| 1 | Earth work in excavation in foundation trenches or drains (exceeding 1.5M in width as well as 10Sqm on plan) including dressing of sides ramming of bottoms lift up to 1.5M including getting out the excavated soil and disposal of surplus excavated soil within a lead of 50M from edge of cutting complete. |
| 2 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. Ordinary Rock |
| 3 | Providing and laying Stone solling /boulders Hand packed including compacting, watering including all carriages of material complete. |
| 4 | Filling Availble Excavated earth in trenches , plinth , sides of foundation etc in layers not exceeding 20cm in depth consolidating each layer by ramming and watering lead upto 50m and lift upto 1.5m |
| 5 | Providing & Laying of Nallah Muck filling including watering dressing and ramming with all carriages and headload, loading un-loading and stacking etc complete |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level (1:4:8) (1Cement: 4 fine sand: 8 grade stone aggregate 40mm nominal size).incl all carriage and headload. |
| 7 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement all work up to all levels(.1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size) Crushed. (All Works up to Plinth level) incl. all carriage and head load. |
| 8 | Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering. All work up to plinth level1:3:6 (1Cement: 3 fine sand: 6 grade stone aggregate 20mm nominal size)incl all Carriages and Headload. |
| 9 | R.R Stone masonary laid in dry with nallah stones in S. pit incld carriage by MT. |
| 10 | Centering and shuttering including strutting propping etc. removal of form work in Raft,foundation, bases of columns and plinth (All works upto Plinth level) |
| 11 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) incl all Carriages and Headload. |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) incl all Carriages and Headload. |
| 13 | Brick work with FPS bricks of class designation 75 in super structure up to all floors. Including carraige of Bricks In cement mortar 1cement: 6 fine sand mortar.incl all Carriages and Headload. |
| 14 | Providing and fixing of wood work in frames of door/ window /arch windows /ventilator wrought frames (chowkats) imported klin Dried Wood incl all Carriages and Headload. |
| 15 | Providing & fixing of 40x5mm flat iron hold fast 40cm long including fixing to frameswith 10mm dia bolts nuts &wooden plugs and embedding in cement conc block 30x10x5cm 1:3:6mix (1cement:3coarse sand:6 graded st agg)20mm nominal size |
| 16 | Supplying, cutting, bending to shape, fabricating, fixing and tying in position TMT Reinforcement Steel at all levels and location as shown in the structural drawing,tying reinforcement with GI binding wire. all carriage and headload |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 18 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 19 | Columns, pillars, piers, abutments, posts and struts. |
| 20 | Structural steel work welded in built up sections and frame work including cutting, hoisting fixing in position all complete in angles / flats / tubes including MS sheet for chejja,soffits and eveas boarding complete job etc.incl all carriage and headload |
| 21 | Providing and Fixing color coated High Rib Colour coated C.G.I sheet roofing including cost of j-hooks, washers nails 0.50mm thick. Including cost of overlapped sheets complete job.incl. all carriage and headload |
| 22 | Providing and Fixing of ridges hips / valleys ornamental of colour G.I sheets including cost screws/washers all complete job. |
| 23 | 12 mm thickcement Plaster in 1:6 mixture including all carriages and costs. |
| 24 | Applying2mm thick wall putty on wall surfaces including all carriages and costs. Interior only |
| 25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work (two or more coats) over and including priming coat with cement primer |
| 26 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 27 | Providing and fixing of 35mm thick panelled glazed shutters for window including cost of MS butt hinges and screws all complete job. Second class kail wood |
| 28 | Applying Priming coat with ready mixed colour primer of approved brand and manufacture on wood work. |
| 29 | Painting with synthetic enamel paint to give an even shade two or more coates of approved brand and manufacture on wood. |
| 30 | Providing and fixing of hardware items of ISI Marked of standard quality and make.Handles 150mm |
| 31 | T bolts 150mm |
| 32 | alrdrop with Concealed Locks |
| 33 | T Bolts 150mm |
| 34 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete.Size of tile 600x600 mm |
| 35 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, EliteBrown, Cat Eye or equivalent. |
| 36 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 37 | Providing and fixing one fan point includes wiring for lighting points in 1.5sqmm pvc insulated copper wire and 2.5sqmm pvc in multi -strant copper wire 1200mm ceilling fan electronic fan dimmer.6Amp s pole MCB-10AMP DP MCB 2 Way DB for housing MCB or lightting circuits and hylem sheet.including Placing and fixing in position Fan clamp boxes with MS Fan clamps connected with network Conduit pipes with necessary fittings in RCC Work |
| 38 | Heating point (one heatting point includes wiring of lighting point in 2.5 sq.mm PVC insulated copper wire and 4.00 sq.mm PVC insulated multistrand copper wire,16 amp one way swittch,10 amp S pole MCB,2 way DB MCB and hylem sheet.including Placing and fixing in position deep junction of cast iron with network Conduit pipes with necessary fittings in RCC Work.including cost of service line as directed by engineer incharge. |
| 39 | Lighting point (one lighting point includes wiring of lighting point in 1.5 sq.mm PVC insulated copper wire and 2.5 sq.mm PVC insulated multistrand copper wire,6 amp one way swittch6 amp S pole MCB,10 amp DP MCB,2 way DB MCB and hylem sheet with 16/15 Watt LED surface lights.including cost of channelsas per requirement.One point controlled by one 6 amp switch.( upto 10 meters)including Placing and fixing in position 25mm PVC Conduit pipes with necessary bends and other fittings in RCC Work. |
| 40 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (forpayment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 41 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer)PN-16 pipe , OD(SDR-7.4) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge, Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall incl all necessary fittings , bends , tees, reducers etc20mm incl. Unions etc |
| 42 | 25mm incl. Unions |
| 43 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality 20 mm nominal bore |
| 44 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 45 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap incl pedestal |
| 46 | P/F of PVC pipe for sewage/outlet of bathroom incl all necessary fittings bends , collar, p trap, s trap , carriage etc75mm |
| 47 | 100mm |
| 48 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 49 | P/F of following C.P fittings of approved brand and make (Parko, Jaguar, hindware ) or equavallent including all complete.Angle Cock |
| 50 | C.P Nipple |
| 51 | C.P Grating |
| 52 | Towel Rail |
| 53 | Making plinth protection50 mm thick of cement concrete 1:3:6 with 20 mm nominal size aggrigates over 75 mm bed of dry brick ballast 40 mm nominal size well rammed, consolidated & grouted with the fine sand i/c finishing the top smooth |
| 54 | Constructing brick masonry chamber for underground C.I. inspectionchamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick withcement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line |
| 55 | Providing and placing on terrace polythene water storage tanks ISI 12701 marked indicating the BIS license no with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and base support |
| 56 | Providing Float glass panes 3.5 mm thick in doors windows and clerestory window shutters (Area of opening for glass panes excld portion inside shall be measured) Please Enable Macros to View BoQ information |