| 1 | Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer. Cement Concrete Grade M-15 and above and PCC blocks |
| 2 | Supply and erection of P.C.C. pole as per REC manual no 15/1979 (ammended upto date) and as per latest Discom specifications with factor of safety 2.5 including excavation of pit upto pole planting depth 1/6th of pole length. and back filling with stone aggregate/boulders and soil by ramming and watering etc complete as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 9.0 Mtr long PCC pole of 200 Kg Working Load |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - 1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 4 | 1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 5 | Supply and erection of GI stay set confirming to pattern-1 of BS:16/1974 and as per latest Discom Specifications complete with stay rod with anchor plate fitted with cast iron cross head and steel bow, in cement concrete 1:3:6 including excavation of pit-re-filling etc complete as reqd. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Stay set of dia 16mm, 1.8m long stay rod and anchor plate 300 x 300 x 4.0 mm |
| 6 | Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom\"s specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. LT cross arm 600 mm long with clamp |
| 7 | LT cross arm 1200 mm long with clamp |
| 8 | Suspension clamp with eye hook & Pole clamp |
| 9 | Dead end clamp with eye hook & Pole clamp |
| 10 | Type A LT connector for Aerial bunched cable |
| 11 | Type B LT connector for Aerial bunched cable |
| 12 | Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discom\"s standard specifications,suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 100 mm x 70 mm |
| 13 | Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discom\"s standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 75mm x 90mm |
| 14 | 100mm x 110mm |
| 15 | Supplying and drawing overhead steel core Aluminium conductor (ACSR) ISI marked(IS 398 part II-1996) on existing cross arms through insulator with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 50 Sqmm of (6+1) 3.35 mm (Insulated Rabbit) for LT |
| 16 | Supplying and laying of Hot dip galvanized steel stay wire of 550-900 N/mm Quality confirming to IS-2141/2000 in all respect Including chemical composition (Heavily coated Hard quality) of dia 7/3.15 mm(7/10 SWG) and as per latest Discom specs. etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 17 | Supply and fixing of 11 / 33. KV Stay insulator as per IS:5300/1969 and as per Discom\"s standard specifications etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 110 x 75 x 22mm 11 KV Stay Insulator |
| 18 | Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . 1 X 25 sq. mm. + 1X25 sq. mm. (insulated) |
| 19 | 3 X 25 sq. mm. + 1X25 sq. mm. (insulated) |
| 20 | Labour charges for Dismantling of existing electric poles (PCC poles, MS channel, Lattic tower 12.6mtr. , 11 mtr. along with the ACSR Conductors, 11KV/33KV/LT line etc. 11KV insulator LT insulator guard wires, staywires and other electric items of the pole coming along the alignment of the road and removal and re- rolling PCC pole, MS channel different sizes as well as handing over the same to DISCOM store including transportation from site to store and stacking of dismantling material in store and as per the direction of Engineer Incharge and clean the site good as per the requirement and submit the receipt from DISCOM/ concering authority, including all complete works. |
| 21 | Labour charges for Trimming of tree branches/plants and prepairing route approaches for electric proposed line complete with prior permission of local authority in writing , taking proper shutdown from discom office and inform to DISCOM after complete the work. |
| 22 | Total S.No 01 to 21 Amount 21838 Say 45.00 Lacs Please Enable Macros to View BoQ information |