| 1 | Surface excavation n.exc(not exceeding) 30 cm deep and averaging 15cm deep and getting outin any type of soil complete all as specified and as directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any kind of soil complete all as specified and as directed. |
| 3 | Excavating in trenches, exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any kind of soil complete all as specified and as directed. |
| 4 | Material and labour for providing cement concrete 1:4:8 type D2 (Using 40mm graded stone aggregate) in foundation, mass concrete and filiings, complete all as specified and as directed. |
| 5 | Material and labour for Use and waste of formwork to sides of concrete foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc. for a rough finished surface of concrete,all as specified & directed. |
| 6 | All as per item No. 5.00but to sides of columns, pillars, piers, posts and struts etc.,all as specified and as directed. |
| 7 | All as per item No. 5.00 but to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, and simillar work, complete all as specified and directed. |
| 8 | All as per item No. 5.00 but in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 9 | All as per item No. 5.00 butas inFchullah hoods, chajjas, troughs and similar items including edges etc., all as specified and as directed. |
| 10 | Material and labour for reinforced cement concrete M: 25 (Design Mix) using 20 mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc., all as specified and as directed. |
| 11 | All as per item No. 10.00 but in columns, pillars, piers, posts and struts etc.,all as specified and as directed. |
| 12 | All as per item No. 10.00 but in Beams, cantilevers, ressummers, lintels over 1.5m span concreteetc., complete all as specified and directed. |
| 13 | All as per item No. 10.00 butasin slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed. |
| 14 | All as per item No. 10.00butas in chajja complete all as specified and as directed. |
| 15 | M&Lformwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide, complete all as specified and directed. |
| 16 | Material and labour Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement, complete all as specified and as directed. |
| 17 | Material and labour Mild steel TMT bars 6-8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement, complete all as specified and as directed. |
| 18 | All as per item 17.00 butbefore, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, complete all as specified and as directed. |
| 19 | Material and labour for brick work with fly ash bricks straight or curved on plan exc 6 mtr mean radiusbuilt in CM 1:6 (Using old size brick) complete all as specified and as directed. |
| 20 | Material and labour for brick work with fly ash brick, straight or curved on plan to any radius built in half brick thick wall built in CM 1:4 (Using old size brick) complete all asspecified and directed. |
| 21 | Material and labour for Rendering 15 mm thick in CM 1:4 over and including wter proofing wll putty ndusing water proofing liquid compound as permanufacturer instructions on brick or concrete surfaces and finishing surfaceseven &fair without using extra cement. complete all asspecified and as directed. Note: Water proofing liquid compound shall be measured and paid separately under respective item. |
| 22 | Material and labour for Rendering 10 mm thick in CM 1:6 on fair faces of brick masonry or concrete surfaces finished even & smooth without using extra cement over and including wall care putty complete all asspecified and as directed. |
| 23 | Supply only Liquid water proofing compound of approved quality, complete all as specified and directed. |
| 24 | Material & labour for rendering5mm thick in cement mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement all as specified and as directed. |
| 25 | Material and labour for preparation of newly plastered surface on wall and applying two coats of distemper oil emulsion over a coat of primer over one coat of wall care putty of not less than 2.0 mm thick including preparation of surfaces complete all as specified and directed. |
| 26 | Material and labour for preparation of newly plastered surface on ceilling and applying two coats of distemper oil emulsion over a coat of primer over one coat of wall care putty of not less than 2.0 mm thick including preparation of surfaces complete all as specified and directed. |
| 27 | Material & labour for prepration of plaster surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including water proofing wll putty & priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 28 | Material and labour for Moorum / red bajri brought from outside MD land as in filling under floors / pavings / berms, laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering etc complete all as specified and directed. |
| 29 | Material and labour for Earthwork brought from outside MD land as in filling under floors , spreading and levelling in layers not exceeding 25 cm thick, spread, levelled and rammed including watering etc complete all as specified and directed. |
| 30 | Material and labour for hardcore of gauge not exc 63 mm, broken stones or boulders deposited, spread and levelled in layers not exc. 15 cm thick, watered & rammed to a true surface complete all as specified and as directed. |
| 31 | Material and labour for 75mm thick PCC 1:4:8, type D-2 using 40 mm graded stone aggregate as in sub base of floor and similar location all as specified and as directed. |
| 32 | Material and labour for 25mm thick cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in sub base of floor and similar location all as specified and as directed. |
| 33 | Materials and labour for dark shade vitrified ceramic tiles 10mm thick (square/rectangular), polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in cement mortar 1:4 (including bodder tile) complete all as specified and as directed. |
| 34 | All as per item No. 33.00 but as in vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match .over &incl10mm thick backing coat in CM 1:3 finished even and fair complete all as specified. |
| 35 | Material and labour for 75mm thick PCC 1:3:6 mix type C2 using 20 mm graded stone aggregate as in plinth protection and surface to be finished fair and even including joints at every 2.5 m and at all corners filled with 85/25 grade bitumen and sand mixed in 1:2 ratio by weight complete all as specified and as directed. |
| 36 | S&F5.5mm thick tinted sheet glass ordinary quality and glazing with Al glazing clips& EPDM beading in square exc 0.5 sqm in each pane,complete all as specified and directed. |
| 37 | Supply, fabrication and fixing anodised aluminium doors fixed or openableincluding frame/chowkats etc from hollow rectangular sections like chowkats of size 100 x 44mm x 1.59mm (appx), vertical styles of size 82 x 44 x 1.59mm (appx) top and middle rails of size 82 x 44 x 1.59mm (appx) bottom rails of size 114 x 44 x 1.59mm (appx) complete including necessary jointing cleats, glazing clips, anodised aluminium beading and rubber gasket etc for securing glass, anodised aluminium fittings such as handles, other standard fittings, aluminium tower bolts - 2 Nos, Hydraulic Door closer of designation No-3- 01 No and accessories for locking arrangements etccomplete all as specified and directed. Note:- Glazing shall be measured and paid for separately under respective items complete all as specified and directed. |
| 38 | Supply and fix colour powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 39 | S&F10 mm thick toughned glass as in hinged door, partition automatic doors and similr work incl300 long SS handle both side of shutter, top, bottom spring cutting shap, drilling holes required all as specified and directed |
| 40 | Supply and fix aluminum (colour powder coated) three track sliding window comprising of one fly proof shutter and two glazed shutters with frames of size 92.0mm x 31.75mm x 1.30mm thick and shutter frames of size 40mm x 18mm x 1.55mm thick with necessary joining cleats, glazing clips, rubber gasket, anodized aluminum snap beading and connected locking arrangement complete all as specified and as directed Notes : (i) Glass filling in panels of windows and aluminium wire mesh/wire cloth shall be deemed to be included in the quoted rate for the item;(ii) Aluminum alloy wire cloth in panels of wire gauzed shutter shall be 0.45 mm nominal dia of wire and avg width of aperture 1.40 mm, fixed with aluminium wire staples; (iii) Glass filling in panels of glazed shutter shall be 5 mm thick tinted sheet glass of approved make and shade/tint Make of Aluminium Sections powder coated : Jindal or techno commercially equivalent in specified makes. |
| 41 | Preparation of surfaces and providing and applying IWL make Koolkoat one coat primer IWL Koolkoat diluted with water in mix ratio of 2:1 is used as primer coat allow to dry for 2-3 hrs over a primer two coat of undiluted IWL Koolkoat. Stir well for homogeneity in interval of 4-5 hrs after first coat application and then applying without thinning. Both 1st and 2nd coats applied to attend DFT around 120-150 microns complete all as specified and directed. |
| 42 | Supply and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, SmartCare Damp Block 2K Supremo or approved equivalent, having 80% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per ASTM C 1202, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. Applying Smart Care Damp Block 2K Suprema in two coat 2 kg/sqmt consumption, The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc, complete as per manufacturers specifications and as directed |
| 43 | Material and labour for 20 mm thick Granite (of any type) work (table rubbed & polished) in steps, jambs, pillars, window-cills, cooking platforms & like in cement mortar (1:4) including pointing into white cement (1:2) using marble dust with admixture of pigment to match shade of granite over 15 mm thick cement screed/renderingin CM 1:4 including roughening surfaces of old/newconcrete floor/wall by picking, sweeping clean and washing down with water to remove dust etc., and brushing neat cement slurry with 3.00 kg per sqmall as specified and directed. |
| 44 | M & L, Cement concrete in mass concrete 1:3:6 Type C2(using 40mm graded stone agg) as in fdn, filling complete all as specified and directed. |
| 45 | M&L for cement concrete1:2:4 type B-1in copings, and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 46 | M&L for Providing precast RCC ( 1:2:4 ) type B1 (using 20 mm gradded stone aggregate ) as inlandings,cover slabs shelves and set in CM 1:4 etc.including all necessary formwork complete all as specified and directed. |
| 47 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed. |
| 48 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where complete all as specified and directed. |
| 49 | Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 50 | Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contactwith backfill to be measured) |
| 51 | Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. |
| 52 | Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 53 | Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. |
| 54 | M&L hardcore of gauge n.exc. 63mmof broken stone boulders n exc 100 mm deposited, spread and levelled in layers watered and rammed to a true surface for hard standing complete all as specified and directed. |
| 55 | M&L for 100 mm thick cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base to floors finished even complete all as specified and directed. complete all as specified and directed. |
| 56 | M & L for Sand filling under floorings/pavement spread and levelled in layers n.exc 15 cm thick complete including watering and consolidation complete all as specified and as directed. |
| 57 | M & L of Machine pressed precast conctete interlocking paver block colour glossyfinishedrubber pressed any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade ® with Grey cement and pigment complete all as specified and as directed. |
| 58 | M&L cement concrete 1:2:4 type B1 (using 20mm graded aggregate)as in copingcomplete all as specifed and directed. |
| 59 | M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed in wall/ceiling as directed including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel modular boxessunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular coverwith frame any size complete all as specified for one light point controlled by one, one way switch. Note :- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate.All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly. |
| 60 | As per item No 59 above but One ceiling /exhaust fan point controlled by one switch and regulator complete all as specifed and directed. |
| 61 | As per item No 59 abovebut One 3 pin 5 amp socket out point on the same board with other switches complete all as specifed and directed. |
| 62 | As per item No 59 above but One 3 pin 5 amps socket out let point on independent board complete all as specifed and directed. |
| 63 | As per item No 59here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmmfor 15 amps power point complete all as specifed and directed. |
| 64 | As per item No 59here in before but wiring with 4 sqmm multi stranded cable and earth wire with copper conductor of size 4 sqmmfor AC Point complete all as specifed and directed. |
| 65 | M&L for sub main wiring with two single core PVC FR LSH insulated unsheathed stranded copper conductor and earth wire 1100 volt grade and drawing into PVC conduit not less than 20 mm medium grade concealed inwall of the following sizes :- 2x6 Sqmm with earth wire of 1x6 Sqmm.Note :- Accessories for point/sub main wiring like PVC junction box, bend, Tee, elbow shall be of same make. |
| 66 | Supply and fix ceiling rose surface type 2/3 terminal 5 amps complete all as specifed and directed. |
| 67 | Supply and fix Modular switch one way 6A, 1 module complete all as specifed and directed. |
| 68 | Supply and fix Modular switch one way 16A, 1 module complete all as specifed and directed. |
| 69 | Supply and fix Modular Socket 6A 2/3 pin combined 2 modulecomplete all as specifed and directed. |
| 70 | Supply & Fix Modular Socket 6A/ 16A2/3 pin combined 2 module complete all as specifed and directed. |
| 71 | Supply and fix Modular Fan step regulator,120 watt 2 modulecomplete all as specifed and directed. |
| 72 | Supply & Fix modular motor starter 16A , 2 module for AC complete all as specified and directed. |
| 73 | Supply and Fix Highly durable surface mounted 20 watts LED batten/surface constructed of fire retardant engineering grade extruded aluminium body 100 lumen per watt, min 2000 lumen and decorative end cap complete with driver including 3 core 1.0 sqmm copper conductor cable for connection and accessories all as specified and directed. |
| 74 | Supply and fix building security lightLED25 W with Lumen O/P 2500 with driver withrated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc complete all as specifed and directed. |
| 75 | Supply and Fix LED flood light 100W 230 V AC oudoor type with thermal management in multiple optics and equipped with IP 66 protection with impact and corrosion resistant complete with driver and lamp all as specified and as directed |
| 76 | Supply and fixsheet metal enclosure single pole & neutral for 240 volts 8 way with 100 Amp rated bus bar flush /surface mounting double door. complete all as specifed and directed. |
| 77 | Supply and fixsheet metal enclosure vertical triple pole & neutral(VTPN) with MCCB 4 pole 63 amps 16KA for 415 volts 4 way with 100 Amp rated bus bar flush /surface mounting double door complete all as specifed and directed. |
| 78 | Supply and fixMCB single pole 240 volt 6 to 32 amps 10 KA breaking capacity, \"C\" series complete all as specifed and directed. |
| 79 | Supply and fixMCB single pole and neutral240 volt 6 to40 amps 10 KA breaking capacity, \"C\" series, complete all as specifed and directed. |
| 80 | Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr.below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b)PCC pit in cement concrete 1:2:4 TYPE B-1 (.c)Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d)Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e)15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f)Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion. |
| 81 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete. Note : MES no given by E/M office will be written on fan before fixing complete all as specifed and directed. |
| 82 | Supply and laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 35Sqmm 3.5 core including testing after laid and jointed all as specified and as directedNote:- Excavation and earth work, cable protection shall be measured and paid separetely. |
| 83 | Excavation in trenches in any type of soft soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables, poles, stay and getting out of excavated material complete all as specified and directed. |
| 84 | M&L for sand cushioning with dry and clean sand over and under the under ground cable in trenches, ducts for cable protectionincliding levellling and consodilation complete all asspecified and directed.Note : Punned thickness shall be measured. |
| 85 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type- 1flat, size 250mm x 140mm x 40mm, complete all as specified and directed. |
| 86 | Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed. |
| 87 | Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth strip 25 x 4 mm by means of bolts, nuts, check nuts, washers of galvanized ironand connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 40mm bore, light grade 7.5m long as applicable and as per plate No. 5 of SSR 2009 and all as specified.(a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode (c) PCC pit in cement concrete (1:2:4) type B-1(d) 40 mm thick Pre-cast RCC cover with suitable handle. (e) Funnel with watering pipe of GI 20 mm nominal bore, mediumgrade & copper lug etc. (f) 40mm nominal bore medium grade GI protection pipe 7.50 m long for protection of earthing lead.(g) Requisite quantity of charcoal and common salt.(h) Connection to earthing test point and testing on completion. |
| 88 | Supply, installation, test and commissioning of LT Distribution Panel (CPRI Approved) cubicle type IP-65, Outdoor type conforming to IS 5039 of 1983 factory fabricated prewired,outdoor cubicle type, vermin proof, dust proof, fixed on 50x50x5mm MS angle iron frame fixed 600mm above ground level and 400mm below the ground level grouted in and including PCC 1:3:6 type C1 (using 20mm grade stone aggregate) and plane made out of 3.00 mm thick CRCA sheet for both outer shell and 2.00mm thick for inner shell both side open able supported on and including ISMC 75 X 40mm powder coated steel frame and totally powder coated with epoxy RAL 7032 siemen grey colour after seven tank phosphating treatment from inside and outside with locking arrangement, front and back opening type and fixing arrangement i.e nuts, bolts, washers, clamps etc, withnaturally air cooled epoxy insulated aluminium busbar TPN with detachable gland plate for incoming and outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside complete, all control cablesshall be of 2.5 Sqmm coppermulti stranded conductors and shall be properly bunched withsuitable size binding materials , ferruled for proper identification of colour Contd../- |
| 89 | Contd item No. 88codes and crimped with adequate size of lugs also toaccommodate,fixing 2 Nos danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and consisting of the following items, all as specified and as directed. Note : (i) LT Panel board should be CPRI approved as per IS-5039 of 1983. (A copy of valid CPRI type test report to be enclosed while obtaining aproval from GE). (ii) SLD diagram for LT Panelwill be got approved from GE before placing the order and final diagram will be fixed on the front and rear door. (iii) Rate for the same deemed to include in the quoted rates.comprising of the following :-(a) Busbar chamber for 3 phase & nuetral of capacity 500 Amps alumunium bus bar duly insulated fitted on heat shrinkable insulation and covered with colour sleeve.(b)Multifunctioning meter to measure Voltage, Ampere, KWH,PF - 01 Nos (c) One set of pilot lamp.(d)Incoming MCCB 250 Amps 4 Pole,415 volts with Microprecessor release setting type, 36 KA- 01 Nos (e) Outgoing MCCB, 4 polehaving current ratings 100 Amps, AC 415 Volts, withIcu=36 KA ,Ics = 100% ofIcu,with adjustable type overload setting (Min 70% to 100%) - Qty -01 Nos.(f)Outgoing MCCB, 4 polehaving current ratings 63 Amps, AC 415 Volts, withIcu=25 KA ,Ics = 100% ofIcu,with adjustable type overload setting (Min 70% to 100%) - Qty -04 Nos. |
| 90 | Material and labour for cable route indicator made out of PCC (1:2:4) type B1 of size 60cm x 15cm x 5cm thick grouted in PCC (1:2:4) type B1 pillar of size 30 cm x 30 x 30 cm in ground with and including necessary foam work and making on board 1100 Volt LT Cable with arrow indicating cable path (marking shall be engraved and colour painted), complete all as specified and directed. |