| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 2 | Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 3 | Taking down shutter of any description n exc 1 sqm each complete all as specified and directed. |
| 4 | Taking down shutter of exc 1 and n.exc 2 Sqm each complete all as specified and directed. |
| 5 | Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each and refixing in same opening including easing and adjusting of shutter as required including renewal of unserviceable screws all as directed. |
| 6 | M&L 2nd class hardwood, Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed. |
| 7 | M&L for 30mm thick, 2nd class hardwood plain framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkhats complete all as specified and directed |
| 8 | S&F 30mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, commerical type on both sides complete all as specified and directed. |
| 9 | S&F 35 mm thick2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, without sash bars, edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc. The size of rails & style as specified in SSR Part-I (2009) section 8 and as per IS-1003(Part-I) kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and directed.(Note :- S & F Glass/gauge shall be measured and paid for separately) |
| 10 | S&F in repairs 18/19 mm thick block board grade 2nd quality interior grade decorative veneer on one face fixed with screw to timber frame complete all as specified and directed |
| 11 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes far top and bottom rails, MS frame shall be covered with heatmoulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail;Paneling of plain colour PVC sheets to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cementcomplete all as specified and as directed. |
| 12 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm Prelam colour PVC sheet & edges painted to match with prelam sheet reinforced with M.S. Square tube, & fixing in opening complete asper specification & drawing as specified in SSR Part I, Section 8 and as directed. |
| 13 | S&F powder coated anodised aluminium (minimum thickness of powder coating 50 micron) frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directedNote:- Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed. |
| 14 | Supply and fixing powder coated Anodised aluminium (minimum thickness of powder coating 50 micron) window and ventilator/partitions, any type including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws alongwith standaraed locking arrangement, handles, tower bolts etc as required complete all as specified and as directed.Note:- (i) Labour charges for fixing of glass/wire guage/aluminum grills is inclusive in the unit rate quoted. Glass/Wire Guage/aluminum grills shall be measured and paidseperately aa supply only rates. (ii) Design/pattern, profile sizes and other dimensions shall be of standard sizes and as directed |
| 15 | Supply only 4 mm thick sheet tinted glass, ordinary quality fixed with aluminium frame work square n exc 0.5 sqm in each pane complete all as specified and directed. |
| 16 | Supply only 4 mm thick sheet tinted glass, ordinary quality fixed with aluminium frame worksquareexc 0.5 sqm in each pane complete all as specified and directed. |
| 17 | S&F prelaminated particl board 12 mm thick interior grade prelaminated one side with decorative choice laminationand other side balancing white lamination fixed to aluminium frame work all complete all as specified and directed. |
| 18 | S&F stainlesssteel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 19 | S&F in repair stainlesssteel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 20 | Hacking out old broken glass any thickness size quality or description from wooden frame concrete or brick surroundings glazed with putty with beads complete all as specified and directed. |
| 21 | M&L for 3 mm thick sheet glass ordinary qualityand glazing with oil putty/wooden beads in squares not exc. 0.5 Sqm in each pane complete all specified and as directed. |
| 22 | S&F 200 mmlong Aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed. |
| 23 | S&F 125 mmlong Aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and as directed. |
| 24 | S&F 300 mm aluminium alloy sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy fixed complete all as specified and as directed. |
| 25 | S&F 150 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 26 | S&F 100 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed. |
| 27 | S&F 100 mm size Butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and as directed. |
| 28 | S&F 75 mm size Butt hinges, medium weight, cold rolled mild steel and fixed complete all as specified and as directed. |
| 29 | S&F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 &ISI marked complete all as specified and directed. |
| 30 | S&Fmild steel hold fasts; for securing chowkhats and similar small articles conforming to Fe-290 Gde-E-165 incuding treating hold fast with tar or coal tar black paint, sandingcomplete all as specified and as directed. |
| 31 | M&Lproviding plain cementconcrete type C-1, (1:3:6), (using 20 mm graded stone aggregate), as in copings,fixing of hold fast, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 32 | M&L for preparing new wooden surfaces of any description, not otherwise describe over 10cm width or girth and applyingtwo coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 33 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed. |
| 34 | S&Fpowder coated anodised aluminium interlocking snap grid frame work size (600 mm x 600 mm) consists of main tee runners of size 38mm x 25mm x1.5mm and cross wall angle of size 25 mm x 25 mm x 1 mm spaced between the main Tee at 600 mm centre to centre to form a grid of 600 mm x 600 mm etc completeincluding necessary notching preparing holes and supporting hanger comprising of J hooks soffit cleat holding clip, level clip etc as per manufacturer instructions complete all as specified and directed. |
| 35 | M&L for 4 mm thick, Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Alumi nium framework with screwscomplete all as specified and as directed. |
| 36 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 37 | S&F Mild steel framed work such as grills, gratings etc.with ends of bars shouldered and/or riveted,or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and as directed. |
| 38 | S&F Mild steel framed work in tubular trusses and tubular posts using ERW or induction butt welded tubes conforming to I.S 1161-1979 Grade St-240 including necessary welding, bolting, special shaped washer, clamps, cleats etc. with and including one shop coat of zinc chromate primer paint complete all as specified & as directed. |
| 39 | M&L for preparing new Steelsurfaces of any description, not otherwise describe over 10cm width or girth and applyingtwo coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 40 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as directed. |
| 41 | S&F Prepainted galvalume aluminium zink coating GI based corrugated/semi corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 42 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwscomplete all as specified and as directed. |
| 43 | M&Lforbituminous primer @ 0.30 KG/Sqm over the cementplaster inclpreparation of surfacesas permanufacturers instruction complete all as specified and as directed. |
| 44 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application) land on primed surface by forced application complete all as specified complete all as specified and as directed. |
| 45 | Demolition of brick work/ block masonry or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material complete all as specified directed. |
| 46 | M&L for Brick work with sub class \"B\" bricks straight or curved on plan exc 6.00 mtr mean radius built in CM (1:6) using old size bricks complete as specified and directed. |
| 47 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 48 | Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 49 | M&L for 15mm thick rendering with cement mortar (1:4)on fair faces of brick work in two layers (10mm& 5mm) seperately mixed with water proofing compound in top layer as per manufacturer\"s instructions and finishing the surface even and fair without using extra cement complete all as specified and as directed.Note:- WPC shall be measured and paid seperately under appropiate item. |
| 50 | Supply only liquid water proofing compound complete allas specified and as directed. |
| 51 | M&L for rendering 10 mm thick onfaces of brick work or concrete surface in CM (1:6), finished even and smooth without using extra cementcomplete all as specified and directed. |
| 52 | M&L for preparation of new plastered surfaces of walls and applying two coats of acrylic distemperover a coat of primer complete all as specified and as directed. |
| 53 | M&L for preparing newly plastered walls surfaces and applying two coats of cement base paint over and including a coat of cement base primer complete all as specified and directed. |
| 54 | M&L for preparing old plastered surfaces of wall and applying one coats of cement base paint complete all as specified and directed. |
| 55 | M&L for preparing old plastered surfaces of ceiling and applying one coats of cement base paint complete all as specified and directed. |
| 56 | M&L for preparing old plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed. |
| 57 | M&L for preparation of oldplastered surface of wall and applying distemperingtwo coats with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as permanufacturer\"s specification complete all as specified and directed |
| 58 | M&L for preparation of oldplastered surface of wall and applying distemperingtwo coats with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as permanufacturer\"s specification complete all as specified and directed |
| 59 | NOTESfor BOQ serial item No.57.00 & 58.00- (a) The work pertaining to periodical services & Water Proofing shall be executed by authorized applicator through manufacturer of which the materials i.e. Paint, Distemper,Putty etc. is proposed to be used by the contractor and approved by GE.(b) The cost of scaffolding upto 10m height of building shall be included in the quoted rate.(c)The contractor shall upload MOU letter with any one of manufacturer and also with their authorised applicator mentioned in the tender alongwith their bid in cover-I failing which his bid will be rejected. Authorised applicator shall have valid authorisation letter from the manufacturer (Minimum regional HQs) and shall have been issued not less than 30 days from the date of commencement of the work.The authorisation letter needs to be valid for the complete period of execution of the painting work.(d)After preparation of the surface, Engr-in-Charge shall approve the same before applying primer and finishing coats.(e) Building wise stage passing register shall be maintained and shall be signed by Engr-in-Charge and contractor.(f) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU been entered into.(g) Contractor shall submit approved company generated 05 years warranty card at the time of submission of RAR & Final Bill. 15% amount of this item will be retained in FB for a period of 05 years from the certified date of completion. (h) Masking of windows / doors during spray painting using polythene film is inluded in the quoted rates.(j) Cleaning and clearing of site of painting, mats etc after completion of work is included in the quoted rate. |
| 60 | M&L complete removal of existing treatment on wall and apply two coat of oil bound distemper over one coat of primer over 3 mm thick wall care putty complete all as specified and directed |
| 61 | M&L for preparation of old or previously treated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 62 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar complete all as specified. |
| 63 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) including disposal of the debries complete all as specified and as directed. |
| 64 | M&L for 25 mm thick cement concrete type B-0, (1:2:4) using 12.5mm graded aggregate as in PCC under layerall as per specified and directed |
| 65 | M&L for 75mm PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as plinth protection/ paving finish even and smooth without using extra cement,including joint filling with bituminus filler of grade 82/25 grade complete all as specified and directed. |
| 66 | Dismantling floorhearth or wall tiling including cement mortar bedding but not backing and removing debrires from the site complete all as specified and as directed. |
| 67 | M&L for Virified Ceramic light shade tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including cement screed 15 mm thick 1:6 complete all as specified and as directed. |
| 68 | M&L for Virified Ceramic light shade tiles 10 mm thick (square/ rectangular) polished in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing with CM (1:4) complete all as specified and as directed. |
| 69 | M&L for coloured glazed ceramic tiles 300 x 450 x 7 mm/ 450 x 350 x 7mm thick in vertical surfaces and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing with CM (1:4) complete all as specified and as directed. |
| 70 | M&L for Non skid coloured tiles7 to 8mm thick (square/ rectangular) area of each tiles exc 0.11 sqm but not exc 0.18 sqm in flooretc set and jointed in neat cement slury over and including cement screed 15 mm thick 1:6 complete all as specified and as directed. |
| 71 | M&L for 18-20mm thick black Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in over and including20mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including necessary dismantling of existing unserviceable one complete all as specified and as directed. |
| 72 | S&F machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid over 50mm thick sand bed layer complete all as specified and as directed. |
| 73 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc. including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fitting and accessories) complete all as specified and as directed. |
| 74 | S&F PVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 75 | S&F PVC (SWR) 75mm bore pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. |
| 76 | Takingup or down 15 mm bore GIpipe and connection complete all as specified and as directed. |
| 77 | M&L for 15 mm bore tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed |
| 78 | Takingup or down 20 mm bore GIpipe and connection complete all as specified and as directed. |
| 79 | M&L for 20 mm bore tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed |
| 80 | Takingup or down 25 mm bore GIpipe and connection complete all as specified and as directed. |
| 81 | M&L for 25 mm bore tubes, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed |
| 82 | Supply and fixing in repair 24\"x31\"x10\" Stainless steel kitchen plate rack fixed with chromium plated brass screws and cup washers complete all asspecified and as sdirected. Make- JAINKO- CAT No-KRJ-2 or equivalent as approved by GE from list of approved make. |
| 83 | Supply and fixing 500 liters rotational moulded polyethylene water storage tank, multi layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-Iincluding dismantling of old existing water tank and removing from site complete all as directed. |
| 84 | Supply and fixing 1000 liters rotational moulded polyethylene water storage tank, triple layered (cylindrical vertical with closed top cover) as per IS-12701-1996, hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-Iincluding dismantling of old existing water tank and removing from site complete all as specified and as directed. |
| 85 | S&F in repair ball valve high pressure of PTMT suitable for 20mm bore pipe (minimum weight -210Gm) with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed |
| 86 | S&F in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests with P or S trap and front or back inlet including 150mm cement concrete (1:5:10) type E-2 using 40mm graded crushed stone aggregate) and matching the disturbed surface with cement mortar or like etc complete all as specified and as directed. |
| 87 | S&F in repair, 10 ltr capacity PVC valve less, symphonic action type,flushing cistern, low level, withinlet ball valve, float and brackets includingflush pipe and PVC connection pipe 15mm bore with PTMT nuts of length 450mm, complete all as per directed. |
| 88 | S&F in repairs coloured plastic water closet seatcover, closed pattern with flat bottom including mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 89 | S&F in repair Hand shower (health faucet) (ABS Body) mild steel chromium plated for 15mm dia pipe1.25 meter long flexible tube & ABS wall hook including making connection and fixed in position complete all as specified and as directed |
| 90 | S&F Toilet paper holder with flat recessed type stainless steel complete all as specified and directed.\" |
| 91 | S&F in repair 15mm bib tap cast copper alloy chromium platedwith crutch or butterfly handle screwed down for iron pipe or for bass ferrule complete all as specified and as directed |
| 92 | S&F in repair vitreous China wash down water closet pan (pedestal pattern), white white with P or S trap including connection to drain (or outgoing pipe and to flushing pipe anti shyfonic pipe and fixing including etc (excluding flushing cistern, PVC connection pipe, plastic seat cover) complete all as specified and as directed. |
| 93 | S&F in repairs vitreous china wash basin, white, flat back, size550x400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed. |
| 94 | S&F in repair 15 mm bore pillar taps,fancy type cast copper alloychromium plated with capstan head screwed down high pressure, with or without lettered HOT or COLD with long screwed shanks and fly nuts, screwed fly nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 95 | S&F in repair 600 x 450mm bevelled edge mirror of selcted quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified complete all as specified and as directed |
| 96 | S&F in repair brass chromium plated tubular towel rail 20mm dia,D Type 600 mm long with and including chromium plated brass screws complete all as directed. |
| 97 | S&F in repairs 15mm bore stop valve cast copper alloy chromium plated, fancy type screwed down high pressure long shank and cup concealed type with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. |
| 98 | S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed . |
| 99 | S&F 75 mm bore PVC (SWR)bends any radiuscomplete all as specified and directed. |
| 100 | S&F 110mm bore PVC (SWR)junction, single (Single T)equal or unequal complete all as specified and directed. |
| 101 | S&F 110 mm bore PVC (SWR)bends any radiuscomplete all as specified and directed. |
| 102 | S&F in repairs 15mm bore PVC connections, with PTMT nuts of length 450mm complete all as specified and directed. |
| 103 | M&L for cleaning and degermination of water storage tank 500 Ltr capacity of any description and in any position and making locking arrengment to tank cover comprising following seven stages of operation complete all as under (i) Drain out the water by using exit valve or our own high capacity dewatering system (ii) Cleaning all the algae formation inside the tank by using TERBAC G10/SODIUM HYPOCHLORIDE a laboratory tested branded chemical of the company and scrubbing the walls of the tanks. (iii) Fresh water cleaning by high speed jet pumpwith pressure 5 PSI. (iv) First bacteria screening is Sterilization by using TERBAC G5/ SODIUM HYPOCHLORIDE & HALOGEN COMPOUND a Laboratory certified branded halogen compound, test certificate of TERBAC G5/ SODIUM HYPOCHLORIDE & HALOGEN COMPOUND from government laboratory mentioningsuitability for sterilization should be submitted to the office before using for sterilization. (v) Cleaning the floor of the water tank byheavy duty industrial vacuum cleaner. (vi) Second bacteria screening and sterilizing method by using ultra violet ray Ejector covering 360 degree with in the tank and kills all suspended bacteria. (vii) Cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agent TERBAC- G65/ (CLASS-1) HYDROGEN PEROXIDE. Test certificate of Terbac-G65 From Government Laboratory mentioning suitability for sterilization should be submitted to the office before using for Sterilization. NOTE: Make of the material shall be approved by HQ E-in-C\"s New Delhi branch / HQ CEEC Kolkata or any other Command/ADG |
| 104 | All as per item No.102.00 here-in-above but 1000 Ltr capacity |
| 105 | Removal of blockage/chock upobstructing the flow in sewage line by rodding with rods/wooden kempti/ chock remover and making the continuous flow between two manholes for 100mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured. |
| 106 | Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/ chock remover and making the continuous flow between two manholes for 150mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured. |
| 107 | Removal of blockage/chock up obstructing the flow in sewage line by rodding with rods/wooden kempti/ chock remover and making the continuous flow between two manholes for 200mm bore of pipe complete all as specified and directed. Note : The clear distance between two manholes shall be measured. |
| 108 | M&L for cleaning of sewer line of any depth, of any location manhole of any depth, section size between the sewer lines sewer line to septic tank/soakwell/sump well by means of sewage sucking machine or by way of any other suitable means including disludging foreign material, sand ashes fibre silt grease. night soil, etc and removing the taken out sludge/material out side MD land by any means/source keeping the sewage line functional for the 100 mm bore pipe lines complete all as specified and as directed |
| 109 | M&L for cleaning of sewer line of any depth, of any location manhole of any depth, section size between the sewer lines sewer line to septic tank/soakwell/sump well by means of sewage sucking machine or by way of any other suitable means including disludging foreign material, sand ashes fibre silt grease. night soil, etc and removing the taken out sludge/material out side MD land by any means/source keeping the sewage line functional for the 150 mm bore pipe lines complete all as specified and as directed |
| 110 | M&L for cleaning of sewer line of any depth, of any location manhole of any depth, section size between the sewer lines sewer line to septic tank/soakwell/sump well by means of sewage sucking machine or by way of any other suitable means including disludging foreign material, sand ashes fibre silt grease. night soil, etc and removing the taken out sludge/material out side MD land by any means/source keeping the sewage line functional for the 200 mm bore pipe lines complete all as specified and as directed |
| 111 | Removing blockage from WC/floor trap/nahani trap/gully trap upto 1st manholecomplete all as specified and directed. |
| 112 | Taking down / out the covers from septic tank / soakage well and dewatering the contaminated / waste materials from septic tank/soak well / sump well of any liquid depth / capacity by means of using mechanical pumps disel driven with fuel or by operator sewage sucking machine or by way of any other suitable means including desludging foreign materials, sand shes fibre silt greease, night soil etc and removing the taken out sludge mixed materials/liquid out side MoD land of any means / sources and replacing the covers back to its normal its normal position complete all as specified and as directed.Note:- Volume of sludge shall be measured for the purpose of payment. |
| 113 | Cleaning /desludging of existing septic tank of any capacity / sump well of any dia and depth including taking out sludge in any form and other foreign materials etc viz sediment sand, ash grease, fibre, silt. Roots or vegetation means of sewage sucking machine or by or by way of any other suitable means and removing the sludge outside MoD land by any means including writing with date of cleaning with white paint in block size of 150x200mm all as specified and as direected. |
| 114 | M&L for De-silting/De-sludging of sump at sewage pumping station depth n.exc 15mtr with required rope, bucket, ladder and scaffolding etc and getting out removing & disposing off complete all as specified and directed. |
| 115 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc not exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 116 | Returning filling in, including spreading. Levelling, watering and well ramming in layers not exc. 25 cm in soft/loose soil complete all as specified and as directed. |
| 117 | Removing excavated material (soil) to a distance not exc. 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 118 | M&L for PCC (1:3:6) type C2 (using 40mm graded stone aggregated) as in concrete bed to drain pipe 150mm dia pipes including packing under and haunching against the sides of the pipes after laying & testingcomplete all as specified and as directed. |
| 119 | M&L for 150mm internal diameter salt glazed stone ware drain pipes grade \"A\" laid in trenches & jointed as specified complete all as specified and as directed. |
| 120 | M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete after demolition of existing concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 121 | M&L for plain cement concrete (1:2:4) type B0 (using 12.5 mm graded aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed. |
| 122 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as necessary to facilitate demolition complete all as directed. |
| 123 | M&L forproviding precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in cover slab (for manholes etc) set in cement mortar (1:4) complete all as specified and directed. |
| 124 | M&L for TMT steel bars, 8mm dia, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.90mm dia complete as in reinforcement to concreteall as specified and as directed. |
| 125 | Supply & Fixing 110mm bore PVC (SWR) Pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 126 | Supply & Fixing 75mm bore PVC (SWR) Pipes single socketed, in any length with rubber ring joints,laid in trenches or in floors complete all as specified and directed. |
| 127 | Supply & Fixing 75mm bore PVC (SWR)junction, double (double T)equal or unequal complete all as specified and directed. |
| 128 | Supply & Fixing PVC (SWR) branch piece, single (single -Y) equal or unequal 110mm dia complete all as specified &directed. |
| 129 | Supply & Fixing PVC (SWR) branch piece, single (single -Y) equal or unequal 75mm dia complete all as specified &directed. |
| 130 | Supply & Fixing Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof suitable for 100 mm dia including drilling holes & fixed to wall with nails etc complete all as specified and as directed. |
| 131 | Supply & Fixing Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof suitable for 75 mm dia including drilling holes & fixed to wall with nails etc complete all as specified and as directed. |
| 132 | Supply & Fixing in repairs PVC(SWR)Nahani trap 75 mm dia with grating including jointingwith solvent cement complete all as specified and as directed. |
| 133 | Supply & Fixing in repairs PVC (SWR) gully trap 125x110 mm including jointingwith solvent cement complete all as specified and as directed. |
| 134 | Supply & Fixing PVC (SWR) vent cowl of 110mm dia complete all as specified and as directed. |
| 135 | Supply & Fixingin repair PVC (SWR) \"P’ trap 110mm bore complete all as specified and as directed. |
| 136 | Supply & Fixing in repair Grating doom 150mm dia of PTMT (Minimum weight 100gms) complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail