| 1 | CIVIL WORKS |
| 2 | OD259113/2025-2026 Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08% and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 1200 x 600 mm |
| 3 | OD259114/2025-2026 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement: 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 1200x 600 mm as per direction from Engineer in charge |
| 4 | OD259131/2025-2026 Steel work in built up GP tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 5 | 50.10.1 Steel work in built up G I tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 6 | 10.25.2 Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 7 | 13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 8 | 4.1.3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | OD259187/2025-2026Supplying Office Table of size 150x75cm using laminated particle board of 12mm thick and top board 18mm thick including all materials and labour charges etc complete as per direction of Engineer in charge |
| 10 | ELECTRICAL WORKS |
| 11 | 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc, as required. (For light plugs to be used in non residential buildings). |
| 12 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc, as required.3 pin 5/6 amp socket outlet |
| 13 | 1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 14 | 1.28.1 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. I or 2 Module |
| 15 | 1.28.2 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 16 | 1.28.4 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module |
| 17 | 1.28.5 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc, as required.8 Module |
| 18 | 1.28.6 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module |
| 19 | 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 20 | 1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 21 | 1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 22 | 1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 23 | OD240171/2025-2026 Supply, Installation, Testing and Commissioning of I ton Split air conditioner and suitable voltage stabilizer with necessary accessories etc. as required |
| 24 | OD240173/2025-2026 Supply, installation, testing and commissioning of 20W LED Tube Light fittings of PHILIPS/ CROMPTON make or equivalent, giving connection on wall/ceilingconforming to relevant ISS etc. complete as required |
| 25 | OD240172/2025-2026 Supply and Installation of dust and vermin proof, 3 phase syntax meter board(GSMB-6535) and to fix KSEB meters, fuse, units etc. as required including fixing it on wall, making good the damages color washing etc. as required |
| 26 | OD240686/2025-2026Supply and Installation of dust and vermin proof, SMC Sintex Meter Box Double Door (GSMB 4422) to fix Single phase KSEB meter, breakers, Fuse units etc. as required including fixing it on wall, making good the damages color washing etc. as required |
| 27 | 19.1 Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC), class of insulation B, 3 no:s blades, 30 cm long down rod, 2no:s canopies, shackle kit, safety rope, copper winding, power factor not less than .9, service valie (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min, 350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts, washers, temperature rise equal to 75 deg celsius (maximum), insulation resistance more than 2 Megaohm, suitable for 230V,50 Hz, single phase AC supply, earthing etc., complete as required: |
| 28 | 1.45 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 29 | 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 30 | OD240199/2025-2026 Supply and Installation of Bulk head light suitable for fixing on outdoor walls giving connections etc. as required |
| 31 | 2.10.1 Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \"\"C\"\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 32 | 2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 33 | 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 34 | OD240200/2025-2026Supply, conveyance, installation, testing and commissioning of the 150 mm size of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3core round copper conductor flex wire conforming to relevant ISS.--<br>: |
| 35 | 90.4.8 Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. |
| 36 | 90.10.3.15Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 37 | 90.15.4.1 Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 38 | 90.15.4.4 Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 39 | 90.15.4.7 Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V\"AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 40 | 90.6.10.1 Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm |
| 41 | 90.6.10.2 Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required 25 mm |
| 42 | 1.17.12 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 43 | 1.17.3 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 44 | 1.17.1 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm |
| 45 | 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 46 | OD240648/2025-2026 Supply and Installation of 12W LED Bulb of reputed brand |
| 47 | 1.24.2 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 amps switch |
| 48 | 5.5 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt) as required. |
| 49 | OD240693/2025-2026Charges towards taking KSEB connection |
| 50 | CCTV SURVEILLANCE AND AUDIO SYSTEM |
| 51 | 14.13.1 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia |
| 52 | OD240840/2025-2026 Supply, Installation, Testing and Commissioning of HIKVISION HD Camera 5MP,ColorVu Mic-3K Bullet, DS-2CE10KFOT-PFS |
| 53 | OD240847/2025-2026 Supply, Installation, Testing and Commissioning of HIKVISION HD Camera 5MP ColorVu DOME, DS-2CE70KF0T-PFS |
| 54 | OD240963/2025-2026 Supply, Installation, Testing and Commissioning of HIKVISION DVR 32CH 4MP IDS-7232HQHI-M2/S (M2/XT) including all accessories as required |
| 55 | OD240965/2025-2026 Supply, Installation, Testing and commissioning of ERD SMPS 16CH AD-33 |
| 56 | OD240978/2025-2026 Supply and Installation of HDMI Cable, 5 Metre long of reputed brand |
| 57 | OD240979/2025-2026 Supply and Installation of HDMI Splitter of reputed brand |
| 58 | OD240991/2025-2026 Supply and Installation of 4U Rack, Powder coated, including all necessary accessories etc. as required |
| 59 | OD241003/2025-2026 Supply and Laying of Coaxial camera through existing recessed PVC conduits and connecting it to camera by crimping with necessary connectors etc. as required Make: Finolex/Equivalent |
| 60 | OD241109/2025-2026 Supply and Installation of Hard Disc, Western Digital Purple 4TB Surveillance Hard Drive SAТА |
| 61 | OD241227/2025-2026 Supply and Installation of Camera back box, BNC Connector and DC Pin etc. as required |
| 62 | OD241294/2025-2026Supply, Installation, Testing and Commissioning of Samsung 138 cm (55 inch) Ultra HD (4K) LED Smart Tizen TV (UA55DU7000KLXL) with all necessary fittings etc. as required |
| 63 | OD241417/2025-2026Supply, Installation, Testing and Commissioning of 30W Wall speaker (Black) Studio Master (ARC32) |
| 64 | OD241457/2025-2026 Supply, Installation, Testing and Commissioning of 60W Wall speaker (Black) Studio Master (ARC60) |
| 65 | OD241420/2025-2026 Supply, Installation, Testing and Commissioning of AMPLIFIER- AHUJA(SSA5000EM) with all necessary accessories as required |
| 66 | OD241429/2025-2026 Supply and Installation of GOOSENECK MICA-JTS(GM5218) |
| 67 | OD241432/2025-2026 Supply and Installation of GOOSENECK BASE-JTS(ST5030) |
| 68 | OD241433/2025-2026 Supply and Installation of MIXER 7 CHANNEL - NX AUDIO (FMU7B) |
| 69 | OD241456/2025-2026 Supply of MIXER LEAD(10M)-MSA(HEAVY) |
| 70 | OD241434/2025-2026 Supply and Installation of JACK-JACK CABLE(1,5M)-MSA |
| 71 | OD241455/2025-2026Supply and laying of 2 core 1 Sq.mm speaker wire, oxygen free copper suitable for wiring speakers in existing PVC conduits and giving connections as required |
| 72 | OD241459/2025-2026 Supply and installation of Desktop computer with the following specifications 1.Intel core i5 12400 Generation processor 2.Intel H610 Motherboard,16 GB 3200 MHZ Ram 3.1TB NVME SSD Hard disk 4.4GB NVDIA 730 Graphics card cabinet with SMPS ANTEC,5. 24\" Full HD IPS Monitor, keyboard & Mouse, Wireless adaptor, win 11 (3 years spare warranty), 1KVA offline UPS with inbuilt battery (2 years warranty) Please Enable Macros to View BoQ information |