Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-02-2026 | Corrigendum No. 2 | BOQ | 12-03-2026 |
| 2 | 25-02-2026 | Corrigendum No 1A | Date | 12-03-2026 |
| 3 | 16-02-2026 | Date corrigendum 1 | Date | 05-03-2026 |
| Sl. No. | Item Description |
| 1 | NOTE:- (Applicable for all parts/items/):- The bidders/contractorsare advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.Schedule \"A\" Part-I(A) |
| 2 | Construction of Office& administrative Accn and Ancillary Accn, RCC framed structure, Single storey, ACC block construction including ATT, APP roof treatment , built in furnitures and all fittings and fixtures complete all as specified and as shown on drawings. |
| 3 | Construction of Transit Accn for 180 ORs , RCC framed structure, (G+2), ACC block construction including ATT, APP roof treatment , built in furnitures and all fittings and fixtures complete all as specified and as shown on drawings. |
| 4 | Construction of Transit Accn for 20 JCOs and Single living Accn for 01 Hav and 05 ORs and storage Accn , RCC framed structure, Single storey,, ACC block construction including ATT, APP roof treatment , built in furnitures and all fittings and fixtures complete all as specified and as shown on drawings. |
| 5 | Construction of Cook House and Dining Hall for 180 ORs , RCC framed structure, Single storey,, ACC block construction including ATT, APP roof treatment , built in furnitures and all fittings and fixtures complete all as specified and as shown on drawings. |
| 6 | Construction of JCO Mess, Dinning and Kitchen for transit JCOs and 02 permanent staff , RCC framed structure, Single storey,, ACC block construction including ATT, APP roof treatment , built in furnitures and all fittings and fixtures complete all as specified and as shown on drawings. |
| 7 | Construction of Armouries and Armourer , RCC framed structure, Single storey,, ACC block construction including ATT, APP roof treatment , built in furnitures and all fittings and fixtures complete all as specified and as shown on drawings. |
| 8 | Construction of Covered Accn for \"B\" Vehicles, MT drivers standby, Change room and Gen Set room, RCC framed structure, Single storey,, ACC block construction including ATT, APP roof treatment , built in furnitures and all fittings and fixtures complete all as specified and as shown on drawings. |
| 9 | Construction of Parking Shed for Bicycle and Scooter, RCC framed structure, Single storey,, ACC block construction including ATT, APP roof treatment , built in furnitures and all fittings and fixtures complete all as specified and as shown on drawings. |
| 10 | Construction of Parking Shed for Single Living Accn (01 Hav & 05 ORs), RCC framed structure, Single storey,, ACC block construction including ATT, APP roof treatment , built in furnitures and all fittings and fixtures complete all as specified and as shown on drawings.Note for Sr. Item No. 1.01 to 1.09 above: (i) Boring of pile and cast-in-situ of pile including its concrete and reinforcement shall be measured and paid separately under relevant Schedule.(ii) Cost of pile cap including RCC, reinforcement and form work & its earthwork are included in the quoted amount of building. |
| 11 | Lumpsum price workedout by the tenderer for BUILDING& STRUCTURE WORKS as listed in Schedule ‘A’ Part-I(B) |
| 12 | Lumpsum price workedout by the tenderer for PILING WORKS as listed in Schedule ‘A’ Part-I(C) |
| 13 | Lumpsum price worked out by the bidder/ tenderer forSITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule \"A\" Part-II. |
| 14 | Lumpsum price worked out by the bidder/ tenderer forREFRIGERATION AND WATER COOLERas listed in Schedule \"A\" Part-III. |
| 15 | Lumpsum price worked out by the bidder/ tenderer forSOLAR WATER HEATER as listed in Schedule \"A\" Part-IV. |
| 16 | Lumpsum price worked out by the bidder/ tenderer for GEYSER as listed in Schedule \"A\" Part-V. |
| 17 | Lumpsum price worked out by the bidder/ tenderer for AIR CONDITION as listed in Schedule \"A\" Part-VI. |
| 18 | Lumpsum price worked out by the bidder/ tenderer for ROAD PATH AND CULVERTS as listed in Schedule \"A\" Part-VII. |
| 19 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLYas listed in Schedule \"A\" Part-VIII. |
| 20 | Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule \"A\" Part-IX. |
| 21 | Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule \"A\" Part-X. |
| 22 | Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGEas listed in Schedule \"A\" Part-XI. |
| 23 | Lumpsum price worked out by the bidder/ tenderer for FENCING AND GATES as listed in Schedule \"A\" Part-XII. |
| 24 | Lumpsum price worked out by the bidder/ tenderer forDG SET as listed in Schedule \"A\" Part-XIII. |
| 25 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule \"A\" Part-XIV. |
| 26 | Lumpsum price worked out by the bidder/ tenderer for SEWAGE TREATMENT PLANT as listed in Schedule \"A\" Part-XV. |
| 27 | Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule \"A\" Part-XVI. |
| 28 | Sch \"A\" Sec-XVII (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col. 5 siginifies this fact only. |
| 29 | Bringing approved earth (As approved by GE) from sources outside defence land including all costs such as royalty if any, transportation, taxes etc for area filling / forming including rising earth spreading in layers not exceeding 30 cm thick each layer watering and compaction with 8 tonne to 12 tonne power roller and finished to required size and shape etc up to any high / depth from existing ground level complete all as specified and directed.Note:(i) Earth required for this item shall be supplied by the contractor from outdide of the MOD land of any lead at his own cost and arrangement.(ii) All cost of procurement of earth including cost of transportation , royalties and tax shall deemed to be included in the quoted rate for this item.(iii) With reference to the clause 3.6 of SSR part II on serial page No. 21, it is clarified that measurement of this item shall be finished embankment / traverse of filled earth after consolidation / compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk.(iv) The total quantity or partial quantity of earth may not be available in Dinjan area. The contractor shall bring the earth from outside the Dinjan area. Therefore it is advised to contractor to check the availability of earth and its lead involved before quoting his rate against this item. |
| 30 | Supply, installation, testing and commissioning commercial type wall mounted electric chimney made out of 16 SWG (304) stainless steel with front turned down, angular frame work fully welded suitable for two Burner Indian Cooking Range 48\" x 24\" x 34\" & three Burner Indian Cooking Range 66\" x 24\" x 34\" including with the following items :-(i) Low height stock pot 24\" x 24\" x 24\" with Stainless Steel Hood (30\" x 30\" x 22\")(ii) Stainless Steel Hood 48\" x 30\" x 22\"(iii) Stainless Steel Hood 66\" x 30\" x 22\"(iv) Three Nos 18 Inches Heavy Duty Exhaust Fans of approved Make in MES above Stainless Steel Hood.(v) Electrical works such as point wiring with suitable size of wire, switch, socket outlet, ceiling rose, MCB DB etc of approved make in MES to be considered(vi) Transportation(vii) Stainless steel exhaust pipe covering |
| 31 | S&F stainless steel electric kitchen chimney 90 cm with 1500 cum/hr suction intelligent auto clean wall mounted, curved glass, baffle filter, motion sensor control, oil collector tray with inbuilt LED light including aluminium flexible pipe of 150 mm dia of suitable length with suction cover, with all accessories including making/ cutting hole of 150 mm dia suitable for aluminium exhaust pipe and making good the disturbed area completeall as specified and directed.(For Officers & JCO Mess) |
| 32 | Supply, installation, testing and commissioning of refrigerator, electric driven (single phase), capacity 210 Litres frost free, BEE 5 star rated, double door complete all as specified and directed. |
| 33 | Supply, installation, testing and commissioning of refrigerator, electric driven (single phase), capacity 308 Litres frost free, BEE 5 star rated, double door complete all as specified and directed. |
| 34 | Supply, installation, testing and commissioning of Valtage stablizer for automatic opration , single phase naturally air cooled indoor type and designed for input variation between 170 volts to 260 volts with output voltage stablizer at 230 volt with accuracy of + 2.5% and of capacity 3KVA complete all as specified and directed. |
| 35 | Supply, installation, connecting, testing and commissioning of Air conditioner Hi wall comprising of units Indoor & outdoor complete with cordless remote control unit, within built in airioniser, Plasma filter for better indoor air quality, leakage detector etc with minimum 5 star rating and EER 3.2 of capacity 2 TR, inclusive of suction and discharge lines of suitable sizeandnecessary brazing and providing nitrile tubing and wraping the ends with PVC insulating tape and mounting on suitable bracket, suitable drain pipe for disposal of wastewater upto ground level and testing, making good the disturbed surfaces of walls to match with the existing surfaces complete all as specified and directed. |
| 36 | Supply, installation, testing and commissioning of Valtage stablizer for automatic opration , single phase naturally air cooled indoor type and designed for input variation between 170 volts to 260 volts with output voltage stablizer at 230 volt with accuracy of + 2.5% and of capacity 4KVA complete all as specified and directed. |
| 37 | Supply, laying, connection and testing 100 mm bore, ductile iron pressure pipe with spigot and socket ends, class K-9 and confirming to IS 8329 - 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of black bitumen/blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and directed. |
| 38 | Supply, laying, connection and testing100 mm bore, ductile iron pressure pipewith spigot and socket ends, class K-7 and confirming to IS 8329 - 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of black bitumen/blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and directed. |
| 39 | M&L for Construction of brickmasonry valve pit of size 150 cm x 150 cm x 100 cm (internal dimensions) including concrete work with one brick thick wall in cement mortar (1:4) on 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded crushed stone aggregate)lean concrete, including PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10 mm thick cement plaster in CM (1:4) internally and externally upto 15 cm below ground level providing valve pit cover made out of 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150 mm long made out of flat iron 40x6 mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100 mm including provisionn of hinges welded with angle iron frame and MS cover of 3 mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 40 | Supplying, installing, testing and commissioning horizontal monoblock pump single stage, suction and delivery size 80 mm X 65 mm, discharge 8.3-13.8 litres per second at 17-26 Mtr head, 2900 RPM, 5 HP capacity suitable for working voltage 415 volts, 3 phase including MS channel, foundation etc complete all as specified and directed. (01 x working & 01 x Standby) |
| 41 | M&L for Fabrication, supply, installation, testing and commissioning electrical cubical control panel board an ISO 9001 factory assembled made In door type feeder pillar box weather and vermin proof fabricated of 3.15 mm CRCA MS sheet of suitable size, 3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB\"s including mounting measuring instrument such as Volt meter, Ammeter - 01 No, Selector switchs, CT\"s -03 Set, Phase indicator lamps, including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box complete all as specified and directed. |
| 42 | Serial item No. 2.013 continued....(Feeder piller box shall be consisting with the following)(Incoming) (a)MCCBFP 63 amps, 16 KA , 415 volts, 50Hz= 01 No(Outgoing) (a) MCBFP 32 amps.10 KA,415 volt,50 Hz = 02 Nos(centrifugalpump set )(b) MCB 40 amps(pump house bldg)(c) Supply & fixing arrangement of MN 16 DOL (cubical ) suitable for 05 HP centrifugalpump set = 02 Nos (d) Digital Panel mounted Amp meter 96 mm, square type with selector switch and with suitable size of CT\"s - 01 Set(e) Digital Panel mounted Volt meter 96 mm, square type with selector switch - 01 No (f)RYB indicating lamp, LED type - 01 set.(g) PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate. |
| 43 | Cutting existing 150 mm DI pipeline for 100 mm branch connection, insertion of tee of size 150/150 /100 mm jointing etc complete all as specified and directed.Note : Cost of earth work, DI specials and joints are included in quoted rate of this item. |
| 44 | S&F Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit , combi climate cable glands of IP 66 / 67 for cable entry and grommets IP 65 for conduit for cable exit, terminals as PVC connector heavy duty 32 Amps, 4 way for cable necessary fixing arrangements and with cable glands ,etc all as specified and directed. |
| 45 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 46 | M&L for Fabrication, supply, installation, testing and commissioning electrical cubical control panel boardan ISO: 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.0 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt AC 50 Hzduly painted with powder coatingwith locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB\"s including and mounting measuring instrument such as Volt meter, Ammeter,CT\"s, Phase indicator lampsincluding incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6 mm welded on all four corner embedded in PCC (1:2:4) using 20 mm graded crushed stone aggregate upto 30 cm complete all as specified and directed. (MAIN LT PENAL NEAR TFR )(Feeder pillar box shall be consisting with following)(a)4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support(Incoming )(a) MCCBFP 320 amps, 36 KA , 415 volts, Microprocessor release 50Hz= 01 No.(Outgoing)(b) MCCBFP 250 amps, 35/36 KA , 415 volts, Microprocessor release 50Hz= 02 No (W+S)(c) MCCBFP 63 amps, 35/36 KA , 415 volts (Existing pump house ) - 02 Nos |
| 47 | Serial item No. 2.017 continued....(d)Digital Panel mounted Amp meter 96 mm square typewith selector switch and suitable size of CT\"s - 01 Set(e)Digital Panel mounted Volt meter 96 mm square type with selector switch - 01 No.(f) Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.(g) RYB indicating lamp, LED type 01 set.(h) Drawing shall be approved by GE before placing the order. |
| 48 | M&L for Fabrication, supply, installation, testing and commissioning electrical cubical control panel boardan ISO: 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.15 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB\"s including and Mounting measuring instrument such as Volt meter, Ammeter , Selector switchs, CT\"s, Phase indicator lamps with holder , toggle switches and backelite fuse cut outs etc including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete all as specified and directed. (FP Box -I NEAR permanent staff bldg )(Feeder pillar box shall be consisting the following)(a)4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support |
| 49 | Serial item No. 2.018 continued....(Incoming)(a)MCCBFP 250 amps, 36 KA , 415 volts, Microprocessor release 50Hz = 01 No(Outgoing) (a)MCCBFP 125 amps, 16 KA , 415 volts, Fixed & thermal magnetic release 50Hz = 01 No (FP NO 02 NEAR OR BLOCK) (b)MCCBFP100 amps, 16 KA , 415 volts, Fixed & thermal magnetic release 50Hz = 01 No (ADM BLOCK) (c)MCCB FP 63 amps, 16 KA , 01 No (JCO BLOCK) (d) MCCB FP 32 amps, 16 KA , 01 No (permanent staff bldg )) (e)MCCB FP 32 amps, 16 KA , 03 Nos (RECREATION ROOM BLDG, street light & SPARE) (f)Digital Panel mounted Amp meter 96 mm square type with selector switch and suitable size of CT\"s - 01 Set(g) Digital Panel mounted Volt meter 96 mm square type with selector switch - 01 No (h)Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.(j) RYB indicating lamp, LED type 01 set. |
| 50 | M&L for Fabrication, supply, installation, testing and commissioning electrical cubical control panel boardan ISO: 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.15 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB\"s including and Mounting measuring instrument such as Volt meter, Ammeter , Selector switchs, CT\"s, Phase indicator lamps with holder , toggle switches and backelite fuse cut outs etc including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete all as specified and directed. (FP Box -II NEAR OR BLOCK B)( Feeder pillar box shall be consisting the following)(a)4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated of 1 ½ times of the incoming capacity with provision of extension and mounting on porcelain support |
| 51 | Serial item No. 2.019 continued....(Incoming)(a) MCCBFP 125 amps, 16 KA , 415 volts, Fixed & thermal magnetic release 50Hz = 01 Nos(Outgoing)(a)MCCB FP 63 amps, 16 KA , 02 Nos (OR BLOCK A & B) (b)MCCB FP 63 amps, 16 KA, 01 Nos ( OR MESS)(c)MCCB FP 32 amps, 16 KA , 02 Nos (Himast Light & spare)(d) Digital Panel mounted Amp meter 96 mm square type complete with selector switch complete with suitable size of CT\"s - 01 Set(e)Digital Panel mounted Volt meter 96 mm square type with selector switch - 01 No (f)Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.(g) RYB indicating lamp, LED type 01 set. |
| 52 | S&F DWCPE (SN8) pipe 160 mm outer dia and 150 mm inner dia laid , jointed and tested as per manufacturer\"s instruction complete all as specified and directed. |
| 53 | Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 12 KW (15 KVA),415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tankwith mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Dinjan, Assam (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB-IV guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection, 3 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 12 KW(15 KVA) atoutdoor atmospheric conditions at Dinjan, Assam (Taking all derating factor into consideration),12/24 Volt (as per manufacturer recommendations) electric battery start incl suitable size battery, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc . |
| 54 | Serial item No. 2.021 continued....(ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 12 KW(15 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \"H\", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.(iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition(v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M(vi) Diesel storage tank of capacity adequate for storage of diesel as per manufacturer specification.(vii) AMF Panel: -Microprocessor / Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum bas bar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete.(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW,frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d)All standard relays, circuitsand protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(ix) First fill of Lubricants, Coolant & Fuel: -First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn. |
| 55 | Serial item No. 2.021 continued....Note: PCC foundation for DG Setshall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(d) One set of latest Spare part catalogue with price, exploded view of parts and user\"s manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer\"s drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level |
| 56 | Design, Supply, Installation, Testing and commissioning incl comprehensive maint for 5 years of Roof Top Solar Power Generation Plant of capacity 50 KW (minimum 60 KWp) (AC) at output Voltage 415 Volt, 50Hz, on grid connected complete with structure and foundation comprises Design and construction of foundation, civil supporting structure, modules, inverters, DC junction, Distribution & combiner boxes, AC junction & combiner boxes,lighting arrester, weather station, SCADA system, earthing, connecting wires / cables with all accessories required for SPV complete all as per MNRE/SECI specifications and technical specifications asAnnexure-I (Design Brief Report and Technical Specification for SPV Plant) complete all as specified and directed |
| 57 | S&Fpush cock (PRS-073, 1.5 LMP) for urinal for 15 mm bore iron pipe complete all as specified and directed. |
| 58 | S&F brass chromium plated health faucet with health faucet tube of 1.20 m long and standard accessories suitable for 15 mm bore pipe for WC complete all as specified and directed. |
| 59 | S&F two way bib cock with wall flange quarter turn (Low flow) 16 mm dia complete all as specified and directed. |
| 60 | Design, Construction, Supply, installation, testing and commissioning of compact & concealed designed Sewage Treatment Plant of capacity 20 KLD based on Moving Media Bio Reactor (MBBR) / MBR / SBR / SBT / Johkasou technology or any other Technology all as per DBR including fully automation system (Scada System), modular Pre- constructed systems having sedimentation and separation chamber, anaerobic contact media chamber, moving bed chamber (Aerobic), sedimentation chamber, disinfectant chamber and tertiary treatment plant, including operation and maintenance for a period of 5 years from the date of completion of work including all consumable except power, with adequate manpower to ensure no downtime of plant and provide consistent outlet parameters, the plant shall be having least energy and operating cost and No noise during operation all as per DBR mentioned in particular specificaton complete all as specified and directed. |
| 61 | Supplying, installing, testing and commissioning horizontal monoblock pump single stage, suction and delivery size 80 mm x 65 mm, discharge 17.9 litres per second at 28 m head, 5 HP capacity suitable for working voltage 415 volts, 3 phase complete all as specified and as directed.( 01 X working & 01 X standby) |
| 62 | S&F brass sprinkler water irrigation sprayer head of size 1 inch complete all as specified and directed. |
| 63 | S&F of Modular type 3 pin 20 A Socket with SP MCB 1 No, conforming to IS 1293 : 2005all as specified in IS 732 : 2019 complete all as specified and directed. (for AC & Geyser Point) |
| 64 | Supply, Installation, testing & commissioning of LED Engagement light fitting (Red & Green),220 V, luminaire made of CRCA housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed system lumens at a system efficacy of at-least 100 lumen/watt. Power consumption should not be more than 10W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum2 KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 compliant. The luminaire driver shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The Contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. Contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and directed. |
| 65 | S&F Surge Protection Device (SPD) single phase and neutral, T2 -limb, Imax 20 KA per pole fixed in distribution board and making connections complete all as specified and directed. |
| 66 | S&F Surge Protection Device (SPD) Three phase and neutral, T2 -limb, Imax 20 KA per pole fixed in distribution board and making connections complete all as specified and directed. |
| 67 | S&F Modular Telephone socket RJ 11 suitable for housing modular frame plate complete all as specifiedand directed. |
| 68 | S&F modular type TV socket. RJ46, 1 module complete all as specified and directed. |
| 69 | Boring for bored cast-in-situ piles 450 mm dia. in any type of soil using DMC (Direct Mud Circulation) method of boring and getting out and disposal of spoil out side MD land complete all as specified and as shown on drawings and as directed. |
| 70 | M&L for Reinforced cement concrete (design mix) M-30 grade as in Cast-in-situ piles complete all as specified and as directed. Note: Pile shall be casted as mentioned in drawings. However, for payment purpose the length of pile shall be measured from the bottom of pile to cut off level only. The unit rate quoted shall be deemed to included this aspect. |
| 71 | Carrying out initial pile load tests for 450 mm dia pile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed. |
| 72 | Conducting low strain integrity test on 450 mm diameter RCC cast-in-citu piles, data analysis and submission of report. (min 10 piles per visit) complete all as specified and directed. |
| 73 | Carrying out routine pile load tests for 450 mm diapile as per IS: 2911- Part 4 with carrying out necessary calibrated measuring devices like load/pressure guage, hydraulic jack, dial gauges and magnetic stands, submitting all the test reports to GE with proper presentation complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail