| 1 | Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed. |
| 2 | Material andlabourfor6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc fixed with L-type or J- type or cranked hook bolts complete all as specified and as directed. |
| 3 | Description all asper item No 2 abovebut except AC sheet complete. |
| 4 | Material andlabourfor asbestos cement two- piece adjustable plain wing ridge 6mm thickfixed with L-type or J- type or cranked hook bolts complete all as specified and as directed. |
| 5 | Dismantling of Plain or corrugated/galvalume steel sheeting, any gauge, thickness, including Nainital orsimilarpattern roof coverings complete all as specified and as directed. |
| 6 | Supply and fixforpre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 7 | Supply and fixforpre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 9 | Supply and fix rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe-410 W(Gde E-250) quality B complete all as specified and as directed. |
| 10 | Supply and fixsteel work in tubular trushes including special shaped washer etc complete using ERWor induction but welded tubes confirming to I.S. 1161-1979 grade St. 240 etc as in purlins complete all as specified and as directed. |
| 11 | Excavating in post holes each n.exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance n.exc 50 m and making good surfacecomplete all as specified and as directed. |
| 12 | Material and labour for cement conc 1:3:6 type C-2 (40 mm graded aggregate) as in Foundation filling,mass concrete etc. complete all as specified and as directed. |
| 13 | Material and labour for preparation of new steel and iron surfaces of any description over 10cms width or girth & applying 2 coats of synthetic enamel paint over one coat of red oxide primercomplete all as specified and as directed. |
| 14 | Dismantling ofwall and ceiling boards (fibre,pulp insulation, Ac etc), any thickness including cover filletscomplete all as specified and as directed. |
| 15 | Supply and fixinterlocking aluminium alloy anodised snap grid consists of main Tee runners of size 38mm x25mm x1.5mm spaced 1200mm centre to centre and cross Tee of size 25mmx25mmx 1.5mm, 1200mm long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mmx600mm and provide a secondary cross tee 25mm x1.4mm ( of length 600mm)to be interlocked of the centre of 1200mmx600mm panel to form a grid of 605mmx605mm and wall angle 25mmx25mmx 2mm. Aluminium alloy extruded section shall be aluminium anodised (minimum 15 micron ) and shall conform to IS 733, IS 1285 and IS 737. including Hangers of GI wire 6mm dia to be fixed by approved rawl plug, level and justers and screws etc. complete all as specified and as directed. |
| 16 | Material andlabour for 7-8 mm thick gypsum board/tiles for insulation and accoustic purposes, 60cmx60cm in size , fixed with nails to timber frame work or with staples on snap grid in ceilingcomplete all as specified and as directed. |
| 17 | Dismantling of floor hearth or wall tiling including cm bedding (but not backing) removing serviceable tiles in store rubbish of the premisescomplete all as specified and as directed. |
| 18 | Material and labour for 15 mm thick screed bed or bedding layer in cement mortar (1:6)complete all as specified and as directed . |
| 19 | Material andlabour for glazed ceramic colouredtiles in vertical surface 600 X300 7/350x400 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick cement plaster (1:4) as backing coat complete all as specified and as directed. |
| 20 | Material andlabour for vitrified ceramic tiles 7-9 mm thick light shade, (square/rectangular) polished, area of each tiles exceeding 0.36 Sqmn.exceeding 0.42 in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match overcomplete all as specified and as directed. |
| 21 | Descriptin all as per item No.20 above but as in skirting over,including 10mm thick plaster in CM(1:4) complete all as specified and as directed . |
| 22 | Material andlabour fornon - skidcoloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match overcomplete all as specified and as directed. |
| 23 | Descriptin all as per item No.22above but as in skirting over, including 10mm thick plaster in CM(1:4) complete |
| 24 | Material andlabourfornon - skidcolouredceramic tiles 7 to 8 mm thick (square/ rectangular) area of eachtile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match overcomplete all as specified and as directed. |
| 25 | Demolition of precast concrete block /brick work walling built in cement mortar complete all as specified and as directed. |
| 26 | Taking down cement plaster on wall /concrete surface etc including racking out joints hacking for key scrubing down with water etc complete all as specified and as directed. |
| 27 | Material andlabour for precast cement concrete block masonry using type C1 1:3:6 (20 mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in mortar1:6complete all as specified and as directed. |
| 28 | Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6complete all as specified and as directed. |
| 29 | Material andlabourfor rendering 15mm thick on blockmasonry surfaces or surface other than fair face of brick work or on side of lathing in cement plaster 1:4 complete all as specified and as directed. |
| 30 | Material and labour for preparing new plastered and applying two coat of cement based paint (any tint) over a coat of primer on walls complete all as specified and as directed. |
| 31 | Material andlabour for rendering 15 mm thick on blockmasonry surfaces or surface other than fair face of brick work or on side of lathing in cement plaster 1:6 complete all as specified and as directed. |
| 32 | Taking down chowkats or frames with shutters without taking of shutters from the frames n exc 1.5 Sqm butincluding all as specified and as directed |
| 33 | Taking down chowkats or frames with shutters without taking of shutters from the frames exc 1.5 Sqm but not exc 4 Sqm each including all as specified and as directed. |
| 34 | Taking down shutter exc. 1.00 Sqm but n.exc. 2.00 Sqm each and removing from sitecomplete all as specified and as directed. |
| 35 | Supply and fixsolid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification & drawing shown on Page No. 160 of SSR 2010 part II. complete all as specified and as directed. |
| 36 | Supply and fix30mm thick FACTORY MADE MOULDED DOOR SHUTTER ‐ WOOD FREE consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 25mm x 25mm for stiles, top and bottom rails. M. S. frame shall have a coat of steel primers. The inner panel shall consist of 25mm thick EPS of density 23 Kg /Cbm. bonded with 2mm thick termite proof, water proof and fire resistant moulded PVC Sheet Manufactured by an ISO‐9001‐2015 certified company, with 2, 4, 6 raised panel design in different plain and / or prelam colours after routing the Moulded design on one side & 2mm plain and /or prelam PVC sheet on other side of the EPS. The edge of panel to be sealed with lipping of 15mm wide PVC sheet baton ( made by sticking 2mm rigid foam PVC sheets of 5mm (±0.25) thickness using PVC solvent cement ) and stile sides 25mm (5mm x 5nos.) thick and 30mm width PVC Sheet fitted along M.S. tube for hardware provision & for lock25mmthick ( 5mmx5nos. ) PVC sheet of size 150mm x 200mm fixed with inner side of EPS Panel etc. complete all as per specification & drawing and as directed. |
| 37 | Supply and fixfor pressed steel door frames of size 105 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete all as specified and as directed. |
| 38 | Material and labour for PCC 1:2:4 type B1 in door frame back filling, hold fasts complete all as specified and as directed. |
| 39 | Supply and fix factory made shutter 35mm thick, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressuretreated complete all as specified and as directed. |
| 40 | Supply and fix30mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and asdirected. |
| 41 | Material andlabour for two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces including all necessary preparation over 10 cms width or girth complete all as specified and as directed. |
| 42 | Supply and fix stainless steel100 mm size butt hinges, medium weightcomplete all as specified and as directed. |
| 43 | Supply and fixaluminium handles 150 mm long,cast type anodised complete all as specified and as directed. |
| 44 | Supply and fixaluminium anodised, barrel tower bolt 150mm long, powder coated of extruded section and fixed complete all as specified and as directed. |
| 45 | Supply and fixin repair aluminium alloy, anodised, sliding door bolt 200mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy 12mm dia, complete all as specified and as directed. |
| 46 | Supply and fixfor powder coated aluminium sliding windows having three Nos of tracks including one wire glazed shuttersfor mosquito proofing including stainless steel wire cloth of 0.63 mm nominal dia and average aperature1.4 mmand two Nos glass shutters including 4mm thick coloured glass and aluminium section weight n.less than 0.55 Kg/RM including necessary cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, suitable handles, locking arrangement and fixed to stone masonry wall complete all as specified and as directed.NOTE:- colour of powder coating should be brown/wood grain in colour. |
| 47 | Supply and fixfor frame work such as grill, grating etc with ends bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors and similar work confirming to Fe 290 Gde E-165 complete all as specified and as directed. |
| 48 | Supply and fixfor powder coated anodised aluminiumventilator shutters, fixed type without sash bar including stainless steel wire cloth of 0.63 mm nominal dia and average aperature1.4 mm, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc.and fixed to stone masonry wallincludingdemolition of RCC jali ventilators complete all as specified and as directed. |
| 49 | Supply and fixfor plain, galvanised mild steel sheeting, in ridges, hips,Valley gutters, drip and straight flashing (length and girth as fixed) by using 1.00 mmthick grade of zinc coating @120Gms/Sqm both sides and welded or soldered joints are provided complete including making shapes to valley gutter. all as specified and as directed. NOTE:-i) Contractor should work at height upto 10mtr w/o any extra payment.ii) Necessary Scaffolding required for valley gutter should be arranged by contractor.iii) Necessary arrangement of safety measure of labour working at height should be procured by the contractoriv) Rate for scaffolding for working at height and safety measure tools forlabour should be included in quoted rate & no extra payment given to contractor. |
| 50 | Supply, fabrication and fixing PVC valley gutter of approved make, heavy duty, UV-stabilised, suitable for roof rainwater drainage, of required width and depth, including MS / GI brackets, clamps, jointing with solvent cement / rubber seals, end caps, outlets, fixing to roof structure at proper slope, testing for leak-proof performance and making good disturbed surfaces, complete all as specified and as directed. |
| 51 | Supply and fixfor plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-W(Gde E- 250) quality-A complete all as specified and as directed. |