| 1 | M&L for Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft loosesoil complete all as specified and diretced. |
| 2 | M&L for PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) as in foundation filling, and mass concrete, complete all as specified and directed. |
| 3 | M&L for rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates, conforming toFe 410-W (Gde - E-250) quality - A, including two coats of synthetic ennamal paint over a coat of red oxide primer, complete all as specified and directed. |
| 4 | M&L for pre-painted galvalume aluminium zinc coating GI based corrugated coloured steel sheet, 0.50mm thick having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 5 | M&L for pre-painted galvalume aluminium zinc coating GI based plain steel coloured sheet, 0.50mm thick having tensile strength of 550 mpa, in ridges,hips, valley gutters, drip and straight flashings (length and girth as fixed) fixed with self tapping screws complete all as specified and directed. |
| 6 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, in soft/Loose Soil complete all as specified and directed. |
| 7 | M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling, and mass concrete, complete all as specified and directed. |
| 8 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 9 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed. |
| 10 | M&L for brick work with old size fly ash bricks straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed. |
| 11 | M&L for 15mm thick rendering on other than fair faces of brickwork or concrete surfaces in cement mortar 1:4 mixed with intigral waterproofing compound (WPC) @ 3% by weight of cement including two coats of cement base paintafter preparation of surface complete all as specified and directed.Note :WPC shall be measuredand paid seperatly under item No 17 here-in-after. |
| 12 | M&L for 15mm thick rendering on other than fair faces of brickwork or concrete surfaces in cement mortar 1:6 complete all as specified and directed. |
| 13 | M&L for Broken stone or boulders hardcore of gauge n exc. 63mm, deposited, spread andlevelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 14 | M&L for 100 mm thick cement concrete 1:3:6 type-C-2 (using 40mm graded stone aggregate) in Sub floors, Sub bases, Floors and Pavings, etc, finishedsurface even and even fair without using extra cement or /even and rough to receive the toping layer (as required) complete all as specified and as directed. |
| 15 | M&L for Coloured Non - skid Ceramic tiles 7 to 8 mm thickin floors etc.,area of each tile exc 0.06 sqm but n\" exc 0.11 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bedding in cement mortar (1:6) complete all as specified and as directed. |
| 16 | M&L for 75 mm thick PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in plinth protection, finishing concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 17 | Supply only integral water proofing compound of aprroved make complete all as specified anddirected.Note : Supplied WPC shall be used in item No 11 here-in above. |
| 18 | S&F stainless steel plate rack (utensil rack) of size (600mm x 750mm) & depth 300mm made with 0.63mm thick stainless steel sheet provided with brass screw including necessary fittings, nut/bolts fixed complete all as specified anddirected. |
| 19 | M&L for point wiring for light/fan/bell/buzzer/ exhaust fan with PVC insulated FRLS unsheathed single core cable of multistranded copper conductor of size 1.5 sqmm as phase & neutral drawn in and including PVC conduit medium grade not less than 20 mm dia, ISI marked, duly concealed to wall/floor or above false ceiling of suitable size with all fitting and accessories laid on wall/ceiling alongwith 1.5 sqmm stranded PVC insulated FRLS unsheathed copper conductor(Green in color) as earth wire and connected to common earth dolly for the following incl making goodto surface with CM(1:4) plaster and paint to matchthe surface complete incl provn of CI/pressed steel terminal switch boxand phenolic laminated sheet cover and fixed with brass screws cup washerfor fixing switches/socket/regulators etc complete all as specified and directed. |
| 20 | All as per Srl item No. 19 above but for one 3 pin, 5Amp socket out let on independent board using 2.5Sqmm size cable complete all as specifed and directed. |
| 21 | All as per Srl item No. 19 above but for 3 pin, 5Amp socket out let on the same board with other switch using 2.5Sqmm size cable complete all as specifed and directed. |
| 22 | All as per Srl item No. 19 above but for 5 pin, 15Amp socket out let on independent with other switch using 2.5Sqmm size cable complete all as specifed and directed. |
| 23 | S&Fswitch flush type, single pole, one way, 5/6 Amps 230 Volts complete all as specified and directed. |
| 24 | S&F socket outlet, flush type, suitable for 5/6 Amp, 2/3 pin complete all as specified and directed. |
| 25 | S&Fswitch socket combination 2 in 1, 6pin 16 Amp multipurpose type 230 volts complete all as specified and directed. |
| 26 | S&F ceiling rose, 3 terminal, PVC/ Polycarbonate, insulated body, surface Bakelite sheet 63.50mm dia complete all as specified and directed. |
| 27 | S&F sheet metal enclosure/Distribution board for MCBs, double door type, epoxy powder coated, factory made, Single Pole and Neutral (SPN), 4 way 240Volts with 200 Amps rated bus bar, with enclosure blank plates for unused way complete all as specified and directed. |
| 28 | S&F MCB , SP, AC, 240 volts of 06 to 32Amps capacity 10KA, \"C\" series including making connections with suitable size of copper lugs complete all as specified & directed. |
| 29 | S&F isolator SPN 40 Amp for earth leakage over load and short circuit protection ISI marked complete all as specified & directed. |
| 30 | S&F LED tube light fittings, 20/22 watt, 4 feet long,fixed to wall, complete all as specified and directed.Havells Cat Part: LHEXAPP7UN1W020 or equivalent make of Philips and Bajaj. |
| 31 | Supply and laying or fixing or passing through pipe, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 sq. mm, 2 corecomplete all as specified & directed. |
| 32 | S&F non integtal highbay LED flood light fitting, 200Wwith pressure aluminium die cast powder coating housing, opal milky diffuser, 750-1000 lux & frame with heat resistant, high efficiency toughne glass with EPDM gasket for IP66 protection complete assembly with LED, driver & accessories, pre-wired up to terminal box including connection on pole or buildingcomplete all as specified & directed.Philips Cat Part :- BVP158 LED240/WW NW CW PSU 200W SWB GM Havells Cat Part :- JETAPROPLUSFL200WLED757LTGBajaj Cat Part :- PRAZE F 240L WH NB-A5 TG SD |
| 33 | S&F mild steel tubes,galvanised as in post, piers, struts including embeding in concrete and screwing etc. ,cutting tops to shape as directed, drilling holes if required, necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 34 | Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10sq. mm4 core complete complete all as specified & directed.Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. |
| 35 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm nominal cross section,3 core in service connections (from junction box to street light)complete all as specified & directed. |
| 36 | S&F SMC Junction box with 4 Nos 63 A Aluminium Bus Bar, Din rail for MCB Mounting, inside dimension 250 x 250 x 160mmcomplete all as specified & directed. |
| 37 | S&F isolator SP40 amp 240 Volt\"B\" curve, breaking capacity 10 KAcomplete all as specified & directed. |
| 38 | M&L sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenchesand consolidated complete all as specified and directed.NOTE :Punned thickness of 18 cm shallonlybe considered for payment. |
| 39 | Supply and laying dry well burnt locally available brick sub class \"B\" modular bricks laid flat with width equal to the length of whole bricks over cable as cable protection complete all as specified and directed. |
| 40 | M&L for making/ boringhole under PCC road/ taxi track/ runway/ hard standing at a depth exc 450mm but n\"exc 1200mmfor passing cable through / insertion of40/50 mm dia GI pipe complete all as directed by Engineer-in-charge.NOTES :-(i)Cost of equipments, tools & plants,material required for boring shall be deemed to be included in unit quotedrates above. (ii)GI pipe shall be measured and paid separetely. |
| 41 | S&F for 40/50 mm dia GI pipe \"light grade\" ISI marked, fixed on wall/pole or laid in trenches/bore hole under road crossing/hard standingcomplete all as specified and directed. |
| 42 | Supply, installation, tasting and commitioning of300/320Ltrs capicity Deep freezer withhard top opening, single door 5 star rating, stabilizer free with easiely convertable to cooler modes from freezer mode or vis-a-vera, static cooling technology for consistent temperatures, designed with sturdy castor wheels at the bottom for easy mobility ,stucco aluminium inner liner for improved hygiene, UV grade plastic material for long lasting appearance, complete all as specfied and directed. |
| 43 | M&L for Sub main wiring with three single core PVC insulated unsheathed cable 4.0 sq.mm (nominal area) FRLS type multi stranded copper conductor of deffrent colour (Earth, phase and nutral) laying through20mm dia \"medium grade\"PVC conduit and fittings, including required cutting chases for conduit and sinken boxes, making gooddisturbed surfaces of wall so as to match the existing surfaces , connections to MCB/isolator complete all as specified and directed.NOTE:- (i) Cost ofPVC conduit and it\"s fittings deemed included in unit quoted rates. |
| 44 | S&F sheet metal enclosure with two pin and earth plug and socket 240 volts and including one 20 Amp MCB SPN, C-Curvecomplete all as specified & directed. |
| 45 | Supply, installation, tasting and commitioning ofwater cooler electric driven (single phase) having approx storage capacity of 180/150 ltrs and nominal cooling capacity of 150 Ltrs per hour with stainless steel tank complete all as specified & directed. |
| 46 | M&L for Sub main wiring with three single core PVC insulated unsheathed cable 2.5sq.mm (nominal area) FRLS type multi stranded copper conductor of deffrent colour (Earth, phase and nutral) drawn through20mm dia \"medium grade\"PVC conduit and fittings, including required cutting chases for conduit and sinken boxes, making gooddisturbed surfaces of wall so as to match the existing surfaces , connections to MCB/isolator complete all as specified and directed.NOTE:- (i) Cost ofPVC conduit and it\"s fittings deemed included in unit quoted rates. |
| 47 | M&L for GI steel tubing 15mm bore of medium grade with all fittings and fixed complete to walls/celling or laid in floors complete all as specified & directed. |
| 48 | S&F gun metal gate/globe valve 15mm bore with iron wheel head screwed both ends for pipe and fixed complete all as specified & directed. |
| 49 | Supply, installation, testing and commissioning of Split type air conditioner unit 2 Ton capacity (indoor and outdoor) having digital inverter rotary type compressor (single phase unit both), 220V-240V, 50Hz, 5 star rating and EER 3.2 with cordless remote control and necessary connections complete all as specified and directed.Note : The cost of copper tube/pipe of dia 1/2\" & 1/4\" (both together with insulation) up to 5M length shall deemed included in quoted rates.Addition tube if required shall be measured and paid seperatly under respective item here in under.Hitachi Cat Part :- YOSHI 5500STXLCarrier Cat Part :- INDUS Fxi SMART or equivalent makeof \" O General\". |
| 50 | S&F wall mount MS stand for outdoor unit of 2.0 Ton AC, universal size, heavey duty, fectory febricated, adjestable type including necessary fastnerscomplete all as specified and directed. |
| 51 | S&F copper tube/pipe of dia 1/2\" & 1/4\" both together with insulation and leak proof jointing complete all as specified and directed. |
| 52 | S&Fmultipurpose PVC hose pipeasas AC outlet drain water pipe complete all as specified and directed. |
| 53 | S&F automatic Voltage stablizer wall mounted, naturally cooled, indoor type, automatic boost/buck for low and high voltage correction equipped with electronic circuit, relays of single phase 50Hz AC supply, complete designed for input variaton Voltage of 130 to 280 volts and output voltage stablized at 230V with aacuracy of + 2.5% TDR to 3mm + 20 second of capacity 5 KVA capacity complete all as specified and directed. |
| 54 | S&F PVC AC modular surface box with combination 2 in 1, 5pin 5 Amp and 15 Amps with including heavy duty socket and 1x MCB SP 16/20 Amp complete all as specified and directed. |
| 55 | S&F sheet metal enclosure double door type, triple pole and neutral(TPN) 4 way 415 Volts with 200 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made(without MCB but inclusive ofenclosure blank plates for unused way)complete all as specified and directed. |
| 56 | S&F 4 Pole MCCB 125 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and directed. |
| 57 | M&L for Sub main wiring with three single core PVC insulated unsheathed cable 10 sq.mm (nominal area) FRLS type multi stranded copper conductor of deffrent colour (Earth, phase and nutral) drawn through20mm dia \"medium grade\"PVC conduit and fittings, including required cutting chases for conduit and sinken boxes, making gooddisturbed surfaces of wall so as to match the existing surfaces , connections to MCB/isolator complete all as specified and directed.NOTE:- (i) Cost ofPVC conduit and it\"s fittings deemed included in unit quoted rates. |
| 58 | S&F vegitable cooler of capacity 410 Ltr with A 5-star BEE rating, temperature range maintains between 0⁰C to 7⁰C, ideal for beverages, dairy and perishables 4/5 adjustable shelves for better organization and added storage space, featuring a tempered glass door with a glow sign with LED lighting to enhance visibility, with sSpecial Features like Wheels easy mobility, Special Baskets, Heavy Duty shelves, UV grade plastic for long lasting appearance, Anti-corrosive body, Tropicalized machines etc complete all as specified and directed. |
| 59 | S&F MS body 300mm sweep heavy duty exhaust fan,with louvers, fixing arrangment/ bracket and electric connection complete all as specified and directed. |
| 60 | M&L for makinground / rectangular holethrough wallsfor exhaust fan of 300mm size and making good the disturbed surface as per existing complete all as specified and directed. |
| 61 | Carry out the detail energy audit of all the EM assets installed at Varanasi Cantt. The energy audit shall consider the following parameters while doing the survey of the stnPower Distribution SystemMeasurement and analysis of plant demand, power factor to suggest measures to reduce the maximum demand.* Detailed examination of the existing energy use pattern of the facility with break-up.* Measurement and analysis of demand and power factor, suggestions to reduce the demand if possible.* Performance evaluation of Motors, 5 kW and above, to identify under/over loading of motors and power factor improvement.* Analysis of loading pattern and losses in Transformers.* Standby systems are not included in scope. 4* Measurement and analysis of voltage, current, power factor, active power, reactive power, neutral current, voltage variations, frequency* Measurement of Electrical parameters like Voltage, Current, kW, Power Factor,Voltage harmonic distortion (V THD %), current harmonic* Recommendation to improve the power quality, power factor improvement, reduction in harmonic levels, if any, to comply with IEEE 519NOTE: All details mentioned in PARTICULAR SPECIFICATIONSSl Page No. 164 |