Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-01-2026 | Revised Tender pages and Sch of credit | Other | 09-02-2026 |
| 2 | 28-01-2026 | Revised BOQ | BOQ | 09-02-2026 |
| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed. |
| 3 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed. |
| 4 | Demolition of reed lathing, single or double including battens and plaster or chiken wire lathing. |
| 5 | Dismantling wall and ceiling boards (AC,fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness including cover fillets, frameworks, etc. complete all as specified and as directed. |
| 6 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 7 | Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed. |
| 8 | Dismantling timber scantlings 40 sq. cm and over in section, in any position in framed work all as specified & as directed |
| 9 | Dismantling boarding any description fixed in any position with nails completeall as specified and directed. |
| 10 | Dismantling rain water pipe and sewage line pipe of any type and any size including fitting complete all as specified and as directed. |
| 11 | Dismantling of timber fillets rails, posts, rafters, purlins etc under 40 Sqcm in section, in any position in unframed work complete all as specified. |
| 12 | Taking down cement or cement/lime plaster,any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed. |
| 13 | Taking down chokhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified. |
| 14 | Taking down chokhats or frame with shutters (without taking off shutters from frame) each exceeding 1.50 Sqm but not exe 4 Sq cm each complete all as specified. |
| 15 | Taking up or down 15mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed. |
| 16 | Taking up or down 20mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed. |
| 17 | M&L brick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick wallin cement mortar 1:4 complete all as specified and as directed. |
| 18 | Material and labour for 10 mm thick rendering in cement mortar (1:6) on other side of lathing surface finished even and smooth all as specified. |
| 19 | M&L for rendering 10mm thick in cement mortar (1:6) on other than fair surfaces of PCC block / brick masonry wall / concretesurfaces, etc. finished fair and even without using extra cement complete all as specified and as directed. |
| 20 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on one side of lathing in CM (1:4) & water proofing compound mixed with second layer @ 3% finished even and smooth all as specified. |
| 21 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair faces of brick wall or condrete surfaces in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even complete all as specified.. ( Note -W.P.C. shall be measured and paid separetly . ) |
| 22 | Supply only integral water proofing compound all as specified. |
| 23 | M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in floors, etc. and jointed in neat cement slurry and pointed in white cement (mixed with colouring pigment to match the colour of tiles), laid over and including 15mm thick screed bed in CM 1:4 (rate shall be included) complete all as specified and as directed. |
| 24 | M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in skirtingincluding10mm thickbacking coat in cement mortar 1:4layingof skirting/dado on walls , etc. and jointed in neat cement slurry and pointed in white cement (mixed with colouring pigment to match the colour of tiles), complete all as specified and as directed. |
| 25 | M&L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcolour of tile over & including 15 mm thick screed bed or bedding layers in cement mortar 1:4completeall as specified and directed. |
| 26 | M&L of Glazed ceramic coloured tilesin vertical surface size 450mm x 300mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including10mm thick screed bed or backing coat in cement mortar 1:4layingof skirting/dado on walls all as specified and directed. |
| 27 | M&L in repairs for 18-20mm thick granite stone slab, of any type, table rubbed and polished, in steps, jambs, pillars, window cills, cooking platforms and the like in laid over and including 15mm thick screed in cement mortar (1:4) (rate shall be included) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of slab and taking off old damaged slab and disposing off complete all as specified and as directed. |
| 28 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 29 | Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 30 | Supply and fix Steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161 - 2014 / IS.4923 - 1997 grade St.-210 complete all as specified and directed. |
| 31 | S&F plates (plain or chequered) channels, square cut or notched (ordinay and counter sunk) forming holes, without any attachmentof Fe 410W (Gde-E -250) Quality \"B\" complete all as specified and directed by Engr-in-Charge. |
| 32 | Supply and fix Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges large hasps and staples; chains; hand made slidingbolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 completeall as specified and directed. |
| 33 | Supply and fix Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 34 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) complete all as specified. |
| 35 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge. completeall as specified and directed. |
| 36 | S&FPowder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge. |
| 37 | Material and labour for Second class hardwood in scantlings timber framed and fixed for wrought in section completeall as specified and directed. |
| 38 | S & F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides , smooth finish with lipping of teak wood on edges all as specified and directed |
| 39 | M & L for 12 mm thick Prelaminated MDF board,Exterior grade, prelaminated on bothside with decorative choice lamination & otherside balancing white lamination, all as directed. |
| 40 | M&Lfor 18mm / 19mm thick Prelaminated MDF board,interior grade,prelaminated on one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work and lipping of teak wood on outer frame complete all as specified & as directed. |
| 41 | S&F for GI wire netting 0.71 mm dia and 12 mm mesh lathing to wood or metal studding joints etc in walls ceiling stanchion,beams etc included all laps cutting and wastes |
| 42 | S&F PVC roller in Aluminium body of suitable size for sliding shutters |
| 43 | S&F side locks of Aluminium body, suitable size for sliding shutters |
| 44 | S&F Mortice lock, vertical type size 100mm, of brass 04 levers vertical type. |
| 45 | Supply and fix 200 mm long aluminum anodised barrel tower bolts of extruded section completeall as specified and directed. |
| 46 | Supply and fix 150 mm long aluminium handles cast type anodised complete all as specified & directed . |
| 47 | S&F 100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed. |
| 48 | S & F 30mm Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed. |
| 49 | Supply & FixedStainless steel wire cloth 0.36mm nominal dia of wire as in repair and average width of aperture 1.40 mmall as directed and specified. |
| 50 | S&F 4.00 mm thick sheet glass ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane completeall as specified and directed. |
| 51 | S&F 4.00 mm thick sheet glass ordinary quality and glazing with oil putting square exc 0.5 sqm in each pane completeall as specified and directed. |
| 52 | S&FAuto close hing complete all as specified . |
| 53 | M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic)in a grid of GI system duly suspended with 4mmdia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid all as specified and directed.Make:Everest Industries Ltd or equivalent as per IS 14862. |
| 54 | Supply and fixed Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing |
| 55 | Supply and fixed 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 56 | M & L for 2nd class hardwood fillets square, rectangular or tringular in section clean sawn screwed with nails exc 13 sqcm and n.exc 25 sqcm complete all as specified. |
| 57 | Supply, lay and fix 15 mm bore galvanized iron water tubing medium grade including all fittings and fixed complete to walls and ceiling or laid in floors. all as specified and directed. |
| 58 | Supply, lay and fix 20 mm bore galvanized iron water tubing medium grade including all fittings and fixed complete to walls and ceiling or laid in floors. all as specified and directed. |
| 59 | Cuttinggrooves or rebates not exceeding 15 cm girth, and trimming with or without reinforced surfaces complete all as specified and directed. |
| 60 | Supply and fix, as in repair,vitreous china wash basin, white flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified. |
| 61 | Supply & Fixed inrepairsVitreous china wash down water closet pan ( pedestal pattern ) , whitewith P or S trap incl. seat cover but excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed. |
| 62 | S & F in repairsPVC valveless,syphonic action type,low level PVC flushing cistren 10 ltr capwhite with flush pipe &all fitting and flush pipe complete all as specified. |
| 63 | S &F Soap Dish chromium Plated complete all as specified& as directed. |
| 64 | S&F in repairs toilet paper holder recessed type vitreous China of approved design complete all as specified and as directed |
| 65 | Supply and fix in repairs15 mm bore bib taps,chromium plated,cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified. |
| 66 | Supply and fix in repairs15 mm bore stop/angle valve,cast copper alloy,,screwed down high pressure, with crutch or butterfly handles for 15 mm bore pipe or for unions all as specified. |
| 67 | Supply and fix in repairs15 mm bore pillar tap, cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe . |
| 68 | Supply and fix in repairHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 69 | S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing, 60cm long fixed in position with CP screws complete all as specified and as directed |
| 70 | S&F in repair 12mm thick corner glass shelf, 250mm radius, with flanges of brass chromium palted D clamps, including brackets and railing fixed with CP scrws complete all as specified and as directed |
| 71 | Supply and fix 125mm dia CP brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of CP brass approved make like Parryware of CAT No-T9809A1 or Equivalent as in repair complete all as specified. |
| 72 | Supply and fix, asin repairs, 32 mm dia and 800mm long PVC flexible corrugated waste pipe for wash basin/sink complete all as specified and as directed.(Prayag CAT No. 327) |
| 73 | S&F in repairs PVC connections 15mm dia size with PTMT nuts of length 450mm. |
| 74 | S&F in repairs kitchen sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes,including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets andconnecting union to pipe, overall size 915mm X 460mm bowl size 410 mm X 330mm X 160mm etc complete all as specified and as directed. |
| 75 | S&F in repairs Stainless steel kitchen plate rack of approved make like Prayag of CAT No- P-340 or Equivalent, Overall size( in inches) not less than 31cmx 24cm x 10cm complete all as specified. |
| 76 | S&F 600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fxed to wooden plugs with chromium plated brass screw and cup washer etc. |
| 77 | S&Fbrass chromium plated tubular towel rail 20 mm dia 60 cm long, with fancy type brass chromium plated bracket on both sides and fixed with steel screws and wooden/ rawl plugs as in repairs complete allas specified . |
| 78 | S&F 25 mm dia and 1mm thick MS chromium platedcurtain rods with fixing side brackets end knobsand fixed with PVC rawl plugs & steel screwsetc all as specified and directed . |
| 79 | S&F for 110 mm dia PVC (SWR) pipes single socked in any length with rubberjoints, laid in trenches or in floor all as specified & directed. |
| 80 | S&F for 75 mm dia PVC (SWR) pipes single socked in any length with rubberjoints, fixed to walls all as specified & directed. |
| 81 | M&L for 75mm PVC(SWR) bends all as specified and directed . |
| 82 | M&L for 110mm PVC(SWR) bends all as specified and directed . |
| 83 | Supply & Fixed PVC (SWR) vent cowl (75 mm) all as specified and directed . |
| 84 | S&F PVC (SWR) junction single , ( single T) 110 mm bore equal or unequal all as specified and directed . |
| 85 | M&L for 75mm PVC(SWR) floor trap, plain with grating incl jointing with solvent all as specified and directed . |
| 86 | Material & Labour for 1mm thick wall care putty over plastered surfaces and finishing even and smooth complete all as specified and as directed |
| 87 | Material and labour for preparation of new or previously untreated wall surfaces and applying three coats of white wash complete all as specified and directed. |
| 88 | Material and labour for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etcand applying two coats of white wash complete all asspecified and directed. |
| 89 | M&L for prepration of new or priviously untreated surface and applying two coat of oil bound distemper over a coat of primer on wall complete all as specified and directed. |
| 90 | Material and labour for preparation of old decorated plastered surface or unplastered wall surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etcand applying two coats of Oil bound distemper using roller over a coat of primercomplete all as specified. |
| 91 | Material & Labour for for preparation of old decorated plastered surface or unplastered wall surfaces including brooming down or steel wire brushing , scrapping down smoke, soot , moulds , moss and efflorescent salts and trading oil and greasy spots etcand applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as specified & directed. |
| 92 | Material & Labour for preparation of new plastered surface applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as specified & directed. |
| 93 | M&L preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 94 | M&L preparation of new wood or wood base surface of any description over 10cm width or girth applying two coats of synthetic enameled paint over one coat of pink primer complete all as specified. |
| 95 | Material and labour for preparation of old painted wooden surfaces of any description, not otherwise described exceeding 10 cm width or girth and applying two coat of synthetic enamel paint complete all asspecified and directed. |
| 96 | E & M Division items |
| 97 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc includingremoving from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 98 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 99 | Taking out old U/s XLPE cable of any size/type taking out of olf bricks/cable cover complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 100 | Taking out old U/s GI PIPE of any size/type including all GI fittings etc complete all as specified and directed. (Excavation and earth work will be measured and paid separately under respective items) |
| 101 | Dismantling of U/s GI pipe of size 40 mm bore complete all as specified and directed. |
| 102 | Dismantling old unserviceable main switches, sheet metal enclosures DB including MCBs etc and removing from site for taking credit incl making good to disturbed surface of wall as per existing specification complete all as specified and as directed. |
| 103 | M&L for point wiring with FRLS stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne light point controlled by one switch. |
| 104 | M&L for point wiring with FRLS stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 105 | M&L for point wiring with FRLS stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 106 | M&L for point wiring with FRLS stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 107 | M&L for point wiring with FRLS stranded copper conductor2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 108 | M&L for point wiring with FRLS stranded copper conductor4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forone power point AC/Geyser equipments etc controlled by one SP/SPN MCB on independent board . Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 109 | S&F Modular switch 1 way 6 Amp, 1 module complete all as specified and directed. |
| 110 | S&F Modular socket 6A - 2/3 pin combined 2 module complete all as specified and directed. |
| 111 | S&F Modular switch socket combination 16 Amp, 6 pin, 3 module complete all as specified and directed. |
| 112 | S&F Modular Fan Regulator, 120W 2 module complete all as specified and directed. |
| 113 | S&F White cover plate with frame of 3 module completeall as specified and directed. |
| 114 | S&F White cover plate with frame of 4 module completeall as specified and directed. |
| 115 | S&F White cover plate with frame of 8 module completeall as specified and directed. |
| 116 | M&L for point wiring with FRLS stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne light point controlled by one switch. |
| 117 | M&L for point wiring with FRLS stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne fan point/exhaust fan point controlled by one, one way switch 5 Amp |
| 118 | M&L for point wiring with FRLS stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne bell point controlled by one bell switch 5 Amps. |
| 119 | M&L for point wiring with FRLS stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forOne 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 120 | M&L for point wiring with FRLS stranded copper conductor1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 121 | M&L for point wiring with FRLS stranded copper conductor2.5 sqmm (nominal area), two single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulatorsincluding FRLS PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent, |
| 122 | M&L for point wiring with FRLS stranded copper conductor4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 markedin and including heavy duty, PVC casing caping including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed forone power point AC/Geyser equipments etc controlled by one SP/SPN MCB on independent board . Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 123 | S&Fswitch piano flush type button single pole one way 5 Amps all as specified and directed. |
| 124 | S&F socket outlet 2 in 1, 3 pin 5 Amp flush type all as specified and directed. |
| 125 | S&Fswitch piano flush type button single pole one way 15 Amps all as specified and directed. |
| 126 | S&F Socket outlet 2 in 1, 3 pin, 5 and 15amp flush type all as specified and directed. |
| 127 | S&F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified. |
| 128 | S&F bell push flush type 5 Amps all as specified and directed. |
| 129 | S&F bell electric ding dong type suitable for operation on 230 volt 50 Hz AC supply complete all as specified and as directed |
| 130 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 131 | M&L for submain wiring with two single core 1.5 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid PVC Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 1.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLS connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 132 | M&L for submain wiring with two single core 4.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid PVC Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 2.5 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLS connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 133 | M&L for submain wiring with two single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit conceled with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLS connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 134 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 135 | Supply & Fix LED betten plastic type fitting of capacity 20W, operating on 230V, 50Hz, AC Supply having luminous efficacy of not less than 125 lumens/watts, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified. |
| 136 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.. |
| 137 | S&F LED decorative light fitting made up of Polycarbonate, suitable for 9W LED lamp B22 base, classic wall light suitable for living / bed room, antique surface, sleek, of aproved design with 9W LED lamp and connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. Cat No: LHDL06160099 of Havells or equivalent make ofCrompton /M/S Jaquar & Company Pvt Ltd. |
| 138 | S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook includingincluding taking down of old UNSV one and depositing to MES storeyard for keeping in safe custody complete all as specified and directed. |
| 139 | S&F plastic body exhaust fan300 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces including taking down of old UNSV one and depositing to MES store yard complete all as specified and as directed. |
| 140 | S&F bldg security light, LEDluminaire 30 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. Make - Crompton/ Havells/M/S Jaquar & Company Pvt Ltd. |
| 141 | S&F in replacement LED Bollard with robust & efficient soft 360 degree light distribution through its PMMA window, IP 65protection and high power LED consuming 8/9 watt(incuding driver) incl all fixing arrangementcomplete all as specified and directed. Cat Part No: CONEBLS8WLED830PSYMTOPC (MOUNT LED BOLLARD) of Havells or equivalent make of Crompton/M/s Jaquar & Company Pvt Ltd |
| 142 | S&F in replacement decorative LED post top lantern with IP 65 protection with high power LED consuming 20 watt for360 degree indirect natural white light withIP 65 protection , polycarbonate diffuser and efficient light distribution incl all fixing arrangement (ncl taking down the old unserviceable post top lantern complete all as specified and directed. Make - Havells or equivalent make of Crompton/M/s Jaquar & Company Pvt Ltd / Bajaj |
| 143 | S&F shock proof and rust proof pole mounted junction box of size 140 x 140 x 90 mm for street lighting system complete with all accessories and including MCB SP 6 Amp & 100 Amp rated heavy duty connector, 2 terminals, pole clamp with nut bolts, cable gland with cable entry, suitable lugs, etc with necessary mounting arrangement in the junction box with pole fixed in repairs complete all as specified and directed. Code No: GS-JB-1414 of Sintex Industries Ltd or equivalent make ofSupreme Industries/ Naithani Plastic Moulding Works. |
| 144 | S&F Angle bracket 40mm dia for fixing building security light of 40mm dia of 1 mtr long bent to shape 45 degree for fixing of security light including MS clamps of suitable size including nuts, bolts complete all as specified and directed |
| 145 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc complete all as specified and as directed. |
| 146 | S&F metal plug socket with MCB SP 20 Amp, 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed. |
| 147 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 148 | S&F sheet metal enclosure powder coated three phase and neutral DB for fixing of MCBs, 4 way double door with bus bar includinggrouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 149 | S&F MCB TPN of capacity 63 Amps 4 pole,240 V, 10 KA \"B\" curve complete all as specified and directed. |
| 150 | S&F MCB SPN of capacity 40-63 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 151 | S&F MCB SP of capacity 5-32 Amps,240 V, 10 KA \"C\" curve complete all as specified and directed. |
| 152 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors 1100 volts grade, cross sectional area 25 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 153 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors 1100 volts grade, cross sectional area 16 sqmm 4.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 154 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors 1100 volts grade, cross sectional area 6 sqmm 2.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 155 | S&F gun metal gate valve 25mm dia, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed. |
| 156 | M&L for steel water tubing 25mm dia, medium grade galvanised with new fitting laid in trenches or on wall complete all as specified and directed. |
| 157 | Material & labour GI tube light grade 40 mm bore for protection ofcable complete all as specified and directed. |
| 158 | M&L for cutting of existing GI pipe line 25mm dia for inserting Tee and reducer etc for taking 25mm dia branch pipe including fittings complete |
| 159 | M&L PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate with 100mm thick for flooring complete all as specified and directed. |
| 160 | M&L in replacement for earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 161 | M & L for new Earthing complete with galvanised steel earth plate electrode600mmx600mmx6 mm thick buried directly in ground (earth pit not less than 2.25 RM deep below normal ground level) with top edge of the plate not less than 1.5 RM below normal ground level, connected to GI earth strip of 25x4 mm as earth lead by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electric plate No 3, of SSRPart - I, 2009&all as specified, testing on completion including provision of earth lead protected by 40 mm dia GI pipe medium grade & watering pipe 20 mm medium grade including all excavation and earth work in any type of soil, PCC earth pit with RCC cover, charcoal& salt, PGI funnel with wire mesh etc complete incl GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth work in soft/hard/ dense soil and disposal of soil to a distance n exc 50 m complete all as specified and directed. |
| 162 | Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed. |
| 163 | Returning, filling in trenches incl. spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. |
| 164 | Removing of surplus soil to a distance not exceeding 50 meter and deposited where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed. |
| 165 | M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. |
| 166 | M&L for bricks sub-class \"B\" laid in trenches for cable protection complete all as specified and directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail