|
| 1 | Supplying chemical emulsion in sealed containers including delivery as specified. |
| 2 | Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 3 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 4 | Treatmentofsoilunderexistingfloorsusingchemical emulsion © one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement: 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 5 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 6 | 1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 7 | Makingplinthprotection 50mmthickofcementconcrete 1:3:6 (1cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 10 | Shelves (Cast in situ) |
| 11 | Lintels,beams,plinthbeams,girders,bressumersand cantilevers |
| 12 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete above plinth level. |
| 13 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 14 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 15 | Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 16 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 18 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 19 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 20 | 100x10 mm |
| 21 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 22 | 125 mm |
| 23 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 24 | Single rubber stopper |
| 25 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer- in-Charge. |
| 26 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer\"s specification & drawing. |
| 27 | 30 mm thick plain PVC door shutters |
| 28 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanizedmild steel section madeof requiredshape & size asper CPWDSpecification,uPVC extrudedglazingbeads,interlocksandlnlinesashadaptor(where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum8mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.Note:-StructuraldesignproofcheckedfromaGovernment Engineering Institute,tobeprovidedbythemanufacturerfor (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds |
| 29 | Fixed window/ ventilator with mullion /transom.Using R1 series with frame (33 mm & above) x (35 mm & above) & mullion (33 mm & above) x (50 mm & above). (Height upto 0.90 metre) |
| 30 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). |
| 31 | Casement door singlepanel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre). |
| 32 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 33 | Ingratings,frames,guardbar,ladder,railings,brackets, gates and similar works |
| 34 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 35 | Providingand fixingplainmultipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 36 | 6mm thick Cement bonded woodparticleboardasper IS:14276 |
| 37 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion. |
| 38 | Bend 87.5°75 mm bend |
| 39 | Bend 87.5°110 mm bend |
| 40 | 12 mm cement plaster of mix: |
| 41 | 1:4(1 cement: 4 fine sand) |
| 42 | 12 mm cement plaster finished with a floating coat of neat cement of mix: |
| 43 | 1:4(1 cement: 4 fine sand) |
| 44 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 45 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 46 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approvedbrandandmanufacture,includingapplyingadditionalcoats wherever required to achieve even shade and colour. |
| 47 | Two coats |
| 48 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 49 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 50 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 51 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface |
| 52 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 53 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 54 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge. |
| 55 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 56 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall |
| 57 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 58 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 59 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 60 | Of area 3 sq. metres and below |
| 61 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : |
| 62 | Of sectional area 40 square centimetres and above |
| 63 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 64 | For thickness of tiles 10 mm to 25 mm |
| 65 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 66 | Asbestos Cement sheet |
| 67 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : |
| 68 | Thickness above 10 mm up to 25 mm |
| 69 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 70 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge. |
| 71 | Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade |
| 72 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 73 | W.C. pan with ISI marked white solid plastic seat and lid |
| 74 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 75 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 76 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 77 | Kitchen sink without drain board610x510 mm bowl depth 200 mm |
| 78 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 79 | Flexible pipe32 mm dia |
| 80 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 81 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 82 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 83 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. |
| 84 | ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. |
| 85 | 20 mm nominal dia Pipes |
| 86 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 87 | 25 mm nominal dia Pipes |
| 88 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 89 | 45 cm length15 mm nominal bore |
| 90 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 91 | 100 mm diameter |
| 92 | Providing and placing on terrace (at all floor levels) polyethylene water storagetank,IS : 12701marked,withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 93 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 94 | 15 mm nominal bore |
| 95 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 96 | 15 mm nominal bore |
| 97 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 98 | 15 mm nominal bore |
| 99 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 100 | 15 mm nominal bore |
| 101 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 102 | Providing wood work in frames , trusses, purlins, rafters etc sawn and put up in position with Superior hard wood Cat-II (A) |
| 103 | Providing cement concrete surface drain including earthwork excavation 10 cm thick base concrete and 15 cm thick side wall with 1:3:6 ( 1 cement : 3 Coarse sand: 6 graded stone aggregate of 40 mm nominal size) cement concrete finished with 1:4 (1 cement : 4 sand) a floating coat of neat cement inside the drain and its top and exposed surface including earthwork in excavation and disposed of surplus earth etc. |
| 104 | 15 X15 cm Surface drain |
| 105 | Providing and fixing CPVC gate valve of approved quality (screwed end). |
| 106 | 25mm nominal bore |
| 107 | Providing and fixing CPVC extension nipple for polythylene water tank pipe fittings of approved quality. |
| 108 | 25mm nominal bore |
| 109 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent (size, shape and pitch of corrugation as approved by Engineer-In- charge) 0.50mm (+0.50%) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns, sheet should have protective guard film of 25 micron minium to avoid scratches during transportation and should be supplied in single length up to 12 metres or as desired byEngineer-In-Charge. The sheet shall be fixed using self drilling/ self tapping aluminium screws (Xylan) of size (5.5X55mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 110 | Extra for providing and fixing aluminium wind ties of 40x 5mm flat. |
| 111 | Providing and fixing in position eaves or facia board with 18mm thickWPC board of approved quality and 30cmwide including nailing etc complete as per the direction of Engineer-in-charge. |
| 112 | Providing and fixing soil, waste and vent pipes |
| 113 | 75mm dia PVC pipe |
| 114 | 110mm dia PVC pipe |
| 115 | Providing and fixing PVC bend of required degree with access door of approved quality. |
| 116 | 100 mm dia |
| 117 | 75mm dia |
| 118 | Providing and fixing PVC Nahani Trap including cost of cutting and making good the walls and floors complete. |
| 119 | 110mm inlet and 75mm outlet |
| 120 | Providing and fixing PVC single equal plain junction of required degree etc complete. |
| 121 | 100x100x100mm |
| 122 | 75x75x75mm |
| 123 | Providing and fixing C.P. jali of approved quality |
| 124 | 100mm |
| 125 | Providing and fixing C.P brass two way bib cock of approved quality. |
| 126 | 15mm nominal bore |
| 127 | Constructing cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregates 20mm nominal bore) masonry chamber for underground C.I. inspection chamber and bends, C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4mix (1 cement :2coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design |
| 128 | Inside dimensions 455x610 mm and 45 cm deep for single pipe line |
| 129 | Providing and fixing panelling in uPVC door shutters and partitions etc complete as per the architectural drawing and as per the direction of Engineer-in-charge (of profile manufacturer and their authorized fabricator of Fenesta, veka, Encraft, Lingal, the window factory, Aluplast, Duroplat). |
| 130 | uPVC panels of size 100mmX20mm |
| 131 | Providing and fixing glazing in uPVC door shutters and partitions etc withEPDM rubber/ neoprene gasket etc. complete as per the architectural drawing and the direction of Engineer-in-charge. |
| 132 | With float glass panes of 5.0 mm thickness |
| 133 | Providing and fixing bright finished brass door casement handle with lock and key of Godrej or equivalent make with necessary brass screws etc complete. |
| 134 | Providing and fixing mosquito net using aluminium mesh complete of approved quality as directed by the Engineer-in-charge including cost of mesh, fixing and other materials and labour charges. |
| 135 | Providing and fixing curtain rods of 1.25 mm thick stainless steel with two stainless steel brackets fixed with brass screws and wooden plugs, etc., wherever necessary complete : |
| 136 | 20mm diameter (Heavy type) |
| 137 | Felling,Cutting and trimming into pieces of mango tree, having girth of 2.0 mtrs of the main tree trunk forheight of 6.0 mtrs and the balance tree trunk of girth 1.00 mtrs from a height 6mtrs to 10.0 mtrs having 10 Nos brancehs spreading to a length of 6.00 mtrs including cutting and trimming of tree trunks, leaves, branches and removing roots from the soil including disposal of tree trunk, root, branchesand other debris etc from the site by means of mechanical transport within an average lead of 10.00 kms including loading and unloading etc complete as per the direction of Engineer-in-charge. |
| 138 | \"Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent roofing acessories 0.50mm (+0.50%) total coated thickness with aluminium zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping aluminium screws complete.\" |
| 139 | Ridge plain(500-600 mm) |
| 140 | Valleys |