Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-02-2026 | Corrigendum NO 01 | BOQ | 11-02-2026 |
| Sl. No. | Item Description |
| 1 | Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed. |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed. |
| 3 | Demolition of cement concrete (Reinforced) of any description and in any position such as RCC water tank 500/1000 ltr capacity, cover slab, kitchen plateform, etc not otherwise specifically provided for complete all as specified & directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), rubbish off the debris out of MOD premises complete all as specified and directed |
| 5 | Taking down cement plaster/wall tiles including backing etc from brick/stone walls / concrete surfaces including raking out joints,hacking for key , scrubbing down with water etc complete all as specified and directed |
| 6 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified & directed. |
| 7 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified & directed. |
| 8 | Taking down shutters of any description exc. 1 sqm and not exc. 2 Sqm each, complete all as specified & directed. |
| 9 | Taking down, easing and adjusting shutters of any description, exceeding. 1.00 Sqm and not exceeding 2.00 Sqm each and re-fixing in the sameor other opening completa all as specified and directed. |
| 10 | M&L for Brickwork with Fly Ash Bricks (old size), straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified. |
| 11 | M&L for Brickwork with Fly Ash Bricks (old size), straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 but except bricks complete all as specified. |
| 12 | M & L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:6 complete all as specified and directed |
| 13 | M &L Providing precast cement concrete louvres and jallies Set in CM 1:4 Type B0 1:2:4 (using 12.50 mm graded crushed stone aggregate) , 50mm thick (measured solid), including all mouldings but excluding frame (Note: Precast frame shall be measured separately) |
| 14 | S&FFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 50 X 100 MM comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 15 | S&FFactory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 50 X 125 MM comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugsor SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 16 | S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ choowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with fullbody threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs fasteners shall be paid for separately) complete all as specified & directed. |
| 17 | S & Ffactory made single extruded WPC (Wood Polymer Composite) solid one side decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutterand fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately). |
| 18 | S & FFactory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm thick size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: Stainless steel butt hinges and necessary S S screws shall be paid separately. |
| 19 | S&F of 35mm thick single piece Factory made wire gauge doorshutters including of wire cloth (steel & aluminium XPM) manufacturing by PVC sheets printed 5mm thick on both side on frame made out of M.S tube 19 SWG, size 19mm x19 mm complete in all respect with lock rail and beautified by PVC beading all around fixed with PVC solvent cement complete all as per Drawing No CEPZ/TD-378/, Sheet 1/1 dated 27/12/2011 complete all as specified and as directed by Engr-in-Charge. |
| 20 | S&F for 35mm thick 2ndclass hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified & directed. |
| 21 | Supply and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame 88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm 18mm), sliding mesh sash (26mm x 10mm) profile be inserted in required profile, frame will be fixed the wall with 8mm x 100mm long fasteners, Hardware Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Area Not exceeding 2.00 Sqm Area Each complete all as specified and directed. |
| 22 | S&F for Box type steel windows comprised of tubular frame and shutters made out of 1.25 mm thickMS sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes will be measured and paid seperately) with side hung shutters with MS handles and MS peg stay dovetailed or welded incl 02 Nos, MS Tower bolts 150 mm long for each leaf and 8 mm square bar grill / guard bars at spacing as shown on Drg welded to MS flat iron frame work ,including other fittings ,hinges ,MS handles ,tarred hold fasts ,PCC blocks for hold fastsetc all as shown on Drg No CEPZ/TD -354/09 sheet 1/3 to 3/3 including two coat of synthetic enamel paint over one coat of red oxide zinc primer, complete all as specified and directed by Engr-in-charge. |
| 23 | S&F for Butt hinges 100 mm long, stainless steel, medium weight with SS hinges pin and fixed complete all as specified. |
| 24 | S&F for Aluminium alloy, anodised, sliding door bolt 300 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or castaluminium alloy and fixed . complete all as specified and directed. |
| 25 | S&F for Aluminium, anodised, barrel tower bolts 150 mm of extruded section and fixed. complete all as specified and directed. |
| 26 | S&F for Aluminium, anodised, handles 125 mm of extruded section and fixed.complete all as specified and directed. |
| 27 | S&F rubber lining fitted with aluminium powder coated strip, 100mm wide for door cill complete all as specified and directed. |
| 28 | S&F for floor door stopper of 140mm long cover plate of aluminium alloy body and tongue anodised with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 29 | S&F for Mild steel, 300mm, ordinary rat tail rod patttern springs includding roller and roller plate complete fixed with screw or necessary welding to pressed steel door frame complete all as specified and directed. |
| 30 | S&Fstainless steel peg set of six of size 400mmx30mmx3mm size fitted with machine screw and wooden and plastic cleats (minium wt 190gms) complete all as specified and directed. |
| 31 | S&F stainlesssteel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed in repair with statinless steel wire staples complete all as specified and directed. |
| 32 | S&F for Stainlesssteel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with statinless steel wire staples complete all as specified and directed. |
| 33 | S&F, 4 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc. 0.5 sqmin each pane, complete all as specified and directed. |
| 34 | S&F \"as in repair\" 25mm outer dia stainless steel decorative drapery rod of thickness 20 guagewith stainless steel brackets near to ends with stainless steel finialswith adopter for 25 mm dia drapery rod at both ends complete all as specified and directed. |
| 35 | Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 36 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing ,etc., and making good, cutting not exc 10 cm girth in brick walls, complete all as specified. |
| 37 | Supply & Fixed steel water tubing 15 mm bore medium grade galvanised with all fittings (ISI marked) fixed complete to walls, ceiling and floor. complete all as specified. |
| 38 | Taking up or down steel tubing of 20mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store with all fittings, complete all as specified and directed. |
| 39 | Supply & Fixed steel water tubing 20 mm bore medium grade galvanised with all fittings (ISI marked) fixed complete to walls, ceiling or laid in floors complete all as specified. |
| 40 | Refixing old steel tubing 20 mm bore and connections in new or old position (walls, ceiling, floor etc.) complete all as specified and directed. |
| 41 | S&F for GIpipe 32 mm dia light grade in short length as spout pipe in sunken floor slab laid in slope to brick wall with PCC 1: 2:4 TYPE B -1 (using 20mm graded crushed stone aggregates) complete all as specified and directed. |
| 42 | S & F Rotational moulded polyethlene water storage tanks three layers of 500 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including dismantling of old existing broken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed. |
| 43 | S & F Rotational moulded polyethlene water storage tanks three layers of 1000 ltrs capacity ISI marked (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I including 25mm thick Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms including dismantling of old existing broken water tanks and refixing of inlet, outlet & over flow pipe etc complete all as specified and as directed. |
| 44 | S&F in repair 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed. |
| 45 | S&F Concealed Stop valve (ISI Marked), cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore and fixed complete all as specified and directed. |
| 46 | S&F Bib tap 15 mm bore long body, Brass CP, fancy type (long shank )., with crutch or butterfly handle screwed down screwed for iron/PVC pipe or for brass ferrule and fixed, complete all as specified. |
| 47 | S&F Stop valve /Angle valve (ISI Marked), fancy type, chromium plated with long shank and cupscrewed down, high pressure with crutch or butterfly handle, screwed both ends for iron /PVC pipe or for unions of 15 mm bore andcomplete all as specified. |
| 48 | Supply & fixed CP Brass shower rose 200x200 mm size with with flexible brass arm 450-550mm long for 5 mm bore pipe complete all as specified and directed. |
| 49 | Supply and fixed Soap dish cantabile-clea (material SS finish, glossy) fixed to plugs with CP brass screws complete all as specified and directed. |
| 50 | Supply & fixed in repair, Vitreous china squatting pan of pattern, long pan, \"Orissa pattern\", size 580 x 440 mm white with integral foot rests (excl flushing cistern and flush pipe) but including provision concrete bedding CI floor trap etc complete all as specified and directed. |
| 51 | Supply & fixed , Vitreous china wash down water closet pan (Pedestal pattern) white (excl fixing bolts, flushing cistern and flush pipe) but including plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel CP or aluminised hinging device complete all as specified and directed. |
| 52 | S&F in repair plastic water closet seat cover, back closed pattern with flat bottom,and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 53 | S&F CP Brass Hand Shower (Health Faucet) with 8 mm dia,1.2 m longLongFlexible Tube Chrome Finish & Wall Hook for Water closet complete all as specified and directed. |
| 54 | Supply & fixed in repair 5.50mm thick bevelled edge mirror of selected quality glass, mounted on 6 mmdia SS clamp on counter complete all as specified. |
| 55 | S&F Centre hole basin mixer without popup waste system with 450mm long braided hoses cast copper alloyfor iron pipes 15 mm bore, screwed for iron pipe and fixed and all as specified and directed. |
| 56 | Supply & fixed in repair Push botton type dual flush type PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and push botton (incl brackets & flush pipe PVC 32 mm dia) capacity of 10 Litres complete all as specified and directed. |
| 57 | Supplied and fixing sink with drainage board made of stainless steel 1 mm thick with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets of angle iron and connecting union to pipe over all size 915 mm x460 mmand bowl size 400mmx300mmx 180mm complete all as specified and directed. |
| 58 | Supply & fixed in repair, Vitreous china wash basin, white flat back, size 550 x 400 mm excl taps, wastechain and plug and porcelain stopper but incl brackets.Complete all as specified and directed. |
| 59 | Supply & fixed ,Vitreous China Urinal, Half stall type, white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe, grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) fixed incl supply and fixing ofCP coupling, waste pipe and cp brass spreder all necessary fittings, complete all as specified and directed. |
| 60 | S & F corrugated waste pipe, 32 mm dia, suitable for WHBs/sinks/Urinal, including threaded PVC socket suitable for shank of waste coupling complete all as specified. |
| 61 | S&F Brass CP towel rail 20mm dia \"D\" type 60 cm long between flanges complete all as specified and directed. |
| 62 | S&F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 63 | M&L PVC (SWR) floor trap, dia of outlet in 75 mm, plain excludinggrating, but including jointing with solvent cement fixed in repair complete all as specified and directed. |
| 64 | Supply & fixed PVC grating square, 150 mm (Hinge pattern and with or without hole) complete all as specified and directed. |
| 65 | Supply & fixed in repair, 110 mmbore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls / trench with suitable clamp complete all as specified and directed. |
| 66 | Supply & fixed, 110 mm bore PVC (SWR) bends any radius, with or without excess door complete all as specified and directed. |
| 67 | Supply & fixed, 75 mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 68 | Supply & fixed in repair, 75 mmbore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls /trench with suitable clamp complete all as specified and directed. |
| 69 | Supply & fixed, 75 mm bore PVC (SWR) bends any radius, with or without excess door complete all as specified and directed. |
| 70 | S&F Non skid ceramic jointless coloured tiles,7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floor etcset & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified and directed . |
| 71 | S&F Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed. |
| 72 | M&L for 25 mm thick (average thickness) PCC 1:2:4, type B-0 using 12.5mm graded stone aggregates as in floor by maintaing required gradient/undulation, finished even and smooth w/o using extra cement complete all as specified and directed |
| 73 | M&L for Granite (of any type) work (table rubbed & polished) in steps, jambs, pillars, window-cills cooking platforms & likeincluding pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite laid over and including Screed bed or bedding layer of mortar 15mm thick for laying floor in CM 1:4 finished even & rough to receive top layer including rounding/bull nose to expose edge , complete all as specified and directed. |
| 74 | M&L for Machine cut Kota stone slab flooring not less than 18-20mm thick (size of stone shall not less than 55cmx55cm), 75mm wide white marble border alround, laid over & including 20 mm thick screed base in CM 1:6, jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine,complete all as specified. |
| 75 | M&L for Machine cut Kota stone slab not less than 16mm thick as in riser of steps, skirting, dado and pillar laid over& including 10 mm thick screed base in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, grinding and polishing to yield mirror finish with machine, complete all as specified. |
| 76 | M&L for parking tile heavy duty coloured Endura tile dotted, non skidof size 300mmx300mmx10mm, top layer glazed made in any type of cement and pigment, in required patterns in floor etc set & jointed in neat cement slurry & pointed in white or coloured cement mixed with pigment to match the shade of tile over and including 15mm thick screed bed or bedding layers in CM 1:6 for layingfloor finishes, complete all as specified and directed. |
| 77 | M&L for coloured machine pressed precast rubber moulded concrete interlocking red/yellow) paver block of any shape and size with 6-8mm white cement layer mixed with pigment and coated with epoxy coating having high glossy finish confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid dry over and including 50mm thick sand filling under paver, properly levelled etc, including taking out existing interlocking paver block complete all as specified and directed. |
| 78 | M&L for concrete interlocking paver block any shape and size, Excepttiles & refixing the same, complete all as specified and directed. |
| 79 | M & L forChequered cement concrete tile 20cmx20cmx25mm thick ,set and jointed over 20 mm screed bed in CM 1:4 and pointed in neat cement slurry in floor with grey pigment cement and pigment complete all as specified and directed. |
| 80 | M&L for 75 mm thick cement concrete type C-2, 1:3:6 (using 40mm graded crushed stone aggregates) as in Sub-base to floor finishes complete all as specified and directed. |
| 81 | Rendering 05 mm thick plaster in cement mortar 1: 3 on concrete surfaces as in ceilingsfinished even and smooth (without using extra cemen) complete all as specified. |
| 82 | Rendering 10 mm thick on other than fair face of brick work or concrete surface in CM 1:6,finished even and smooth (without using extra cement) complete all as specified and directed. |
| 83 | M&L for 12 mm thick rendering inon Fair faces brick work and concrete surfaces of wall in CM ,1:4 finished the surface even and smooth without using extra cement, mixing and including WPC @ 200ml/bag of cement, complete all as specified and directed. |
| 84 | Taking down cement plaster and decayed concrete of any description, upto tripple storey of building, from roof projection, chajja etc and making good the decayed portion with cement mortar1 :3 mixed with water proofing compound as per manufacturers instruction or PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) including necessary form work and finally finished the surface with 15mm thick cement plaster in CM 1:3, complete all as specified and directed. |
| 85 | M&L for 75 mm thick cement concrete 1:3:6, type C1 (using 20mm graded agg) as in plinth protection finished even and smoothusing extra cement.(incl necessary joint filling with mixture of paving bitumen & sand in 1:3) complete all as specified and directed. |
| 86 | Preparation of newly plastered surface of wall and applying two coats of oil bound distemper, white or tinted shade with and including priming surface with 1mm thick wall care putty on walls, complete all as specified. |
| 87 | Complete removal of existing treatment of wall surfaces and applying two coats of oil bound distemper, white or tinted shade with and includingpriming surface with 1mm thick wall care putty on walls, complete all as specified. |
| 88 | M&L for preparation of newly plastered external surfaces of walls applying two coats of cement based paint, white or tinted including curing before and after paint complete all as specified and directed. |
| 89 | M&L for preparation of old surfaces of walls of any description including washing down, rubbing, brooming down with wire brush, scrapping down smoke, roots, moulds, salts and treading oil and greasy spots, including taking down existing grass, vegetation, small trees and making good the disturbed surface with cement mortar 1:3 and applying one coat of cement based paint, white or tinted including curing before & after paint complete all as specified and directed. |
| 90 | M&L for preparing newly plastered surfaces and applying three coats of white wash as in ceiling etc complete all as specified and directed. |
| 91 | M&L for preparing of Old painted surfaces of steel or iron surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 92 | M&L for preparing of new or previously untreated surfaces of wood of any description not otherwise describedover 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 93 | M&L for preparing of Old painted surfaces of wood of any description not otherwise describedover 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 94 | M& L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, bed plates benching,floor by maintaing required gradient/undulation etc slightly rounded or chamferred angles and throating, complte all as specified and directed. |
| 95 | Taking down existing Aluminium door/window and refixing to the same opening after repairing, easing and adjusting incl replacement of damaged hinges, brass mortice lock, sheet glass, door closer, Elco Panel , floor spring, rubber neoprene packing, aluminium beading, glazing clips and SS screws complete all as specified and directed.( Mortice lock, sheet glass, hydraulic door closer, floor spring and composit panel to be measured and paid seperately under supply only. |
| 96 | S&F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. having minimum thickness of powder coating 50 micronincl taking down complete all as specified and directed. |
| 97 | S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc.incl powder coating of any colour not less than 50 micron thickness complete all as specified and directed. |
| 98 | S&F powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) incl Powder Coatingof minimum thickness of powder coating not less than 50 microncomplete all as specified and directed. |
| 99 | Supply only Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 1 universal type, suitable for door shutters up to 700 mm in width and of weight not more than 35 kg and fixed all as specified and directed. |
| 100 | Supply only Sheet glass 4.8mm thick ,ordinary quality fixed with aluminium beading and rubber gaskeet exc 0.50 sqm each. all as specified and directed. |
| 101 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spribng clips and providing and fixing new ones exc 1.5 Sqm complete all as specified and directed. |
| 102 | Supply onlyfor Aluminium 4 Lever Mortice lock, vertical type of size 100mm complete all as specified and directed. |
| 103 | Supply only for Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty all as specified and directed. |
| 104 | S & Ffor 4mm thick Aluminium composite panel for fixing to Aluminium shutter and the like squares with aluminium beading/gasketc complete all as specified and directed. |
| 105 | M&L Reinforced cement concrete (nominal mix) in Type - B0 1:2:4 (using 12.5mm graded crushed stone aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 106 | M & L for Precast reinforced cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate as in manhole cover slab and finishing the surface and necessary formwork complete all as specified directed by engr in charge. |
| 107 | M&L TMT steel bars 6 to 8mm dia, cut to length bent to shape required including cranking bending etc and binding with and including mild steel wire (annealed) not less than 0.9mm dia.complete all as specified directed by engr in charge. |
| 108 | Use and waste of formwork to soffits of WHB counter, plateform rough finished surfaces of suspended slabs such as roof slab,floor slabs landings and similar workscomplete all as specified and directed. |
| 109 | M&L 15 mm thick plaster in CM 1:4 with intergral water proofing compound and applying 75 mm thick padding and junction coved filling of PCC M-20 Nominal Mix (1:1.5:3) of (using 12.50mm graded crushed stone aggregates) on the junction offloor and wall the surface shall than he cured and allowed to dry Apply Epoxy Resins Coating, polymer Modified Cementation coating like brush bond of frsroc, pedilite and bostic as per manufactures instruction both on floor as well as on wall complete all as specified and directed by Engr in Charge. |
| 110 | Supply only liquid water proofing compound complete all as specified and directed. |
| 111 | M&L for Cement concrete 1:5:10 type D-2 (using 40mm graded crushed stone aggregate)as in mass filling in sunken slab of toilets, complete all as specified. |
| 112 | Cleaning/clearing of sewage line (including manholes) 100mm to 150mm bore of any description, underground at any depth ,removing any type of blockage including desilting, descaling & dechockingof drains as well as manholes and depositing the sludge in a pit (including digging of pit) not less than 100 metres away from the site of cleaning and covering the sludge with layer of 2.5cm thick layer of earth and spraying unslacked lime on the pit and make line smooth functional all as specified and directed. |
| 113 | S & F of Wire netting of stainless steel wire 0.71 mm dia wit size of mesh 25mm fixed with tinned tacks of stainless steel wire staples complete all as specified and directed. |
| 114 | M&L cement concrete 1:1.5:3 type B-0 (using 12.50 mm graded stone aggregate) leveling course on existingroof, rounded and chamfered on edges, with Wpc @200ml/ bag of cement complete all as spd and directed.Note:- WPC shall me measured and paid separately. |
| 115 | M&L for 20 mm thick plastering onconcrete surfaces of roofin CM ,1:4 finished the surface even and smooth without using extra cement, mixing and including WPC @ 200ml/bag of cement, complete all as specified and directed. Note:- WPC shall me measured and paid separately. |
| 116 | Material and labour forStrengthening and repair to RCC structural members such as column, beams, fins, Facia, chajjas & RCC slab as per the following precedence of applicationincluding necessary formworks and scaffolding if required upto 7 m height including dismantling loose/cracked plaster/concrete portion from RCC surface in any thickness complete all as specified and directed. (a) Taking down the damaged/ loose concrete over existing structure and then making holes to existing structure to recieve slurry .Injecting and grouting to arrest leakage by using polymer based liquid water proofing compound mixed with cement @ 400 mili litre per bag of cement in the water to form slurry. pumping the slurry through these holes one by one by using pressure pump till bleading the slurry and leave the surface for 24 hrs.(b) Applying one coat of steel bar coat of rust preventive PH RB-167/rust free/SHIELDOXY including preparing, cleaning of corroded steel all as per manufacturers instructions complete including providing additional reinforcement properly binded, overlap with the existing reinforcement and maintaining sufficient developement length/Anchorage length at the junctions to be inserted in the bearings of the R.C.C slab /RCC beam/RCC member to ensure/ acknowledge proper bond with the surrounding concrete complete all as specified and as directed by the Engr-in-Charge.(c) Providing/ filing the plain cement concrete 1:1.5:3 type A-0 (using 12.5 mm graded crushed stone aggregate) upto the depth/thickness varrying from 15mm to 45 mm.(d) Applying two coats of exterior emulsion paint over a coat of primer complete all asspecified and directed.Note:- The additional reinforcement, if any required on the siteshall be measured and paid separately under respective item of the BOQ. |
| 117 | M & L forAccessible , Sloped & Exposed Terrace, Deck Slab as under:-(a) Removal of Existing PCC/Brick Bat Coba/Mud phuska/ APP membrane from the roof stacking the reusable material and disposal of unserviceable ribbish out site the campus as per direction of the client with in 3 Km.(b) Cleaning of surface of loose dust and dirt cement slury etc. by means of wire brush, dust removing brush and scraper etc.In case of Pot Holes/ Cracks same shall be repaired with cement with cement admixed with Polymer as per manufacturer instructions etc.(c) Gola on Mother Slab: Providing and Making of PCC coving (gola) of size 75mm X 75mm with concrete Mix (1:2:40, cement sand, grit and including cost of mixing water proofing compund of approved make etc. complete as per direction by Engineer in Charge.(d) The surface shall be primer with Smart care epoxy primer to seal the pores and enhance the adhesion of the coating. Supplying and applying single component water proofing liquid membrane based on pure elastomeric, polyutherine resin smart care pu magnum us, cold applied of spray/ brush applied, membrane with elogation > 600% and tensile strength of 3-4 Mpa as per Astm D 412. crack bridging ability of 3mm as per ASTM C1305, no leakage upto 5 bars of water pressure as per DIN 1048, shore A Hardness > 50 Shore as per ASTM D 2240. The minimum thickness to be applied shall be 1.5mm.(e) Providing & laying of protective Geotextile fabric 150GSM over the entire membrane with proper overlaps of 75mm before of Brick bat coba treatment.(f) M & L for Non skid ceramic jointless coloured tiles,7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floor etcset & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 20mm thick screed layer in cement mortar 1:6, complete all as specified and directed . |
| 118 | Supply and applying fortwo component elastomeric acrylic polymer modified cementitious waterproofing coating over brick wall surface , Smartcare Ultra Block 2K or approved Equivalent Having>220% elongation as per ASTMD 2370, Resisting 5 Bars Hydostatic pressure as pepr DiN 1048, Reduction to rapid chloride shall be 70 as per DIN 1048, Craki bringing upto 3.50mm as per EN 1062. The coating shall have food grade certificate from laboratories like CFTRI. The Mixing ratio of Coating shall be 2 PArts of Powder & 1 Part of Liquid without any water addition in mixing etc. complete as per manufacturers specification. Minimum consumption shall be 2 kg/Sqm. Supply and applying bond application MIX AP SC repair polymer and cement in RAtio of 1: Brush apply 1 or 2 continuous coat of Mix and ensure minimum consumption shall be 0.2 Kg/Sqm complete all as specified and directed. |
| 119 | M& Lpreperation of inaccessible roofsurfaceby scrapping and properly cleaning the existing roof treatment in any number of layers upto original RCC roof top surface. (i) Apply first coat Fiber reinforced Elastomeric liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibres with sun reflective index (SRI) of 100-110, having minimum elongation of 350% tensile strength of 2.9 Mpa and shall have cracks bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree celsius with 33% dilution of priming coat.(ii) Laying of fiber mesh of 0.3 mm thickness weave in leno pattern having 45 gsm/Sqm and pasting it properly with overlap of 50mm and allow it to dry. (iii) Apply second coat of undiluted coat @0.45 Ltr/Sqm.(iv) Apply third and final coat undiluted @0.45ltr/Sqm as directed by Engr in Charge.(a) M&L for 10mm thick cement rendering in CM1:3 and finishing the surface even and smooth before application of priming coat complete all as specified and directed. |