| 1 | CLADDING WORK |
| 2 | Providing and Fixing Armstrong or equivalent Channelled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a \"Helmholtz\" fluted perforation with consecutive 3mm wide groove followed by 21mm of visible pane. The edges of the panel shall be \"tongue-and-grooved\" to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.5. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm. The panels shall be mounted on special aluminium splines (keel) using inside clips provided by Armstrong and approved by the Architect/ Engineer-in-Charge. |
| 3 | STEEL WORK |
| 4 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 5 | Steel work in built up tubular (round, square or rectangular hollow tubesetc.)trussesetc.,includingcutting,hoisting,fixingin position and applying a priming coat of approved steel primer, including welding andbolted withspecial shaped washers etc. complete. |
| 6 | GI Tubular TATA or equvalent |
| 7 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 8 | FLOORING |
| 9 | Crazy marble stone flooring, including filling the gaps with light shade pigment with white cement marble powder mixture (3 parts of white cement : 1 part of marble powder) by weight in proportion of 4:7 (4 cement marble powder mix : 7 white, black or white and black marble chips of sizes from 1 mm to 4 mm nominal size by volume), with under layer 25 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size), including rubbing, polishing and cement slurry etc. complete : |
| 10 | 18 mm thick crazy marble stone white, black or as specified |
| 11 | Supplying and paving best quality highly compressed exterior grade floor paving tiles in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 12 | ROOFING |
| 13 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws cmplete: |
| 14 | Ridges plain (500 - 600mm) |
| 15 | Providingandfixingtiledfalseceilingof specifiedmaterialsof size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet,1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like difusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 16 | 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coeficient) of 0.79 |
| 17 | Providing and fixing in roof with necessary self tapping screwssandwich panel Trafford roofing sheet with total thickness of 50mm with polyurethane foam of Density 36 Kg/cum plus or minus 2 Kg/cum with thermal conductivity with ofless than or equal to 22 MW/MK and form tensile strength (adhesion) at 80C Greater than or equal to 80Kpa and youngs modulus at 80Cgreater than or equal to 2500 Kpa sandwiched between two GI sheets. The external and internal sheet shall have thickness of 0.40mm and 0.30mm respectively. The external and internal sheet shall be JSW/TATA/Bhushan/LLoyds equivalent make having a minimum 150 GSM galvalume coating pre-painted with approved colour and shade by the Engineer in charge with an SMP coating of 18 microns over epoxy coats of 7 microns |
| 18 | Providing square type UPVC gutter with necessary clamps, bolts, nuts and specials such as nozzles sockets stoppers etc. including cost and conveyance of all materials and labour charges etc. complete as per the instructions of the dept. officers |
| 19 | 200mm or equivalent Square type UPVC |
| 20 | Providing and fixing precoated galvanised iron (GI) sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 21 | Ridges, hips or valley |
| 22 | FINISHING |
| 23 | 12 mm cement plaster of mix : |
| 24 | 1:4 (1 cement: 4 fine sand) |
| 25 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 26 | 1:3 (1 cement: 3 fine sand) with the addition of colouring compound(red oxide) with thread line. |
| 27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 28 | Water thinnable cement primer |
| 29 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. |
| 30 | On steel work |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 32 | Two or more coats on new work |
| 33 | Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture. |
| 34 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 35 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 36 | Two coats |
| 37 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 38 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 39 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
| 40 | Dismantling and Demolishing |
| 41 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 42 | G.S. Sheet |
| 43 | Dismantling cement asbestos or other hard board ceiling or wall panelling including frame work and stacking of serviceable materials within the campus and disposal of unserviceable materials outside the campus at contractor\"s account including frame work. |
| 44 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground outside the campus at contractor\"s account. |
| 45 | Dismantling interlock paver tile carefully, including cleaning and stacking of serviceable material in the engineering unit store and disposal of unserviceable material outside the campus at contractor\"s account or as per the instruction of engineer-in-charge. |
| 46 | ROAD WORK |
| 47 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design& shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 48 | WATER SUPPLY |
| 49 | Providing and fixing Polyvinyl Chloride (PVC) pipes, including all PVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 50 | 110 mm nominal dia Pipes (4kg/cm2) |
| 51 | WATER PROOFING |
| 52 | Providing and laying water proofing treatment over the concrete surface by applying cement based two component polymer modified water proofing slurry coating coating (SIKA 109 TOP seal or equivalent)after cleaning the surface free from scale, rust, grease, oil etc. preparing the surface to be true and flat and saturatedmixing the liquid (A) and powder (B) components in the ratio 1:4 by weight, applying in two coats with an interval of 2 to 6 hours for hardening in between and finally finished by rubbing down with a soft, dry sponge including protecting the applied surface from direct sunlight and storng wind and curing by gunny bags or polythene sheeting upto 5 days etc. complete. |
| 53 | NEW TECHNOLOGIES AND MATERIALS |
| 54 | Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channelsection of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finallycalcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer\"s specification as per direction of Engineer-in-Charge all complete. |
| 55 | With 15 mm thickfully perforated square/butt edge light weight calcium silicate panels/ tiles |
| 56 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. including cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry and including providing, mixing and applying bonding coat of epoxy bonding adhesive (Nitobond EP or Equivalent) having coverage 2.20 sqm/kg of approved make on chipped portion of RCC as per specifications complete in all respect. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. |