| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 4 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Provision for fitting & fixing of M S grill panel Size ( 2no.x2.00mx1.00m) as per approved drawing & design including cutting, welding, fixing & supply of all material T&P , etc, complete |
| 7 | Provision for fixing and fitting of grill with the position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Providing & laying 12 mm cement plaster of mix cement mortar 1:4 (1 cement : 4 fine sand) including supply of all materials labour T.& P.etc. Required for proper completion of work. |
| 9 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 10 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 11 | Provision for demarcation of site with fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 mtr.(minimum), between the two posts fitted and fixed with G.l. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post( cost of R.C..C. posts, struts, earth work and concrete to be paid for separately):- payment to be made per meter cost of total length of barbed wire used. (a) R.C.C. standard post/ struts/rails/pales of mix 1:1:5:3(1 cement: 1.5 coarse sand: 3 grades stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of engineer-in charge (cost of earth works in excavation, concrete works in foundation to be paid separately) |
| 12 | Supplying and stretching G.l. barbed wire for fencing including materials & labour etc |
| 13 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks 1:4 (1 cement : 4 coarse sand . |
| 14 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): Raised and cut pointing |
| 15 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 16 | Providing and fixing of MS gate with 50x50x5mm size M.S. angle & 16mm square bar including all cutting, fixing and bending etc., required for completion of work |
| 17 | Provision for fitting and fixing signage in steel pipe with MS sheet in size 4\"X3\" including supply of all materials t&p complete. |
| 18 | Usage/Application Water Cooling Brand Aqua soft Type Cold Cooling Capacity120 LPH Warranty1 Year Body Material Stainless Steel Number Of Taps2 Weight150 kg Dispenser Single Dispenser Total Power1.5 kW Coin Operated Rs. 1,2,5,10 Dispensing300 ml,500 ml,1 ltr,2 ltr,5 ltr to 20 ltr Dimension 6.5 x 3.5 x 3.5 feet |