| 1 | Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) |
| 2 | Taking down Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame) |
| 3 | S & F 165x60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc.,complete all as specified and directed. |
| 4 | S & F 105x60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs,lock strike plate, etc.,complete all as specified and directed. |
| 5 | M&L for cement concrete 1:3:6, type-C-0 (12.5mm graded stone aggrgate) as in filling in steel frame/roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed. |
| 6 | Refixing of Shutters of any descriptionbut exc 1 sq. m and n exc 2 sq. m each all as specified and as directed. |
| 7 | S&F 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, factory made commercial type on both sides. |
| 8 | S & F 35 mm thick Second class hard woodkiln seasoned and chemically pressure treated Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. |
| 9 | S&F 25 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides including with necessary fittings all as specified and as directed. |
| 10 | S & F Solid PVC Door Frame of size 50mm x 95mm made out of 5mm plain colour PVC Sheet reinforced with MS Square etc. |
| 11 | Supplying and fixing in frame at site, factory made solid panel pvc moulded doorshutter 28 to 30 mm thick (style) with 2,4,or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS. |
| 12 | S&F anodised aluminium frame for doors, windows, ventiletors with one or more rebates including joining cleat for fixing etc complete all as specified in cl power coating above aluminium section.(minimum thickness of poweder coating 50 micron). |
| 13 | S&F for anodised window/ventiletor shutters, side hung type without sash bars aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips,ruber neoprene packing,anodised aluminium snap beading screws,anodised aluminium fittings such as peg stays 150 mm long(1 no),hinges type-B-21 100 mm long( 2 no) suitable handle 1 no complete all as specified incl power coating of any colour (thick ness of powder coating not less than 50 micron). |
| 14 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or revited, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe.290. Gde-E-165 |
| 15 | S & F 4 mm thick Sheet glass, ordinary quality and glazing with necessary fitting beadsin squares not exceeding 0.5 Sq. M in each pane |
| 16 | S & F 4 mm thick Sheet glass,, ordinary quality in square nexc 0.50sqm each pane glazed with oil putty or fixed with necessary beading. |
| 17 | S & F 4 mm thick frosted glass,, ordinary quality in square nexc 0.50sqm each pane glazed with oil putty or fixed with necessary beading. |
| 18 | Supplyand fixedGI wire cloth with 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium stapple complete all as specified and directed. |
| 19 | S&F in repair 18/19 mm thick pre-laminated particle boards exterior grade prelaminated both sides with decoratative choice lamination fixed in alum frame work as specified and as required. |
| 20 | S & F100 mm long medium weight, cold rolled mild steel Butt hinges and fixed. |
| 21 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised. |
| 22 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section |
| 23 | S & F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy. |
| 24 | Supply fix in repairs Harrison rails, mild steel, chromium plated fixed alongwith 2 Nos. of brackets, stops, rollers etc, complete all as specified. |
| 25 | S&F in repairs 10 Ltrs. Capacity PVC flusing cisternlow level slimline or equivalen make / model with all accessories. |
| 26 | Supply & Fix in repairs Vitreous china squating pan orrissa pattern size 630 x 450 mm white withintegral foot rests excluding flusing cistern and flush pipe) and including \"P\" or \"S\" traps. |
| 27 | Supply & Fix in repairs Vitreous EWC Size 580 x440 mm while with includig \"P\" or \"S\" traps with 100 mm bore pipe. |
| 28 | S & F in repairs Vitreous China Ware Wash hand basin white, flat back, size 450 x 300 mm sizeincluding cutting for and pinning ends of brackets or erecting stand including pedestal all as specified and as directed. |
| 29 | S & F for cromimum plated helth faucet shower with CP flexible pipe up 15 mm bore (ABS Body) with 1 mtr long Easy Flex tube in chrome finish complete all as directed |
| 30 | PVC connection 15 mm bore450 mm long |
| 31 | S&F in repairs brass cromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges. |
| 32 | Supply and fix 600mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers incl taking down old one. |
| 33 | S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar of dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm. |
| 34 | Dismantling floor, hearth or wall tiling incuilding cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the permises. |
| 35 | Glazed ceramic white tiles in vertical surfaces 300x600X7 mm thick set and jointed in neat cement slurry & painted in white or colour cement to match incl sreed bed 10 mm thick in CM 1:4 . |
| 36 | M&LNon - skidwhite Ceramic tiles (square/ rectangular) area of each tile 300X300X8 mm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes. |
| 37 | M&LNon - skidwhite Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes. |
| 38 | M& L for Granite of any type 20 mm thick machine cut bedded and jointed with grey cement slurry and pointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete incl 20 mm thick screed bed 1:6 CM in floors in cluding demolition all as specified and directed. |
| 39 | M& L for Kota stone slab flooring of 20-25 mm thick over cement screed jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding and polishing complete incl 20 mm thick screed bed 1:6 CM in floors. |
| 40 | M& L for Kota stone slabof 20-25 mm thick in riser,of steps, skirting, dado over cement screed jointed with grey cement slurry mixed with pigment to match the shade of slab including grinding and polishing complete incl 10 mm thick screed bed 1:4 CM in floors. |
| 41 | M&L for 75 mm thick cement concrete as in plinth protection type C-1 1:3:6 (using 20mm graded aggregate) finishing concrete surface even and smooth with using extra cement including demolition complete all as specified and directed. |
| 42 | M&L for Pre-cast RCC 1:2:4 type B1 using 20mm graded stone aggregate as in landing, cover slabs (for manhole covers, drains , shelvess etc) set in CM 1:6 including demolition complete all as specified. |
| 43 | M & L for TMT reinforcement 10 mm dia and over cut to length bent to shape including cranking, hooking etc binding with mild steel wire not less than 0.90 mm dia (annealed) all as directed complete. |
| 44 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets. |
| 45 | S&F for Anodised aluminium/ GI snap grid power coated framed work of size main runner 39x24.70x0.80 mm, cross tee size 29.x24.70x0.80 mm, wall angle 22.2x22.2x0.65 mm and size of grid 605x605 mmfor false ceiling all as specified with hangers 4mm thick GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm longcomplete all as specified and as directed. |
| 46 | M & L for 4m thick Non Asbestos designed Cement E board incl two coats of distempering in one side as approved by GE of size fixedin ceiling as specified and directed. |
| 47 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. |
| 48 | Demolition of brick work or stone/ boulder masonry built in cement mortar or cement lime mortar including removal to rubbish complete all as specified and as directed. |
| 49 | M&LBrick work with sub class \"B\" bricks straight of curved on plan exc 6m mean radius built in CM 1:6 including flush pointing with same mortar as the work proceed complete asspecified. |
| 50 | M&L for 15 mm thick plaster on fair faces of brick work or concrete surface in cm (1:4) with wpc @2% by weight face of conc work to wall surface and the surface is finished even and smooth without using extra cement |
| 51 | M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth. |
| 52 | M&L rendering 5mm thick of cement plaster 1:3on concrete surfaces of ceiling finished even and smooth(without using extra cement.). |
| 53 | Supply only Integral water proofing compound |
| 54 | Removing complete existing treatment incl pcc pedding of roof surfaces by picking, sweeping clean and washing down with water to remove dust etc., |
| 55 | M&L for brushing neat cement slurry with 03 Kg of cement per Sqm |
| 56 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 . (Internal water proof compound measured seperately) |
| 57 | M&L 25 mm thick cement concrete PCC Type B0 1:2:4 using 12.5 mm graded aggregate. |
| 58 | M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced applicationincluding coating the surface with water based bituminous primer blow bitumen of 85/25 or 90/15 at 1.2 Kg/Sqm both at bottom and top of the membrance and finally finished with one coat of bitumenous aluminium primer at 100 gm per sqm complete all as specified. |
| 59 | Taking down rain water pipes inculding all fittings any size and pattern |
| 60 | S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls. |
| 61 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes double socketed in any length with rubber ring joints fixed in walls. |
| 62 | S & F 110 mm bore PVC (SWR) bends of any radius. |
| 63 | S & F 75 mm bore PVC (SWR) bends of any radius. |
| 64 | S & F 110 mm bore PVC (SWR) junction single (Single `T\") equal or unequal with access door |
| 65 | S & F 75 mm bore PVC (SWR) Vent Cowl. |
| 66 | M&L 75 mm bore for cast iron Nahani trap with grating incl jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) |
| 67 | Supply & fix 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed. |
| 68 | Supply & fix 40 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed. |
| 69 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store |
| 70 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store |
| 71 | Taking up or down 25 or 32 mm bore steel tubing and connections, including cleaning for Refixing or removal to store |
| 72 | Supply and laying 20 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 73 | Supply and laying 25 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 74 | Supply and laying 32 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 75 | S & F in repairs15mm bore angular/ concealed stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions. |
| 76 | S & F in repairs 15 mm bore chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule. |
| 77 | S & F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed. |
| 78 | S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing tosteel pipe or union |
| 79 | M&L for Rebuilding the section of damaged RCC elements to its original size or as per consultants recommendation in thickness of 40-100mm by providing and casting with ready to use non shrink, cementitious free flow micro-concrete SikaRep Microcrete-4 or equivalent having compressive strength > 60 N/mm2 (28 days) according to ASTM C 1107-99 including providing and fixing of watertight foam faced finish shuttering of minimum 18mm thickness and supporting formwork, all lead lift, mixing, placing, de-shuttering, levelling the surface by grinding off cementitious slurry or cementitious joints differences if any to satisfaction of Engineer-in-charge and curing. |
| 80 | Preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of Red Oxide, zinc chorme and applying two coat of synthetic enamel paint. |
| 81 | Preparation of old paintedsteel surfaces of any description, over 10 cm width or girth, not otherwise described appling onecoat of synthetic enamel paint. |
| 82 | Preparation of new or previously treated wood surfaces of any description, over 10 cm width or girth , not otherwise described appling one coat of pink primer over applying two coat of synthetic enamel paint. |
| 83 | Preparation of old painted wood surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint. |
| 84 | Material & Labour for preparation of new wall surface and applying 1 mm thick wall care putty and appling Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm over new surface all as specified and as directed. |
| 85 | M & L for Complete removal of old surface for preparation of old wall surface applying 1 mm thick wall care putty and Two or more coats of 100% Premium acrylic exterior emulsion paint with silicone additives of required shade additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @2.20 litre/ 10 sqm over new surface all as specified and as directed. |
| 86 | M&L for preparation of new plastered surfaces of walls and applying over and including 1mm thick wall care putty one primer coat and two coats of acrylic distemper including plastered surface to prepara-tory to distempering complete all as specified and directed. |
| 87 | M&L for complete removal of old surfaces of walls and applyingover and including 1mm thick wall care putty one primer coat and two coats of acrylic distemper on plastered/putty surface to prepara-tory to distempering complete all as specified and directed. |
| 88 | Preparing new surfaces of ceilings by brooming down or by steel wire brushing and applying three coats of white wash. |
| 89 | M&L for preparation of old decorated plastered surfaces of ceiling and applying one coat of white wash complete. |
| 90 | Dismantlingwater tanks and removing to store exc 500 & not exc 1000 ltrs |
| 91 | S&F 500 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed. |
| 92 | Taking down carefully existingunserviceable copper/ aluminiumpoint wiring (light,fan , call bell, two way, socket orpower point etc)completewith fittings/fixures such asswitches sockets, ceiling rose, fan regulators, bell push,call bell,bracket light fittings and making goodto the disturbedsurface complete all asdirected by Engr-in-Charge. |
| 93 | Taking down the existing unservicable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified by Engr-in- Charge. |
| 94 | Taking down carefully unsv aluminium submain wiring of any type /locationincludingconduit /casing and earth wire and making good the distributed surface of walls /ceiling matching with existing finishes all as directed by Engr-in-Charge. |
| 95 | Taking out unsv UG Cable any cross sectional area and connection of any description of any description laying in trenches or fixing with wall or poles all as specified and directed. |
| 96 | Material and labour for point wiring with 1.5 sqmm (nominal area) FRLSH PVC insulated stranded copper conductor single core including PVC conduit of appropriate size concealed in wall, pressed steel concealed modular terminal boxes of required size and with modular frame plate of adequate size, painting terminal boxes inside and out side with one coat red oxide primer complete with all accessories and all as specified including 1.5 Sqmm FRLSH PVC insulated unsheathed multistranded copper earth conductor to common earth and connected to earth dollyfor fan / light / exhaust fan/ bell point controlled by one switch.Note:-1. Cost of PVC conduit, modular steel terminal boxes, modular frame plate cover etc; are deemed to be included in the quoted rate.2. Cutting chases on walls / ceilingand making good disturbed surfaces including finishing with cement mortar (1:3)and ,putty and plastic paint matching with existing surfaceetc; shall be deemed to be included in the rate quoted above. (a) One light ,fan , bell point controlled by one, one way switch 5 Amps |
| 97 | (b) One 3 point 5 Amps socket outlets point controlled by one switch on the same board |
| 98 | (c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board |
| 99 | Description all as per item No 96here in before but for one light point controlled by one, two way switch 5 Amps complete all as specified. |
| 100 | Description All as per item No 96 above but with two run of 2.5 sqmm multi stranded Single core copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with one run of FRLSH PVC 2.5 Sqmm multi standard insulated sheathed copper wire as earth continuity conductor along with wiring and connecting to the common earth dolly on independent board. |
| 101 | S & F Modular Switch , single pole one way 6 Amps , 1 module , 230 Volts complete all as specified. |
| 102 | S & F Modular Switch , single pole one way 16 Amps , 1 module , 230 Volts complete all as specified. |
| 103 | S & F Modular switch pianotwo way, 6 amps 1 module, 230 volts.complete all as specified and directed. |
| 104 | S & FModular Socket , 2 /3 pin combined, 6 Amps , 2 modulecomplete all as specified and directed. |
| 105 | S & F Modular Switch , single pole one way 16 Amps , 1 module , 230 Volts complete all as specified. |
| 106 | S & FModular Socket , 2/3 pin combined , 16 Amps , 2 modulecomplete all as specified and directed. |
| 107 | S&F ceilling rose(white) three terminal surface bakelite type AC 50 Hz 230 Volt of size 65x50mm complete all specified |
| 108 | S & F modular ceiling fan regulator step type 2 Module, heavy duty suitable to work on 230 Volt AC supply complete all as specified. |
| 109 | S & F modular bellpushflush type 5 amps, 230 volts.complete all as specified and directed.. |
| 110 | S & F call bell suitable to work on 230 volts Ac supply complete all as specified. |
| 111 | S & FLamp holder(white) with insulated body, with back plate suitable for pendant / batten fittingscomplete all as directed. |
| 112 | S & F LED ADORE 10 W B22 CDL 5 STAR LAMPwith B 22 base capacity 1200 lumencomplete all as specified. |
| 113 | S & F sheet metal enclosure MCB DBTPN 4 way with 200 amps rated bus bar 415 volts double door with magnetic locking system complete enclosure all as specified |
| 114 | S & F RCBO,s for earth leakage , overload and short circuit protectionFour Pole415volts , 30mA,suitable for fixing in MCB TPN DB of capacity 63 amps complete all as specified and directed. |
| 115 | S & F Sheet metal enclosure for MCB DB double door 240V single pole & Neutral 8 way with common bus bar. |
| 116 | S & F RCBO,s for earth leakage , overload and short circuit protectionDouble Pole230volts , 30mA,suitable for fixing on MCB DB of capacity 32Ampscomplete all as specified. |
| 117 | S & F MCB \"B\" series single pole 5 to 32 Amps, breaking capacity 10KA. |
| 118 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorativeultra slim round profile LED lighting fixture with extruded polycarbonate , environmental friendlyenergy efficiebt ready to use packwith driver, holder including LED tube lightconnecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 119 | S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and PC Cover having TOP opening seperate driver compartment with IP 66 Protection and impact resistance of IK07 with electronic driver of capacity 20 watts with pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade of aqequate dia 1.5 mtr long bend to required shape complete all as directed by Engineer-in-Charge. |
| 120 | S&F in replacement decorative, wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LED lamp B22 base made out of polycarbonate with unbreakable globe/frame suitable for LED bulb and provision of LED bulb 09 watts complete all as specified and as directed. |
| 121 | S & F Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired andnecessary mounting arrangements , provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting all as directed by Engineer-in-Charge. |
| 122 | Excavation in trenches n exc 1.50 m wide andn exc 1.50 m depthin soft /loosesoil andgetting out for lying of cable and errection pipeetc complete all as directed. |
| 123 | Returning, filling in, trenches insoft /loose soilincluding spreading, leveling, watering and well ramming in layers not exc 25 cmcomplete all as directed. |
| 124 | Removal of excavated soil to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting pointcomplete all as directed. |
| 125 | Materal and labour for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.(Note: Thickness after punning down shall be measured for payment) |
| 126 | Supply & Laying well burnt brick , locally available best quality (sub class \"B\" bricks ) laid in trences perpendicular to UG Cable protection complete all as specified. |
| 127 | Supply & Laying XLPE LT heavy duty UG Cable of size 25 Sqmm 3.5 Core laid in trences /floor/on wall/service connection PVC Insulated, sheathing and armd 1100 Volts grade with aluminium conductor including connection to the main switch/cut out MCB/MCCB with necessary lugs after cutting to required length complete all as specified and directed. |
| 128 | S & F GI Tubing light grade of size 40mm dia in protection of cable at road crossing /hard standing/pole protection fixed with clam as per site requirement etc all as specified and directed. |
| 129 | Taking down ceiling fan/ Exhaust Fan of any sweep, keeping with safe custody and refixing the same with replacement of unsv core PVC insulated PVC sheathed 3 core multistranded copper conductor cable of size 1.5 Sqmmfrom ceiling rose to fan terminal over hauling the fan complete all as specified and as directed. |
| 130 | M & L for sub main wiringwith 2 run of FRLSH PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLSH PVC insulated & unsheathed copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through & including PVC conduit of suitable size in Surface/concealed all as directed. |
| 131 | Boring holes horizontally under Road without damaging the surface of Road of any type (minimum 1.0 METRE below the Road Surface with the help of GI Tubing not exc. 40mm bore (dia) for passing of UG Cable, complete all as specified and as directed. NOTE: GI Pipe laid will be measured and paid separately under appropriate Item. |
| 132 | Material and labour for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below normal ground level connected to GIearth wire 4 mm dia connected tomain earthing lead from earth electrode to test point upto 7.5 metre drawn through and including GI protection pipe of light grade 15 mmbore by means of bolts, nuts, check nuts and washers including excavation earth work provisioning of PCC chamber made of PCC 1:3:6 RCC cover funnel with wiremesh 20mm dia watering pipe Medium grade, GI protection pipe 20mm dia bore all as specified in Electrical Plate No.3 of SSR Part I. |
| 133 | Supply and Fix Cable end termination kit for LT1.1 KV XLPE Cable for Cable 25Sqmm 3.5 Core cable complete all as specified and directed . |
| 134 | Taking down Electric/Prepaid Meter keeping in safe custody and refixing in its original position complete all as specified and as directed. |