| 1 | Schedule \"A\" |
| 2 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws as specified. |
| 4 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip, straight flashing etc fixed with self tapping screws as specified. |
| 5 | S&F 0.63mm plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip, wall cladding and straight flashings (length and girth as fixed) with grade of zinc coating 275complete all as specified and directed. |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed. |
| 7 | Erection fixing only rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed. (NOTE: Seviceable material obtained from dismantling under Sl item No 5.00 here-in-above shall be reused under the item) |
| 8 | Erection and fixing only steel work in tubular trusses/post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1998 grade St-240 complete all as specified and as directed.(NOTE: Seviceable material obtained from dismantling under Sl item No 5.00 here-in-above shall be reused under the item) |
| 9 | S&F steel work in tubular or square trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to Fe 410-W (Gde-E-250 quality A)complete all as specified and directed. |
| 10 | S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sucnk) forming holes with any attachement Fe 410W (Gde-E-250) complete all as specified and directed. |
| 11 | S&F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary,gusset plates, riveting, etc. n exc.10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 12 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover filletscomplete all as specified and directed.Note :-Dismantling of false ceiling to be carried out carefully without damaging existing fitting and fixtures of flase ceiling items |
| 13 | S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600 x600mm comprising of wall/cleat angle of size 22 x22 x0.35mm and main/cross tee of size 24 x38 x0.35mm with 4mm dia GI wire as suspender and including 4mm thick Plain E-Boardincluding fixing arrangement from steel truss of any type and applying two coats of oil bound distemper over one coat of chalk whiting complete all as specified and directed. |
| 14 | M&L for 2nd class hardwood weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed. |
| 15 | M&L for 4mm thick plywood (no of ply 03), grade BWR,type BB fixed with nails or screws to timber frame work complete all as specified and directed. |
| 16 | M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces complete all as specified and directed. |
| 17 | M&L for preparation of newlypainted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome complete all as specified and directed. |
| 18 | M&L for preparation of old steel surfaces steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coats of synthetic enamel paint over a coat of red oxide, zinc chrome complete all as specified and directed. |
| 19 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but not exc. 4 sqm eachcomplete all as specified and directed. |
| 20 | M&L for MS framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe 410 (Grade E-250) quality-A complete all as specified and as directed. |
| 21 | S&F of Framed work such as grills, gratings, etcwith ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 22 | S&F of 1mm thick Mild steel, plain, black sheet as in wall cladding,steel gates and similar work, cut to size, holes punched and fixed to steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed. |
| 23 | Dismantling of unframed timber scantling40 sq .cm and over in section,in any position complete all as specified and directed. |
| 24 | M&L for well seasoned 2nd class hard wood in scantling, clean sawn timber framed work complete all as specified and directed. |
| 25 | S&Fstainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 26 | M&L for provding cement concrete 1:3:6type C1 (using 20mm graded stone agg) as in hold fast complete all as specified & directed. |
| 27 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work.complete all as specified and directed. |
| 28 | M & L for RCC 1:2:4 Type B1 nominal mix (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundationbeams; plinth beams; basesfor columns, etc.; basement slabs, under-reamed pilesand mass concrete complete all as specified and directed. Note:- Reinforcement and form work required shall be measured and paid seperately. |
| 29 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rough finished surface of concrete complete all as specified and directed. |
| 30 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 31 | Ditto as per items No 29.00 here-in-abovebut 5mm and over upto & incl 10mm dia in stirrups, spaces and binders complete all as specified and directed. |
| 32 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed. |
| 33 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to storeand rubbish off the premises complete all as specified and directed. |
| 34 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing ,including screed bed 20mm thick inCM 1:3 complete all as specified and directed. |
| 35 | M&L for 75mm thick PCC 1:3:6 Type C-2 ( using 40mm graded crushed stone aggregate) as insubbase / hardstanding finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 36 | M&L for 75mm thick cement concrete type C2 1:3:6 using 40 mm graded stone aggregate as in plinth protection with 150 mm wide saucer drain including finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.(Using dimapur sand) |
| 37 | M&L for forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade \"A\" complete all as specified and directed. |
| 38 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed. |
| 39 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed. |
| 40 | Ditto all as per Sl item No. 38.00 here-in-above but except brick complete all as specified and directed.(NOTE: Seviceable brick obtained from demolition under Sl item No 37.00 here-in-below shall be reused under the item) |
| 41 | M&L for brick work with sub class ‘B’ brick, old size (locally available best quality) straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed. |
| 42 | M&L for PCC 1:2:4 type B1 (20 mm graded aggregate) as in coping including necessary formwork etc complete all as specified and directed |
| 43 | M & L for rendering 10mm thick plaster incement mortar (1:6) on fair faces brick work or concrete surfacesfinish the surfaces even and smooth without using extra cement complete all as specified and as directed. (using Dimapur Sand) |
| 44 | M&L for rendering 15mm thick on fair faces of brick work in cement mortar(1:4) using water proofing compound @2% by weight or cement as per manufacture instruction and finishing even and smooth without using extra cement all as specified. (Note: Plastering shall be carried out using Dimapur Sand.)Note: WPC will be measured and paid separately) |
| 45 | Supply only Integral WaterProofing Compound ISI Marked complete all as specified and directed. |
| 46 | M&L for 3mm thick birla wall care putty new or old plastered surface of wall including with prepration of plastered surface complete all as specified and directed. |
| 47 | M&L for preparation of new or previously untreated surfaces of walls and applying two coats of oil based distemper emulsion paint over a coat of primer and putty complete all as specified and as directed |
| 48 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat primer complete all as specified and directed. |
| 49 | S&F in repair harrison rail ,20mm dia mild steel ,chromium plated with fixing brackets,stope,rollers etc. complete all as specified and directed. |
| 50 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, andgetting out in soft and loose soil complete all as specified and directed. |
| 51 | M&L for PCC 1:3:6 Type C2 (Nominal mix) (using 40mm graded stone aggregate), as in foundation, filling and mass concrete complete all as specified and as directed.(Note:- using dimapur sand) |
| 52 | Taking down carefully unserviceable aluminum/ copper point wiring (light/ fan/ socket/ power) complete including fixture & fitting such as switches, sockets, ceiling roses regulators, lamp holder etc. but excluding light fittings & fixture and exhaust fans etc removing and making good disturbed surfaces of wall/ceiling etc completeall as specified and directed. |
| 53 | Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc includingmulti-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc completeall as specified and directed for following :- (Colour code to be followed)One light point controlled by one, one way switch |
| 54 | One ceiling/exhaust fan point controlled by one, one way switch |
| 55 | One socket outlet 5 Amps 5 pin on independent board |
| 56 | One socket outlet 5 Amps 5 pin on same board with other switches |
| 57 | All as per item No. 52.00 here-in-before but with cable size 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm size for one 5 pin 15 Amps socket out let on independent board complete all as specified and directed. |
| 58 | S&Fmodular switch piano, 6 Amps, single pole, one way complete all as specified and directed. |
| 59 | S&F modularsocket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed. |
| 60 | Supply and fixing modular Switch Socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module. |
| 61 | S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed. |
| 62 | S&Fmodular switch piano, 16 Amps, single pole, one way complete all as specified and directed. |
| 63 | Taking downold unserviceable main switch/ DBs/ MCB DBs with MCB including making good the disturbed surface complete as directed. |
| 64 | S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed. |
| 65 | S&F MCB single pole and neutral 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 66 | S&F MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. |
| 67 | S&F PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 250mm x 200mm x 50 mm deep medium quality ISI marked complete all as specified and directed. |
| 68 | Taking down old unserviceable LED tube light fitting / building security light complete all as specified |
| 69 | S&F LED light fitting 1x20 Watt , 220 V , AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 70 | Taking down old unserviceable service cableincluding batten/suspending wires complete all as directed. |
| 71 | S&F of 1100 volts grade heavy duty cabled PVC insulated aluminium conductor served with inner sheating of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than one meter apart including 4 mm suspensionwire one twin core cable 2 core flat of 10 sqmm size complete all as specified and directed. |
| 72 | Supply and Fixing ceiling fans complete with blades, down rods, electronic regulator and accessories , 230 V, 1200 mm sweep.Min air deleivery 210 CFM with service value 6.00 BEE . Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 73 | Supply and fixing LED building secuirty light fittings 25 watt 230 V AC out door type with high pressure dia cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed |
| 74 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth wire 4mm dia by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion all as specified and as directed.(Note: Earth strip beyond 7.5 m length will be measured & paid separately) |
| 75 | Supply and fix aluminium strip 25 x 3.15 mm with saddles and fixing screws, insulators rawal plugs etc forconductor for roof and fixed on wall upto test point complete all as specified and directed. |
| 76 | Supply and fix in repair single pointed air termination Aluminium rod 12mm dia, 300 mm long complete all as specified and directed. |
| 77 | M&L in repair for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth strip of size 32 x 6 mm by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion complete all as specified and as directed.(Note: Earth strip beyond 7.5 m length will be measured & paid separately) |