less than 15mm thick complete all as specified and directed. |
| 52 | Supply, install, test and commissioning of fully automatic electrical driven hydrant main and jockey pump control panel for upto110 HP for fire pump set with electrically operated water pressure soleniod switch with necessary mounting / connection and other required accessories with electrical and mechanical connection to operate at pressure range of 2.5 to 7.5 Kg / Cm2 complete .The panel should be CPRI approved suitable for fire fighting indoor cubicle type, made out of 2 mm thick CRCA sheet with aluminium bus bars of capacity 600 A for 3 phases and halffor neutral including digital type metering equipment like voltmeter, ammeter with selector switches duly painted with powder coating all as specified, directed and comprising the following :-(i)MCCB, 4P, 400 A, 50 KA (mircorprocessor)- 1 No (incomer)(ii) MCCB, 4P, 200 A, 25 KA (mircorprocessor)- 2 Nos (01 Main motors and 01 Engine control panel)(iii)MCCB, 3P, 63 A, 16KA - 3 Nos (01 Jockey pump, 02 water supply motors)(iv)Automatic star delta starter suitable for main fire pump set , jockey pump set & water supply motors of suitable size with overload protection and single phase preventor - 4 Nos(v)Angle iron base frameof 50x50x6mm for the fire panel with PCC grouting (vi)Ammeter, CT operated of suitable rating with selector switch digital type including CTs for each pumping sets - 4 Nos(vii)Digital type voltmeter 0-500V with selector switch - 1 No(viii)Set of indication lamps RYB, LED type with base(ix)Electrically operated water pressure soleniod switch to operate at pressure range of 2.5 to 7.5 Kg / Cm2 complete all as specified and directed.(x) MCB SP 32 Amps -02 No for pump house lighting and powerNote:-(i)Jockey pump to operate when pressure falls below 6.5 Kg / Cm2 in the hydrant pipe(ii)Main pump to operate when pressure falls below 5.5 Kg / Cm2(iii)Cost of wiring to pressure switch for pump starter deemed to be included in the rate quoted(iv)Cost of wiring from pump to fire panel with 25 sq mm copper conductor multistranded six run in suitable pipe deemed to be included in the rate quoted. |
| 53 | Servicing / Maintenance of main fire hydrant pump by original equipment manufacturer and opening pump / motor from foundation, cleaning with emery paper, greasing of movable parts, glands, nut & bolts of any type/shape, painting with two coat as per colour code suitable for main fire hydrant pump horizontal mounted split case two stage Centrifugal pump having discharge of any LPM/ Head or maxm upto 2850 LPM at 80 mtrs head suitable for fire fighting and conforming to IS-12469-1988 complete with totally enclosed drip proof indication motor squirrel cage operate on 3 phase 415 volts 50 Hz capable of delivering upto 100HP as required to drive the pump at 1440 RPM and giving a jet pressure not less than 3.5 kg/sq cm at the top most hydrant suitable for automatic operation , mounted on a commonbase frame including replacement of unsv pressure guage , pressure switchcomplete including replacement of unsv PCC foundation block completely and casting of new PCC foundation for fairfunctioning of pump with nut & bolt in foundationand making connection with tail / tapper pieces to connect supply and delivery pipes, testing of Fire hydrant for indoor hydrant/outdoor hydrant and checking the pressure at top most hydrant and arranging the demostration by deploying the staff for extingusing the fire near the building and replacing the following unsv items of the fire pump as per OEM recommendations :-(a)Fabricated mild steel common base frame of suitable size with antivibrating pads including all other auxillaries etc(b)Coupling guard(c)Air vent for casing(d)Pressure gauge of 150mm dia on delivery side(e)Suction pipe GI medium grade for each pump all as per suction side requirement upto foot valve(f)Delivery pipe GI medium grade of sizes as specified in IS 3844-1989 upto common header (g)Wiring with PVC insulated copper conductor of 25 SQ MMsize, single core multistranded, 1100V graded in 6 runs drawn in PVC pipe of suitable dia fixed on wall or concealed in floor complete all as specified and directed..(h)CI foot vale of suitable size (j)Foundation of pumping set shall be re aligned completely as per manufacturers standardsNote:- All rates of the above mentioned items are deemed to be included in quoted rates. |
| 54 | Servicing / Maintenance of Diesel Engine driven main fire hydrant pump by original equipment manufacturer and opening pump / engine from foundation, replacing unsv fuel pipe, engine oil, cleaning of deasel tank, cleaning with emery paper, greasing of movable parts, glands, nut & bolts of any type/shape, painting with two coat as per colour code suitable for Diesel Engine driven main fire hydrant pump horizontal mounted split case two stage Centrifugal pump having discharge of any LPM/ Head or maxm upto 2850 LPM at 80 mtrs head suitable for fire fighting and conforming to IS-12469-1988 complete with totally enclosed drip proof indication motor squirrel cage operate on 3 phase 415 volts 50 Hz capable of delivering upto 110 BHP as required to drive the pump at 1440 RPM and giving a jet pressure not less than 3.5 kg/sq cm at the top most hydrant suitable for automatic operation , mounted on a commonbase frame including replacement of unsv pressure guage , pressure switch andcoupled to diesel engine of adequate HP complete including replacement of unsv PCC foundation block completely and casting of new PCC foundation for fairfunctioning of pump with nut & bolt in foundationand making connection with tail / tapper pieces to connect supply and delivery pipes, testing of Fire hydrant for indoor hydrant/outdoor hydrant and checking the pressure at top most hydrant and arranging the demostration by deploying the staff for extingusing the fire near the building and replacing the following unsv items of the fire pump as per OEM recommendations :-(a)Fabricated mild steel common base frame of suitable size with antivibrating pads including all other auxillaries etc(b)Coupling guard(c)Air vent for casing(d)Pressure gauge of 150mm dia on delivery side(e)Suction pipe GI medium grade for each pump all as per suction side requirement upto foot valve(f)Delivery pipe GI medium grade of sizes as specified in IS 3844-1989 upto common header (g)Wiring with PVC insulated copper conductor of 25 SQ MMsize, single core multistranded, 1100V graded in 6 runs drawn in PVC pipe of suitable dia fixed on wall or concealed in floor complete all as specified and directed..(h)CI foot vale of suitable size (j)Foundation of pumping set shall be re aligned completely as per manufacturers standardsNote:- All rates of the above mentioned items are deemed to be included in quoted rates. |
| 55 | Servicing / Maintenance of jockey pump by original equipment manufacturer and opening pump / motor from foundation, cleaning with emery paper, greasing of movable parts, glands, nut & bolts of any type/shape, painting with two coat as per colour code suitable for main fire hydrant pump horizontal mounted split case two stage Centrifugal pump having discharge of any LPM/ Head or maxm upto 190 LPM at 80 mtrs head suitable for fire fighting and conforming to IS-12469-1988 complete with totally enclosed drip proof indication motor squirrel cage with bronze impellers operate on 3 phase 415 volts 50 Hz capable of delivering upto 20HP as required to drive the pump at 2900 RPM and giving a jet pressure not less than 3.5 kg/sq cm at the top most hydrant suitable for automatic operation , mounted on a commonbase frame including replacement of unsv pressure guage , pressure switchcomplete including replacement of unsv PCC foundation block completely and casting of new PCC foundation for fairfunctioning of pump with nut & bolt in foundationand making connection with tail / tapper pieces to connect supply and delivery pipes, testing of Fire hydrant for indoor hydrant/outdoor hydrant and checking the pressure at top most hydrant and arranging the demostration by deploying the staff for extingusing the fire near the building and replacing the following unsv items of the fire pump as per OEM (a)Fabricated mild steel common base frame of suitable size with antivibrating pads including all other auxillaries etc(b)Coupling guard(c)Air vent for casing(d)Pressure gauge of 150mm dia on delivery side(e)Suction pipe GI medium grade for each pump all as per suction side requirement upto foot valve(f)Delivery pipe GI medium grade of sizes as specified in IS 3844-1989 upto common header (g)Wiring with PVC insulated copper conductor of 16 SQ MMsize, single core multistranded, 1100V graded in 6 runs drawn in PVC pipe of suitable dia fixed on wall or concealed in floor complete all as specified and directed..(h)CI foot vale of suitable size (j)Foundation of pumping set shall be re aligned completely as per manufacturers standardsNote:-All rates of the above mentioned items are deemed to be included in quoted rates. |
| 56 | Servicing / Maintenance of Terrace pump by original equipment manufacturer and opening pump / motor from foundation, cleaning with emery paper, greasing of movable parts, glands, nut & bolts of any type/shape, painting with two coat as per colour code suitable for main fire hydrant pump horizontal mounted split case two stage Centrifugal pump having discharge of any LPM/ Head or maxm upto 450 LPM at 30 mtrs head suitable for fire fighting and conforming to IS-12469-1988 complete with totally enclosed drip proof indication motor squirrel cage with bronze impellers operate on 3 phase 415 volts 50 Hz capable of delivering upto 15 HP as required to drive the pump at 2900 RPM and giving a jet pressure not less than 3.5 kg/sq cm at the top most hydrant suitable for automatic operation , mounted on a commonbase frame including replacement of unsv pressure guage , pressure switchcomplete including replacement of unsv PCC foundation block completely and casting of new PCC foundation for fairfunctioning of pump with nut & bolt in foundationand making connection with tail / tapper pieces to connect supply and delivery pipes, testing of Fire hydrant for indoor hydrant/outdoor hydrant and checking the pressure at top most hydrant and arranging the demostration by deploying the staff for extingusing the fire near the building and replacing the following unsv items of the fire pump as per OEM recommendations :-(a)Fabricated mild steel common base frame of suitable size with antivibrating pads including all other auxillaries etc(b)Coupling guard(c)Air vent for casing(d)Pressure gauge of 150mm dia on delivery side(e)Suction pipe GI medium grade for each pump all as per suction side requirement upto foot valve(f)Delivery pipe GI medium grade of sizes as specified in IS 3844-1989 upto common header (g)Wiring with PVC insulated copper conductor of 10 SQ MMsize, single core multistranded, 1100V graded in 6 runs drawn in PVC pipe of suitable dia fixed on wall or concealed in floor complete all as specified and directed..(h)CI foot vale of suitable size (j)Foundation of pumping set shall be re aligned completely as per manufacturers standardsNote:- All rates of the above mentioned items are deemed to be included in quoted rates. |
| 57 | S&F in replacement Jockey pump controller with encloser capacity upto 7.5Hp 415V 50Hz with overload protection including provisionfor Auto/Manual Mode incase of Auto failure & Control circuit for Pressure Maintain via Pressure Switch incl suitable size & core cable for motor to pump controller connection upto 10 mtrs distance complete all as specified and directed. |
| 58 | M&L for mild steel work MS sheet, angle iron, flat iron etc including cutting, welding anddismantling old unserviceable MS workcomplete all as specified and directed. |