| 1 | Dismantling plain or corrugated steel sheeting , any guage , thickness incl nanital pattern as in roof covering complete all as specified and directed. |
| 2 | Dismantling Timber scantlings 40 Sqm cm over in section in any position framed work complete all as specified and directed. |
| 3 | Demolation of brick work/ solid concrete block work built in Cement mortar complete all as specified and directed. |
| 4 | Demolation of cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed. |
| 5 | M&L for wrought second class hard wood in scantlings framed and fixed complete all as specified and directed. |
| 6 | Fixing only for wrought second class hard wood in scantlings framed and fixed complete all as specified and directed. |
| 7 | M&L for preparation of wood and wood based material , new or old of any description and girth not otherwise described and treated with creosote oil complete all as specified and directed. |
| 8 | S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 9 | S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick as in roof covering including fixing with self driving machine made screw with washers and fitting of same manufacture of approved profile , shape and colour complete all as specified and directed. |
| 10 | Taking down chowkhat with shutter (without taking off shutter from the frame) and area exc 1.5 sqm but n.exc 4 sqm each complete all as specified and directed. |
| 11 | Taking down chowkhat with shutter (without taking off shutter from the frame) and area n exc 1.5 sqm each complete all as specified and directed. |
| 12 | M&L 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid ,rounded or chamfered ,put together with glue pinned at joints complete all as specified and directed. |
| 13 | S&F 35 mm thick Flush door shutters solid core construction with block board core and ply wood face pannels commercial veneered on both faces complete all as specified and directed. |
| 14 | S&F 35mm thick 2nd class hard wood skelton shutters open rebated and prepare to receive glass, gauze, etc devided into squares with plain chamfered or rounded, mitred and rebatedsash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(a) complete all as specified and directed. |
| 15 | M&L for Machine cut Kota stone slab flooring 18-20 mm thick over and incl 20 mm thick cement screed bed in CM 1 : 6, laid and jointed with greay cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 16 | M&L for machine cut kota stone floor 18-20 mm thick over & including 10 mm thick screed bed in cm1:4 as in skirting , set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 17 | M&L for 25 mm thick Cement concrete 1:2:4 type B-1,(20mm graded aggregate complete all as specified and directed. |
| 18 | S&F for stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 19 | M&L for 5.5 mm thick sheet glass quality and glazing fixed to aluminium frame exc 0.50 sqm complete all as specified and directed. |
| 20 | S&F, 150 mmaluminium handles cast type, anodised complete all as specified and directed. |
| 21 | S&F Butt hinges of 100mm size, extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed complete all as specified and directed. |
| 22 | S&F aluminium anodised barrel bolts and fixed of 150 mm length complete all as specified and directed. |
| 23 | S&F 300mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 24 | M&L for preparation of new or previously untreated surfaces of wood and wood based materials of any description not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 25 | S&F for floor door stopper withalluminium alloybody anf tongue,with hard drawn steel spring 140mm long complete all as specified and directed. |
| 26 | M&L forpreparation of new steel surfaces of any description ,over 10 cm in width or girth,not otherwise described and applyingtwo coat of synthetic enamel paint over a coat red oxide primer complete all as specified and directed. |
| 27 | M&L for rendering15m thick on fair faces of brick or concrete work in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 28 | M&L for 10 mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and directed. |
| 29 | M&L for PCC 1:3:6 type C-2 (using 20 mm graded stone aggr ), 75 mm thick as in plinth protection finished even and smooth without using extra cement layed in bays not exc.2.00 complete all as specified and directed. |
| 30 | M/L precast cement concrete block masonry with solid blocks exc 10 cm in width and settings in CM 1:6 type C1 1:3:6 (20mm graded aggregate) complete all as specified and directed. |
| 31 | M&L for preparation of old wall surfaceand applying two finishing coat of oil bound distempering over 1mm of wall care putty complete all as specified and directed. |
| 32 | M& L for applying Two or more coats (over 1 mm thickwall care putty ) of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on old or previously untreated surface complete all as specified by Engr-in-charge. |
| 33 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. |
| 34 | S&FExpanded metal, cut to length,bent to shape required andtying with and including Welded steel wire fabric supplied notlessthan 0.9mm dia and weight n less 4kg per sqm or fixingwith galvanised steel staplessupplied and fixed completeto wood or steel members complete all as specified and directed. |
| 35 | M & L for PCC 1:3:6 type C2 (40 mm graded aggregate) as in surface channels and drains complete all as specified and directed. |
| 36 | M & L for 40 mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floors finished, surface even and smooth without using extra cement, complete all as specified and directed. |
| 37 | M&L Hardcore usingbroken stone /boulders of gauge n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 38 | S&F 2nd class SW boarding 20mm thick fixed with nails in eaves board plained one side with butt joint complete all as specified and directed. |
| 39 | M&L 75mm PCC(1:4:8) type D2 using 40mm graded stone aggregate as in sub base of floor and filling as mass conc complete all as specified and directed. |
| 40 | M&L for 3mm thick tarfelt placed/sealed in joints of CGI/PGI sheets complete all as specified and directed. |
| 41 | Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed. |
| 42 | Excavation in post holes each n.exc. 0.5 cum in soft/loose soil getting out returning, filling in and ramming earth or broken rubble mixed with earth around in layer n.exc. 25 cm, watering and removing surplus soil to a distance n.exc. 50 mtr and making good surface complete all as specified and directed. |
| 43 | M&L 100mmthick cement concreteusing (40mm graded aggregate) type D-2 (1:4:8)as in sub base complete all as specified and directed. |
| 44 | M&L forPCC (1:2:4), type B1 (using 20 mm graded stone aggregate) as in foundation filling and mass concrete including all necessary form work complete all as specified and directed. |
| 45 | M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in copingcomplete all as specified and directed. |
| 46 | S&F Gl frame work for snapgrid false ceiling comprising of Gl perimeter channnel 0.55 mm thick with Main T- flange of 25 mm and web of 30 mm fixed to surrounding wall angle with flange and web 25 mm each , Cross T with flange 25 mm and web 25 mm fixed to mainT, Main T is suspended from soffit @ 1200 mmm c/c using GI wire of 4mm thickness GI frame will be 60 x 60 cm to recieve E-board ceiling complete all as specified and as directed . |
| 47 | M&L 4mm thick E Board 600x600 mmprepainted fibre boards ceiling designer/decorative type with different designs as approved, fixed or laid in ceiling timber /GI/ aluminiumframe work in ceiling flat or sloping complete all as per manufacturer instruction complete all as specified and as directed. |
| 48 | S&F steel work as in tubular , rafters, purlins, posts and similar work(round/square/rectangular shape of pipes as approved by Engr-in-charge ) trusses including posts, special shaped washers, gusset plates etc complete using ERW or induction butt welded tubes conformining to IS 1161-1998 garde St-240 complete all as specified and directed. |
| 49 | S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay,complete with glazing bars, dovetailed or welded complete all as specified and directed. |
| 50 | M&L for 4.80 mm thick sheet glass quality and glazing fixed to aluminium/ steel frame n.exc 0.50 sqm complete all as specified and as directed. |
| 51 | S&F Butt hinges 125mm, mediumweight, stainless steel, and fixed complete all as specified and directed. |
| 52 | S&F Mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete150 mm longcomplete all as specified and directed. |
| 53 | S&F Mild steel pressed handles, oval type, stove enamelled blackof size 150 mm complete all as specified and directed. |
| 54 | M&L for MS Plates (plain or chequered) channels, angle , square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410 -W (Gde-E- 250) quality- A Fe complete all as specified and directed. |
| 55 | S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 andfitting of same manufacture of approved profile, shape and colour complete all as specified and directed. |
| 56 | M&L plain cement concrete Type C2 1:3: 6 (40mm graded aggregates) in foundations, filling in post of fencing, pcc sub-baseand mass concrete complete all as specified and directed. |
| 57 | M&L MS roof trusses (framed), trussed, purlins, crane gantries, rails, posts and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde-E- 250) quality- \"A\"complete all as specified and directed. |
| 58 | M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade use grey cement and pigment complete all as specified and directed. |
| 59 | M&L sand filling under floors/paver blocks or cushioning/bedding including watering and consolidation complete all as specified and directed. |
| 60 | Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified. |
| 61 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked,including 20 mm dia concealed on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitablesteel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existingfor one light/fan point controlled by one switch. |
| 62 | Description all as per Srl item No. 61here in before but for socket outletpoint 5 Amp on Independent board. |
| 63 | Description all as per Srl item No. 61 here in before but for socket outlet point 5 Amp on same board. |
| 64 | Description all as per serial item No 61 above but with 4 sqmm cablefor 3 pin 15 Amps switch socket outlet (Power point) complete all as specified. |
| 65 | Supply and fix switch socket combination5 in 1 , 6 pin , (5/16 Amps ) flush typecontrolled by one switch complete all as specified. |
| 66 | Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified. |
| 67 | Supply and fix switch socket combination5 in 1 , 6 pin , (5/16 Amps ) flush typecontrolled by one switch complete all as specified. |
| 68 | Supply and fixing LED batten fittings 1x 20 Watt complete including LED light driver, holder, LED lamp and connection up to ceiling rose with three core wire fixed to wallwith 2 nos PVC block of suitable size including taking down old unserviceable one . |
| 69 | Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. |
| 70 | Supply and fixing in repair,LED Bldg Security Light Fittings of capacity 25 watt made up of die castaluminiumhousing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver and making electrical connection, service bracket of mild steel pipe 25 mm bore medium grade of length 0.70 mtr fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts and washer and suitable reducer for connecting fitting to GI pipe as required at site includingtwo coats ofsynthetic enamel paintoverone coat of red oxide primer on mild steel work completecomplete all as specified and as directed. |
| 71 | Supply and fix in repairs MCB Distribution board , 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. |
| 72 | Supply and fix MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity \"C\" seriescomplete all as specified and directed |
| 73 | Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB\"s.complete all as specified and directed |
| 74 | M & L Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia concealed on wall/ceiling inISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduitshall be measured as one RM. |
| 75 | SITC of Hot Air Blower, consisting of 15 KW /415 V heater, powered by 1.5HP Motor 415V along with SSR Based Control Panel producing 800 CFM of air at Ambient with 6 Nos of 10 Sqmm Copper Wire from Main Line to Panel Board and from Panel Board to Motor upto 60 mtrs Maximum Distance. complete all as specified and as directed (Make : As Approved by GE). |
| 76 | Supply & Fixing of Sensor for auto cut off to avoid High Temperature in the Drying Room complete all as specified and as directed. |
| 77 | Supply & Fixing of Digital Display Thermometer with sensors fitted inside the room and display screen at the outside for display of information complete all as specified and as directed. |
| 78 | Supply & Fixing Maintenance Free Chemical Earthing of Minimum Ht of 2 Mtrs, 50mm Dia or More for the Electrode with Earthing Enhancing Bagfill Compound, Copper Bonded. complete all as specified and as directed. |
| 79 | Supply and fixing modular switch 1 way 6A module 230/250 volt , AC supply,ISI Marked, with cover plate complete all as specified and directed. |
| 80 | Supply and fixing modular sockets 6A 2/3 pin combined 2 module, with frame and cover complete230/250 Volts,50 Hz , AC supply, ISI Marked, with cover platecomplete all as specified and directed. |
| 81 | Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 modulewith frame and cover complete 230/250 Volts,50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 82 | Supply and fixing modular switch 16A1 module with frame and cover complete 230/250 Volts,50 Hz , AC supply, ISI Marked, c with cover plate omplete all as specified and directed. |
| 83 | Supply and fixing LED security Buildinglight LED 36 Watt, pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of lightcomplete. |
| 84 | S&F in repair GI Bracket of dia 40 mm light grade with 1.2 mtr length including fixing the fitting removed for changing the bracket and connection with existing wire etc all as directed. |
| 85 | M&L in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as directed by Engr-in-Charge. |
| 86 | Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I. |