| 1 | Demolition of Concrete of any description (unreinforced) and in any position, complete all as specified and directed. |
| 2 | M&L for 75mm thick levelling course in cement concrete type B-1 (1:2:4) using 20mm graded aggregate as in floor, complete all as specified and directed. |
| 3 | M&L for 25mm thick cement concrete type B-0, 1:2:4 (using 12.5mm graded aggregate) as in floor complete all as specified and as directed |
| 4 | M&LPCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in padding over roof slab for providing proper slope 1:40and approx thickness 50mm or lessand finished the surfaces even and smooth wihtout unsing extra cement complete all as specified and directed. |
| 5 | M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like fixed in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 6 | M&L machine cut Kota stone 18 to 20 mm thick laid, jointed with grey cement slurry and pointed with coloured cement to match the shade of Kota stone as in floor etc including rubbing and polishing laid over and including screed bed 20mm thick in CM 1:6 complete all as specified and directed. |
| 7 | All as per item No. 6 but in vertical/dado in CM 1:4 complete all as specified and directed. |
| 8 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, Fe-410-W Gde E-250 of quality \"A\", complete all as specified and directed. |
| 9 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed |
| 10 | M&L for brick work in cement mortar 1:6 of fly ash bricks straight or curved on plan exceeding 6mtr mean radius, complete all as specified and directed. |
| 11 | M&L for Brick work with fly ash bricks, straight or curved on plan to anyradius in half brick thick walls built in CM 1:4, complete all as specified & directed. |
| 12 | M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces on brick work or concrete surfaces finishing the surfaces even & smooth without using extra cement including scaffolding upto any height and curing the surface, complete all as specified and directed. |
| 13 | M&L for Rendering 10mm thick in cement mortar 1:6 on other fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement and curing the surface, complete all as specified and directed. |
| 14 | M&L for rendering 5mm thick on cement mortar in CM 1:3in RCC roof slab, facia or edging of chajjas, ceiling and roof projectionmaking the line in true shapefinished even & smooth without using extra cement, complete all as specified and directed. |
| 15 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) not exceeding 1.50 Sqm each including taking out hold fast embedded in PCC, complete all as specified and directed. |
| 16 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 Sqm and n.exc 4 Sqm each including taking out hold fast embedded in PCC, complete all as specified and directed. |
| 17 | S & FMild steel, thickness of sheet 1.25mm plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 18 | S & F 3 ways sliding anodized aluminium glazed window shutter with frame & with following specifications all as specified & directed:-(a) window frame 3 track of size 95mmx25mmx1.5mm thick(b) Stiles and rails of size 35mmx25mmx1.5mm(c) 35mmx35mmx1.5mm T section mullion(d) PVC gasket with 4mm thick tinted glass, incl aluminium handles with necessary locking arrangement for 02 Nos glazed shutter.(e) Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples incl aluminium handles with necessary locking arrangement for 01 Nos gauzed shutter.Note:- Measurement to be taken as overall width and height of window. No shutter or frame to be measured separately. All necessary accessories including tinted glass and stainless steel wire cloth required for assembling and fixing window at proper place complete are deemed to be inclusive. |
| 19 | M&L Preparing the new steel surfaces of any description over 10cm width or girth priming with red oxide zinc chrome and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 20 | S&F machine pressed precast concrete interlocking paver blocks with grey cement and pigment, any shape and size conforming to IS 15658:2006 of 60 mm thickness M35 grade including 25 mm thick sand cushioning complete all as specified and directed. |
| 21 | M&L for 75mm thick PCC (1:3:6) type C1 using 20mm graded crushed stone aggregate as in floors, including finishing the surfaces even and fair, complete all as specified and directed. |
| 22 | S & F Anodised designer grill of 7mm dia fixed with and including flat section of size 50x1.5mm fixed to aluminium window complete all as specified and directed. |
| 23 | M&L for preparation of surfaces by leveling/edging of the disturbed planes/edges of New plastered surfaces of wall by using wall care putty of avg 1 mm thick on vertical surfaces to true vertical and horizontal lines of bricks/concrete walls finish to even and smooth with two layersof screylie wall care putty with two coats of oil bound distemper over one coat ofprimer as on walls surfaces complete all as specifiedand directedcomplete all as specified and as directed. |
| 24 | M&L for newly plastered surfaces of ceiling incl, cornicesand applying two coats ofdistemper oil emulsion incld a coat of primeron ceiling all as spd and directed. |
| 25 | Preparation of new plastered surfaces of walls and Materials & Labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/L and UC resistance as per IS 15489:2004 alkali and fungal resistance, dust resistance, water repellant, crack-bridging, weather proof 1st quality exterior paint of required shade with silicon additives @ 1.43L/10 Sqm and including priming coat of exterior primer applied @ 0.90L/10 Sqm and scaffolding at any height complete all as specified and directed by Engr-in-Charge. Note : - Tint/Shade shall be approved by Engr-in-Charge. |
| 26 | M&L liquid water proofing treatment to RCC roof slab incld dismantling of existing treatment of any description in following procedure : (a) Laying 10mm thick rendering in Cement mortar 1:4 mixed with WPC 3% by weight of cement onfair faces of concreteroof surfaces , finished even and fair to receive treatment on roof Complete (b) Applying first coat fiber reinforced elastometic liquid water proofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with sun reflective index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9 Mpa and shall have reack bridging ability upto 2.5mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree celsius with 3.3% dilution as priming coat (c) laying of fiber mesh 0.3mm thickness weave in leno pattern having weight 4.5 gm/ Sqm and pasting it properly with overlap of 50mm and allow it to dry (d) Applying second coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge (e) Applying third and final coat undiluted @ 0.45 ltr/ sqm as directed by Engr-in-Charge. (The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster). |
| 27 | M&L for Non abrasive paving (rectified endura) cement concrete coloured tiles 300x300mmx10mm thick set jointed and pointed in neat cement slurry mixed with pigment laid over 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed. |
| 28 | All as per item No. 27 but in vertical/dado in 10 mm thick CM 1:4 complete all as specified and directed. |
| 29 | Rounding to edges of stone slabs, one edge, such as in steps, cooking platform and other similar situation, complete all as specified and directed. |
| 30 | M&L for Mild steel TMT bars 5mm dia and over cut to length bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 31 | M&L forReinforced cement concrete (nominal mix), type B-1 1:2:4 (20 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 32 | M&L for Reinforced cement concrete (nominal mix), type B-1 1:2:4 (20 mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 33 | M&L for broken stone or boulder hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed. |
| 34 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girdersl, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floor and beamsetc., complete all as specified and directed. |
| 35 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), complete all as specified and directed. |
| 36 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified & directed. |
| 37 | M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 38 | Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. |