|
| 1 | French spirit polishing : One or more coats on old work |
| 2 | Painting with synthetic enamel paint of approved brand(Asian/Nerolac/Berger or equivalent) and manufacture of required colour to give an even shade :One or more coats on old work |
| 3 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand( Birla/JK or equivalent) and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 4 | Applying priming coats with primer of approved brand(Asian/Nerolac/Berger or equivalent) and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 5 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 6 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand (Asian/Nerolac/Berger or equivalent)and manufacturer including applying additional coats wherever required to achieve even shade and colour : Old work (Two or more coats) |
| 7 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelingto be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 8 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required : Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 9 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge : With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 10 | Providing and fixing aluminium handles, ISI marked, Powder coated, required colour or shade, with necessary screws etc. complete : 125 mm |
| 11 | Providing and fixing aluminium tower bolts, ISI marked,Powder coated,required colour or shade, with necessary screws etc. complete : 150x10 mm. |
| 12 | Grinding and polishing of existing floor including labour T&P material complete in all respect at site as per direction of engineer -in -charge. |
| 13 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below. |
| 14 | Providing and fixing vertical venation blinds(Regular) 100mm size of MAC or equivalent in required colour as approved by the Engineer-in-charge complete in all respect including operating sysyem, carriage and wastage etc. complete in all respect at site as per direction of engineer in-charge. |
| 15 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping groundwithin 50 metres lead :With cement mortar 1:4 (1 cement : 4 fine sand) |