| 1 | EARTH WORKS: |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | All Kinds of Soil |
| 4 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 5 | Supplying and filling in plinth with sandy soil under floors including watering, ramming, consolidating & dressing complete. |
| 6 | CEMENT CONCRETE WORKS: |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: |
| 8 | 1:4:8 (1 Cement:4 coarse sand:8 graded stone aggregate: 40 mm nominal size) |
| 9 | 1:5:10 (1 Cement:5 coarse sand:10 graded stone aggregate: 40 mm nominal size). |
| 10 | Providing & laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement: 2 coarsesand: 4 graded stone aggregate 20 mm nominal size) |
| 11 | R.C.C.WORKS: |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level |
| 13 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 14 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 15 | 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 16 | R.C.C. work in beams, suspended floors, roofs having slope uptp 15o landings, balconies, shelves, chajjas,lintels, band, plain window sills, staircases and spiral staircases above plinth level upto floor fivelevel excluding the cost of centering, shuttering, finishing and reinforcement, with 1 : 1 .5: 3 (1 cement :1.5 coarse sand :3 graded stone aggregate 20 mm nominal size) |
| 17 | Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 18 | Thermo-Mechanically Treated bars |
| 19 | Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete. Above Plinth Level. |
| 20 | Thermo-Mechanically Treated bars |
| 21 | FORM WORKS: |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 23 | Foundations, footings, bases of columns, etc. for mass concrete |
| 24 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 25 | Suspended floors, roofs, andings, balconies and access platform with water proof ply 12 mm thick. |
| 26 | Columns, pillars, piers, abutments, posts and struts. |
| 27 | Stairs, (excluding landings) except spiral staircases. |
| 28 | BRICK WORKS: |
| 29 | Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: |
| 30 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 31 | Half brick masonry 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in |
| 32 | Cement mortar 1: 3 ( 1 cement: 3 coarse sand ) |
| 33 | Extra for half brick masonry in superstructure, above Floor V level for every four floors or part thereof by mechanical means by lifting materials using mobile crane |
| 34 | WOOD WORKS |
| 35 | Providing wood works in frames of doors, windows, clerestory windows & other frames, wrought frameed & fixed in position with hold fast lugs or dash fastener shall be paid for separately: |
| 36 | Local best quality teakwood |
| 37 | Providnig and fixing panelled or panalled and glazed shutters for foors, windows and celestory windows including ISI marked M.S. butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all completely asd per direction of Engineer-in-charge. |
| 38 | Local best quality teakwood |
| 39 | 35mm thick shutters |
| 40 | Providing & fixing M.S. Grills of required pattern in frames of windows etc. With M.S. Flats, square or round bars etc. Including priming coat with approved steel primers all complete. |
| 41 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 42 | Providing & fixing bright finished bars 100 mm door mortice latch with one dead bolt & a pair of levers handles with necessary screws etc. complete (Best make of approved quality) |
| 43 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : |
| 44 | 300x16x5mm |
| 45 | Providing & fixing bright finished brass Tower bolts (barrel type) with necessary screws etc. complete. |
| 46 | 250x10 mm |
| 47 | Providing and fixing chromium plated brass handles with necessary screws etc. complete: |
| 48 | 125 mm |
| 49 | FLOORING: |
| 50 | Providing and laying Vitrified tiles in floor in diffe rent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.080/0 and conforming to 19.15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will bo done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 51 | Double charge vitrified tile polished finish of size - Size of Tile 600 x 600 mm |
| 52 | Providing and fixing 1st quality ceramic glazed wall tiles conformingto IS : 15622 (thickness to be specified by the manufacture of approved make in alt colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (I cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 53 | Marble stone flooring with 18mm thick marble stone (sample Of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with |
| 54 | Makrana White second quality |
| 55 | Tile work in skirting, risers of steps and dado (upto 2 m height) over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shadecomplete |
| 56 | Marble tiles(polished) Raj Nagar |
| 57 | 8 mm thick |
| 58 | ALUMINIUM WINDOWS |
| 59 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required EPDM rubber/ Neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steelscrews, all complete as per architectural drawings and the directions Of Engineer-incharge. (Glazing and panelling to be paid for separately): |
| 60 | For fixed portion. |
| 61 | Anodised aluminium (anodised transparent or dyed to required kg940.50 shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 62 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 63 | Anodised aluminium (anodised transparent or dyed to required kg Rss 1.03280 shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 64 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 65 | With float glass panes of 5.50 mm thickness |
| 66 | FINISHING: |
| 67 | 12 mm cement plaster of mix 1:4 (1 cement:4 coarse sand). |
| 68 | (1 cement:4 coarse sand) |
| 69 | 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement:4 coarse sand). |
| 70 | 1:4 (1 cement:4 coarse sand). |
| 71 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. |
| 72 | New work(two or more coats)over and including priming coat with cement primer |
| 73 | Finishing walls with textured exterior paint of required shade: |
| 74 | New Work(two or more coats applied @3.28ltr/10 Sqm)over and including base coat of water proofing cement paint [email protected]/10 sqm. |
| 75 | Applying priming coat:- |
| 76 | With ready mix pink or grey primer of approved brand and manufacture on wood work(hard and soft wood) |
| 77 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth |
| 78 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 79 | Two or more coats on new work |
| 80 | STEEL WORK |
| 81 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffinge polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 82 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 83 | Electric resistance or induction butt welded tubes |
| 84 | Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of25x25xO.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.l. channels 45x15xO.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular to Gil. intermediate channel with connecting clips made out of 2.64mm diax230mm long C.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/pattition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishng to a flush finish of tapered and square edges of the board with recommended jointing compound,jointing tapes, finishing with jointing compund in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board,all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed. all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with |
| 85 | 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095 - Part 1 |
| 86 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineerin-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using selt drilling Iself tapping screws ot size (5.5x 55 mm) with EPDM seal,comptete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with |
| 87 | Precoated galvanised iron profile sheets 0.50 mm thick |
| 88 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or C.I. seam bolts and nuts, G.l. plain and bitumen washers complete |
| 89 | Ridges plain (500 - 600mm). |
| 90 | MISCELLANEOUS |
| 91 | Dismantling steel work manually/ by mechanical means in built up sections without embering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 92 | Extra for dismantling trusses, rafters, purlins etc. of steel work forevery additional span of one metre or part thereof beyond 10 metres metre span |
| 93 | Dismantling rooting including ridges, hips, valleys and gutters etc. and stacking the material within 50 metres lead of: |
| 94 | G.S. Sheet |
| 95 | Design,Installation,testing and commissioning of SS 10 Passenger Lift(680 KGS) Machine. |
| 96 | SANITARY INSTALLATION |
| 97 | EARTH WORKS: |
| 98 | Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m. including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 99 | All Kinds of Soil |
| 100 | Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 101 | CEMENT CONCRETE WORKS: |
| 102 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: |
| 103 | 1:3:6 ( 1 Cement.: 3 coarse sand 6 graded stone aggregate 40 mm nominal size) |
| 104 | 1:4:8 ( 1 Cement: 4 coarse sand 8 graded stone aggregate 40 mm nominal size) |
| 105 | FORM WORKS: |
| 106 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 107 | Foundations, footings, bases of columns, etc. for mass concrete |
| 108 | Suspended floors, roofs, landings, balconies and access |
| 109 | RCC WORKS: |
| 110 | Reinforced cement concrete work in beams, suspended floors, roofs having stope upto 15landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 111 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. |
| 112 | Thermo-Mechanically Treated bars |
| 113 | PRE-CAST: |
| 114 | Providing, hoisting and fixing upto floor five lovol procast reinforced comont concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the tike including tho cost 01 required contoring, shuttering but excluding cost of reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand: 3graded stone aggregate 20mm nominal size). |
| 115 | BRICK WORKS: |
| 116 | Brick work with 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in: cum |
| 117 | Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 118 | Half brick masonry 1st class common burnt clay F.P.S. (non modular) bricks in superstructure above plinth level upto floor V level in |
| 119 | Cement mortar 1: 3 ( 1 cement: 3 coarse sand ) |
| 120 | Honey-comb brick work 10/11.4 cm thick with 1st class common burnt clay FP.S. (non modular) bricks in superstructure above plinth level and upto floor V level in cement mortar 1 : 4 ( 1 cement : 4 coarse sand) |
| 121 | FLOORING: |
| 122 | Cement concrete flooring 1:2:4 (I cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost Of nosing of steps etc. complete. |
| 123 | 40mm thick with 20mm nominal size stone aggregate. |
| 124 | Cement plaster skirting (upto 30 cm height) with cement mortar 1:3 (I cement : 3coarse sand) finished with a floating coat of neat cement |
| 125 | 18 mm thick |
| 126 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap. 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handlo lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: |
| 127 | White Vitreous china Orissa pattern W.C. pan of size 580 x 440mm with integral type foot rests |
| 128 | Providing and fixing white vitreous china pedestal for wash basin eaccompletely recessed at the back for the reception of pipes and fittings |
| 129 | Providing and fixing P.V.C. tor sink or wash basin including P.V.C. waste fittings complete. |
| 130 | Flexible pipe |
| 131 | 32 mm dia |
| 132 | Providing and fixing 600x450 mm beveled edge mirror of superiorglass (Of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass scrows and washers complete. |
| 133 | Providing and fixing PTMT liquid soap container 109 mm wide, 125each 195.80 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 134 | Providing and fixing PTMT urinal cock of approved quality and colour. |
| 135 | 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms. |
| 136 | Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fitting with solvent cement, tenching, refilling & testing of joints complete as per direction of Engineer in charge |
| 137 | 75 mm dia |
| 138 | 110 mm dia |
| 139 | WATER SUPPLY: |
| 140 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work. including cutting chases and making good the wall etc. |
| 141 | 15 mm diameter |
| 142 | 25 mm diameter |
| 143 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 |
| 144 | 15 mm diameter |
| 145 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make confcrming to 1S.8931. |
| 146 | 15 mm diameter |
| 147 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 148 | 25 mm diameter |
| 149 | Providing and placing on terrace (at all floor levels) polyethylene per litre 10.20 water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 150 | Providing of Internal Electrification Installation. |
| 151 | COPPER WIRING IN PVC CONDUIT. |
| 152 | Wiring for light point / Fan point / Exhaust Fan point / Call bell point with 1.5 mm. FR PVC insulated copper conductor single core cable in surface / recessed steel conduit with modular type switch modular plate, suitable G.I. box and earthing the point with 1.5 mm 2 FR PVC insluted copper conductor single core cable etc., as reqd. |
| 153 | Group A |
| 154 | Group B |
| 155 | Group C |
| 156 | Wiring for light pt/power plug with 4x4mm2 FR pvc ins. Cu.cond.s/c cable in surface /recessed steel conduit alongwith 2 no. 4mm2 FR pvc.ins.Cu.cond. s/c cable for loop earthing etc.as reqd. |
| 157 | Wiring for circuit/ Sub-main wiring along with earth wire with (the following sizes) of FR PVC insulated copper conductor single core cable in surface / recessedsteel. conduit etc. as reqd. |
| 158 | 2x2.5mm2+1x2.5mm2 earth wire |
| 159 | 2x4mm2+1x4mm2 earth wire |
| 160 | 2x6 mm2+1x6mm2 earth wire |
| 161 | Telephone Wiringin existing conduit |
| 162 | Supplying and drawing (following pair) 0.5 FR PVC insulated copper conductor unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as reqd |
| 163 | 1 Pair |
| 164 | S/F (following Modular type switch/socket) on the existing switch box i/c connectionetc.as reqd. |
| 165 | 5/6 amps. Switch |
| 166 | 15/16 amp.s switch |
| 167 | 3 pin 5/6 amps.socket outlet |
| 168 | 6 pin 15/16 amps.socket outlet |
| 169 | S/F 25 amp Air Conitioner power plug point i/c 4 modules metal box on surface or in recess 4 modules plate and cover in front, 25 amp modular starter 25 amp moduar socket outlet and 25 amp plug i/c connection etc as reqd. |
| 170 | Supplying & fixing stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as reqd. |
| 171 | S/F (following size/modular switch plate base and cover plate for modular switch in recess SSS as reqd. |
| 172 | 1 or 2 module (75mmx75mm) |
| 173 | 6 module |
| 174 | 8 module |
| 175 | 12 module |
| 176 | S/F 3 pin amp ceiling rose on the existing junction box/wooden box i/c connection etc. reqd. |
| 177 | Providing and Fixings (following capacity TP & N) dis-connection fuse switch unit inside the existing cubicle panel board with ISI marks HRC fuses including drilling holes in the cubicle panel board, making connection as reqd. |
| 178 | 400 amp. T.P. & N |
| 179 | Providing and fixing (following rating and breaking capacity) MCCB in existing cubicle panel board including drilling holes in cubicle panel & making connection as reqd |
| 180 | 4 Pole MCCB 400 amp 35 KA |
| 181 | S/F (following way) single door pole & neutral, sheet MCCB distribution board, 240V on surface/recessed complete with tinned Cu.bus bar neutral bus bar, earth bar, din bar detachable gland plate, interconnection, phosphatized and power painted i/c earthing etc.as reqd. (But without MCB/RCCB/Isolator) |
| 182 | 12 Way Double door |
| 183 | S/F (following way) single door pole & neutral, sheet MCCB distribution board, 240V on surface/recessed complete with tinned Cu.bus bar neutral bus bar, earth bar, din bar detachable gland plate, interconnection, phosphatized and power painted i/c earthing etc.as reqd. (But without MCB/RCCB/Isolator) |
| 184 | 2+8way |
| 185 | S/F 5 amp. to 32 amp.rating 230V \"B\" series MCB for lighting and other load of (following pole) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. |
| 186 | Single pole |
| 187 | S/F (following rating) double pole 240V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd. (a) 63 amp. |
| 188 | 63 amp |
| 189 | P/S 25mmx5mm copper strip in 40 dia pipe from earth electrode as reqd. |
| 190 | P/S 25mmx5mm copper strip on surface or in recessed for connection etc. as required. |
| 191 | S/F bus bar chamber with 4 strips Cu. Bus bar length 900mm suitable suitable for 200 amp.capacity complete with all accessories i/c connection earthing the body etc.as reqd. |
| 192 | S/F 48\" (1200mm) A.C. ceiling fan complete with down rod, canopy, 3 (three) blades but without regulator etc as reqd. (Make Bajaj/ Usha or similar |
| 193 | S/F 305mm sweep exhaust fan complete with all accessories i/c connection etc as reqd |
| 194 | S/F 1.5 tone capacity split type Air Conditoner ( Diamond, 3 star, 5G 29, G-SC 18 FD 3 WJH) complete with Indo vltage Stabilizer, Automatic 4 KVA (140-280 for 1.5 ton.) |
| 195 | Supplying, Erection, testing and commissioning of (pre-wired) wall bracket/ceiling fittings of all sizes and shapes containingCFL/LED/W GLS lamps per fitting, complete with all accessories including connection etc. as required(havell,s /Bajaja/Phillips/Cromton). |
| 196 | Ceiling fitting (Surface) with 12/15 watt LED Lamp. |
| 197 | Supplying , Installation, testing and commissioning of LED Lamp (havell,s /Bajaja/Phillips/Cromton). includingconnection etc. as required.With CFL 12/15 Watts Lamp. |