| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding, removing rubbish off the permises complete all as specified and as directed. |
| 2 | Demolition of plain cement concrete (un-reinforced) in ground floors, pavings and in foundations not exceeding 15cm thickness (below or above ground level) including removal of demolished material out side MD land complete S&Fall as specified and as directed. |
| 3 | M&L for 25 mm thick cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as sub base below floor tiles etc. complete S&Fall as specified and as directed. |
| 4 | M&L Non - skid colour Ceramic tiles 7 to 8 mm thick(square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:4, complete all as specified and as directed |
| 5 | M&L for colour Glazed ceramic tiles 450x350x7mm thick, in dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & incl 10mm thick as back coat in CM 1:3 complete all as specified and as directed. |
| 6 | M&L for light shade Vitrified tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & incl 15mm thick screed bed in CM 1:4, complete all as specified and as directed. |
| 7 | M&L for light shed vitrified ceramic tiles 10mm t hick (square/rectangular) polished, area of each tile not exc 0.36 sqm in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 10mm thick backing coat in CM (1:3) complete S&Fall as specified and as directed. |
| 8 | Taking down cementor cement lime plaster, any description, on brick walls including racking out joints hacking for keyscrubbing down with water etc. complete S&Fall as specified and as directed. |
| 9 | M&L for rendering 15mm thick on other than fair faces of brick or concrete in CM 1:6 finishing even and smooth without using extra cement complete S&Fall as specified and as directed. |
| 10 | M&L for rendering 10mm thick on fair faces of brick or concrete in CM 1:6 finishing even and smooth without using extra cement complete S&Fall as specified and as directed. |
| 11 | M&L for rendering 5mm thick on fair faces ofconcrete surfaces in cement mortar 1:3in ceiling surface finished even and smooth with out using extra cement complete S&Fall as specified and as directed. |
| 12 | M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete S&Fall as specified and as directed. |
| 13 | M&L for preparation of newly plastered surfaces of walls and applying two coats of Exterior emulsion paint over a coat of primer S&Fall as specified and as directed. |
| 14 | M&L for preparation of new plastered surfaces and applying two coats ofwhite wash on ceilling and as directed by eingineer in charge |
| 15 | Taking down chowkats or frames (without taking off shutters from frame ) not exceeding 1.5 sqm each complete S&Fall as specified and as directed.Note:- The quoted rate shall include the cost ofcutting holes for removing / inserting hold fasts and making good disturbed portionswith PCC 1:2:4 type B-0 or in CM 1:4 after refixing of frames / fixing new frames.. |
| 16 | Taking down chowkats or frames (without taking off shutters from frame ) exceeding 1.5 sqm but not exceeding 4 Sqm each complete S&Fall as specified and as directed.Note:- The quoted rate shall include the cost ofcutting holes for removing / inserting hold fasts and making good disturbed portionswith PCC 1:2:4 type B-0 or in CM 1:4 after refixing of frames / fixing new frames.. |
| 17 | S&FPowder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete S&Fall as specified and as directed. |
| 18 | S&F Powder coated aluminium window and ventilator shutters,fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete S&Fall as specified and as directed. |
| 19 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete S&Fall as specified and as directed. |
| 20 | S&FGalvanised steel wire cloth, 0.56mm nominal dia of wire and average with of aperture 1.18mm complete S&Fall as specified and as directed. |
| 21 | S&F 4.8 mm thick Sheet glass,ordinary quality and glazing with rubber beeding in square n exc 0.5 sq. m in each pane complete S&Fall as specified and as directed. |
| 22 | S&F 4.8 mm thick Sheet glass,ordinary quality and glazing with rubber beeding in square exc 0.5 sq. m in each pane complete S&Fall as specified and as directed. |
| 23 | S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete S&Fall as specified and as directed. |
| 24 | S&F factory made PVC Solid Door frame of size 50mmx47mm made out of 5mm plain coloured PVC sheet reinforced with MS Square tube as per specification and drawings shown in SSR Part II. |
| 25 | S&F Factory made Solid panel PVC Door Shutter of 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of plain clour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement as per specification and drawing shown in SSR Part II. |
| 26 | S&F 125 mm size Aluminium butt hingesextruded aluminium alloy with galvanised steel wire pin anodised, type B-21 complete S&Fall as specified and as directed. |
| 27 | S&F in repairs200 mm long Aluminium anodised barrel tower bolts of extruded aluminium section complete S&Fall as specified and as directed. |
| 28 | S&F 150 mm long Aluminium alloy handles cast type anodised complete S&Fall as specified and as directed. |
| 29 | Demolition of Brick work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stone work and precast concrete articles complete S&Fall as specified and as directed. |
| 30 | M&L for Brickwork with sub-class `B\" old sizebricks, straight or curved on plan exceeding 6m mean radiusbuilt in cement mortar 1:6 complete S&Fall as specified and as directed. |
| 31 | M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 20mm screed bed in CM 1:4 complete S&Fall as specified and as directed. |
| 32 | Taking up or down 15mm bore steel tubing and connections, including cleaning and removal to store complete S&Fall as specified and as directed. |
| 33 | Taking up or down 20mm bore steel tubing and connections, including cleaning and removal to store complete S&Fall as specified and as directed. |
| 34 | Supplying and laying20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified |
| 35 | Supplying and laying 16mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified |
| 36 | Dismantling PVC water tanks of capacity exc 500 litre & n exc 1000 litres complete S&Fall as specified and as directed. |
| 37 | S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks triple layers (cylindrical vertical with closed top) hoisted & fixed in position complete S&Fall as specified and as directed. |
| 38 | S&F in repair 15 mm bore Hospital Elbow/wrist operated long handle action pillar taps CP brass with capstone head with or without lettered hot or cold fancy type heavy duty complete S&Fall as specified and as directed. |
| 39 | S&F in repair 15 mm bore pillar taps CP brass with capstone head with or without lettered hot or cold fancy type heavy duty complete S&Fall as specified and as directed. |
| 40 | S&F in repairs low levelflushing cistern PVC valveless, syphonic action type 10 ltrs capacity, white with inlet, ball valve, float and handle including brackets complete S&Fall as specified and as directed. |
| 41 | S&Fin repairs 32mm dia PVC waste pipe fixedcomplete S&Fall as specified and as directed. |
| 42 | Taking down and removing of existing water proofing treatment of any description completely, taking down of old cement plaster if any or roughening of surfaces and cleaning the top surfaces of RCC slab with using wire brushes and water to remove all the dust and loose particles etc complete all as specified and as directed. |
| 43 | M&L for rendering 15mm thick in cement mortar 1:3 on roof/concrete surfaces with using water proofing compound as per manufacturers instructions, surfaces finished even and smooth without using extra cement complete all as specified and as directed. Note:- Supply only of water proofing compound/admixture shall be measured and paid separately. |
| 44 | Supply only of liquid water proofing compound of approved make . |
| 45 | M&L for applying water based Polyurethane modified dispersion (single component, cold applies, non toxic VOC) in 03 coats including 01 coat of epoxy primer @ 0.15 kg per sqm in two coats, complete as per manufacturers instruction and as directed by Eng.-in-Charge. |
| 46 | S&F in repairs bib taps, CP fancy typewith crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15 mm bore dia and fixed complete all as specified and as directed. |
| 47 | S&Fin repair PVC connections both end brass union and length 600 mm long for 15mm bore pipe complete all as specified and as directed. |
| 48 | S&F in repair angle valve, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 49 | M&L forstainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. |
| 50 | M&L for Hard core of gauge n.exc 63 mm , with broken stone or boulders , deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface complete all as specified and as directed. |
| 51 | M&L for 100mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregates as in sub base of floor complete all as specified and directed |
| 52 | M&L for 75 mm thick plain cement concrete 1:2:4typeB2,using 20mm graded stone aggregate as in floors , paths, pavings etc surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 53 | S&F steel framed work such as grill, grating etc, with ends bars shouldered and/or rivetedof forged into spikes, frameed guardbars, barred iron doors, ladders, frame balusters, walk ways, raillings, frame work of water tanks and similar work confirmingto FE 290Gde E-165 and portions frame framed and hung as gates including pintle hinges, steps hand-made sliding bolt etc complete all as specified and as directed. |
| 54 | S&F in repair for 4 lever Aluminium Mortice lock, vertical type, size 100 mm for Aluminium Doors/Gates complete all as specified and as directed. |
| 55 | S&F in repairs 15mm dia stop valve cast copper alloy CP fancy type long shank and cup complete all as specified and as directed. |
| 56 | S&F in repairs 550x400 mm size vitreous china wash hand basin, white with flat back with CP brass waste coupling and PVC flexible waste pipecomplete all as specified and as directed. |
| 57 | S&F in repair vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern) including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium or aluminised hinging device complete all as specified and as directed. |
| 58 | S&F in repair Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including to connection to drain complete all as specified and as directed. |
| 59 | S&F in repairs Gun metal globe or gate valves with iron wheel head screwed both ends for iron CPVC 20 mm bore and fixed as in repair complete all as specified and as directed. |
| 60 | S&F 20mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed. |
| 61 | S&F in repairs. for 32mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc with long screwed shanks and fly nuts, flanged ends bedded in red lead cement complete all as specified and as directed. |
| 62 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed. |
| 63 | Excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out in soft / loose soil, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed. |
| 64 | Excavation in trenches not exc.1.5 m wide and not exc.1.5 m in depth for foundation or for shafts, walls, manholes etc not exc.10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed. |
| 65 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed. |
| 66 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed. |
| 67 | M&L for Rolled mild steel work conforming to Fe 290 Gde E-165 as in stanchions, posts,with flange plates, caps, bases, splices, angle brackets, cleats and other connections complete all as specified and as directed. |
| 68 | M&L forRoof Trusses (framed), trussed, purlins, rails and fastenings and heavy bracket framing ( Beam, tee, angles, Channel or flat section) including distance pieces, cleats etcconforming to Fe 290 Gde E-165 complete all as specified and directed |
| 69 | M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of Fe 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 70 | M&L for Preparation of new or previously un treated surfaces of steel and iron surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome paintcomplete all as specified and as directed. |
| 71 | M&L forpreparation of newly plastered surfaces and applying two coats of cement base paint over a coat of suitableprimer complete all as specified and as directed. |
| 72 | M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compoundgrade \"A\" complete all as specified and as directed. |
| 73 | Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25 cm in hard/dense soil complete all as specified and as directed. |
| 74 | Removing excavated material o a distance exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and as directed. |
| 75 | M&L 75mm thick cement concrete type D-2 1:4:8 (40mm graded aggregates) as in sub base complete all as specified and as directed |
| 76 | M&L for Sand filling under floors/pavings, below tiles, including watering and consolidation all as specified and directed |
| 77 | M&L for Machine pressed precast concrete interlocking paver block any shape and size conforming to IS-15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment complete all as specified and as directed. |
| 78 | M&L for factory casted machine made precast PCC solid block (1:2:4) type B1 using 20mm graded stone aggregate as in kerb stone of setting in CM (1:4) etc incl necessary earthwork complete all as specified and as directed. |
| 79 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bulbs etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 80 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLS cable 1100 Volts grade ISI-694 marked with valid CML No. single core multistranded cable in and including heavy duty concealed PVC conduitnot less than 20mm dia and accessories ISI marked with valid CML No (IS-9573-1983 for conduits and IS: 3419: 1976 for conduit accessories) and including 1.6 mm thick (recessed) for fixingof switches, sockets and fan regulators etc including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire complete all as specified and as directed. for One light / fan / security light/5Amps Indp socket / Bell point controlled by one switchpoint controlled by one switch |
| 81 | All as per item no.81 hereinabove but for one 3 pin socket outletpoint 5 Amps controlled by one switch on same board along with other switches |
| 82 | All as per item no.81 hereinabove but for one 3 pin socket outletpoint 5 Amps controlled by one switch on independent board. |
| 83 | All as per item no.81 hereinabove but for one 3 pin socket outlet point 15 Amps controlled by one switch on independent board with 4sqmm FRLS cable (for phase, neutral and earth). |
| 84 | S&F in repairs Modular Switch 5/6 Amps, 1module 1 Way complete all as specified and as directed. |
| 85 | S&F in repairs Modular Switch 15/16 Amps, 1 Module 1 Way complete all as specified and as directed. |
| 86 | S&F in repairs Modular Socket 5/6 Amps, 2 Module, 2 and 3 pin complete all as specified and as directed. |
| 87 | S&F in repairs Modular Socket 15/16 Amps, 2 Module 2/3 pin complete all as specified and as directed. |
| 88 | S&F in repairsModular Fan Regulator Step type, 2 Module 120W complete all as specified and as directed. |
| 89 | S&F in repairs3 Module Cover Plate with frame and Metal Flush Box complete all as specified and as directed. |
| 90 | S&F of 8 Module Cover Plate with frame and Metal Flush complete all as specified and as directed. |
| 91 | S&F in repairs Ceiling rose, 3 plate /PVC/ polycarbonate, isolated body complete all as specified and as directed |
| 92 | S&F 4 feet LED tube light of 20 watt Batten with integrated electronic driver having THD < 20% and aluminium housing with necessary fixing screws and connected up to ceining ceiling rose including taking down existing tube light fitting of any type and making good complete all as specified and as directed |
| 93 | S&F 2 feet LED tube light of 10 watt Batten with integrated electronic driver having and aluminium housing with necessary fixing screws and connected up to ceining ceiling rose including taking down existing tube light fitting of any type and making good complete all as specified and as directed |
| 94 | S&F SPN DB Double door 8 way with tray for provision of MCBs, and Dolly for earth and neutral complete all as specified and as directed. |
| 95 | S&FMCB, SPN 32 Amps, \"C\" Curve, 10 kA, Complete all as specified and as directed. |
| 96 | S&F MCB Single Pole 6-32 Amps, 10 kA, C Curve complete all as specified and as directed. |
| 97 | M&L for sub main wiring with two runs of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 6 Sqmm copper multistranded conductor including and drawing into concealed PVC conduit of suitable size ISI marked Medium grade, , including 6 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth including taking down of existing submain wiring complete all as specified and as directed. (For MDB to SBD). |
| 98 | M&L for sub main wiring with two runs of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 1.5 Sqmm copper multistranded conductor including and drawing into concealed PVC conduit of suitable size ISI marked Medium grade, , including 1.5 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth including taking down of existing submain wiring complete all as specified and as directed. |