| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), terrazzo dado/wall tiling and skirting etc on brick or stone walls etc including racking out joints hacking for key and scrubbing and removing rubbish off the premises complete all as specified |
| 2 | Demolition of cement concrete in ground floors and any description and in any position not otherwise specifically provided for (thickness of tiles and screed bed measured as PCC) etc and rubbish off the premises all as specified and directed |
| 3 | M&L for vitrified ceramic tiles 10 mm thick (Square/rectangular) light shade polished area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc in floors set and jointed in neat cement slurry and pointed in coloured cement to match, 15mm thick screed bed or bedding layer CM 1:4 for laying finishes complete all as specified |
| 4 | All as per Srl item No 3 here-in-before but in skirting over 10 mm thick backing coat in CM 1:4 as specified and directed |
| 5 | S&F Glazed ceramic coloured tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 15 mm thick rendering in CM 1:4on other than fair face of brick work complete all as specified and directed |
| 6 | M&L for Granite (of any type) work 12 to 15 mm thick (table rubbed and polished) in floor, jambs, pillars, door /window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified |
| 7 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified |
| 8 | M&L for 25mm thick PCC 1:2:4 type B0 (12.5mm graded aggregate) with WPC under floor complete all as specified and directed |
| 9 | Taking downchowkats or frames not exc 1.5 sqm each with shutters (without taking of shutters from the frames) incl making good disturbed surfaces of wall matching adjoining wall finish and removing taken down material from site complete all as specified and directed. |
| 10 | Taking downchowkats or frames exc 1.5 sqm but not exc 4.00 Sqm each with shutters (without taking of shutters from the frames) incl making good disturbed surfaces of wall matching adjoining wall finish and removing taken down material from site complete all as specified and directed. |
| 11 | S&F factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid in supply only rates separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 12 | S&F factory made uPVC white colour Two track two panels sliding window above 1.5m height made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension.(Area of window above 2.5 sqm upto 4.00 sqm)comprising of uPVC multichambered frame, with in built roller trac and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanised mild steel section made from roll forming process of required length (shape & size according to uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel alongwith zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), GI fasteners 100 x8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid in supply only rates separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made |
| 13 | Supply only toughened glass 6 mm thick to required size shape to be fixed in UPVC window complete all as specified and directed by Engr-in-Charge |
| 14 | Supply only Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm to be fixed in UPVC window complete all as specified and directed by Engr-in-Charge |
| 15 | M&L for providing and fixing stainless steel (Grade 304) in Window Grill made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the Grill with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size as specified and directed by Engr-in-Charge |
| 16 | Dismantling of brick work built in cement mortar of any description complete all as specified and directed by Engineer-in-Charge |
| 17 | M&L for old size brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius wall built in cement mortar 1:6 complete all as specified |
| 18 | All as per Srl item No 17 here-in-before but except bricks |
| 19 | M&L for rendering 12mm thick in cement mortar1:6 on other than fare face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified |
| 20 | M&L for preparation of newly plastered or unplastered surfaces of wall /ceiling and applying two coat of distemper oil emulsion white/tinted over a coat of wall care putty finished even and smooth surface by hand roller complete all as specified and directed by Engr-in-Charge |
| 21 | S&F of metallic fibre acoustical suspended ceiling system with Mina Tuff (Micro look) edge tiles with silhouette exposed grid.The tiles should have humidity resistance (RH) of 99%, NRC upto 0.6, light reflectance 88%, Thermal conductivity K=0.052-0.057 w/m K, colour white, fire performance class-I (BS476 part 6 & 7) in module size of 600 x600 x16mm with bio block coating on the face of the tile, impact resistant and suitable for green building application, with recycled content of 63%.The tile shall be laid on silhouette profile grid system with 15mm white/block colour and with a web height of 38mm and load carrying capacity of minimum 11.68 Kgs/Sqm, Silhouette, main runner & cross tees to have mitred ends & \"Birdsmouth\" notches to provided mitred cruciform junction complete all as specified and directed.Make : Armstorng, Saint Gobain |
| 22 | S&F hollow PVC wall lining interlocking type 7mm thick plain/coloured/wood grain fitted in tot the wall with PVC rawl plug and steel screws including fillets on joints as per manufacturers instruction etc complete all as specified and directed by Engr-in-Charge.Note : If any minor electric fittings and fixtures disturbed there will be match and fixed as existing |
| 23 | S&F Aluminium powder coated/colour anodised (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc completed all as specified |
| 24 | S&F Anodised aluminium powder coated door shutters (minimum thickness of powder coating 50 micron) aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified |
| 25 | S&F of 5mm thick tinted glass ordinary quality exc 0.50 sqm in each pane all as specified. |
| 26 | S&F of door closer hydraulically regulated aluminium (dia cast) body designation No 3 universal type suitable for door shutter of weight between 61 to 80Kg of approved make having ISI mark all as specified. |
| 27 | S&F aluminium anodised tower bolt 200mm long and fixed all as specified. |
| 28 | S&F aluminium door lock 7 lever vertical type brass body 100mm long with duplicate key all as specified. Make : Godrej |
| 29 | S&F 12 mm thick toughened glass as in SS pivot hinge doors, hinged doors, partitions, partitionsautomatic doors and similar work including cutting to shape, drilling holes required, complete all as directed by Engr-in-Charge |
| 30 | M&L for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as directed |
| 31 | S&F stainless steel D type handle of size 300 mm long for toughened glass door complete all as specified |
| 32 | S&F SS glass door patch lock fixed to door with triplicate key complete all as specified. Make : Godrej |
| 33 | Demolition of reinforced cement concrete Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified. |
| 34 | Excavating over areas n.exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified |
| 35 | M&L for PCC 1:4:8 type D2 (using 40mm graded aggregate)in foundation, filling and mass concrete complete all as specified |
| 36 | M&L for RCC M-30 (20mm graded aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified |
| 37 | M&L for RCC M-30 (20mm graded aggregate) in Columns, pillars, piers, posts and struts complete all as specified |
| 38 | M&L for RCC M-30 (20mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified |
| 39 | M&L for RCC M-30 in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified |
| 40 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rough finished surfaces of concrete complete all as specified |
| 41 | Formwork to sides of pillars, posts, struts, piers, column and stanchions, Square, rectangular or polygonal rough finished surfaces of concrete complete all as specified |
| 42 | Form work tosides and soffits of floor or roof beam, beam, hauchings, girders, bressumemers, lintels, cantilevers, shelves incl supports overhangs etc also splays between floors and beams, flat, rough finished surfaces of concrete complete all as specified |
| 43 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified |
| 44 | S&F MS TMT Bars of 10 mm dia and over, cut to length, bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clip all as specified. |
| 45 | M&L for 100mm thick PCC 1:4:8 type D-2 (using 40 mm graded aggregate), as in flooring, sub base etc complete all as specified. |
| 46 | M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded aggregate), as in flooring complete all as specified. |
| 47 | M&L for rendering 10 mm thick in cement plaster 1:3 on ceiling finished even and smooth without using extra cement complete all as specified |
| 48 | M&L for complete removal of existing treatment of old decorated surfaces of wall by mechanical sander/ brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and filling in depressions to make smooth surface and finishing walls with Acrylic smooth exterior paint of required shade : New work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified. |
| 49 | M&L for preparation of old painted surfaces applying one coat of synthetic enamel paint (ordinary tint) on steel surfaces over 10cm width or girth complete all as specified and directed by Engineer-in-Charge. |
| 50 | M&L for preparation of newly plastered or unplastered surfaces of wall and finishing walls with Acrylic smooth exterior paint of required shade : New work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified. |
| 51 | M&L for rendering 15mm thick in cement mortar in 1:4 on fare face of brick work or concrete surfaces even and smooth without using extra cement & with using integral water proofing compound complete all as specified.Note : WPC shall be measured and paid for separately |
| 52 | Taking down cement plaster from ceilings & brick walls including any type of any description, racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed by Engr-in-Charge. |
| 53 | M&L for preparing surfaces plaster or unplastered on old surfaces of wallsand applying two coat of distemper oil emulsion white/tinted using hand roller complete over two coatwall care putty all as specified |
| 54 | M&L for rendering 15 mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified |
| 55 | M&L for Roof Treatment in patches as specified below and as directed :(a) Cleaning, washing of surface and removing all existing bitumen coatings/ APP membrane completely with intense wire brushing or high speed water jet. Surface should be free from any loose paint, dust or grease.(b)All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, damaged portions and hollow areas must be repaired with polymer modified cement mortars.(c)Applying one coat of PrimeSeal/ Epoxy Primer/ShaliUrethane BTD White diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/ sqm (0.20 kg BTD+0.20 Kg water)(d)Laying polyster reinforced fiber net/50 gsm Geotextile mesh, upto 300 mm on walls.(e)Applying three coat of HydroShield PUD microfiber reinforced UV resistant polyurethane (solid content 68% ) / Damp Proof ultra UVStable fibre reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers (Solid content 55%)/ SmartCare PU Magnum elastomeric waterproofing coating based on hydrophobic polyurethane (solid content 85%)/Single Component Elastomeric Liquid Membrane ShaliUrethane BTD White/coloured(Elongation 400% ± 50, Solid Contents > 80% & Specific Gravity @ 30 OC 1.5 ± 0.03) @ total 2.00 Kg per sqm in two coats for maintaining thickness of 1.5mm,with paint brush/ roller upto 300 mm on walls.(f)The complete treatment to be carried out by authorised applicator of waterproofing manufacturer.Make : DrFixit/ Asian/STPNote : (i)The treatment shall be carried out as per the manufacturers instructions, and as directed by Engineer in Charge.(ii)The plan area of floor shall be considered for payment |
| 56 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.all as specified and directed by Engineer-in-Charge. |
| 57 | Taking downMCB, DB any Type including MCBs and making good to the disturbed walls and surface area etc all as specified and directed by Engineer-in-Charge. |
| 58 | Taking down submain wiring any type with earthing cable and making good to disturbed area all as specified and directed by Engineer-in-Charge. |
| 59 | M&L for point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through existing concealed connduit including galvanised steel pressed modular terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc covered with modular top cover sheet including 1.5 sqmm multistranded copper conductor as earth continuity to connect common earth dolly and making good disturbed surfaces of wallscompleteall as specified and directed. for One light point/ Fan point/ Exhaust point/ bell point controlled byone way switch |
| 60 | All as per Srl Item No. 59 here-in-before but one three pin socket out let 5 amps on the same board with other switches |
| 61 | All as per Srl Item No. 59 here-in-before but one 3 pin, 5A switch socket outlet point on independent board |
| 62 | All as per Srl Item No. 59 here-in-before but with 2.5 sqmm cable for 1No 16 amps socket outlet point on independent board including 2.5 sqmm PVC insulated unsheathed cable multistranded with copper conductor as earth continuity conductor complete all as specified and directed |
| 63 | S&F ceiling rose 3 terminal / PVC / polycarbonate isolated body all as specified and directed by Engineer-in-Charge. |
| 64 | S&FModular switch 1 way 6 amps one moduleall as specified and directed |
| 65 | S&F Modular socket 6A 2/3 pin combined 2 moduleall as specified and directed |
| 66 | S&F Modular switch 1 way 16 amps 1 module all as specified and directed |
| 67 | S&F Modular socket 6A / 16A - 2/3 pin combined 2 module all as specified and directed |
| 68 | S&FPVC Lamp holder batten complete all as specified and directed. |
| 69 | S&F of 9 Watt LED lamp all as per specification & directed by Engineer-in-Charge. Make-Havells/Philips/Bajaj. |
| 70 | S&F fan step regulator, 120W - 1 module complete all as specified and directed |
| 71 | S&FLED tube light fitting 20W,230 V, surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire with suitable size as per specification and directed by Engineer-in-Charge |
| 72 | S&F LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as directed by Engineer-in-Charge with following specification:- (a) Lumen efficacy of luminaire should be more than 100 Lumen per watt. (b) Voltage operating range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP20. (g) CRCA pre coated housing. (h) LED Driver of the make as of the luminaire. (l) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Inbuilt Surge protection device for 4 kV. |
| 73 | S&F LED recessed round/surface round , 220 V AC with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED 15W suitable for roof ceiling including connecting up with driverflexible copper conductor cable of suitable size complete all as specified and directed |
| 74 | S&F modern WALL LED LIGHT 4 Watt 2 way Warm White waterproof aluminium Di-Cast 220 V with outdoor lamp complete with including electric connection up with three core flexible copper conductor cases of suitable size complete all as specified and directed |
| 75 | Taking down existing serviceable ceiling fan / Exhaust Fan and deposit to MES store yard complete all as specified and directed |
| 76 | S&F Energy efficient Ceiling fan complete with blades, down rods, suitable for regulator & accessories, 230 V,1200mm sweep,BEE, 5 star rated with brushless direct current motor (BLDC)includingwriting of MES number (Black, Roman, Italic or Indian) n.exc 30cm height complete all as specified and directed |
| 77 | S&F sheet metal enclosure for DB\"s SPN 230 volts 12 waydouble door complete all as specified and directed .. |
| 78 | S&F sheet metal enclosure for DB\"s SPN 230 volts 8 waydouble door complete all as specified and directed. |
| 79 | S&F (concealed flush to wall) factory made loadline DB (made out of CRCA sheetfitted with DIN channel neutral link and 250 Amp rated bus bar) VTPN, 4 Way, suitable for mounting MCCB as incomer and MCB as outgoing conforming to IS-13032, DB shall be semi glossy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-42 protection class, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessity complete all as specified and directed by Engineer-in-Charge.Note :- MCCB/MCB shall be measured and paid separately under appropriate item of BOQ |
| 80 | S&F MCCB 4 pole, 415 V. adjustable type, 100 Amp with breaking capacity 16 KA and including taking down old unserviceable items and as complete all as specified and directed |
| 81 | S&F, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40 AMP, complete all as specified and directed |
| 82 | S&F 10KA \"C\" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 Amp complete all as specified and directed. |
| 83 | S&F 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP,complete all as specified and directed |
| 84 | M&L for wiring for circuit sub main wiring with PVC FRLSinsulatedcopper conductor 2x 4 sqmm and same 1x4 sqmm for continuous earth wire drawn in to and includingconcealed PVC conduit not less than 25 mm dia complete all as specified and directed by Engineer-in-Charge |
| 85 | M&L for wiring for circuit sub main wiring with PVC FRLSinsulatedcopper conductor 2x 6 sqmm and same 1x6 sqmm for continuous earth wire drawn in to and includingconcealed PVC conduit not less than 25 mm dia complete all as specified and directed by Engineer-in-Charge |
| 86 | M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead ofGI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point/DB and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade with funnel & wiremesh, PCC chamber in cement concrete (1:2:4) type B1 including 40mm thick pre-cast RCC (1:2:4) type B0 cover and 40x40x6mm angle iron frame on top of pit cover and excavation & earth work completeall as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. complete all as specified and directed by Engineer-in-Charge. |
| 87 | M&L for laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 core in trenches/floors/wall and under road including connecting with suitable aluminium lugs and including taking up defective unserviceable cable of the any sizes all as specified and directed by Engineer-in-Charge. Note: Earth work, Sand cushioning, GI pipe and cable cover for protection to be measured and paid separately |
| 88 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying cables/poles foundation / stay assembly and getting out in soft/loose soilall as specified and directed by Engineer-in-Charge |
| 89 | Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm all as specified and directed by Engineer-in-Charge. |
| 90 | Removing the excavated soil from the trench n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and directed. |
| 91 | Supply and spread dry fine aggregate sand in trenches for cable cushioning all as specified onboth top and bottom of cable including ramming all as specified and directed by Engineer-in-Charge |
| 92 | M&L for laying factory made un reinforced precast concrete cable cover ISI marked class LV type 2 flat size 300 mmx180 mmx40 mm completelaid in trenches of across the cable protection all as specified and directed |
| 93 | S&F Air termination single pointed aluminium rod 12 mm dia and 300mm long fixing on top of building complete all as specified and directed . |
| 94 | S&F Aluminiumstrip 25x3 mm with saddles and fixing screws etc for roof conductors above ground (top of building and down upto test point complete all as specified and as directed |
| 95 | M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw of brass complete all as specified and directed |
| 96 | Supply and installationHi wall splitair conditioners unit indoor and outdoor complete with remote control unit and within built Heating and Cooling arrangement electric driven single phase of capacity 1.5 TR, BEE 5 star rated complete all as specified and directed |
| 97 | S&F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input voltage variation between 170V to 250 Vwith output voltage stabilizer at 230V with accuracy of ±2.5% and of capacity 5KVA complete all as specified |
| 98 | S&F LED garden light (Bollard type) light fitting luminaries of 9/10 watt in round shape with0.75 mtr height of 3000K with IP 65, PF> 0.90 completed with all accessories including necessary excavation, PCC,connections with twin core copper cable 1.5 Sqmm complete all as specified and directed. |
| 99 | S&F LED Post top lantern 25 Watt made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection round shape , PF> 0.90 completed with all accessories including necessary Suitable size of GI pipe andconnections with suitable sizeof aluminium cable complete all as specified and directed. |
| 100 | S&F three core (3x 2.5sqmm) flexible flat/round cable, copper conductor multistranded, PVC insulated and overall PVC sheathed, 1100 volt, drawn through electric connections with Rigid non-metallic PVC conduit inclusive of all tees, bends, elbows, reducers, bell & including mouth tube ends, junction box laid in ground complete all as specified and directed. |
| 101 | S&F cable junction box of Size 200mm x 160mm x 110mm or any other higher size (Suitable for Pole mounting) complete with fixing accessories and should be insulated and made out of polycarbonate with glass fiber reinforced material having IP-65 protectionin accordance with IEC 60259, fixing with and including SS-304 clamp of size 25x3mm including suitable nut bolts and washers complete all as specified and directed |
| 102 | S&F Energy efficient Wall Mounted fan 400 mmoscillating type with cord complete with accessories, 230 V, includingwriting of MES number (Black, Roman, Italic or Indian) n.exc 30cm height complete all as specified and directed |
| 103 | M&L for PCC 1:2:4type B0 with 12.5 mm graded stone for foundation of Bollard light complete all as specified and directedNote :-A Sum of Rs. 47,534.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 36 (Schedule of credit) of Tender Documents. |