Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORKS---EARTH WORK EXCAVATION |
| 2 | DSR 2023-2.6 Earth work in excavation by mechanical meansHydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer- Incharge |
| 3 | All Kinds of soil |
| 4 | FILLING AVAILABLE EXCAVATED EARTH |
| 5 | DSR 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | DRESSING AND FILLING |
| 7 | DSR 2.28 Surface dressing of the ground including removing vegetation and in equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m |
| 8 | FILLING EARTH BROUGHT FROM OUTSIDE |
| 9 | DSR 2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete up to any lead |
| 10 | CONCRETE |
| 11 | DSR 4.18, 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from naturalsources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 12 | DSR 5.1.2, Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 13 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | PILE |
| 15 | DSR-20.3.1 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured up to to the bottom of pile cap)-300 MM DIA PIPES |
| 16 | REINFORCEMENT |
| 17 | DSR-5.22.6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 18 | DSR-5.22 A Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 19 | FORM WORK |
| 20 | DSR 5.9.1Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 21 | DSR 5.9.5Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 22 | DSR 5.96 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 23 | BRICK WORK |
| 24 | DSR 6.30.1 Brick work with common burnt clay machine moulded perforated F.P.S. (non modular) bricks of class designation 12.5 conforming IS : 2222 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand).-From ground level up to plinth level |
| 25 | DSR 6.30.2Brick work with common burnt clay machine moulded perforated F.P.S. (non modular) bricks of class designation 12.5 conforming IS : 2222 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand).-Above plinth level up to floor V level |
| 26 | DSR 6.12 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : |
| 27 | ROOFING |
| 28 | DSR 10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 29 | DSR 12.8 Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete(excluding the cost ofpurlins, rafters and trusses), including cutting sheets to size and shape wherever required |
| 30 | DSR 12.12.1 Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. Corrugated serrated adjustable ridges |
| 31 | FLOORING |
| 32 | DSR113.1 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as perManufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete |
| 33 | DSR 11.3-Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.-40 mm thick with 20 mm nominal size stone aggregate |
| 34 | DSR 8.31- Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shadecomplete. |
| 35 | DSR 11.37A Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete |
| 36 | DSR 11.41.2 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 37 | DSR 11.41.A3.1 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 11.41A.3.1 Size of Tile600 x 600 mm |
| 38 | DSR 16.68 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 39 | DSR 16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). Size 450mmx450mmx150mm |
| 40 | MR Providing and laying 300 mm thick granular sub base for hard strand (size of soling 60mm-150mm) |
| 41 | PLASTERING |
| 42 | DSR 13.6.120 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) |
| 43 | DSR 13.5 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 44 | PAINTING |
| 45 | DSR 13.83.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two Coats |
| 46 | DSR 13.85.3 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 47 | DSR 13.48A.1 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. |
| 48 | MR-Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications preparation of surface, etc. complete ON STEEL WORK |
| 49 | UPVC WINDOWS |
| 50 | DSR 9.147A.3Providing and fixing factory made uPVC white colour cement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window up to 2.50 sqm). |
| 51 | UPVC DOORS |
| 52 | DSR 9.147C.2 Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made: Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable: Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door up to 2.50 sqm) |
| 53 | FALSE CEILING |
| 54 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and |
| 55 | DSR 16.7 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade |
| 56 | MR Providing and fixing 15x15x210 cm boundary stone of hard stone(cost of excavation, refilling and concrete etc. to be paid for separately) |
| 57 | DSR 21.2.2 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. leveladjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately) |
| 58 | DSR 21.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge . Pre-laminated particle board with decorative lamination on both sides |
| 59 | DSR 21.3.1. Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 60 | DSR 21.4.2 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in-charge. With brass cover plate minimum 1.25 mm thickness |
| 61 | HDPE LINER |
| 62 | MARKET RATE- Providing and fabrication of 1.0mm or 1000 GSM HDPE Smooth Geomembrane (Black).Black-pigmented, ultra-smooth HDPE geomembrane engineered for superior resilience and performance under rigorous operational conditions, particularly within aquaculture systems |
| 63 | MARKET RATE-Horizontal and vertical G.I pipes both ways 40mm dia G.I Pipes at the intervel of600mm alround as per the detailed drawings, Vertical support pipes are to be installed at precise intervals, extending to a minimum depth of 0.5 feet below the ground surface. These pipes must be securely anchored within a foundation of high-strength concrete, designed to provide maximum resistance against soil displacement and environmental stressors. The concrete mix should be carefully prepared with an optimized water-cement ratio to achieve superior compaction and curing, ensuring that the pipes remain rigidly fixed and capable of withstanding dynamic loads and environmental fluctuations over an extended operational lifespan. |
| 64 | MARKET RATE- Removal, re-laying, and welding of the existing 1000-micron thick HDPE liner sheet using a combi-wedge welding machine, including necessary arrangements, alignment, and complete finishing of the work |
| 65 | MARKET RATE- Providing and fixing 15 cm wide, 45 cm overall semi-circular PVC/UPVC Rain water gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes at suitable intervals complete |
| 66 | SANITARYPLUMBINGWORKS |
| 67 | DSR 17.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 68 | DSR 17.22 A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 69 | DSR 17.3Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever requiredW.C. pan with ISI marked white solid plastic seat and lid |
| 70 | DSR 18.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms: 15 mm nominal bore |
| 71 | DSR 18.49.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms15 mm nominal bore |
| 72 | DSR 18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931.15mm nominal bore |
| 73 | DSR 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms |
| 74 | DSR 17.34.1 Providing and fixing toilet paper holder : C.P. brass |
| 75 | DSR 17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 76 | DSR 17.16 A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 77 | DSR 17.24 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe |
| 78 | DSR 19.4.3.1 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 180x150 mm size P type: With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 79 | DSR 19.2 Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg |
| 80 | DSR 17.22B Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. |
| 81 | DSR 18.58.2.1Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid:150 mm nominal size square 100 mm diameter of the inner hinged round grating |
| 82 | DSR 18.22.2 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter |
| 83 | DSR 18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 |
| 84 | MARKET RATE- Providing and fixing Floor trap standard design and of approved make conforming to IS:8931 |
| 85 | MARKET RATE-Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 650x450mm |
| 86 | AQUACULTURE PLUMBING WORK |
| 87 | MARKET RATE- Supplying and fixing in position best quality PVC pressure pipes of sea water supply of various size having ISI mark, with 16 Kgs of pressure, non corrosive and non contact with the salt water of Conforming the IS 4985 : 2000 and providing leak proof joints including fixing to the wall specials PVCClamps, etc and making connection to fittings, dismantiling masonary /RCC work wherever necessary and making good the dismantled portion to the original condition. IS -4985,DIN -8062. |
| 88 | 25 mm dia 16 kgf/cm2 PVC pipe |
| 89 | 32 mm dia. 16 kgf/cm2 PVC Pipe |
| 90 | 50 mm dia 16 kgf/cm2 PVC Pipe |
| 91 | 90 mm dia. 10 kgf/cm2PVC Pipe |
| 92 | 110mm dia. 10 kgf/cm2 PVC pipes. |
| 93 | 140 mm dia 6 kgf/cm2 pvc pipe. |
| 94 | 160mm dia 6 kgf/cm2s PVC pipes. |
| 95 | 200 mm dia 6 kgf/cm2 pvc pipes |
| 96 | 250mm dia. 6 kgf/cm2PVC Pipes |
| 97 | 300 mm dia 6 kgf/cm2 PVC Pipe |
| 98 | 63mm dia. 6 kgf/cm2sPVC Pipe |
| 99 | MARKET RATE- Providing and fixing Chlorinated Polyvinyl chloride(CPVC) pipes having thermal stability for sea water supply ,including all CPVC plainthreaded fittings, including fixing the pipe with clamps at 1.00m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. |
| 100 | 25mm CPVC pipe |
| 101 | 32 mm CPVC pipe |
| 102 | 50 mm CPVC pipe |
| 103 | 90 mm CPVC pipe |
| 104 | MARKET RATE- Providing and fixing u-PVC pipes having thermal stability for sea water supply ,including all u-PVC plainthreaded fittings, including fixing the pipe with clamps at 1.00m spacing this includes jointing of pipes & fittings with one step u-PVC solvent cement and testing of joints complete as per direction of engineer in charge. |
| 105 | 25mm u-PVCpipe |
| 106 | 32 mm u-PVC pipes |
| 107 | 50 mm u-PVC pipes |
| 108 | 63 mm u-PVC pipes |
| 109 | 90 mm u-PVC pipes |
| 110 | MARKET RATE- Supply and fixing of PVC ELBOW complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 111 | 25 mm dia |
| 112 | 32 mm dia |
| 113 | 50 mm dia |
| 114 | 63 mm dia |
| 115 | 90 mm dia |
| 116 | 110mm dia |
| 117 | 160mm dia |
| 118 | 200mm dia |
| 119 | 250 mm dia |
| 120 | MARKET RATE- Supply and fixing of PVC TEE complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 121 | 32 mm dia |
| 122 | 50 mm dia |
| 123 | 63 mm dia |
| 124 | 90 mm dia |
| 125 | 110mm dia |
| 126 | 160mm dia |
| 127 | 200mm dia |
| 128 | 250mm dia |
| 129 | MARKET RATE- Supply and fixing of PVC reducer union complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 130 | 63 /25 mm dia |
| 131 | 63 /32 mm dia |
| 132 | 50 / 32 mm dia |
| 133 | 110 /50 mm dia |
| 134 | 110/63 mm dia |
| 135 | 250/160 mm dia |
| 136 | 200/160 mm dia |
| 137 | 250/200 mm dia |
| 138 | 160/110mm dia |
| 139 | 110/90mm dia |
| 140 | MARKET RATE-Supply and fixing of PVC end cap complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 141 | 25 mm dia |
| 142 | 32 mm dia |
| 143 | 50 mm dia |
| 144 | 63 mm dia |
| 145 | 90 mm dia |
| 146 | 110mm dia |
| 147 | 250mm dia |
| 148 | MARKET RATE- Supply and fixing of PVC reducer TEE complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 149 | 63 /25 mm dia |
| 150 | 63 /32 mm dia |
| 151 | 50 / 32 mm dia |
| 152 | 110 /50 mm dia |
| 153 | 110/63 mm dia |
| 154 | 250/160 mm dia |
| 155 | 200/160 mm dia |
| 156 | 250/200 mm dia |
| 157 | 110/90 mm dia |
| 158 | 160/110 mm dia |
| 159 | MARKET RATE- Supply and fixing of PVC MT/FTA complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all |
| 160 | 25 mm dia |
| 161 | 32 mm dia |
| 162 | 50 mm dia |
| 163 | 110 mm dia |
| 164 | 63 mm dia |
| 165 | 160 mm dia |
| 166 | 200 mm dia |
| 167 | 250 mm dia |
| 168 | 90 mm dia |
| 169 | MARKET RATE- Supply and fixing of 10 kgs of PVC Ball valve with complete all |
| 170 | 32 mm dia PVC Ball valve |
| 171 | 50 mm dia pvc ball valve |
| 172 | 90 ( 80 mm) mm dia PVC Valve |
| 173 | 110 ( 100 ) mm dia PVC Valve |
| 174 | MARKET RATE-Supply and fixing of PVC foot cum check valve complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 175 | 50 /63 mm dia |
| 176 | 110 mm dia |
| 177 | MARKET RATE-Supply and fixing of PVC Non returnvalve complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 178 | 50 /63 mm dia |
| 179 | 110 mm dia |
| 180 | MARKET RATE-Supply and fixing of 300 mm dia air diffuser in disk model complete, coverage area of 3 to 6 sqm minimum of 1.8 water depth complete all. |
| 181 | MARKET RATE- Supply and fixing ofHigh rigid PVC white colour butterfly valve, PVC Hubs, ABS body, center shaft will be no corrosive 304SS, Paddle -304SS, seals - Sarlink or equivalent withstand pressure of 10, with both side connecting pipe complete all. |
| 182 | 110mm PVC butterfly valve |
| 183 | 160mm PVC butterfly valve |
| 184 | 200mm PVC butterfly valve |
| 185 | Supply and fixing of pvc flanges with SS bolts and nuts with water leak gasket to be provided complete all. |
| 186 | Flanges for 110 mm dia |
| 187 | Flanges for 250 mm dia |
| 188 | Flanges for 160 mm dia |
| 189 | MARKET RATE-Supply and fixing of u-PVC/CPVC TEE complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 190 | 25 mm dia |
| 191 | 32 mm dia |
| 192 | 50 mm dia |
| 193 | 63 mm dia |
| 194 | MARKET RATE-Supply and fixing of u-PVC/CPVC Elbow complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 195 | 25 mm dia |
| 196 | 32 mm dia |
| 197 | 50 mm dia |
| 198 | 63 mm dia |
| 199 | MARKET RATE-Supply and fixing of u-PVC/CPVC MTA/FTA complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 200 | 25 mm dia |
| 201 | 32 mm dia |
| 202 | 50 mm dia |
| 203 | 63 mm dia |
| 204 | MARKET RATE-Supply and fixing of u-PVC/CPVC Ball valve complete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 205 | 25 mm dia |
| 206 | 32 mm dia |
| 207 | 50 mm dia |
| 208 | 63 mm dia |
| 209 | MARKET RATE-Supply and fixing of u-PVC/CPVC End capcomplete all using to fix the same in the pipe using the emery sheet with using the solvent to fix the same complete all. |
| 210 | 25 mm dia |
| 211 | 32 mm dia |
| 212 | 50 mm dia |
| 213 | 63 mm dia |
| 214 | MARKET RATE-Supply and fixing of L shaped HDPE stand support of size 600mmx12mm on both ways to fix on walls above floor levelof 2.5 meters high,. PVC/CPVC/U-PVC pipes carriying sea water to run on top of the support, The L support to be fixed in wall using12mm dia 100 mm length anchor bolts |
| 215 | MARKET RATE-Supply and erection of beach bore- 3 nos of suitable interval of4 inch 6 Kgf/sq.cm PVC pipes and fittings 20 feet deep. The PVC pipe shall be slotted with 15 feet length at the bottom of bore covered with nylon mesh near to sea waves with necessary earth work using hydralic excavator and required redsand for back filling during boring. The three nos ofdelivery of pipe shall be connected to10HP intake pumpsfor a length ofapproximately 45 meters with all necessary pipes and fittings and 4 inch Non return valve complete finishing of work with all materials |
| 216 | ELECTRICAL WORKS |
| 217 | CPWD DSR (E&M 2022) 2.5.2 Supplying and Fixing of following Ways surface/recess Mounting Vertical Type 415V TPN MCB Distribution board of sheet steel, Dust Protected,Duly Powder painte,inclusive of 200A tinned Copper busbar,Common neutral link,Earth bar,din bar for mounting MCBs(But without MCBs and incomer) as required.(Note Vertical type MCB TPDB is normally used where 3 Phase Out lets are required) |
| 218 | CPWD DSR(E&M 2022) 2.5.2 8 Way (4+24),Double Door |
| 219 | Market Rate Supply and Fixing 63A Polerating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required |
| 220 | CPWD DSR(E&M 2022) 2.10 Supply and Fixing 32A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 221 | CPWD DSR(E&M 2022)2.10.4 Tripple Pole |
| 222 | CPWD DSR(E&M 2022) 2.10Supply and Fixing 10 A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 223 | CPWD DSR(E&M 2022) 2.10.1 Single Pole |
| 224 | Market Rate Supply and Laying of 16 Sq.mm 4 Core PVC Sheathed ,XLPE Insulated Multi Core Bright Annealed Bare Copper Conductor Heavy duty Armoured Industrial Cable For Voltage up to 1100 Volts as per the IS:694:1990 with supply and Installation of Suitable Cable gland and suitable Copper Lug and End termination etc that cable to be lay through PVC conduit 32 mm and supply of PVC pipe ,PVC Bend,PVC Clamp and installation of Clamp and accsoriesincluded etc. |
| 225 | CPWD DSR (E&M 2022)7.1 Laying One number PVC insulated and PVc Sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,Protective covering and refilling the trench etc as required |
| 226 | CPWD DSR (E&M 2022) 7.1.1 Upto 35 Sqmm |
| 227 | Market Rate Supply and Laying of 4 Sq.mm 3 Core PVC Sheathed ,XLPE Insulated Multi Core Bright Annealed Bare Copper Conductor Heavy duty Armoured Industrial Cable For Voltage up to 1100 Volts as per the IS:694:1990 with supply and Installation of Suitable Cable gland and suitable Copper Lug and End termination etc, that cable to be lay through PVC conduit 32 mm and supply of PVC pipe ,PVC Bend,PVC Clamp and installation of Clamp and accsoriesincluded etc. |
| 228 | Market Rate: Removal of Existing 2HP-10HP Starter 1 Nos and remove the connection andProviding and Fixing the 63A TPN SDFCapacity TP&N disconnector Fuse switch Unit inside the Existing Panel Board with ISI Marked HRC Fuses including Drilling holes in Cubicle Panel,Making Connections by suitable cable with proper Insullation and remove the Indicaion Lamps and Cover the Indication Lamp slotted Area by proper arrangemnts and removal of Existing 32A TPN Swictch and make the arrangements to fix the63A TPN SDF with providing the proper safety arrangementsetc as required supply and installation of suitable HRC Fuse rating 63A |
| 229 | Market Rate: Supply Installation and Commissioning of 10 HP Wall Mounted Star Delta Starter for 10 HP ,3 phase 415Volt,50Hz MotorStarter with Analog Voltmeter,Analog Ammeter,Insulated Material push bottons,Indication Lampswith Suitable ORL relay and suitable Contactors including the Wall mounting arrangements and Earthing Connectionsand End Termination work included from Existing DB to Starter and Starter to Motor with available cablesin Motor with Suply of Suitable Cable Lugs and cable Gland also included and etc as required (Motor To Starter Cable Supply Not in the Scope) ( Starter warranty-1 Year) |
| 230 | Market Rate Supply Installation and Commissioning of 5 HP Wall Mounted Star Delta Starter for 5 HP ,3 phase 415Volt,50Hz MotorStarter with Analog Voltmeter,Analog Ammeter,Insulated Material push bottons,Indication Lampswith Suitable ORL relay and suitable Contactors including the Wall mounting arrangements and Earthing Connectionsand End Termination work included from Existing DB to Starter and Starter to Motor with available cablesin Motor with Suply of Suitable Cable Lugs and cable Gland also included and etc as required (Motor To Starter Cable Supply Not in the Scope) (Starter make should be L&T,Seimens,ABB,Crompton) ( Starter warranty-1 Year) |
| 231 | Market Rate: Removal of Existing 2HP-10HP Starter 1 Nos and remove the connection andProviding and Fixing the 63A TPN SDFCapacity TP&N disconnector Fuse switch Unit inside the Existing Panel Board with ISI Marked HRC Fuses including Drilling holes in Cubicle Panel,Making Connections by suitable cable with proper Insullation and remove the Indicaion Lamps and Cover the Indication Lamp slotted Area by proper arrangemnts and removal of Existing 32A TPN Swictch and make the arrangements to fix the63A TPN SDF with providing the proper safety arrangementsetc as required supply and installation of suitable HRC Fuse rating 63A |
| 232 | CPWD DSR (E&M 2022) 2.5.2 Supplying and Fixing of following Ways surface/recess Mounting Vertical Type 415V TPN MCB Distribution board of sheet steel, Dust Protected,Duly Powder painte,inclusive of 200A tinned Copper busbar,Common neutral link,Earth bar,din bar for mounting MCBs(But without MCBs and incomer) as required.(Note Vertical type MCB TPDB is normally used where 3 Phase Out lets are required) |
| 233 | CPWD DSR (E&M 2022) 2.5.2 8 Way (4+24),Double Door |
| 234 | Market Rate: Supply and Fixing 63A 4 Polerating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required (Mark ISI) Make: Legrand/Schneider/L&T/Seimens |
| 235 | CPWD DSR(E&M 2022) 2.10 Supply and Fixing 32A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 236 | CPWD DSR (E&M 2022) 2.10.4 Tripple Pole |
| 237 | CPWD DSR (E&M 2022) 2.10Supply and Fixing 10 A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 238 | CPWD DSR (E&M 2022) 2.10.1 Single Pole |
| 239 | Market Rate:Supply and Laying of 16 Sq.mm 4 Core PVC Sheathed ,XLPE Insulated Multi Core Bright Annealed Bare Copper Conductor Heavy duty Armoured Industrial Cable For Voltage up to 1100 Volts as per the IS:694:1990 with supply and Installation of Suitable Cable gland and suitable Copper Lug and End termination etc that cable to be lay through PVC conduit 32 mm and supply of PVC pipe ,PVC Bend,PVC Clamp and installation of Clamp and accsoriesincluded etc. |
| 240 | CPWD DSR(E&M 2022)7.1 Laying One number PVC insulated and PVc Sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,Protective covering and refilling the trench etc as required |
| 241 | CPWD DSR(E&M 2022)7.1.1 Upto 35 Sqmm |
| 242 | Market Rate: Supply Installation and Commissioning of 20 HP Wall Mounted Star Delta Starter for 20 HP ,3 phase 415Volt,50Hz MotorStarter with Analog Voltmeter,Analog Ammeter,Insulated Material push bottons,Indication Lampswith Suitable ORL relay and suitable Contactors including the Wall mounting arrangements and Earthing Connectionsand End Termination work included from Existing DB to Starter and Starter to Motor with available cablesin Motor with Suply of Suitable Cable Lugs and cable Gland also included and etc as required (Motor To Starter Cable Supply Not in the Scope) |
| 243 | CPWD DSR (E&M 2022)5.14 Providing and Fixing 25mm X 5mm Copper strip on Surface or in recess for Connections etc. as required |
| 244 | CPWD DSR (E&M 2022)1.7 Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 245 | CPWD DSR (E&M 2022)1.7.3 2X4 Sq.mm + 1X 4 sq.mm earth wire |
| 246 | CPWD DSR (E&M 2022)1.7 Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 247 | CPWD DSR (E&M 2022)1.7.2 2X2.5 Sq.mm + 1X 2.5 sq.mm earth wire |
| 248 | Power Switch Box in New Seawater Intake Pump Room |
| 249 | CPWD DSR (E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 250 | CPWD DSR(E&M 2022)1.27.4 6 Module (200mm X75mm) |
| 251 | CPWD DSR (E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 252 | CPWD DSR (E&M 2022)1.27.4 6 Module (200mm X75mm) |
| 253 | CPWD DSR (E&M 2022)1.26 Supply and Fixing modular blanking plate on the existing modular Plate & Switch Box excluding Modular Plate as required |
| 254 | CPWD DSR (E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 255 | CPWD DSR (E&M 2022)1.24.1 5/6 A switch |
| 256 | CPWD DSR (E&M 2022)1.24.3 15/16A Switch |
| 257 | CPWD DSR(E&M 2022)1.24.5 6 pin 15/16 A Socket outlet |
| 258 | CPWD DSR (E&M 2022)1.10 Wiring for Light Point/Fan Point/Exhaust fan Point/call bell point with 1.5 Sqmm FRLS PVC Insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch ,Modular plate,Suitable GI box and Earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 259 | CPWD DSR (E&M 2022)1.10.3 Group C |
| 260 | Market Rate Supply and Installation and Comissioning of LED Tube light 34/36 WColour Temperature 6500K Cool day light,Luminous flux 2100 lm 140 -270 Volt AC 50 Hz IP 65 Batten Material Polycorbonate 4 feet Type and Clamp fixing acceesoriesincludedIndoor Indusrial Application |
| 261 | Market Rate Supply of 3 mtr long 50 mm dia G.I pipe with flat buried in ground with back filling compound in an earth pit mixed with sand in alternate layers of 150mm each up to a height of 2550mm from bottom. The pipe shall have provision for connecting earth flats / wires. Including accessories and Providing masonry Enclosure with cover plate |
| 262 | Market Rate Supply of earth plate of size 600 x 600 x 3mm copper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each upto a height of 3000mm from bottom. Two copper flats of Size 25x3mmshall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 50mm dia GI pipe shall be provided upto bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. |
| 263 | CPWD DSR (E&M 2022)5.14 Providing and Fixing 25mm X 5mm Copper strip on Surface or in recess for Connections etc. as required |
| 264 | Market Rate Supply and Laying of 4 Sq.mm 3 Core PVC Sheathed ,XLPE Insulated Multi Core Bright Annealed Bare Copper Conductor Heavy duty Armoured Industrial Cable For Voltage up to 1100 Volts as per the IS:694:1990 with supply and Installation of Suitable Cable gland and suitable Copper Lug and End termination etc, that cable to be lay through PVC conduit 32 mm and supply of PVC pipe ,PVC Bend,PVC Clamp and installation of Clamp and accsoriesincluded etc. |
| 265 | Market RateSupply Installation and Commissioning of 5 HP Wall Mounted DOL for 5HP ,3 phase 415Volt,50Hz MotorStarter with Analog Voltmeter,Analog Ammeter,Insulated Material push bottons,Indication Lampswith Suitable ORL relay and suitable Contactors including the Wall mounting arrangements and Earthing Connectionsand End Termination work included from Existing Panel Switch FN 32A to Starter and Starter to Motor with available cablesin Motor with Supply of Suitable Cable Lugs and cable Gland also included and etc as required (Motor To Starter Cable Supply Not in the Scope) |
| 266 | Market Rate Supply and Laying of 4 Sq.mm 3 Core PVC Sheathed ,XLPE Insulated Multi Core Bright Annealed Bare Copper Conductor Heavy duty Armoured Industrial Cable For Voltage up to 1100 Volts as per the IS:694:1990 with supply and Installation of Suitable Cable gland and suitable Copper Lug and End termination etc, that cable to be lay through PVC conduit 32 mm and supply of PVC pipe ,PVC Bend,PVC Clamp and installation of Clamp and accsoriesincluded etc. |
| 267 | CPWD DSR (E&M 2022)7.1 Laying One number PVC insulated and PVc Sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,Protective covering and refilling the trench etc as required |
| 268 | CPWD DSR (E&M 2022)7.1.1 Upto 35 Sqmm |
| 269 | CPWD DSR (E&M 2022) 2.5 Suppling and Fixing of following Ways surface/recess Mounting Vertical Type 415V TPN MCB Distribution board of sheet steel, Dust Protected,Duly Powder painte,inclusive of 200A tinned Copper busbar,Common neutral link,Earth bar,din bar for mounting MCBs(But without MCBs and incomer) as required.(Note Vertical type MCB TPDB is normally used where 3 Phase Out lets are required) |
| 270 | CPWD DSR (E&M 2022) 2.5.28 Way (4+24),Double Door |
| 271 | CPWD DSR (E&M 2022) 2.14 Supply and Fixing following Rating ,double pole,(Single Phase and Neutral)240V residual current circuit breaker (RCCB) having a sensitive current 30mA in the Existing MCB DB complete with connections,testing and Comisssioning etc as required |
| 272 | CPWD DSR (E&M 2022) 2.14.1 25A |
| 273 | CPWD DSR(E&M 2022) 2.10Supply and Fixing 32A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 274 | CPWD DSR (E&M 2022) 2.10.4Tripple Pole and Neutral |
| 275 | CPWD DSR (E&M 2022) 2.10Supply and Fixing 6A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 276 | CPWD DSR(E&M 2022) 2.10 1 Single Pole |
| 277 | CPWD DSR (E&M 2022)1.7 Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 278 | CPWD DSR (E&M 2022)1.7.3 2X4 Sq.mm + 1X 4 sq.mm earth wire |
| 279 | CPWD DSR(E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 280 | CPWD DSR (E&M 2022)1.27.4 6 Module (200mm X75mm) |
| 281 | CPWD DSR (E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 282 | CPWD DSR (E&M 2022)1.24.3 15/16A Switch |
| 283 | CPWD DSR (E&M 2022)1.24.5 6 pin 15/16 A Socket outlet |
| 284 | CPWD DSR (E&M 2022)1.7 Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 285 | CPWD DSR (E&M 2022)1.7.3 2X4 Sq.mm + 1X 4 sq.mm earth wire |
| 286 | CPWD DSR (E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 287 | CPWD DSR(E&M 2022)1.27.4 6 Module (200mm X75mm) |
| 288 | CPWD DSR (E&M 2022)1.24 CPWD Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 289 | CPWD DSR (E&M 2022)1.24.5 6 pin 15/16 A Socket outlet |
| 290 | Market Rate 6 AModular MCB switch |
| 291 | CPWD DSR (E&M 2022)1.7 Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 292 | CPWD DSR(E&M 2022)1.7.2 2X2.5 Sq.mm + 1X 2.5 sq.mm earth wire |
| 293 | CPWD DSR(E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 294 | CPWD DSR (E&M 2022)1.27.4 6 Module (200mm X75mm) |
| 295 | CPWD DSR (E&M 2022)1.10 Wiring for Light Point/Fan Point/Exhaust fan Point/call bell point with 1.5 Sqmm FRLS PVC Insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch ,Modular plate,Suitable GI box and Earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 296 | CPWD DSR (E&M 2022)1.10.3Group C |
| 297 | Market Rate Supply and Installation of the Street light 36W IP65 Cool White with Steel Bend Pipe with Suitable Clamp and any other arrangements required for Installation of Street Lightsin Existing Truss or wall or RCC Pillar |
| 298 | Market Rate Supply and Installation of the Street light 36W IP65 cool white with Steel Bend Pipe |
| 299 | CPWD DSR (E&M 2022) 2.5Suppling and Fixing of following Ways surface/recess Mounting Vertical Type 415V TPN MCB Distribution board of sheet steel, Dust Protected,Duly Powder painte,inclusive of 200A tinned Copper busbar,Common neutral link,Earth bar,din bar for mounting MCBs(But without MCBs and incomer) as required.(Note Vertical type MCB TPDB is normally used where 3 Phase Out lets are required) |
| 300 | CPWD DSR (E&M 2022) 2.5.28 Way (4+24),Double Door |
| 301 | Market Rate Supply and Fixing 63A Polerating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required (Mark ISI) Make: Legrand/Schneider/L&T/Seimens |
| 302 | CPWD DSR (E&M 2022) 2.10Supply and Fixing 20A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 303 | CPWD DSR (E&M 2022) 2.10.3 Double Pole Pole |
| 304 | CPWD DSR (E&M 2022) 2.10Supply and Fixing 16A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 305 | CPWD DSR(E&M 2022) 2.10.1Single Pole |
| 306 | Market Rate Supply and Laying of 16 Sq.mm 4 Core PVC Sheathed ,XLPE Insulated Multi Core Bright Annealed Bare Copper Conductor Heavy duty Armoured Industrial Cable For Voltage up to 1100 Volts as per the IS:694:1990 with supply and Installation of Suitable Cable gland and suitable Copper Lug and End termination etc that cable to be lay through PVC conduit 32 mm and supply of PVC pipe ,PVC Bend,PVC Clamp and installation of Clamp and accsoriesincluded etc. |
| 307 | CPWD DSR(E&M 2022)7.1.1 Laying One number PVC insulated and PVc Sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,Protective covering and refilling the trench etc as required |
| 308 | CPWD DSR (E&M 2022)7.1.1 Upto 35 Sqmm |
| 309 | CPWD DSR (E&M 2022)7.1. Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 310 | CPWD DSR (E&M 2022)7.1.3 2X4 Sq.mm + 1X 4 sq.mm earth wire |
| 311 | CPWD DSR (E&M 2022) 1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 312 | CPWD DSR (E&M 2022) 1.27.4 6 Module (200mm X75mm) |
| 313 | CPWD DSR (E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 314 | CPWD DSR (E&M 2022)1.24.315/16A Switch |
| 315 | CPWD DSR (E&M 2022)1.24.5 6 pin 15/16 A Socket outlet |
| 316 | CPWD DSR (E&M 2022)7.1. Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 317 | CPWD DSR (E&M 2022)7.1.2 2X2.5 Sq.mm + 1X 2.5 sq.mm earth wire |
| 318 | CPWD DSR (E&M 2022)1.10 Wiring for Light Point/Fan Point/Exhaust fan Point/call bell point with 1.5 Sqmm FRLS PVC Insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch ,Modular plate,Suitable GI box and Earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 319 | CPWD DSR(E&M 2022)1.10.3 Group C |
| 320 | CPWD DSR(E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 321 | CPWD DSR (E&M 2022)1.27.46 Module (200mm X75mm) |
| 322 | CPWD DSR (E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 323 | CPWD DSR(E&M 2022)1.24.1 5/6 A switch |
| 324 | CPWD DSR (E&M 2022)7.1 Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 325 | CPWD DSR (E&M 2022)7.1.2 2X2.5 Sq.mm + 1X 2.5 sq.mm earth wire |
| 326 | CPWD DSR (E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 327 | CPWD DSR(E&M 2022)1.27.4 6 Module (200mm X75mm) |
| 328 | CPWD DSR (E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 329 | CPWD DSR (E&M 2022)1.24.1 5/6 A switch |
| 330 | CPWD DSR (E&M 2022)7.1. Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 331 | CPWD DSR (E&M 2022)7.1.3 2X4 Sq.mm + 1X 4 sq.mm earth wire |
| 332 | CPWD DSR (E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 333 | CPWD DSR (E&M 2022)1.24.3 15/16A Switch |
| 334 | CPWD DSR (E&M 2022)1.24.5 6 pin 15/16 A Socket outlet |
| 335 | CPWD DSR (E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 336 | CPWD DSR (E&M 2022)1.27.4 6 Module (200mm X75mm) |
| 337 | CPWD DSR (E&M 2022)1.10 Wiring for Light Point/Fan Point/Exhaust fan Point/call bell point with 1.5 Sqmm FRLS PVC Insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch ,Modular plate,Suitable GI box and Earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 338 | CPWD DSR(E&M 2022)1.10.3 Group C |
| 339 | Market Rate Supply and Installation and Comissioning of LED Tube light 34/36 WColour Temperature 6500K Cool day light,Luminous flux 2100 lm 140 -270 Volt AC 50 Hz IP 65 Batten Material Polycorbonate 4 feet Type and Clamp fixing acceesoriesincludedIndoor Indusrial Application |
| 340 | Market Rate Supply and Fixing ofA.C Exhaust Fan 150mmSweep (Light Duty) complete with necessary wall opening and making good of the wall or window and Installation Fittings and Accessories and etc as required |
| 341 | Market Rate Supply and Laying of 4 Sq.mm 3 Core PVC Sheathed ,XLPE Insulated Multi Core Bright Annealed Bare Copper Conductor Heavy duty Armoured Industrial Cable For Voltage up to 1100 Volts as per the IS:694:1990 with supply and Installation of Suitable Cable gland and suitable Copper Lug and End termination etc, that cable to be lay through PVC conduit 32 mm and supply of PVC pipe ,PVC Bend,PVC Clamp and installation of Clamp and accsoriesincluded etc. |
| 342 | CPWD DSR(E&M 2022)7.1. Laying One number PVC insulated and PVc Sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,Protective covering and refilling the trench etc as required |
| 343 | CPWD DSR (E&M 2022)7.1.1 Upto 35 Sqmm |
| 344 | CPWD DSR (E&M 2022) 2.5.2Suppling and Fixing of following Ways surface/recess Mounting Vertical Type 415V TPN MCB Distribution board of sheet steel, Dust Protected,Duly Powder painte,inclusive of 200A tinned Copper busbar,Common neutral link,Earth bar,din bar for mounting MCBs(But without MCBs and incomer) as required.(Note Vertical type MCB TPDB is normally used where 3 Phase Out lets are required) |
| 345 | CPWD DSR(E&M 2022) 2.5.2 8 Way (4+24),Double Door |
| 346 | CPWD DSR (E&M 2022) 2.14 Supply and Fixing following Rating, double pole,(Single Phase and Neutral)240V residual current circuit breaker (RCCB) having a sensitive current 30mA in the Existing MCB DB complete with connections,testing and Comisssioning etc as required |
| 347 | CPWD DSR (E&M 2022) 2.14.1 25A |
| 348 | CPWD DSR (E&M 2022) 2.10Supply and Fixing 32A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 349 | CPWD DSR (E&M 2022) 2.10.4Tripple Pole and Neutral |
| 350 | CPWD DSR(E&M 2022) 2.10Supply and Fixing 6A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 351 | CPWD DSR (E&M 2022) 2.10.1 Single Pole |
| 352 | Market Rate Supply of 3 mtr long 50 mm dia G.I pipe with flat buried in ground with back filling compound in an earth pit mixed with sand in alternate layers of 150mm each up to a height of 2550mm from bottom. The pipe shall have provision for connecting earth flats / wires. Including accessories and Providing masonry Enclosure with cover plate |
| 353 | Market Rate Supply of earth plate of size 600 x 600 x 3mm copper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each upto a height of 3000mm from bottom. Two copper flats of Size 25x3mmshall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 50mm dia GI pipe shall be provided upto bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. |
| 354 | CPWD DSR (E&M 2022)5.14 Providing and Fixing 25mm X 5mm Copper strip on Surface or in recess for Connections etc. as required |
| 355 | CPWD DSR (E&M 2022)7.1. Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 356 | CPWD DSR (E&M 2022)7.1.3 2X4 Sq.mm + 1X 4 sq.mm earth wire |
| 357 | CPWD DSR (E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 358 | CPWD DSR (E&M 2022)1.27.4 1 Module (75 mm X75mm) |
| 359 | CPWD DSR (E&M 2022)1.27.1 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 360 | 2 Module (75 mm X75mm) |
| 361 | CPWD DSR(E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 362 | CPWD DSR (E&M 2022)1.24.3 15/16A Switch |
| 363 | CPWD DSR (E&M 2022)1.24.5 Modular MCB 16A |
| 364 | Market Rate Supply ,Installation,Commissioning of Split type Air Conditioner wall Mounted Indoor Unit with 2 TON Capacity Non Inverter 230V ,50HZ with With Remote control,AC out door stand ,Indoor mounting frame,required copper pipe and Drain pipe with PVC Drain Pipe Installation and Indoor Plug Top |
| 365 | CPWD DSR (E&M 2022) 2.5 Suppling and Fixing of following Ways surface/recess Mounting Vertical Type 415V TPN MCB Distribution board of sheet steel, Dust Protected,Duly Powder painte,inclusive of 200A tinned Copper busbar,Common neutral link,Earth bar,din bar for mounting MCBs(But without MCBs and incomer) as required.(Note Vertical type MCB TPDB is normally used where 3 Phase Out lets are required) |
| 366 | CPWD DSR (E&M 2022) 2.5.2 8 Way (4+24),Double Door |
| 367 | Market Rate Supply and Fixing 63A Polerating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 368 | CPWD DSR (E&M 2022) 2.10Supply and Fixing 20A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 369 | CPWD DSR (E&M 2022) 2.10.3Double Pole |
| 370 | CPWD DSR (E&M 2022) 2.10Supply and Fixing 16A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 371 | CPWD DSR (E&M 2022) 2.10.1Single Pole |
| 372 | Market Rate Supply and Laying of 4 Sq.mm 4 Core PVC Sheathed ,XLPE Insulated Multi Core Bright Annealed Bare Copper Conductor Heavy duty Armoured Industrial Cable For Voltage up to 1100 Volts as per the IS:694:1990 with supply and Installation of Suitable Cable gland and suitable Copper Lug and End termination etc that cable to be lay through PVC conduit 32 mm and supply of PVC pipe ,PVC Bend,PVC Clamp and installation of Clamp and accsoriesincluded etc. |
| 373 | CPWD DSR (E&M 2022)7.1. Laying One number PVC insulated and PVc Sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,Protective covering and refilling the trench etc as required |
| 374 | CPWD DSR (E&M 2022)7.1. 1 Upto 35 Sqmm |
| 375 | Market Rate Supply and Laying of 4 Sq.mm 3 Core PVC Sheathed ,XLPE Insulated Multi Core Bright Annealed Bare Copper Conductor Heavy duty Armoured Industrial Cable For Voltage up to 1100 Volts as per the IS:694:1990 with supply and Installation of Suitable Cable gland and suitable Copper Lug and End termination etc, that cable to be lay through PVC conduit 32 mm and supply of PVC pipe ,PVC Bend,PVC Clamp and installation of Clamp and accsoriesincluded etc. |
| 376 | CPWD DSR (E&M 2022)7.1. Laying One number PVC insulated and PVc Sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation,sand cushioning,Protective covering and refilling the trench etc as required |
| 377 | CPWD DSR (E&M 2022)7.1.1 Upto 35 Sqmm |
| 378 | CPWD DSR (E&M 2022) 2.5 Suppling and Fixing of following Ways surface/recess Mounting Vertical Type 415V TPN MCB Distribution board of sheet steel, Dust Protected,Duly Powder painte,inclusive of 200A tinned Copper busbar,Common neutral link,Earth bar,din bar for mounting MCBs(But without MCBs and incomer) as required.(Note Vertical type MCB TPDB is normally used where 3 Phase Out lets are required) |
| 379 | CPWD DSR (E&M 2022) 2.5.2.28 Way (4+24),Double Door |
| 380 | CPWD DSR (E&M 2022) 2.14 Supply and Fixing following Rating ,double pole,(Single Phase and Neutral)240V residual current circuit breaker (RCCB) having a sensitive current 30mA in the Existing MCB DB complete with connections,testing and Comisssioning etc as required |
| 381 | CPWD DSR (E&M 2022) 2.14.1 25A |
| 382 | CPWD DSR(E&M 2022) 2.10Supply and Fixing 32A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 383 | CPWD DSR (E&M 2022) 2.10 .4 Tripple Pole and Neutral |
| 384 | CPWD DSR (E&M 2022) 2.10Supply and Fixing 6A rating 240/415V,10 kA, \"C\" curve,miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and comissioning etc. as required |
| 385 | CPWD DSR (E&M 2022) 2.10.1 Single Pole |
| 386 | CPWD DSR (E&M 2022)7.1. Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 387 | CPWD DSR (E&M 2022)7.1.2 2X2.5 Sq.mm + 1X 2.5 sq.mm earth wire |
| 388 | CPWD DSR (E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 389 | CPWD DSR (E&M 2022)1.27.23 Module (75 mm X75mm) |
| 390 | CPWD DSR (E&M 2022)1.27Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 391 | CPWD DSR (E&M 2022) 1.27.5 8 Module (200mm X75mm) |
| 392 | CPWD DSR(E&M 2022)1.7 Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 393 | CPWD DSR (E&M 2022)1.7.3 2X4 Sq.mm + 1X 4 sq.mm earth wire |
| 394 | CPWD DSR(E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 395 | CPWD DSR (E&M 2022)1.27.4 6 Module (200mm X75mm) |
| 396 | CPWD DSR (E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 397 | CPWD DSR (E&M 2022)1.24.3 15/16A Switch |
| 398 | CPWD DSR(E&M 2022)1.24.56 pin 15/16 A Socket outlet |
| 399 | CPWD DSR(E&M 2022)1.26 Supply and Fixing modular blanking plate on the existing modular Plate & Switch Box excluding Modular Plate as required |
| 400 | CPWD DSR (E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 401 | CPWD DSR (E&M 2022)1.24.1 5/6 A switch |
| 402 | CPWD DSR (E&M 2022)1.10 Wiring for Light Point/Fan Point/Exhaust fan Point/call bell point with 1.5 Sqmm FRLS PVC Insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch ,Modular plate,Suitable GI box and Earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 403 | CPWD DSR (E&M 2022)1.10.3 Group C |
| 404 | Market Rate Supply and Installation and Comissioning of LED 15W Recessed Round Light fixing acceesoriesincluded (Make Philips,Crompton,Syska) Indoor Indusrial Application |
| 405 | Market Rate Supply and Installation and Comissioning of LED Tube light 34/36 WColour Temperature 6500K Cool day light,Luminous flux 2100 lm 140 -270 Volt AC 50 Hz IP 65 Batten Material Polycorbonate 4 feet Type and Clamp fixing acceesoriesincluded (Make Philips,Crompton,Syska) Indoor Indusrial Application |
| 406 | CPWD DSR(E&M 2022)7.1. Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 407 | CPWD DSR(E&M 2022)7.1.3 2X4 Sq.mm + 1X 4 sq.mm earth wire |
| 408 | CPWD DSR (E&M 2022)7.1. Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 409 | CPWD DSR (E&M 2022)7.1.2 2X2.5 Sq.mm + 1X 2.5 sq.mm earth wire |
| 410 | CPWD DSR(E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 411 | CPWD DSR(E&M 2022)1.27.2 3 Module (100mm X75mm) |
| 412 | CPWD DSR (E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 413 | CPWD DSR (E&M 2022)1.24.1 5/6 A switch |
| 414 | CPWD DSR (E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 415 | CPWD DSR (E&M 2022)1.24.3 15/16A Switch |
| 416 | CPWD DSR (E&M 2022)1.26 Supply and Fixing modular blanking plate on the existing modular Plate & Switch Box excluding Modular Plate as required |
| 417 | CPWD DSR (E&M 2022)1.10 Wiring for Light Point/Fan Point/Exhaust fan Point/call bell point with 1.5 Sqmm FRLS PVC Insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch ,Modular plate,Suitable GI box and Earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 418 | CPWD DSR(E&M 2022)1.10.3 Group C |
| 419 | Market Rate Supply and Fixing ofA.C Exhaust Fan 150mmSweep (Light Duty) complete with necessary wall opening and making good of the wall or window and Installation Fittings and Accessories and etc as required |
| 420 | Market Rate Supply of 3 mtr long 50 mm dia G.I pipe with flat buried in ground with back filling compound in an earth pit mixed with sand in alternate layers of 150mm each up to a height of 2550mm from bottom. The pipe shall have provision for connecting earth flats / wires. Including accessories and Providing masonry Enclosure with cover plate |
| 421 | Market Rate Supply of earth plate of size 600 x 600 x 3mm copper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each upto a height of 3000mm from bottom. Two copper flats of Size 25x3mmshall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 50mm dia GI pipe shall be provided upto bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. |
| 422 | CPWD DSR (E&M 2022)5.14 Providing and Fixing 25mm X 5mm Copper strip on Surface or in recess for Connections etc. as required |
| 423 | CPWD DSR (E&M 2022)7.1. Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 424 | CPWD DSR(E&M 2022)7.1.3 2X4 Sq.mm + 1X 4 sq.mm earth wire |
| 425 | CPWD DSR (E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 426 | CPWD DSR(E&M 2022)1.27.4 1 Module (75mm X75mm) |
| 427 | CPWD DSR (E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 428 | CPWD DSR (E&M 2022)1.27.1 2 Module (75mm X75mm) |
| 429 | CPWD DSR(E&M 2022)1.24 Supplying and Fixing following Modular Switch/Socket on the existing modular plate & Switch Box including connections but excluding modular plate etc. as required |
| 430 | CPWD DSR(E&M 2022)1.24.3 16A Modular MCB |
| 431 | CPWD DSR(E&M 2022)1.24.5 6 pin 15/16 A Socket outlet |
| 432 | Market Rate Supply ,Installation,Commissioning of Split type Air Conditioner wall Mounted Indoor Unit with 1.8/2 TON Capacity Non Inverter 230V ,50HZ with With Remote control,AC out door stand ,Indoor mounting frame,required copper pipe and Drain pipe with PVC Drain Pipe Installation and Indoor Plug Top |
| 433 | Market Rate Supply ,Installation,Commissioning of Split type Air Conditioner wall Mounted Indoor Unit with 1.8/2 TON Capacity Non Inverter 230V ,50HZ with With Remote control,AC out door stand ,Indoor mounting frame,required copper pipe and Drain pipe with PVC Drain Pipe Installation and Indoor Plug Top |
| 434 | CPWD DSR (E&M 2022) 19.1Supply and Installation, Commissioning of 1200mm Sweep BEE 5 Star Celing Fanwith brush less Direct Current (BLDC) Motor Class of Insulation B Nos of Blades ,30cm Long Down Rod 2 Nos Canopies Shackle kit,Safety Rope,Cpeer winding power factor not less than 0.9 service value (CM/M/W) minimum 6.00 Air Delivery minimum 210 Cum/Min,350 RPM (Tolerance as per IS: 374-2019)THD less than 10% remeote or Electronic Regulator for speed control all remaining acessories including Safety Pin,Nut Bolts,Washers,Temperature rise=75 deg C (Max) Insulation resistance more than 2 Mega ohm suitable for 230V,50HZ single phase AC Supply eartning etc,Complete as required |
| 435 | CPWD DSR(E&M 2022)7.1. Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 436 | CPWD DSR (E&M 2022)7.1.2 2X2.5 Sq.mm + 1X 2.5 sq.mm earth wire |
| 437 | CPWD DSR(E&M 2022)1.10 Wiring for Light Point/Fan Point/Exhaust fan Point/call bell point with 1.5 Sqmm FRLS PVC Insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch ,Modular plate,Suitable GI box and Earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 438 | CPWD DSR(E&M 2022)1.10.3 Group C |
| 439 | CPWD DSR (E&M 2022) 19.1Supply and Installation, Commissioning of 1200mm Sweep BEE 5 Star Celing Fanwith brush less Direct Current (BLDC) Motor Class of Insulation B Nos of Blades ,30cm Long Down Rod 2 Nos Canopies Shackle kit,Safety Rope,Cpeer winding power factor not less than 0.9 service value (CM/M/W) minimum 6.00 Air Delivery minimum 210 Cum/Min,350 RPM (Tolerance as per IS: 374-2019)THD less than 10% remeote or Electronic Regulator for speed control all remaining acessories including Safety Pin,Nut Bolts,Washers,Temperature rise=75 deg C (Max) Insulation resistance more than 2 Mega ohm suitable for 230V,50HZ single phase AC Supply eartning etc,Complete as required |
| 440 | CPWD DSR (E&M 2022)7.1. Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 441 | CPWD DSR (E&M 2022)7.1.2 2X2.5 Sq.mm + 1X 2.5 sq.mm earth wire |
| 442 | CPWD DSR (E&M 2022)1.10 Wiring for Light Point/Fan Point/Exhaust fan Point/call bell point with 1.5 Sqmm FRLS PVC Insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch ,Modular plate,Suitable GI box and Earthing the point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 443 | CPWD DSR (E&M 2022)1.10.3 Group C |
| 444 | CPWD DSR (E&M 2022)1.27 Supplying and fixing following size/modules,GI box alongwith modular base & Cover plate for modular switches in recess etc. as required |
| 445 | CPWD DSR (E&M 2022)1.27.4 6 Module (200mm X75mm) |
| 446 | Market Rate Supply of UPS Input 230V,AC,50/60 Hz,4.5A,1 pase,Output voltage :230V,Ac,50/60 Hz,2.9A,1Phase,DC voltage:12V,39.4A,Capacity:650VA/630W |
| 447 | Market Rate Supply and Laying of 6 Sq.mm 4 Core PVC Sheathed ,XLPE Insulated Multi Core Bright Annealed Bare Copper Conductor Heavy duty Armoured Industrial Cable For Voltage up to 1100 Volts as per the IS:694:1990 with supply and Installation of Suitable Cable gland and suitable Copper Lug and End termination etc that cable to be lay through PVC conduit 32 mm and supply of PVC pipe ,PVC Bend,PVC Clamp and installation of Clamp and accsoriesincluded etc. |
| 448 | CPWD DSR(E&M 2022)7.1. Wiring for Circuit/Submain wiring along with earth wire with the following sizes of FRLS PVC insulated Copper conductor,Single core cable in Surface/recessed steel conduit as required |
| 449 | CPWD DSR (E&M 2022)7.1.3 2X4 Sq.mm + 1X 4 sq.mm earth wire |
| 450 | Market Rate Supply and Installation of BEE 5 Star Rating for superior energy efficiency. with CFC-free PUF insulation for maximizing heat retention,Pebble Shine DG Storage Water Heaters come with an user-friendly temperature display and adjustable temperature control knob,Built-in safety shock module offers comprehensive protection against electric shock,Rust-proof ABS Body Model for enhanced durability,Titanium enriched vitreous enamel coating used in the inner tank for higher corrosion resistance,Superior Incoloy 800 heating element for sustained heating performance & sacrificial magnesium anode rod for extended lifespan,Suitable for high-rise buildings & hard water usage,Multi layered safety features for complete peace of mind,Warranty of 2 Year on Product; 4 Year on Heating Element; 7 Year on Inner Tank |
| 451 | EQUIPMENT AND MACHINERY |
| 452 | Centrifugal Pumps for Sea water Intake |
| 453 | Market Rate Supply, Installation and Commissioning of Centrifugal Pumps for Sea Water Operation Pump,Type: Horizontal End Suction Single Stage Centrifugal Pump, Flow/Delivery (Q):80 m3/hr, Head: 20 Meter, Power: 10HP ,Suction Pressure : Flooded,NPSH(m) Required: 0.9Meter Casing: Volute, Seal: Mechanical Seal, Working Fluid: Sea water, Specific Gravity of Working Fluid (Sea Water) :1.025,RPM:1400-1500,Pump Casing MOC: Duplex Steel, Casing Cover: Duplex SteelPump Impeller MOC: Duplex Steel ,Impeller Type : Closed Impeller ShaftMOC: SS329L,Sleeve MOC:SS329L,Mechanical seal fluid contact Parts MOC: SS329L,Standatds:EN 22858,ISO 2858,DIN 24256,Oil Lubrication, Breather, Filling Plug on Top, Oil Sight Glass, Constant Oil Leveler, Accessories comprising with MS with Hot Dip Galvanizing, Base Frame MOC: Hot Dip Galvanized, Coupling, Coupling Guard, GI Foundation Bolts, Motor Specification: Motor Power :10 HP,RPM:1400-1500,Volt:415V,Frequency:50Hz,Phase-3 , Motor Coil: Copper,IP-65,IE3,Motor Body MOC : Iron Alloy /CI, Ambient temp: 50 Deg cel |
| 454 | Market Rate Supply, Installation and Commissioning of Centrifugal Pumps for Sea Water Operation,Type: Horizontal End Suction Single Stage Centrifugal Pump, Flow/Delivery (Q):80 m3/hr, Head: 20 Meter, Suction: Negative Suction, Suction Lift: 2.5 (From Tank Bottom to Impeller Eye: 2.5Meter) Meter Casing: Volute, Seal: Mechanical Seal,Working Fluid: Sea water, Specific Gravity of Working Fluid /Sea Water:1.025,Power : 10 HP,RPM:1400-1500,Pump Casing MOC: Duplex Steel, Casing Cover: Duplex SteelPump Impeller MOC: Duplex Steel ,Impeller Type : Closed Impeller ShaftMOC: SS329L,Sleeve MOC:SS329L,Mechanical seal fluid contact Parts MOC: SS329L,Standatds:EN 22858,ISO 2858,DIN 24256,Oil Lubrication, Breather, Filling Plug on Top, Oil Sight Glass, Constant Oil Leveler, Accessories comprising with MS with Hot Dip Galvanizing, Base Frame MOC: Hot Dip Galvanized, Coupling, Coupling Guard, GI Foundation Bolts, Motor Specification: Motor Power :10 HP,RPM: 1450,Volt:415V,Frequency:50Hz,Phase-3 , Motor Coil: Copper,IP-65,IE3,Motor Body MOC : Iron Alloy /CI, Ambient temp: 50 Deg cel,Design,Supply and Installation of Priming Pot with FRP MOC with Suction Lift :2.5 Meter with Proper Suitable Falange as per the Pump Suction Size |
| 455 | Market Rate Supply, Installation and Commissioning of Centrifugal Pumps with supply and Installation of suitable Priming Pot for Sea Water Operation Pump Specification:Type: Horizontal End Suction Single Stage Centrifugal Pump, Flow/Delivery (Q):100-150 m3/hr, Head: 25 Meter, NPSHR: 2.7 Meter, Suction: Negative, Casing: Volute, Seal: Mechanical Seal, Working Fluid: Sea water, Specific Gravity of Working Fluid /Sea Water:1.025,Power : 20HP RPM:1450,Mechanical seal fluid contact Parts MOC: SS329L,Standatds:EN 22858,ISO 2858,DIN 24256,Oil Lubrication, Breather, Filling Plug on Top, Oil Sight Glass, Constant Oil Leveler, Accessories comprising with MS with Hot Dip Galvanizing, Base Frame MOC: Hot Dip Galvanized, Coupling, Coupling Guard, GI Foundation Bolts,Motor Specification: Power:20HP,RPM:1450,Volt:415V,Frequency:50Hz,Phase-3 Motor Coil: Copper,IP-65,IE3,Motor Body MOC : Iron Alloy /CI, Ambient temp: 50 Deg cel Design,Supply Installation and Commissioning of Priming Pot Specification :FRP To be fix with Centrifugal Pump Suction Line Pump Capacity-200m3/hr,H-25M, Suction/Discharge: Suction Lift 4.5 Meter Priming Pot Connection Flanges Should be FRP/PVC which flange with size suitable size for the Pump Suction Working Fluid Sea Water and Supply and Installation of PVC Foot Valve in PVC suction Pipe and suitable PVC NRV in Pump Discharge ,Pump Casing MOC: Duplex Steel, Casing Cover: Duplex SteelPump Impeller MOC: Duplex Steel ,Impeller Type : Closed Impeller ShaftMOC: SS329L,Sleeve MOC:SS329L,Mechanical seal fluid contact Parts MOC: SS329L,Standatds:EN 22858,ISO 2858,DIN 24256,Oil Lubrication, Breather, Filling Plug on Top, Oil Sight Glass, Constant Oil Leveler, Accessories comprising with MS with Hot Dip Galvanizing, |
| 456 | Market RateSupply, Installation and Commissioning of Vaccum PumpPump Specification:Pump Type: Vaccum Pump,Power 3.7 KW(5 HP),Vacuum Maximum :635 mm Hg,Air Flow maximum:73.8 m3/hr,Suction Size :40 mm,Delivery Size:40 mm,Rated Voltage :415 V,Speed: 1450 RPM,Phase : 3 Phase,Frequency:50 Hz,No of stage :1,Impeller:Stainless Steel,Delivery Casing: Cast Iron,Motor Body: Cast Iron,Pump Shaft: Carbon Steel,Seal Gland Packing,Dimension:1080X625X610 MM;260 Kg |
| 457 | Air Blowers (Twin lobe positive displacement air blower) |
| 458 | Market Rate Twin lobe positive displacement air blower of capacity 450 M3/ hr@ 3 meter water depth complete set with Air blower, Electric motor 3 phase 440V AC 50 Hz, filtration module, V belt with tightening arrangement, NRV, pressure gauge, safety valve, suction discharge full pipe companion assembly with coupling of size minimum 75 to 90 mm, blower and motor pulley, suction silencer, base frame, foundation bolt with base frame, at least 3 meter additional pipe for heat loss. |
| 459 | Ozone Generator with Oxygen Concentrator |
| 460 | Market Rate Supply, Installation and Commissioning of Ozone Generator with Oxygen Concentrator with suitable capacity Circulation pump and Venturi Injectors, Flow Meter and Accessories with Air Cooling System Capacity:60 GPH,Oxygen Flow:10LPM,Oxygen Pressure:7PSI,Ozone Generation Principle: On corona discharge principle,Power consuption:600 Watt,O/P frequency:5-10 Khz,High Voltage O/P:36000V PP Volt,MOC: Wetted parts in Ozone compatible material and Outer Panel in Mild steel with Powder coated,O2 Inlet /O3 Out let :SS316,6mm Nozzle,Ozone O/P Control:20-100%,HT Transformer : Air Cooled,Way of Cooling: Air Cooling for internal and External Electrode,Dew Point:-45 degree C,Ambient Temp : Not Exceding 32 deg,Ozone Concentration:80-90 mg/L,Indication: Mains on LED/Ozone ON/Ozone current,Size: LXWXH:604X405X962 mm Weight:45 Kg ,Volt:230+/- 10%,Ac,50Hz,1 Phase,+5% supply with Earthing Oxygen Concentrator Specification:Electrical: 230V-50 Hz,Flow Delivery Rate:0 to 10LPM,Oxygen Concentration:93%+/- 3%,Power consuption 650 Watts,Operating Pressure(Mpa): 0.04-0.07,Filters:Cabinet,Compressor Intake & Bacteria,Battery:9Volt,Weight<28 Kg,Size: LXWXH:365X375X600 mm,Operating Environment: Ambient Temperature:(10Deg C to 40Deg C),Humidity: 15% to 95% Non-Condensing,Storage Range Temperature:(20Deg C to 6 Deg C),Humidity:15% to 95%,Non Condensing |
| 461 | Ozone Mixing Cone |
| 462 | Market Rate Supply, Installation and Commissioning of Ozone Mixing ConeDiameter: 0.9 Meter Height: 2.38 Meter Inlet/Outlet Size:150mm Liquid Flow:80 M3/hr Gas Port : Ozone Inlet Bush 3/4”X1/2” MOC:SS316 Pressure gauge Mounting Bush ¾”X1/2” MOC:SS316 |
| 463 | UV Sterilizer |
| 464 | Market Rate Supply, Installation and Commissioning of UV Sterilizer Pipe Size line Inlet and Outlet Water : 110mmWater Flow : 100m3/hr,Operting pressure(1-4 Kg/cm2),Operating Temperature:2-42 Deg C,Recommende ON/OFF cycle: <4/24 hrs,UV Dose:30MJ/cm2,Electrical:220V ,50Hz,Application: Sea Water Disinfection Purpose,UV system with suitable Control Panel,With Digital Hour Meter With Safety devices Included |
| 465 | Rapid Sand Filter |
| 466 | Market Rate Supply and Installation of Rapid Sand Filter Long Lasting non Corrosive UV resistance composites allow to resist extreme weather conditions for long life without corrossion top mount Rapid sand filter of diametr of 40\" inlet/Outlet 2 inch of of flow 39000 Litre/hr Spherical tank with uniform wall thickness (V 1000 dia -40\" Top mount Filter 2\" Valve 39000 Litres Features: Fibre glass reinforced tank with UV resistant surface finish,2.Internal surface of the tank is finished with water resistant resin,3.Spherical tank with uniform wall thickness or similar ,Sand filter with Glass media for Rapid sand filters of Size 6 to 8 mm ,Sand Filter with Multiport valve also in scope of supply |
| 467 | Solar Power Plant Capacity :30 KWp Expected Annual Production: 48,000 units |
| 468 | Market Rate Design, Supply, Installation and Commissioning of Grid Tied Solar Power System of 30 Kw in Ground Mounted GI Structure,Supply,Installation, Testing and commissioning of Solar Bidirectional Meter (Including Liasoning with EB Department for obtaining proper approvals (CEIG)), Power Plant Capacity: 30 KWp, Expected Annual Production: 48,000 units, Proposed PV (Photovoltaic) Module: MONOPERC HalfCut, Module rating: 550Wp, Number of modules: 54 No’s, Maximum PV array voltage: 1000 V, INVERTER Rating: 30 KW 3 Phase, No. Of Inverter: 1 No,Solar PanelsMONOPERC Halfcut (Qty-54 Nos) Capacity: 550 Wp,Warranty: 12 Years product warranty,25 Years Performance,Solar On Grid Inverter, Capacity: 30 kW 3 Phase, (Qty-1 Nos)Solar Mounting Structure, Capacity: 30 KW,(Qty-1 Set)DCDB , with SPD & Fuse,supplyInstallation and comissioning of Lightning Arrestor &Accessories Supply Installation comissioning of AC Earth Pit-Double Earth - 1meter Depth-17 mm dia chemical earth(Qty-2 Nos),Dc Earth Pit-Double Earth - 1meter Depth-17 mm dia ,chemical earth(Qty-2 Nos),chemical earth,Earth strip as required etc.Free Periodical maintenance visit will be done once in amonth for 10Years,Net metering application submission & getting Meter from EB will be done by contractor scope,Elctical DC Ac Connection In Power plant and Power plant to EB Main Panel Electical cable,Glands,Lugs,etc as required |
| 469 | Including liasoning with EB department for obtaining proper approvals(CEIG) Net metering application, submission and getting meter from EB will be contractor scope |
| 470 | SERVO Control Voltage Stablizer 150 KVA |
| 471 | Market Rate Supply, Installation and Commissioning of SERVO Control Voltage Stablizer Capcity 150 KVA Oil Cooled Industrial Model Input Voltage:295-465 V,Output:400V +/- 1% with Surge Protector,Bypass Switch,I/P MCB,O/P Contactor,Fiber Cable Wiring and End termination ,Over load protection,Short Circuit Trip,Time Delay controls,Phase reversal Protection,High Voltage Cut off,Low Voltage cut OFF,Torridly Wound Variable Auto Transformer,Drive: Direct AC Drive,Staandard: IS 9815,IS 5142,IS 302-1,Duty Cycle: Continous:24 Hrs,Class of insulation: E,Alarm: Low and high voltage,Single phase alarm,Phase reversal Alarm,LCD monitor to using to view Input/Out put Voltage and Current,Micro Controller base Programable Control circuit with all accesories etc. as required (Warranty:2 Years) |
| 472 | Supply,Installation Commissioning of DG with AMF Panel and Power Cables and Accsories Power Rating KVA:125 |
| 473 | Market Rate Supply,Installation Commissioning of DG with Power Rating KVA:125, No.of Phase and wire: 3 phase , 4 wire, Power Factor: 0.8 (lagging), Current: 174 A, RPM: 1500,MOEF Certified Power(HP):159,Required Power for Rated KVA (HP):158, Cooling: Liquid Cooled (EG Complete 50:50), No of Cylinder: 6-In line, Bore (mm) X Stork (mm): 102X120 , Compression Ratio:16.5:1, Displacement (Litre): 5.9, Fuel: Diesel, Fuel Consumption @75% Load with radiator and fan (Litre/hr):22.5, Fuel Consumption @100 % Load with radiator and fan (Litre/hr):30.25, Performance Class of Genset: ISO 8528-5 G2, Starting System: 24 V DC Electrical, Lube Oil Specification: CI4+ 15W40, Lube oil Sump Capacity high- Low level (litre):19.9-14.9, Total Lubrication system capacity (Litres):21.4, Total coolant Capacity (litres):26, Exhaust Pipe size(inch):4, Length X Width X Height (Engine) (mm):1066X725X1033, Mean piston Speed(m/s):6, Combustion Air Intake @100% Load (±5%) (cfm):311, Alternator Make: STAMFORD (CGT), Brushless Type, Screen Protected, Revolving Field, Self-Excited Alternator Confirming IS/IEC 60034-1, 3 Phase Reconnectable winding with 12 Terminals brought out for connectionSealed Bearings for longer life and lesser Maintenance, Enclosure: IP23, Voltage Regulation (Max): ±1%, Class of Insulation: H Class, Winding Pitch: 2/3, Stator Winding: Double Layer Lap, Rotor: Dynamically Balanced, Waveform distortion/ Total Harmonic Distortion: No Load <1.5% , Non distorting balanced Linier Load <5%, Maximum Unbalanced Load across Phases: Less than or Equal to 25 %,Inline Fuel pump with Mechanical governing, Battery: 1x12V DC Battery, Battery Charging Alternator, Standard integral set mounted radiator system, designed and tested for 50 Deg Celsius ambient temperature, Mounted on a Common MS Base Frame with AVM pads Base frame with Integral fuel Tank is provided with Drain Plug, Air vent and Outlet Connection, Level Indicator and Provision for cleaning, Control Panel: Control Panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather proof, Aluminium bus bars with suitable capacity with incoming and outgoing terminals, |
| 474 | Indicating Lamps for Load ON, And Set Running, Instrument Fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protection, Engine Metering, Oil Pressure, Coolant Temperature, Battery Voltage, Engine Speed, AC Alternator Metering: L-L Voltage and L-N voltage Current (Phase and Total) Amperes (Phase and Total) and Frequency, Engine protection: Low lube oil pressure, High/Low Coolant Temperature,Over Speed,Battery Over/Under /Weak Volts,Fail to Crank/Start,Sensor Failure,Low Coolant Level sensor, Temperature, Battery Over/Under /weak Volts, Fail to crank /Start, Sensor Failure, Cranking Lockout, Low fuel Level, AC Alternator Protection: Over/Under Voltage, Over/Under Frequency,Over Current,Short Circuit and Loss of AC Sensing, Data Logging: Engine Hours, Control Hours,Engine Starts and Up to 10 recent Fault codes, Configurable glow plug control ,12V DC Operation, Sleep Mode Modbus Interface, In power Compatible(PC based service tool), Acoustic Enclosure: Specially designed to meet Stringent MoEF /CPCB norms of 75 dBA @ 1 mtr at 75 % load and free field conditions, The acoustic Enclosure is made of CRCA sheets in Munsel green Shade and a Structural/Sheet Metal Base Frame, High Quality Noise absorbent and fire retardant grade acousticinsulation material (Rockwool)Complying to IS 8183, Base lifting for Easy Handling at Customer Site, Fluid drains for lube oil and Fuel, Fuel filling arrangement inside the |
| 475 | Enclosure, Conformance Standards: IS/IEC 60034-1, IS 1460, ISO 8528, ISO 3046, ISO 9001, IS 13018, Silencer: Hospital Grade Silencer Suitably Optimised to meet Stringent noise emission standards laid down by MoEF/CPCB Supply Installation Comissioning all End Termination of AMF Control Panel with Auto Change Over Mechanism with suitable Breaker: The control panel shall be fabricated out of 1.5 mm Thick sheet steel ,Totally enclosed dust, damp and vermin proof free standing floor mounted type & front operated. It shall be made into section such that as far as feaseable, there is no mixing of control power, DC & AC functions in the same section and they are sufficiently segregated exept where their bunching s necessary. Hinged doors shall be providepreferably double leaf for acess for routin inspection from the rear. The degree of protection required will be IP-42 confirming IS2147, Labeling: all internal components shall be given suitable identification lables shall be fixed on buttons,indication lamps etc, Painting : The entire panel shall be given primer coat after proper treatment and powder coating with 7 tank process before assembly of various items, Control system equipments and components such as relays, contactors,timers,etc. Both for automatic operation on main failure and as well as normal operation,Equipments and components necessary for testinggenerating set’s healthiess with test mode and with load on mains,Necessary instruments and Acessories such as voltmeter,powerfactor meter,KW meter,KWH meter,Ammeter,Frequency meteretc.in one energy analyzer unit with selector switch to obtain the reading of desired parameters,Necessary indication lamps,fuces,terminal box,Push butons,control Switches etc as required,Necessary Engine/ Generating set shut down devics due to faults/abnormalities,Necessary visual audio |
| 476 | alarm indication and annunciation facility as specified, Necessary Battery Charger Necessary excitation control and voltage regulation equipment.(Alternatively provide on the Alternator itself) Necessasry overhead bus trunking terminations all internal wiring. Connections etc. As required Mode Auto Mode,Manual Mode, DG Erection and Machinery For Erection: All tools and Tackels,Crane required for Unloading /Handling of Equipments and Materials at site,their assembly,Erection,Testing,Commissioning Shall be the responsibility of the Contractor Statutory Clearance (S): Approval /Clearance of the Complete installation shall be obtained by the contractor from CPCB/State Pollution Control Boards /Local Bodies/ Central Electricity Authority (CEA) other Licencing authorities when ever required. However, Application shall be made by Departmental and any Statutory fee,as Applicable,Shall be paid by Department directly to the Govt.authorities concerned. Supply and Installation ,End Termination ofPVC Sheathed ,XLPE Insulated 4 core 120 sqmm Armoured Alumnium cablePVC Sheathed ,XLPE Insulated (Cable length-50 meter approx)Cable laying and End termination from DG to AMF Panel and AMF Panel to 200A Change Over Switch supply Installation of On Load Changeover Switch Disconnectors (Manual) With SS Enclosure,415V,50Hz,4 Pole,Rated Operational Current-200A,Rated Insulation voltage 1000V and connection to be given as per the site requirements etc as required and also all cable with gland and Lugs ,Clamps ,clamping ,laying Excavation work and refilling with proper Conduit with safety measures |
| 477 | Market Rate supply Installation of On Load Changeover Switch Disconnectors (Manual) With SS Enclosure,415V,50Hz,4 Pole,Rated Operational Current-200A,Rated Insulation voltage 1000V |
| 478 | Catridge Filter |
| 479 | Market Rate Supply of Catridge FilterFilter Area Sq ft:200 Verical Clearance :76\",Filter Diameter:15.5 \",Flow Rate:34 m3/hr with Air relief valve,Lock ring,Esy to remove and Rinse,2\" Plumbing with Pressure Gauge and Filter Housing Fibreglass reinforced tank |
| 480 | Market Rate Supply of Deepfreezer 500Litre Horizontal Double Door 230V 50Hz |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy