Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-01-2026 | Date Extension for Construction of Transit Quarters for Medical Personnel at CHC kangpokpi, Manipur | Date | 10-02-2026 |
| Sl. No. | Item Description |
| 1 | EARTH WORKS |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. |
| 3 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All Kinds of Soil |
| 4 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 5 | Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating & dressing complete. |
| 6 | CONCRETE WORKS: |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: 1:4:8 (1 Cement:4 coarse sand:8 graded stone aggregate: 40 mm nominal size) |
| 8 | Providing & laying damp-proof course 50 mm thick with cement concrete cement concrete 1 : 2 : 4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 9 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 10 | R.C.C. Work :Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level: 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : a) 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 12 | R.C.C. work in beams, suspended floors, roofs having slope uptp 15o landings, balconies, shelves, chajjas,lintels, band, plain window sills, staircases and spiral staircases above plinth level upto floor fivelevel excluding the cost of centering, shuttering, finishing and reinforcement, with 1 : 1 .5: 3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 13 | FORM WORK :Centering and shuttering including strutting,propping etc.and removal of form for : |
| 14 | a)Foundations, footings, bases of columns, etc. for mass concrete |
| 15 | b) Columns, pillars, posts and struts |
| 16 | c) Lintels, beams, plinth beams, girders, bressumers and sqm cantilevers |
| 17 | d) Suspended floors. roofs, landings, balconies and access platform, with water proof ply 12mm thick. |
| 18 | e) Stairs, (excluding landings) except spiral-staircases |
| 19 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. a) Thermo-Mechanically Treated bars |
| 20 | BRICK WORKS:: Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: a) Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 21 | Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in a) Cement mortar 1 : 3 (1 cement : 3coarse sand) |
| 22 | Honey-comb brick work 10 / 11.4 cm thick with common burnt clay bricks of class designation 7.5 in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand). |
| 23 | STONE WORK: Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and cement slurry @ 3.3Kg/Sqm i/c pointing in white cement complete. 8 mm thick a) Raj agar plain white marble/Udaipur green Marble/Zebra black marble |
| 24 | WOOD WORKS: Providing wood work in frames of doors, windows, clerestory windows and other frames.wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separatelya) Local best quality teak wood |
| 25 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge Local best quality teak Wood a)35 mm thick Shutters |
| 26 | Providing paneling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling tor panelled or panelled and glazed shutters 25 mm to 40 mm thicka) Local best quality teak Wood |
| 27 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 28 | Providing and fixing bright finished brass door latch with necessary screws etc. complete a) 250 x 16 x 5 mm |
| 29 | Providing & fixing bright finished brass Tower bolts (barrel type) with necessary screws etc. complete. a) 250x10 mm |
| 30 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 31 | Providing and fixing chromium plated brass handles with necessary screws etc. complete:a) 125 mm |
| 32 | STEEL WORKS Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. a) Hot finished welded type tubes |
| 33 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.a) M.S. tube |
| 34 | FLOORING: Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 35 | Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete. a) Marble tiles (polished) Raj Nagar |
| 36 | Marble stone flooring with 18mm thick marble stone (sample Of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with (a) Raj Nagar Plain |
| 37 | Extra for prefinished nosing to treads of steps of marble stone. |
| 38 | Providing and fixing 1st quality ceramic glazed wall tiles conformingto IS : 15622 (thickness to be specified by the manufacture of approved make in alt colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (I cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 39 | Providing and laying Vitrified tiles in floor in diffe rent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.080/0 and conforming to 19.15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will bo done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. a)Double charge vitrified tile polished finish of size Size of tile 600x600 |
| 40 | ROOFING : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. a) Precoated galvanised iron profile sheets 0.5mm thick |
| 41 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : a) Ridges plain (500 - 600mm)Precoated galvanised iron profile sheets 0.5mm thick |
| 42 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 43 | a) 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3) : 1996 (Board with BIS certification marks) |
| 44 | FINISHING: 12 mm cement plaster of mix 1:4 (1 cement:4 coarse sand). (a) (1 cement:4 coarse sand) |
| 45 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement:4 coarse sand). (a) 1:4 (1 cement:4 coarse sand). |
| 46 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. (a) New work(two or more coats)over and including priming coat with cement primer |
| 47 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface(a) Water thinnable cement primer |
| 48 | Finishing walls with textured exterior paint of required shade: (a) New Work(two or more coats applied @3.28ltr/10 Sqm)over and including base coat of water proofing cement paint [email protected]/10 sqm. |
| 49 | Applying priming coat:- (a) With ready mix pink or grey primer of approved brand and manufacture on wood work(hard and soft wood) |
| 50 | Painting (two or more coats) with synthetic enamel paint of approved brand and manufacture to give an even shade. (a) Two or more coats on new work |
| 51 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaece to prepare the surface even and smooth |
| 52 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in charge. (Glazing, paneling and dash fastenersto be paid for separately) : a) For fixed portiom Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 53 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) a) For fixed portiom Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 54 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directionsof Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): a) For fixed portiom With float glass panes of 5.50 mm thickness |
| 55 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All Kinds of soil |
| 56 | Filling available excavated earth (excluding rock) in trenches. plinth, sides offoundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layerby ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 57 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: |
| 58 | a) ( 1 Cement.• 3 coarse sand 6 graded stone aggregate 40 mm nominal size) |
| 59 | b) 1:4:8 ( 1 Cement: 4 coarse sand 8 graded stone aggregate 40 mm nominal size) |
| 60 | FORM WORKS: Centering and shuttering including strutting, propping etc. and removal of form for: a) Foundations, footings, bases of columns, etc. for mass concrete |
| 61 | b) Suspended floors, roofs, landings, balconies and access |
| 62 | RCC WORKS: Reinforced cement concrete work in beams, suspended floors, roofs having stope upto 15landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 63 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.a) Thermo-Mechanically Treated bars |
| 64 | PRE-CAST: Providing, hoisting and fixing upto floor five lovol procast reinforced comont concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the tike including tho cost 01 required contoring, shuttering but excluding cost of reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand: 3graded stone aggregate 20mm nominal size). |
| 65 | Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: cum Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 66 | Half brick masonry with 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 67 | Honey-comb brick work 10/11.4 cm thick with 1st class common burnt clay FP.S. (non modular) bricks in superstructure above plinth level and upto floor V level in cement mortar 1 : 4 ( 1 cement : 4 coarse sand) |
| 68 | Flooring: Cement concrete flooring 1:2:4 (I cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost Of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate. |
| 69 | Cement plaster skirting (upto 30 cm height) with cement mortar 1:3 (I cement : 3coarse sand) finished with a floating coat of neat cement 18 mm thick |
| 70 | SANITARY INSTALLATION :Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with scat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever). conforming to IS : 7231. with all fittings and fixtures complete. including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 71 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:White Vitreous China Wash basin size 550x400 mm with single 15 mm C.P. brass pillar taps |
| 72 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :16.9.1 Kitchen sink with drain board. 16.9.1.1 510x1040 mm bowl depth 250 mm |
| 73 | Providing and fixing a mm dia C.P. / S.S Jet with flexible tube upto 1 metre tong with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 74 | Providing and fixing P.V.C. Waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia |
| 75 | Providing and fixing 600x450 mm beveled edge mirror of superior 1,053.30 glass (Of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass scrows and washers complete. |
| 76 | Providing and fixing PTMT liquid soap container 109 mm wide, 125each 195.80 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 77 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 78 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 79 | Providing and fixing PVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fitting with solvent cement, tenching, refilling & testing of joints complete as per direction of Engineer in charge a) 75 mm dia |
| 80 | Providing and fixing PVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fitting with solvent cement, tenching, refilling & testing of joints complete as per direction of Engineer in charge b) 110 mm dia |
| 81 | Water Supply :Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. For External work32 mm dia nominal bore |
| 82 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work. including cutting chases and making good the wall etc. |
| 83 | a) 20 mm diameter |
| 84 | b) 25 mm diameter |
| 85 | c) 32 mm diameter |
| 86 | Providing and fixing G.l. pipes complete with G.l. fittings including trenching and refilling etc. External work a) 32 mm diameter |
| 87 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm diameter |
| 88 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete a) 25 mm diameter |
| 89 | Providing and placing on tcrrace (at all floor levels) polyethylene per litre 10.20 water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and tho baso support for tank. |
| 90 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points Of approved quality conforming to IS:893115 mm nominal bore |
| 91 | Wiring for light/Fan point/Exhaust Fan point/Call bell point with 1.5mm²FRPVC insulated copper conductor single core cable in surface/recessed steel conduit with modular type switch modular plate,suitable G.I.box and earthing the point with 1.5mm²FRPVC insulated copper conductor single core cable etc.as required. |
| 92 | 1) Gr. A |
| 93 | 2) Gr. B |
| 94 | 3) Gr. C |
| 95 | Suitable size GI box with modular plate and in front on surface or in recess i/c p/f 6 pin 16/15 amp modular socket outlet 15/16 amp modular switch, connection painting etc as required |
| 96 | s/f suitable size G.I box with modular plate and cover infront on surface or recess i/c p/f 3pin 5/6 amp modular socket outlet 5/6 amp modular switch connection painting etc as reqd. |
| 97 | (1.7) Wiring for circuit/sub-main wiring along with earth wire with the (following size of ) FRPVC insulated copper conductor single core cable in surface/recessed steel conduit etc. as reqd. |
| 98 | 2)2x1.5mm²+1x1.5mm² Earthwire |
| 99 | 3)2x4mm²+1x4mm² Earthwire |
| 100 | 4)2x6mm²+1x6mm² Earthwire |
| 101 | 5)2x10mm²+1x10mm²Earthwire |
| 102 | (1.87) S/F (following way) single pole and neutral, sheet steel MCCB DB 240v on surface/recessed complete with tinned copper busbar, neutral busbar, earthbar, dinbar, hinged front acrylie cover for the MCCB knobs datacable grand plate, enter connection, phosphatised and power painted including earthing etc. as required (but without MCB/RCCB/isolator)(1) 2 + 4way |
| 103 | (1.107) S/F 5amp to 32 amp rating 230V “B” series for lighting and other purposes, load of (following poles) in the existing MCB DB complete with connection, testing and commissioning etc. as required.(2) Single pole and neutral |
| 104 | (1.109) S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection testing and commissioning as required. (1) 40 Amp |
| 105 | (1.109) S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection testing and commissioning as required. (2)63 Amp |
| 106 | (1.84) P/F (following capacity TP&N) dis-connector fuse switch unit inside the exiting cubicle panel board with I.S.I mark HRC fuses i/c drilling holes in the cubicle panel board making connection as reqd. |
| 107 | (2) 400 Amp TP&N |
| 108 | (2) 200 Amp TP & N |
| 109 | P/F 400Amp TPN stand ground on load on load change own switch (compact design) 415/500v including connection to as required. |
| 110 | (5.04) S/F Busbar chamber with 4 strips copper busbar of length 900mm suitable for 400 amp capacity complete with all accessoriesi/c connection earthing them body as required |
| 111 | S/F Busbar chamber with 4 strips copper busbar of length 600mm suitable for 2oo amps capacity complete with all accessories i/c connection earthing the body as required. |
| 112 | (8.01) S/F 48” sweep (1200mm)a.c ceiling fan complete with down rod, canopy, 3 Blades but without regulator etc. as reqd. (Havells or similar 5 star) |
| 113 | 305mm sweep exhaust fan complete with all accessories connection etc as required |
| 114 | 1.62) S/F stepped type electronic fan regulator on the modular plate switch box i/c connection but excluding modular plate as reqd. |
| 115 | (1.71) S/F brass batten holder i/c connection etc. as reqd. |
| 116 | LED white lamp 18w |
| 117 | S/F recess mounting LED down lighter BGSL 0301WH 220225 Cast alluminium housing fixed with collinated lens 3x1W white lens mounted on MCPCB extruded alluminium heat sink , spring loaded mounting clips ,complete with connection etc as reqd. |
| 118 | p/f lighting conductor finial made of 25mm dia 300mm long copper tube having single prong at top with 85mm dia 3mm thick copper plate i/c holes etc. Complete as reqd |
| 119 | p/f copper tape in horizontal run p/f copper tape 2ommx3mm thick on parapet or surface of wall for lightning conductor as reqd(for horizontal run) |
| 120 | p/f copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd(for vertical run) |
| 121 | (3.05) Earthing with copper earth plate 600 mmx 600mmx6mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) as reqd. |
| 122 | (3.06) Extra for using Salt & Charcoal for copper plate with electrode as reqd. |
| 123 | Earth connection from earth electrod with 4mm dia in 15mm GI pipe as required |
| 124 | Fabrication of controlled panel board by 16 guage steels sheet along with componets mounting making strip wiring auxillary components wiring all over the panel i/c fixing charge painting etc as reqd. |
| 125 | (18) 9m long steel tubuler pole (410 SP-14) |
| 126 | (1.7) wiring for circuit/ submain wiring along with earth wire with the (following size of) FRPVC insulated copper conductor single core cable in surface/recessed steel conduit etc as reqd3)2x4mm²+1x4mm² Earthwire |
| 127 | (6.01)Laying of 1 no pvc insulated pvc sheated power cable of 1.1KV grade of size not less than 25 sqmm direct in groundi/c excavation , sand cushioning , protective covering and refilling the trench etc as reqd. (3) S/F2.5 m long G.I bracket for fixing street lamp |
| 128 | S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection testing and commissioning as required. (1) 40 Amp |
| 129 | (1.87) S/F (following way) single pole and neutral, sheet steel MCCB DB 240 v on surface /recessed complete with tinned copper busbar, neutral busbar, earthbar, dinbar, hinged front acrylie cover for the MCCB knobs datacable grand plate, enter connnection, phosphatised and power painted including earthing etc, as required ( but without MCB/RCCB/ isolator) (1) 2 + 4 way |
| 130 | (1.107) S/F 5amp to 32 amp rating 230 V \"B\" series for lighting and other purposes, load of (following poles)in the existing MCB DB complete with connection, testing and commissioning etc as required. Single pole and neutral |
| 131 | S/F 50 W LED street lamp . |
| 132 | Sub Head:Fire fighting FIRE HYDRANT & SPRINKLER SYSTEM Supply, erection, testing & commissioning of electrical motor driven Main Pump of horizontal centrifugal end suction backpull out type with gland packing and capable to deliver 2280LPM at 60 MWC.The pump shall be coupled to TEFC motor of approx. 60 HP with speed of 2900 RPM and complete set shall mounted on common base frame. The quoted rate shall includes providing & fixing of coupling, coupling gaurd, RCC foundation( as recommended by manufacturer) and Foundation bolts etc. (for Hydrant & Sprinkler system ) |
| 133 | Supply, erection, testing & commissioning of electrical motor driven Terrace Pump of Monoblock type capable to deliver 900 LPM at 35 MWC.The pump shall be coupled to TEFC motor of 7.5 HP with speed of 2900 RPM and complete set shall mounted on common base frame. The quoted rate shall includes providing & fixing of RCC foundation( as recommended by manufacturer) and Foundation bolts etc. |
| 134 | Supply of External and internal fire hydrant Mild Steel pipe as per IS 1239 Medium & B Class with all fittings, such as bends, elbows,flanges, tees, unions, coupling, expander/redducers, gaskets, nut bolts washers etc. |
| 135 | 150 MM dia |
| 136 | 100 MM dia |
| 137 | 80 MM dia |
| 138 | 50 MM dia |
| 139 | 40 MM dia |
| 140 | 25 MM dia |
| 141 | Supply ofPendent type Sprinkler. |
| 142 | Supply of63 MM dia 15 mtr. long RRL hose pipe with Male & Female Coupling. |
| 143 | Supply of63 MM Short Branch pipe fitted with 25MM Nozzle . |
| 144 | Supply of63 mm dia ISI marked Hydrant valve for Internal/ External landing. |
| 145 | Supply ofFirst Aid Swiming Hose reel drum with 20MM Thermo plast water hose and nozzle. |
| 146 | Supply ofDouble door Glass fronted hose box cabinet suitable for Two hoses and one branch pipe nozzle, with locking arrangement painted red outside and white inside |
| 147 | Fire duct Shutter fabricated out of CRCA and frame, door shall be 900mm x 1200 mm min. & fixed with 4 mm thick Glass, suitable Rubber beedibg and Locking arrangement Quoted rate shall be includes all fasteners etc, and complete shutter shall be powder coated of approved colour both inside and out side. |
| 148 | Supply ofCast iron Butterfly valve 80 MM dia of PN 1.0 rating complete with volt, nuts, compansion flanges. |
| 149 | Supply ofCast iron Butterfly valve 100 MM dia of PN 1.0 rating complete with volt, nuts, compansion flanges. |
| 150 | Supply ofCast iron Butterfly valve 150 MM dia of PN 1.0 rating complete with volt, nuts, compansion flanges. |
| 151 | Supply ofC.I. Non Return Valves Single Plate 80 MM dia PN 1.0 including washer, nut bolt, 1.5 mm thick compressed asbestos gasket companion flanges |
| 152 | Supply ofC.I. Non Return Valves Single Plate 100 MM dia PN 1.0 including washer, nut bolt, 1.5 mm thick compressed asbestos gasket companion flanges |
| 153 | Supply ofC.I. Non Return Valves Single Plate 150 MM dia PN 1.0 including washer, nut bolt, 1.5 mm thick compressed asbestos gasket companion flanges |
| 154 | Stainless steel corrugated 1500 MM flexible pipe(hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating ,25/15 mm dia with union / reducer collar, clamps etc. as required. |
| 155 | Supplying, installing and commissioning of fire brigade inlet connection of 4 way with 4 nos. 63 mm dia. built - in SS 304, Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main as well as to Fire water tank. Quoted rate shall be included with C.I. Butterfly valve, C.I. Non-return valve and CRCA cabinet of suitable size with mounting supports etc. complete. |
| 156 | Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valves with fittings of screwed end type 25 mm dia. |
| 157 | Supply, erection, testing & commissioning of Air Vessel made of 250mm dia, 8mm thick ms sheet, 1200 mm height with air release valve on top and flanged connection to riser , drain arrangement with 25mm dia,with all accesseraries. |
| 158 | FIRE ALARM SYSTEM Supply,installation, testing and commissioning of intelligent Addressable ionisation type photoelectric & Smoke Detectors with dual chamber solid state design, indicating lamp, mounting base etc. as per detailed specification. |
| 159 | Supplying, installing, testing and commissioning of intelligent Addressible Manual pull station with necessary accessories.etc. |
| 160 | Supplying, installing, testing and commissioning of intelligent Addressible Hooter with necessary accessories etc. |
| 161 | Supplying, installing, testing and commissioning of 2 core x 1.5 sq. mm, Armoured cables FRLS type confirming to IS standards and specifications. |
| 162 | Fire Alarm Control panel with Lead acid battery back up for 8 hours normal operation and 15 minutes alarm operation. The control panel, battery charger etc, shall be as per requirement. 4 Loop Panel |
| 163 | HAND APPLIANCES |
| 164 | Supply of 4.5 KG. Capacity CO2 Type Fire Extinguishers. |
| 165 | Supply of 6 KG. Capacity ABC Type Fire Extinguishers |
| 166 | Supply of 09 Ltr. Capacity AFFF Type Fire Extinguishers |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail