| 1 | M&L for alignment of longitudinal square bar 40x40mm size and cross travel square bar 40x 40mm sizeof 5 TON EOT Crane inside AF Tech area at 7 metreheightfrom ground level by removing all square bars and grinding , welding including providing necessary accessories / spares such as bolts , nuts ,reail clamps of required Nos, rubber packing etc and refixing in its original position and testing for noise free and smooth functioning of LT and CT motion complete all s specified and as directed. |
| 2 | M&L for removing the unserviceable steel wire rope 16 Sqmm thick structureof EOT crane of 5.0 Ton capacity and S&F new steel wire rope 16 Sqmm thick structureof similar make any type complete all as specified and as directed. |
| 3 | M&L for welding work of LT Drive shaft supports bearing block backet of 5 TON EOT craneinside AF area complete all as specified and as directed. |
| 4 | M&L for shifting of controlpanel mounted on the end trolley to crane service platform for the safety during electrical maintenance all as recommended by Electrical Inspector complete all as specified and as directed. |
| 5 | M&L forPVC junction of size 2 feet x 2 feet for for shifting ofcontrol panel end trolley mounted complete all as specified and and as directed. |
| 6 | M&L for comprehensive maintenance of electrically operated passenger lifts installed at 23 ED HQ Building atAF Station ,lift in reliable safe and efficient operating condition through MoU with OEM (Make of Lift - TKElevator India Pvt Ltd) by regularly examining, lubricting and adjusting the equipments and carry out planned maintenance (Monthly, Quaterly, Halfyearly and yearly) in systematic and controlled manner using techniques and expertise and replacement of all unserviceable components as covered in AMC, suitable for serving Ground+ Three floors i.e. total Four landings with electric power operated steel sliding doors installed complete all as specified and directed for the following lifts:- 23 ED HQ building atAF Station- Capacity of 08 Passanger lifts - 01 No |
| 7 | Notes for item No. 06 :-(a) Type of AMC category - Platinum type(b) The comprehensive maintenance shall be done throuhg OEM i.e. of M/s TK Elevator India Pvt Ltd. The lowest bidder shall submit theMoU fromM/s TKElevator India Pvt Ltd. as per standard proformawithin 10 days from the date of opening of financial bid failing whichbidwillbe rejectedin financialevaluation and bid will not be accepted . (c) The maintenanceincluded for repair, replacement of machines, motors, generators, ropes, inverter/ ARD system, controller parts, PCBs, belts, rollers, gears, bearings, solenoids, coils, chock break shoes, liners, contactors, relays, push bottons, coils, door operator VVF drive, VVVF main drive, car door, safety device limit switches, emergency alaram system with hooter,governor, hoistway door locks,magnetic switches,magnets,door motor,door drive,encoder,car door safety device, Infrared screen, governors, interlock on hoistway doors, gear oil,travelling cable, indicators, LED display boards and minor mechanical spare parts. The rate of above spares shalldeemed to be included in the rates quoted by the contractor. (d) Contractor shallconclude an AMC with OEM and copy of the agreement along with invoice will be submitted to Engineer-in-Charge and GE before commencement of work .(e) The above comprehensive maintenance shallinclude complete maintenance of existing lift by regularly and systematically examining adjusting fabricating as and when required for smooth and efficient functioning of the equipment/lift. |
| 8 | (f) Contractor shallprominently display his contact MobileNo and OEM contact No insideand outside the lift on each lift(g) All existing earthing of the lifts shall be maintained and made fully functional by the contractor to the entire satisfaction of the Engineer-in-Charge. (h)The OEM shall detail one technician staff to inspect the lift every week regarding functioning of lifts or any other issues arising in the lift. The problem noticed if any to be informed immediately to JE E/M / Engineer-in-Charge. OEM Technician should laways carry service tools during the site visit.(j) Contractor or his rep shall visitthe sitewithin two hours of break downnotification of lift . In case the contractor or his rep shall not come to the site of attending breakdown within two hours, a penalty of Rs 1000 per fault per day shall be imposed over contractor and shall be deduct from his due payment. |
| 9 | S&F 300mm sweep car cabin fan in lift with necessary accessories such as fins/ grills, nuts, bolts and wires, etc.including taking down old unserviceable fan complete all as specified and directed. |
| 10 | M&L for buffing for stainless stell surface inside of lift car cabin complete with using buffing machine and compound for buffing upto remove the dull outlook and rusted spots on steel surface complete all as specified and directed. |
| 11 | S&F in repairs sealed maintenance free battries of 18 AH capacity of 12 Volts for suitable in ARD system complete all as specified and directed. (Make:- Exide/ Amaron/ HBL/Amco) |
| 12 | M&L for inspection, checking, cleaning and testing of fire alarm system 10 Zone window type complete including fire alarm panel, manual call box, hooter,wiring etc. work portion of technical buildingsthrough trained /experianced technician of OEM complete all as specified and directed. Notes :- (a) Fire Alarm control panel:- Itshall be kept clean by checking for its controls, indicating equipment’s system and all operations / fault indicators including checking of panel circuits for its healthiness and including of healthy battery/UPS/battery charger system. (b) Detectors,Manual Call Point and Hooter:All items which are installed at technical buildingsshall be tested by actuating the particular detectors every quaterlyto ensure proper functioning of system. (c) Testing equipment shall beprovided by the contractor and quoted rate shalldeemed to be includedfor the same . (d) Making necessary arrangements of scaffaolding/ laddersetc and quoted rate shalldeemed to be includedfor the same .(e) Spares /items(i.e manual call box,hooters,Detectors, wiringand battery) shallbe measured and paid separately under relevant items .(f) Any damage to fire alaram system during maintenance shall be repaired and rectified by the contractor at his own cost.(g)Quarterly inspectionshall be carried out and testreport will be submitted to Engineer-in-Chargeduly signed by users rep. |
| 13 | M&L for replacement ofmulti-stranded copper conductor cable 2.5 Sqmm nominal cross-sectional area, three core, PVC insulated and unsheathedFRLS cable 1100 volts grade for wiring fixed on wall/ceiling/roof trusses with suitable dia steel/pvc conduit pipe complete with thimbles and ferrules as required complete all as specified and directed. |
| 14 | M&L for repair and rectification offaults occurs inFire Alaram panel addressable type multi sensor and detectors with connected accessoriescomplete all as specified and direted. |
| 15 | S&F in replacement of detectorscomplying with and type certified to EN - 45 Addressable type smoke detector Photo electric /Optical with base with self built intelligence as per IS: 11360 with connected and fixing accessories completeincluding taking down the unserviceable smoke detector with accessories all as specified and as directed. |
| 16 | S&F in replacement of detectors complying with and type certified to EN - 45 Addressable type multisensor detector with heat and smoke combinationPhotoelectric /Optical with base with self built intelligence as per IS: 11360 with connected and fixing accessories completeincluding taking down the unserviceable multisensor detector with accessories all as specified and as directed. |
| 17 | S&F inreplacement of detectors complying with and type certified to EN - 45 Addressable type heat detector with base with rate of rise cum fixed temperature as per lS:2175 Photoelectric /Optical with base with self built intelligence as per IS: 11360 with connected and fixing accessories completeincluding taking down unserviceable heat detector with accessories all as specified and as directed. |
| 18 | S&F in replacement of sealed maintenance free battries of 12 volts 7 AH capacity for fire alaram panels, capable of running min of 4 hours back up complete all as specified and directed. |
| 19 | S&F in replacement of flush mounted 16 gauge MS sheet Manual Call Box with micro switch with transparent hinged vandal resistanat cover,red colour complete all as specified and directed. |
| 20 | S&F in replacement of wall mounted speaker (electronic hooter) in acoustically treated box with 4 watt speaker, Hi-Intensive sound (80 to 100 db), Colour Red complete all as specified and directed. |
| 21 | M&L for complete servicingafter disconnecting electrical connections of fire fighting jocky pumpmotor pumpset and decoupling the pump and motor, suction and delivery pipe, transporting Motorpump setto work shop. Deassemble the pump set, removing, replacing the worn out bushes / bearing service the pump set complete, andremoving pump shaft repair by lathe work for proper alignment, replace thurst bearing, impellar, brass bush, CI bowl assembley, rubber coupling,washers, nuts and boltswith one coat of primer & two coat of synthetic enamel paint after scraping the body surface of pump with emery paper,writing letters,assemble the motor pumpset,transporting to site, coupling, connecting electrical & pipe connections includingtesting complete for 180 LPM capacity, 70 Mtr headall as specified and directed.Note :- Spare part such as bearing, bush , oil, grease lathe work if required etc shallbe provided by the contractor and quoted rate shall be inclusive for above . |
| 22 | M&L for complete servicing bydisconnecting electrical connections of main electrical driven centrifugal fire pump motor pumpsethaving capacity 2280 LPM, 70 metrehead and dischrge pressure 3.5 Kg / Sqcm and decoupling the pump and motor, suction and delivery pipe, transporting Motorpump setto work shop ,deassemble the pump set, removing, replacing the worn out bushes / bearing service the pump set complete, andremoving pump shaft repair by lathe work for proper alignment, replace thurst bearing, impellar, brass bush, CI bowl assembley, rubber coupling,washers, nuts and boltswith one coat of primer & two coats of synthetic enamel paint after scraping the body surface of pump with emery paper,writing letters,assemble the motor pumpset ,transporting to site coupling, connecting electrical & pipe connections includingtesting completeall as specified and directed.Note :- Spare part such as bearing, bush , oil, grease lathe work if required etc shallbe provided by the contractor and quoted rate shall be inclusive for above . |
| 23 | M&L for carrying out \"B\" check for fire fighting deisel Engine and pump having capacity ,2280LPM , 70 metre head and discharge capacity3.5Kg/ Sqcm as per Manufacturer\"s recommendation including replacement of necessary spares and filters such as fuel filter, Air filter , SLO Bypass filter and lub oil filter complete including rectification of minor defects and accessories like nuts, nbolts, O rings etc cleaning of radiatior and coolant tank with air blower, drain out old engine oiland coolant andreplace with new engine oil and coolantas per existing grade & coolant and tuning of engine all as speficied and as directed by Enginner in Charge. |
| 24 | S&F in replacement of tubular battery 12v, 180Ah capacity with connecting up and testing complete; including taking down existing unserviceable Battery , all as specified and as directed. Make : Luminous,Amaron, Exide |
| 25 | M&L forrepair / maintenance ofcentrifugal pumps motor electric drivenfor 60HP capacity and dismantling and openingcomplete motor under mention cap and segrigated all serviceable parts and kept at site for reuse includingrewinding motor with supper enamled wire of suitable gauge complete , and replacing bushes, bearing, check nut, and other required partsand varnishing the same includingpainting of motor and making the motor functionable includingservicing, cleaning,greasing, overhauling, re-alignment with lock,key,nut, bolts,washers and reassembling the same andtesting completeall as specified anddirected by Engineer-in-Charge. |
| 26 | M&L for detecting leakage in MS/ ERWpipe of fire fighting system line 150mm dia in any location , any depth including necessary earth work excavation andreparing and arresting the leakagesby providing necessary welding work at site complete all as specified and as directed. Note :- Flange / Collarpiece as required for rectification work shallincluded in the quoted rate and nohingextra shallbe paid to the contractor. |
| 27 | M&L for detecting leakage in MS/ ERWpipe of fire fighting system line100/80 mm dia in any location , any depth including necessary earth work excavation andreparing and arresting the leakagesby providing necessary welding work at site complete all as specified and as directed. Note :- Flange / Collarpiece as required for rectification work shallincluded in the quoted rate and nohingextra shallbe paid to the contractor. |
| 28 | M&L for earthingcomplete with copperearth plate electrodeof size 60cmx60cmx3.15mm thick buried in ground vertical to a depth not less than 2.25 metredeep below ground level with top edge of plate not less than 1.5 metrebelow normal ground level connected to copper strip of size 20mm x 3.0 mm thickand 40 mm dia bore, 7.5 mlong, light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth platefixed with deep cut onone end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 type B1 of size 300 X 300 X 300 mmand 150 mm alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- Earth plate shall be fixed with welded joints. |
| 29 | Supply andlaying and welding MS (ERW) pipe100mm nominal dia conforming to IS. 1239 (Heavy grade) in trenches/ on wall / roof / surface complete with fittings/ flanges including applying anti corrosive treatment, (wrapping of two layers of 2 mm thick multi-layer anticorrosive polymeric mix tape applied over a coat of primer) and testing complete all as specified |
| 30 | All as per item No 27 above but for 150mm dia |
| 31 | M&L for replacement of RRL Hose pipe 63mm dia , 15 mtr long having male and female coupling conforming to IS 903 complete all as specified and as directed. |
| 32 | M&L for painting of MS/ERW fire fighting pipe upto 100mm dia byscrapping out the old faded paint and applyingtwo coats of red oxide paint complete all as specified and as directed. |
| 33 | M&L for painting of MS/ERW fire fighting pipe 150mm dia byscrapping out the old faded paint and applyingtwo coats of red oxide paint complete all as specified and as directed. |
| 34 | S&F in replacement ofsuction strainer ball type thread/ flanged type 150 mmdia including providing new leather sheet by dismantling and taking up existing unserviceable old foot valveas per site requirement complete all as specified and directed . |
| 35 | S&Fin replacement of 80mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set all as specified. |
| 36 | S&F inreplacement of sluice valve flanged & drilled holes type of size 150mm bore with high tensileS/S spindle duly ISI marked class PN 1.6with jointing material and nut, bolt, washer complete including dismandling of oldsluice valve complateall as specified and directed. |
| 37 | S&F inreplacement of sluice valve flanged & drilled holes type of size 80mm bore with high tensileS/S spindle duly ISI marked class PN 1.6with jointing material and nut, bolt, washer complete including dismandling of oldsluice valve complateall as specified and directed. |
| 38 | S&F inreplacement of cast iron flanged,non return valves,80mm dia ,swing check type of PN 1.6 rating , conforming to relevant IS specifications andproviding and fixing nuts, bolts, washers, gaskets etc. complete as required. (for electric and diesel pump). |
| 39 | S&F in replacement of 150mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set all as specified and directed. |
| 40 | S&F in replacementof single headed hydrants 80mm dia, 1.5 metreheight , flanged inlet with 63mm female instantaneous outlet of gun metal complete with blank caps, chain conforming to IS 5290-1977 and ISI marked. (For yard hydrant) |
| 41 | S&F in replacement old rusted hose box suitable for hose reel of size 20 mm , 30 meter length complete with coupling branch pipe and nozzle , MS sheet 2 mm thickness complete all as specified and as directed. |
| 42 | S&F inreplacement of fire hydrant landing valve 80mm dia, flanged inlet with 63mm female instantaneous outlet of gun metal complete with blank caps, chain conforming to IS 5290-1977 and ISI marked. (6 Nos for yard hydrant and 11 Nos for wet riser system) |
| 43 | S&Fin replacement of Gun metal branch pipe 63mm dia and 12.5 mmnozzle conforming to IS specifications complete all as specified. |
| 44 | Excavation in trenches not exceeding 1.5 mwide andnot exceeding 1.5 min depth for laying of CI/GI water tubing and getting out in any type of soil complete all as specified and directed. |
| 45 | Removing excavated material (soil) to a distancenot exceeding50m and depositing where directed at a level not exceeding 1.5 mabove the starting point completed all as specified and directed. |
| 46 | Returning filling insoil including spreading, levelling, watering and well ramming in layers not exceeding 25cm completed all as specified and directed. General Notes:- The tenderer shall visit the site of work with prior permission of GE and ascertain the actual make model of plant/ equipmentsand conditions of the plants and scope of work. Make and size of items shall be provided by the contractor as perexisting . |