| Sl. No. | Item Description |
| 1 | BUILDINGS & STRUCTURE (Sch \"A\" PART-I) |
| 2 | Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,76,52,000.00inserted by the MES in Schedule ‘A’ Part-I. |
| 3 | EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch \"A\" PART-II) |
| 4 | Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 1,12,18,737.54 inserted by the MES in Schedule ‘A’ Part-II. |
| 5 | INTERNAL WATER SUPPLY (Sch \"A\" PART-III) |
| 6 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs.14,013.48 inserted by the MES in Schedule ‘A’ Part-III. |
| 7 | INTERNAL ELECTRIFICATION (Sch \"A\" PART-IV) |
| 8 | Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 5,73,014.75 inserted by the MES in Schedule ‘A’ Part-IV. |
| 9 | ROAD, PATH, CULVERT & HARDSTANDING (Sch \"A\" PART-V) |
| 10 | Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT & HARDSTANDING)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 79,45,301.40 inserted by the MES in Schedule ‘A’ Part-V. |
| 11 | AREA DRAINAGE(Sch \"A\" Part-VI) |
| 12 | Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 60,37,276.00inserted by the MES in Schedule ‘A’ Part-VI. |
| 13 | SEWAGE DISPOSAL (Sch \"A\" PART-VII) |
| 14 | Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 54,784.87inserted by the MES in Schedule ‘A’ Part-VII. |
| 15 | EXTERNAL WATER SUPPLY (Sch \"A\" Part-VIII) |
| 16 | Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 1,33,87,959.30 inserted by the MES in Schedule ‘A’ Part-VIII. |
| 17 | EXTERNAL ELECTRIFICATION(Sch \"A\" PART-IX) |
| 18 | Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 47,63,314.52 inserted by the MES in Schedule ‘A’ Part-IX. |
| 19 | FIRE FIGHTING (Sch \"A\" Part-X) |
| 20 | Lump sum price worked out by the Contractor for “(FIRE FIGHTING)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,58,605.41 inserted by the MES in Schedule ‘A’ Part-X. |
| 21 | (PROTECTIVE WORK, BOUNDARY WALL, RETAINING WALL, STEEL GATE AND FENCING) (Sch \"A\" Part-XI) |
| 22 | Lump sum price worked out by the Contractor for “(( PROTECTIVE WORK, BOUNDARY WALL, RETAINING WALL, STEEL GATE AND FENCING))”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs.1,17,59,837.29 inserted by the MES in Schedule ‘A’ Part-XI. |
| 23 | LIGHTNING PROTECTION (Sch \"A\" Part-XII) |
| 24 | Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION AND DG SET) ”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 7,98,041.40inserted by the MES in Schedule ‘A’ Part-XII. |
| 25 | DG SET (Sch \"A\" Part-XIII) |
| 26 | Lump sum price worked out by the Contractor for “(DG SET)”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 45,437.40inserted by the MES in Schedule ‘A’ Part-XIII. |
| 27 | MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch \"A\" Part-XIV) |
| 28 | INTERNAL WATER SUPPLYS&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down for iron pipe 20 mm bore and fixed complete all as specified and as directed. |
| 29 | INTERNAL ELECTRIFICATIONS & F3 star (EEL) LED lamp 5w capable to output 525im, 6500k suitable base B22 type completeall as specified and directed. |
| 30 | S&F Flame proof distribution board 8 way with connected accessories prewired complete all as specified & directed. |
| 31 | S&F Flame proof metallic junction box 4 way, threaded type complete all as specified & directed. |
| 32 | S&F Flame proof flexible metallic hose conduit 20mm dia, 500mm long complete all as specified & directed. |
| 33 | PROTECTIVE WORK, BOUNDARY WALL, STEEL GATE AND FENCINGConstruction of Steel Gate 5.5 mwide and 2.3 m height with RCC M-25 Columns with foundation with necessary earthwork, PCC below foundation, plastering, painting complete all as specifiedalongwith 1.2 m wide wicket gate completeall as specified and shown on drawing No. CESZ/TD/72 Sheet No. 1/2 & 2/2.. |
| 34 | EXTERNAL ELECTRIFICATIONS & F and commissioning of outdoor factory made weather and vermin proof, CPRI approved MS cubical LT panel, fabricated with 3.15 mm thick MS sheet for outer and 1.6 mm thick for inner shell & zinc metal powder coated paint over a coat of primer red oxide and reqd capacity of aluminium bus bar channel insulated with heat shrinkable sleaves and mounted on epoxy insulator of reqd size in conical type, double door be provided with proper hinged incl locking arrangements, provn of suitable cable ducts at bottom and control wire of 2.5 sqmm multi stranded copper conductor with adequate size of lugs be properly bunched. The cubical panel be fixed on PCC (1:2:4) type B1 foundation of reqd size. The compart-mentalized to accommodated to incomer and outgoing MCCBs, MCB\"s and measuring eqpt and separate door will cover to each MCCB incl suitable space for accomodate the followings :- (a) Incomer - ACB 4 pole 630 Amp, 50 Hz 415 V AC with rupturing cap 50 KA - 01 Nos (b) Outgoing - (i)MCCB 4 pole 400 Amps 50Hz 415 Volt AC 25 KA -01 Nos (ii)MCCB 4 pole 125 Amps 50Hz 415 Volt AC 16 KA -02 Nos (iii) Aluminium bus bar 500 Amp 04 Nos -01 Set (iv) Voltmeter - 01 Nos (v) Ammeter - 01 Nos (vi) LED type indicator to indicate R,Y,B phase (Main LTP) |
| 35 | S & F and commissioning of outdoor factory made weather and vermin proof, CPRI approved, MS cubical LT panel, fabricated with 3.15 mm thick MS sheet for outer and 1.6 mm thick for inner shell & zinc metal powder coated paint over a coat of primer red oxide and reqd capacity of aluminium bus bar channel insulated with heat shrinkable sleaves and mounted on epoxy insulator of reqd size in conical type, double door be provided with proper hinged incl locking arrangements, provn of suitable cable ducts at bottom and control wire of 2.5 sqmm multi stranded copper conductor with adequate size of lugs be properly bunched. The cubical panel be fixed on PCC (1:2:4) type B1 foundation of reqd size. The compart-mentalized to accommodated to incomer and outgoing MCCBs, MCB\"s and measuring eqpt and separate door will cover to each MCCB incl suitable space for accomodate the followings :- (a) Incomer - MCCB 4 pole 400 Amp, 50 Hz 415 V AC with rupturing cap 50 KA - 01 Nos (b) Outgoing -(i)MCCB 4 pole 125 Amps 50Hz 415 Volt AC 16 KA -02 Nos (ii) MCCB 4 pole 63 Amps 50Hz 415 Volt AC 16 KA -02 Nos(iii) Aluminium bus bar 300 Amp 04 Nos -01 Set (iv) Voltmeter - 01 Nos (v) Ammeter - 01 Nos (vi) LED type indicator to indicate R,Y,B phase (Fire Fighting) |
| 36 | S & F and commissioning of outdoor factory made weather and vermin proof, CPRI approved, MS cubical LT panel, fabricated with 3.15 mm thick MS sheet for outer and 1.6 mm thick for inner shell & zinc metal powder coated paint over a coat of primer red oxide and reqd capacity of aluminium bus bar channel insulated with heat shrinkable sleaves and mounted on epoxy insulator of reqd size in conical type, double door be provided with proper hinged incl locking arrangements, provn of suitable cable ducts at bottom and control wire of 2.5 sqmm multi stranded copper conductor with adequate size of lugs be properly bunched. The cubical panel be fixed on PCC (1:2:4) type B1 foundation of reqd size. The compart-mentalized to accommodated to incomer and outgoing MCCBs, MCB\"s and measuring eqpt and separate door will cover to each MCCB incl suitable space for accomodate the followings :- (a) Incomming - MCCB 4 pole 125 Amp, 50 Hz 415 V AC with rupturing cap 50 KA - 01 Nos (b) Outgoing -(i)MCCB 4 pole 63 Amps 50Hz 415 Volt AC 16 KA -02 Nos (ii) MCCB 4 pole 40 Amps 50Hz 415 Volt AC 16 KA -02 Nos(iii) Aluminium bus bar 300 Amp 04 Nos -01 Set (iv) Voltmeter - 01 Nos (v) Ammeter - 01 Nos (vi) LED type indicator to indicate R,Y,B phase (For ESH) |
| 37 | S&F of kiosk box for luminaires ,weather proof made out of PVC/HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded andcover with hinged door, pole mounting type comprising of 4 pole copper connectors of 16 Amps with 6 Amp MCB single pole , of minimum size of panel is 300x200x125mm, IP 54 fixed on pole with MS, clamps 30x5mm with necessary nuts, washerMake Sintex/Universal SG/Finplex/Hansel and incl. applying two coats of synthetic enamel paint over ared oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box complete all as directed. |
| 38 | M&L for laying 20 mm graded stone aggregate & stone dust in substations insuch a way that after removing of unwanted grass from substations and then levelling at zero level and laying of stone dust of 50 mm thick at an initial layer and then laying of 20 mm gaded stone aggregate 100 mm thick over the stone dust. The quoted rate also includes cleaning and levelling and filling of sub station before laying aggregate. The complete work shall be as decided and directed by engr in charge. |
| 39 | M & L for black toproad cutting incl excavation in trenches for laying HT/LT UG cable in pipe not exc 45 cm wide and n.exc 60 cm depth or as per site requirement including making good the disturbed surfaces with cement concrete (1:3:6) type C-1 and top surface neatly finished as per existing to match with the existing complete all as specified and directed. |
| 40 | S & F of cable path indicator made up of precast RCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate of size 800X400 X 50 mmand 8mm steel bars in rcc dulyl painted withyellow colour and marked/writtenas HT/LT cable as directed and fixedat 600 mm above and 300 mm below ground levelalong with cable route complete all as specified and directed. |
| 41 | EXTERNAL WATER SUPPLYMasonary valve chamber for 1050 mm x 1050 mm x 950mm (internal dimensions)including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate foundation, brick work in CM (1:6) plastering internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type C1 coping 50 x50x6 mm angle iron 6 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as shown on drawing and as specified. |
| 42 | Masonary valve chamber for 950 mm x950 mm x 950 mm (internal dimensions)including excavation and earth work in any type of soil and 100 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate foundation, brick work in CM (1:6) plastering internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type C1 coping 50 x50x6 mm angle iron 6 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer all as shown on drawing and as specified. |
| 43 | S&F valve, stop, screwed 25 mm dia pipe complete all as specified and as directed. |
| 44 | S&F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 150 mm dia bore and fixing up in Cast Iron Water supply mains of size 150 mm dia complete all as specified and as directed.. |
| 45 | S&F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia complete all as specified and as directed.. |
| 46 | S&F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 80 mm dia bore and fixing up in Cast Iron Water supply mains of size 80 mm dia complete all as specified and as directed. |
| 47 | S & Fof CI foot valve 150 mm dia as per IS 4038 flanged type double door casting ring & rubber flap CI including fixing on GI/CI pipe with nut boltas per requirement at site suitable for cast iron pipe/ ductile iron pipe/GI pipe incl all fittings washer, nuts & bolt etc complete all as specified and directed. |
| 48 | S & F of NRV cast iron double flanged swing type having GM body seat and rubberised disc seat150 mm dia as per IS 5312 flanged type fixing on GI/CI pipe with nut boltas per requirement at site suitable for cast iron pipe/ ductile iron pipe/GI pipe incl all fittings washer, nuts & bolt etc complete all as specified and directed. |
| 49 | Supply, installation, testing and commissioning of multistage centrifugal pumping set 30 HP/24 KW electric driven AC, 415 volt 50 Hzof head 80 mtr delivery discharge 850 LPM having CI casing and stainless steel impeller suction / delivery 150/100 mmincluding necessary foundation, channel section, mouting pad capable to bear full load complete all as specified and directed. |
| 50 | S&F single core multistranded copper conductor HRFR of size 16 sqmm from motor to starter complete all as specified and as directed. |
| 51 | Taking down existing GI pipe of 100/80 mm dia for rerouting/replacing all as specified and directed. |
| 52 | FIRE FIGHTINGS&F ,Testing and Commissioning Air Release Valve 100 mm , with 100 mm dia air valve ( Ball Type) 50 mm dia stop valve, with Flange , Nipple , Tees , Elbows other Accessories Complete all as Specified . (for Delivery Header) |
| 53 | Supply , Installation , Testing and Commissioning Electric Control Panel for Diesel Engine , Main Pump , Jockey Pump etc. 1 Nos 100 HP + 1 Nos 15 HP + 1 Nos 12 v Diesel Engine . for Ring Line Pump. |
| 54 | Supply , fixing, testing and Commissioning of Water Monitor PN 1.6 ,1750 LPM Cast Iron with Gun Metal Nozzle conforming to IS 8442:1977 ISI Marked, made out of gun metal with 80 mm did flanged inlet . 360 Degree rotation , instantaneous Handle lock arrangement with Flanged , Rubber Gasket , Nuts , Bolts etc, Complete all as specified and as directed. |
| 55 | Cost of Civil Works with MS Structure Height 12 feet ( 50 mm Angle / Square Bar)220 Pillars ( Approx ) For Fire Sprinkler line. |
| 56 | Supply, installation, testing & commissioning of monoblock centrifugal pumping set of capacity 3 HP (1.44 WHP) capacity discharge 500 LPM, head 20 mtr, elecric driven, AC 3 phase Confirming to IS – 12469:1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearing with starter, connection cable complete all specified and directed. |
| 57 | S & Fof CI foot valve 150 mm dia as per IS 4038 flanged type double door casting ring & rubber flap CI including fixing on GI/CI pipe with nut boltas per requirement at site suitable for cast iron pipe/ ductile iron pipe/GI pipe incl all fittings washer, nuts & bolt etc complete all as specified and directed. |
| 58 | S & Fof CI foot valve 100 mm dia as per IS 4038 flanged type double door casting ring & rubber flap CI including fixing on GI/CI pipe with nut boltas per requirement at site suitable for cast iron pipe/ ductile iron pipe/GI pipe incl all fittings washer, nuts & bolt etc complete all as specified and directed. |
| 59 | S&F 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and directed. |
| 60 | S&F Fire point comprising of following:- (a) Fire Extinguisher Water CO2 / Stored Pressure Type - 02 Nos9 Ltr cap (IS:15683) (b) Fire ExtinguisherDry Chemical Powder (ABC) Type, - 01 No 9 Kg capacity (IS : 15683) (c) Fire ExtinguisherCOO Type, 4.5 Kg capacity-01 No (d) Ceiling Hook (IS : 927)-01 No(e) Fire Beater -02 Nos(f)Fire Bucket (Water/Sand)-01 No(g) Shovel (GS)- 01 No(h) Fire Gong / Hand Siren-01 No(j)Fireman Axe -01 No |
| 61 | DG SETSilent engine generating set with accoustic enclosure as per CPCB IV norms 415 volts 320 KVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 with and including the following:-(i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test (A) Alternator :-Standard design alternator rated at 320 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC,3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class \"H\" and voltage regulation of+/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722Item Continued as 14.36 to 14.41 |
| 62 | i) Insualation class - \"H‘ ii) Temparature rise Class - \"H‘iii) Excitation : Self Excitediv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5%v) Frequency regulation +/- 1%(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under ii) Cooling system :- Moulded radiator with fan & beltsiii) Cooling Water pump : - Centrifugal type belt driveniv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. |
| 63 | Exhaust gas turbo charger type. Exhaust manifoldSilencer : Residual type Bellowsiv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters,Fuel hoses.v) Lub oil System : Lubricating oil filter Lubricating oil pump vi) Air Intake System :Air intake ManifoldAir cleaner dry typevii) Governor :- Electronic Governorviii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator (ix) Corrosion inhibitor coolantPaper element filters for fuel, lub oil and by passElectronic governor controlled direct fuel injection system Fly wheel housing and fly wheel Corrosion inhibitor coolantPaper element filters for fuel, lub oil and by passElectronic governor controlled direct fuel injection systemFly wheel housing and fly wheelx) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standardpractice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display. |
| 64 | (v) Fuel System :- Diesel Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by governer electronic operated/ (as recommended by OEM) for 1% speed /frequency regulation. Comprising with Fuel Filters and Fuel Hoses.(vi) Lub oil System :-Comprising of Lubricating oil filter, Lubricating oil pump etc.(vii) Air Intake System :- Air intake Manifold, Air cleaner dry type etc(viii) Governer : - Electronic type(ix) Starting System :- Electric Self starter with and including battery charging alternator 12 Volts DC.(x) Batteries :- Batteries of maintenance free 180 AH - 02 Nos of voltage as per OEM complete with copper conductor multistranded leads of suitable length fromself starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified.Start and stop push buttonIgnition key / SwitchRadiator with blower fan & first fill of coolant oilCorrosion inhibitor coolant(xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. |
| 65 | xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of enginexii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible couplingxiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform.xiv) Base Frame : - Should be provided as OEM normsxvi) MS pipe line to and from the fuel tank to the DG Set C) AMF Panel :- Factory made inbuilt type control cubical type made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 320 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standardstandard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc g) Annuciation with indication lamps for : (i) Low lub oil pressure. (ii) High Water Temparature. (iii) Engine over speed. (iv) Battery low voltage Controls :-a) Load on Indicationb) Load off indicationc) Engine start push buttond) Engine stop push buttone) Fault accept / reset push button |
| 66 | f)Battery charger(i) Transformer shall be dry type, double wound, with copper conductor andClass–B insulation with temperature rise limited to Class-A insulation.(ii) Isolating switch shall be heavy duty, load break type, operated by an externalhandle.(iii). Fuses shall be HRC type and arranged for easy replacement. Semiconductingdevices fuses shall be fast-acting type.(iv). Indicating meters (voltmeter and ammeter) shall be 96mm x 96mm, flush type90 degree scale with antiglare glass, + 1% accuracy with zero adjuster on thefront of the meter.(v.) The following indications/alarm annunciation shall be provided:a) Failure of input AC supply to the chargerb) Low battery voltagec) DC output fuse blownd) Charger faile) Over voltagef) Earth faultg) Battery on boost chargedirected.(v) DC Ammeter (vi) Charger rate selector switch |
| 67 | (D) Accoustic Enclosure:-Manufactured by OEM suitable for 320 KVA DG Set(i) NAL approved as per CPCB(ii) It Should be as per latest rules and regulations of Ministry of Environment andPollution control board(iii) The generating setbattaries and control panel should be inside the enclosure.(iv) Construction Details/specification are as follows:a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Normsv) The accoustic should be composite in construction and fully assembled integral unitvi) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated vii) The DG Set should be provided with external Emergency stop push buttonviii) The enclosure should be suitably illuminated by CFL/FTL Lamp fittings.ix) The noise level should be 75 dba at 1m under free field conditions.x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shadeE) The quoted rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete for placing of DG Setcomplete all as specified and directed |
| 68 | S & F and commissioning of outdoor factory made weather and vermin proof MS cubical LT panel, CPRI approved, fabricated with 3.15 mm thick MS sheet for outer and 1.6 mm thick for inner shell & zinc metal powder coated paint over a coat of primer red oxide and reqd capacity of aluminium bus bar channel insulated with heat shrinkable sleaves and mounted on epoxy insulator of reqd size in conical type, double door be provided with proper hinged incl locking arrangements, provn of suitable cable ducts at bottom and control wire of 2.5 sqmm multi stranded copper conductor with adequate size of lugs be properly bunched. The cubical panel be fixed on PCC (1:2:4) type B1 foundation of reqd size. The compart-mentalized to accommodated to incomer and outgoing MCCBs, MCB\"s and measuring eqpt and separate door will cover to each MCCB incl suitable space for accomodate the followings :- (a) Incomer - MCCB 4 pole 400 Amp, 50 Hz 415 V AC with rupturing cap 50 KA - 02 Nos (b) Outgoing - (i)On load changeover switch 315 Amp 4 pole -01 Nos (ii)MCCB 4 pole 250 Amp, 50 Hz 415 V AC with rupturing cap 50 KA - 01 Nos (ii)MCCB 4 pole 100 Amp, 50 Hz 415 V AC with rupturing cap 25 KA - 03 Nos(iii) Aluminium bus bar 600 Amp 04 Nos -01 Set (iv) Voltmeter - 01 Nos (v) Ammeter - 01 Nos (vi) LED type indicator to indicate R,Y,B phase (For DG) |
| 69 | M&L for earthing complete with galvanised steel earth plate electrode of size 600X600X6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below the ground level connected to galvanised iron strip of 32x6 mm as earth lead by means ofbolts nuts check nuts & washers of galvanised iron or steel ,surrounded by charcoal of coke and salt, protected by GI pipe 40 mm bore (light grade), water pipe 20mm bore GI medium grade with funnel and wire mesh,and making chamber of PCC (1:4:8) type D-2 using 40 mm graded stone aggregate and coping shall be in PCC(1:3:6) type C-1 using 20 mm graded stoneaggregate, 50 mm thick cover of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate, reinforced with 8 mm dia TMTbars @ 80 mm c/c boath ways including excavation and earth work and removal of surplus soil todistance n exc 50 m complete all shown in electrical plate No 3of SSR part- 2010 and also including making test point for testing of earthingmade out ofgun metal or phosphorous bronge size 75x75x25 mm complete all as specified and directed. |
| 70 | PROVISIONAL SUM |
| 71 | Construction of Precast RCC M-25 Dunnage block of size 300 mm x 300 mm x 200 mm each and place it to position / location as directed by the Engineer-in-Charge.(5472 Nos)TOTAL AMOUNT = ₹ 53,62,560.00 Add/deduct__________%(___________percent) ₹____________ Above/belowBidder to quote total amount after considering percentage addition/deduction over pre-priced amount to cover market variation, over head and profit etc. NOTE : The amount shown is approximate. The exact requirement of the items will be finalized during execution of the work and the pricing will be carried out based on rate adjusted with the quoted percentage. |
| 72 | Construction of Fire Point complete all as specified and directed. (05 Nos.)TOTAL AMOUNT = ₹ 2,10,000.00Add/deduct__________%(___________percent) ₹____________ Above/belowBidder to quote total amount after considering percentage addition/deduction over pre-priced amount to cover market variation, over head and profit etc. NOTE : The amount shown is approximate. The exact requirement of the items will be finalized during execution of the work and the pricing will be carried out based on rate adjusted with the quoted percentage. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |