| 1 | B & R Division Items |
| 2 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed. |
| 3 | Demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but exluding ashlars facings, dressed stone work and pre-cast concrete articles all as directed. |
| 4 | Demolition of reed, lathing single or double including battens and plaster or chiken wire lathing complete all as specified and directed . |
| 5 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 7 | Dismantling of asbestos cement (corrugated, semi-corrugated, etc) sheets in roof covering complete all as specified and dircted. |
| 8 | Dismantling of wall and ceiling boards (fibre, pulp, insulation boards etc) any thickness including cover fillets. |
| 9 | Dismantlig timber scantling in any position unframed work 40sqcm and over in section complete all as specified & directed. |
| 10 | Taking down chowkats or frames with Shutters (without taking off shutters from the frame) not exc. 1.5 sq. m each complete all as specified & directed. |
| 11 | Taking down chowkats or frames with Shutters (without taking off shutters from the frame) exc. 1.5 sq. m but not exc. 4 sq. m each complete all as specified & directed. |
| 12 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n exc 50 m and making good surface as in soft/loose soil complete all as specified & directed. |
| 13 | Use & Waste of Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified & directed. |
| 14 | Use & Waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions for square/rectangular rough finished flat surfaces of concrete complete all as specified & directed. |
| 15 | Use & Waste of Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces of concrete complete all as specified & directed. |
| 16 | Material and labour for providing PCC (1:3:6) type C1 using 40 mm graded aggregate as Plinth protection / Path finished the surface even & smooth with out using extra cement all as specified and directed. |
| 17 | M& L for forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade \"A\" complete all as specified. |
| 18 | M&L for Damp proofing course in cement concrete 1:2:4 type B0 , 40 mm thick to horizontal or vertical surfaces complete all as specified. |
| 19 | M&L for RCC 1:1.5:3 type A-1 (using 20 mm graded stone aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete |
| 20 | M&L for RCC 1:1.5:3 type A-1 (using 20 mm graded stone aggregates) nominal mix as in Columns, pillars, piers, posts and struts complete all as specified & directed. |
| 21 | M&L for RCC 1:1.5:3 type A-1 (using 20 mm graded stone aggregates) nominal mix as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified & directed. |
| 22 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified & directed. |
| 23 | M & L for brickwork with subclass \"B\" or locally available best qualityold size bricks, straight or curved on plan exc 6 m mean raduis,built in CM (1:4} as half brick thick wall all as specified & directed. |
| 24 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed |
| 25 | M&L for Mild steel TMT bars 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed |
| 26 | Material and labourfor Mild steel TMT bars 6 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and directed. |
| 27 | S&F for Pre-painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roofcovering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 28 | S&F for Pre-painted galvaume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roofcovering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. |
| 29 | Supply and fix Fe-410- W(Gde- E-250) quality- B MS plates plain cut to required size, forming holes to receive holding down bolt and welded to tubular/square hollow section truss at both ends complete all as specified and directed |
| 30 | Supply and fix mild steel screw bolts 11 to 15 mm dia (machine made) with hexagonal or square heads at one end and screwed at the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 22.50cm and n exc 30cm long complete all as specified and directed |
| 31 | Supply and fix Steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161 - 2014 / IS.4923 - 1997 grade St.-240 complete all as specified and directed |
| 32 | Supply & Fix Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, railings, and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed. |
| 33 | Material and Labour for Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in bed block or hold fast block complete all as specified and directed. |
| 34 | Material and labour for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) on wall surface and finishing even and fair complete all as specified and directed |
| 35 | Material and labour for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) on wall surface with top 5 mm layer mixed with water proofing compound and finishing even and fare complete all as specified and directed.NOTE : Water proofing compound shall be measured & paid separately. |
| 36 | Supply only integral water proofing compound. |
| 37 | M&L for Screed bed or bedding layer of mortar 15 mm thick in CM 1:6 for laying floor finishes complete all as specified & directed. |
| 38 | M& L for Vetrified Ceramic tiles light shade10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust complete all as specified and asdirected . |
| 39 | M&L for Coloured Glazed ceramic tiles in vertical surface 300x450x 7 mm thick joint free set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified & directed. |
| 40 | Material and Labour for applying 1mm thick wall care putty on new or previously untreated plastered surfaces of walls, including preparation, to make the surface even and smooth all as specified and directed. |
| 41 | Material and Labour for applying two coats of acrylic distemper over a coat of alkali resistant primer including preparation of newly plastered surfaces, all as specified and directed. |
| 42 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & directed. |
| 43 | Material and labour for preparation of new or previously un-treated steel or iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed. |
| 44 | Supply and fix 3 ways sliding anodized aluminium glazed window shutter with frame with the following specification all as specified & directed.(a) Window frame 3 track of size 95mmx25mmx1.5mm thick(b) Stiles and rails of size 35mmx25mmx1.5mm(c) 35mmx35x1.5mm T section mullion (d) PVC gasket with 4mm thick tinted glass, incl. aluminium handles with necessary locking arrangement for 02 Nos glazed shutter(e) Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire stapples incl. aluminium handles with necessary locking arrangement for 01 No gauzed shutterNote : Measurement to be taken as overall width and height of window. No shutter or frame to be measured separately. All necessary accessories including tinted glass and stainless steel wire cloth required for assembling and fixing window at proper place complete are deemed to be inclusive. |
| 45 | Providing & fixing false ceiling with semi perforated 12 mm thick micro tegular edged of 10 mm thick square eadgeat all heights with GRG (glass fiber reinforced Gypsum ) false ceiling tiles of size 595/X595 of approved texture design and patter having moisture contain less than 2%, humidity resistance of 99%,NCR 0.50 to 0.75 as per IS 8225, 1987, non combustible as per BS 475 ( Part -IV1970 and light code description unit rate No 429 SUB HEAD 26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85 % minimum to laid in true horizontal level suspended on interlocking metal T grid of hot dipped galvanized iron section of 0.33 mm thick ( galvanized @ 120 gms per sqmincluding both side comprising of main T runner of size 15X 32 mm of length of 3000 mm , cross T of size 15 X 32 mm of length 1200 mm and secondary intermediate crass T of size 15 X 32 of length of 600 mm to form grid module of size 600 X 600 mm suspended from ceiling using galvanized metal sheet item (galvanized @ 80 per sqm ie 50 mm long 8 mm outer dia meter M-6 , fasteners , 6 mm dia fully threaded hanger rod up to 1000 mm length and L shape level adjusters of size 85 X 25 galvanizediron perimeter wall angle of size 24 X24 X 0.40 mm of length 3000 mm to be fixed on perimeter of wall / partition with the help of plastic rawl pluhs at 450 mm centre to centre and 40 mm long dry wall screw . The work shall be carried out as per specification drg and as per direction of Engr-in-Charge. |
| 46 | M&L for 20 mm thick granite (of any type ) work (table rubbed and polished ) in steps ,jambs, pillars ,window cill ,cooking plateform and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed of granite complete all as specified and as directed. |
| 47 | M&L for providing edge moulding to 18 -20 mm thick granite stone of counters vanities etc including polished to edge to give high gloss finished etc complete all as specified and as directed. |
| 48 | S&F 35mm thick plain framed 2nd cl hardwood panelled shutter (two panels ) with lock rail & panel of 9mm BWP commercial ply or 12mm veneered particle with commercial veneering on both face, the size of rail and style as per IS 1003 (Part-1) kiln seasoned and chemically pressed, treated complete incl 15 to 20 mm tapering bedding on one face of second cl hardwood fitted to chowkhats complete all as specified. |
| 49 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of apertue 1.40mm and fixed with stainless steel wire staples complete all as specified. |
| 50 | M & L for applying two coats of synthetic enamel paint over one coat of pink primerincluding preparation of new or previously untreated wood and wood based surfaces Surfaces of any description, not otherwisedescribed, over 10cm width or girth |
| 51 | S&F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed. |
| 52 | Supply and fix 100 mm size stainless steel butt hinges (ISI marked) with stainless steel screws all as specified and directed. |
| 53 | Supply and fix for 150mm extruded Aluminium alloy handles, cast type all as specified & directed. |
| 54 | Supply and fix for 200mm long Aluminium, anodised, barrel tower bolts of extruded section all as specified & directed. |
| 55 | S&F in repairs floor door stopper of aluminium alloy body and tongue,anodised,with hard drawn steel spring of 140 mm size with vulcanised rubber piece. complete all as specified and as directed by Engineer-in-Charge |
| 56 | E & M Division Items |
| 57 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, sockets, lamp holder and conduit etc. removing materials to store fortaking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by EIC.Note:- The damaged surfaces to be made good with plastering& applying colour wash in required coats tomatching with existing surfaces as directed by Engineer-in-charge. Cost of the same deem to be included in quoted rates and nothing extra on this account admissible. |
| 58 | M&L for point wiring with two single core 1.5 Sq.mm size multistranded FRLS copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including PVC Non metatilicconcealed Conduit and conduit accessories,confirming to IS Specifications,concealed in wall, fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed for One light point controlled by one switch. |
| 59 | M&L for point wiring with two single core 1.5 Sq.mm size multistranded FRLS copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including PVC Non metatilicconcealed Conduit and conduit accessories,confirming to IS Specifications,concealed in wall, fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed forOne fan/ exhaust fan point controlled by one switch. |
| 60 | M&L for point wiring with two single core 1.5 Sq.mm size multistranded FRLS copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including PVC Non metatilicconcealed Conduit and conduit accessories,confirming to IS Specifications,concealed in wall, fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed forOne switch socket out let point 5 Amps on independent board |
| 61 | M&L for point wiring with two single core 1.5 Sq.mm size multistranded FRLS copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including PVC Non metatilicconcealed Conduit and conduit accessories,confirming to IS Specifications,concealed in wall, fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed forOne switch socket out let point 5 Amps on same board |
| 62 | M&L for point wiring with two single core 1.5 Sq.mm size multistranded FRLS copper conductor PVC insulated cables and one single core 1.5 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including PVC Non metatilicconcealed Conduit and conduit accessories,confirming to IS Specifications,concealed in wall, fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed for One bell/buzzar point controlled by one bell push independent |
| 63 | point wiring with two single core 4.0 Sq.mm size multistranded FRLS copper conductor PVC insulated cables and one single core 4.0 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including PVC Non metatilicconcealed Conduit and conduit accessories,confirming to IS Specifications,concealed in wall, fixing on ceiling /trusses with suitable clamps , screws etc, including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting switches, sockets, fan regulators etc.,including connecting up and testing , all as specified and as directed for one 3 pin 15 Amp switch socket outlet |
| 64 | Supply and fixswitch modular 5/6 Amp single pole, one way 1 module as specified as directed by EIC. |
| 65 | Supply and fixswitch modular 15/16 Amp single pole, one way 1 module as specified as directed by EIC. |
| 66 | Supply and fix Socketmodular 5/6 Amp single pole, 2/3 pin2 module as specified as directed by EIC. |
| 67 | Supply and fixSocketmodular 6/16 Amp single pole, 2/3 pin2 module as specified as directed by EIC. |
| 68 | Supply and fixUSB charging Socketmodular 5 Amp single pole,as specified as directed by EIC. |
| 69 | Supply and fixBell push modular 6 Amp single pole, one way 1 module as specified as directed by EIC. |
| 70 | Supply and fixing for ceiling rose surface bakelite 65 x 50 mm three terminal. |
| 71 | Supply and fix modular single phase starter 20A with green red push button for AC connection complete with on off testing as per direction by Engr-in-charge. make ABB ITM2MS20 |
| 72 | Supply and fixing lamp holder insulated body with back plate for batten fitting including necessary connection all as dirtected |
| 73 | Supply and fixModular metal flush box 3 module with white cover plate with framefor mounting, switches, sockets, fan regulator as specified as directed by EIC. Note:- (i) Switches, sockets, fan regulator, etc. will be measured and paid seperately under relevent items. |
| 74 | Supply and fixModular metal flush box 2 module with white cover plate with framefor mounting, switches, sockets, fan regulator as specified as directed by EIC. Note:- (i) Switches, sockets, fan regulator, etc. will be measured and paid seperately under relevent items. |
| 75 | Supply and fixModular metal flush box 6 module with white cover plate with framefor mounting, switches, sockets, fan regulator as specified as directed by EIC. Note:- (i) Switches, sockets, fan regulator, etc. will be measured and paid seperately under relevent items. |
| 76 | Supply and fixModular metal flush box 8 module with white cover plate with framefor mounting, switches, sockets, fan regulator as specified as directed by EIC. Note:- (i) Switches, sockets, fan regulator, etc. will be measured and paid seperately under relevent items. |
| 77 | Supply and fixing powder coated sheet metal enclosuresDB, double door, single pole and neutral 8 way 240 Volt fitted with bus bar, DIN channel, neutral link and incoming contact. |
| 78 | Supply and fixing MCB SPN 6-32 Amps240 volts.as specified as directed by EIC. |
| 79 | Supply and fixing MCB SP 6 Amps to 32 Amps 230 Volt as specified as directed by EIC. |
| 80 | S&F powder coated sheet metal enclosures MCCB DB, double door, tripple pole and neutral, 4 way 415 volts fitted with bus bar DIN rail neutral link and incoming contact as specified as directed by EIC. |
| 81 | Supply and fixing MCB TPN 125 Amps 415 volts. 10kAAdjustableoverload setting l &fixed magnetic settingcurrent carrying capacity in theDB complete with connecting testing as per specification |
| 82 | Supply and fixing MCB TPN 63 Amps 415 volts.10 KA \"B\"curve and current carrying capacity in theDB complete with connecting testing as per specification |
| 83 | M&L Sub main wiring with single core FRLS PVC insulated and unsheathed multistranded, FRLS copper conductor cable 1100 volts grade drawn through and incl 20 mm size of ofPVCconduit concealed in wall accessories and fittings on wall. Cable required for connection to DBs shall deemed to be including and shall not be measured separately. Earth wire shall run inside the conduit. (a)02 runs 6 sqmm conductor cable and 01 run of 6 sqmmas earth continuity conductor colour code as specification. |
| 84 | S&FRecces mounting (2\"X2\") 36w LED light fitting,high efficiency PMMA diffuser soft glare free highlightintegrated polycarbonate LED channel with white acrylic cover complete suitable forfixed properly on ceiling and connecting with driver completeto fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit all as directedby Engr-in-Charge |
| 85 | S&F surface mounting rectangular mirror batten tube light fitting, integrated polycarbonate LED channel with white acrylic cover complete suitable for and including lamp LED 1x10 Watt,(2 feet) chargeable min backup 2 hour fixed properly on wall surface and connecting complete from ceilling rose to fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit all as directed. |
| 86 | S&Fbuilding security light LED fitting 25/35 watt 230V AC outdoor type with high pressure die cast aluminum housing and heat resistant , epoxy powder coated dark graphite grey colour finish and prismatic polycarbonate cover with individual LED lences suitable for including lamp LED 25/35 watt, fixed / connect properly at directed location on building with IP 65/66 protection complete |
| 87 | Supply and fixing bracket for street light fittings of any size made out of GI pipe medium grade 25/32 mm dia 1.25 mtr length bend to required size and shape including provision of clamps and fittings in position and two coat of aluminum paint over a coat of red oxide primer all as specified and directed including taking down old bracket. |
| 88 | Supply and fix LED Spot downlight 15W warm white cylinders employ lighting and design configuration to ensure consistent colour point beam angle 36 degree 4000K CCT black or whitemild steel bodytype wallmounted 230 Vcomplete with allaccessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as directed at site complete.Make:-Crompton CDS-200-15-57 HL2NWH |
| 89 | Taking down existing old Ceiling fan and S&FCeiling fan 1200mm sweepsingle phase 230 volts AC, min air delivery 210 CFM with service valve 6.00 BEE 5 star rating with brushless direct current motor (BLDC) withblade ,down roads electronic regulator andcomplete accessories complete fixed properly on wall surface with the provisioning of suitable sizes of rag bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 2.5 Sqmm 3 core and overall PVC sheathed which shall be passed through PVC flexible conduit of length not exceeding 0.50 mtr all as reqd and as directed by Engr-in-Charge.Note:- Taking down Old Ceiling fan deposit toAGE Vairengte E/M Store (not in Schedule of Credit) |
| 90 | Taking down old fan and S&F for Plastic bodyExhaust Fan 250 mm sweep, single phase 230 volts AC, 1200 RPM copper windingfour blade with louver shutters complete fixed properly on wall surface with the provisioning of suitable sizes of rag bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 1.5 Sqmm 3 core and overall PVC sheathed which shall be passed through PVC flexible conduit of length not exceeding 0.50 mtr all as reqd and as directed by Engr-in-Charge. |
| 91 | M & L for building earthing complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level,connected to galavanised iron earth lead by means ofbolt, nut, check nut and washer of galavanised iron wire 4mmas earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work inhard/dence soil, earth pit in PCC 1:3:6 typeC1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs,wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 all as directed by Engr-in-Charge |
| 92 | Supply ,laying and testingin trenches or fixing on wall or passing through pipe 1100 volts grade heavy duty cable XLPE Insulated multi stranded aluminium conductor cross section area 70 sqmm 3 core served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and over PVC sheathed complete as per specification properly clamps on walland connection at end point with all legs ,glands etc complete as per direction by EIC |
| 93 | Supply & laying,tubes, 32mm medium grade, galvanised iron water tubes with screwed socket joint together with and includingall GI fittings connection on waal or floor with clamps digging etc as per site requirement as per Engr-in-Charge |
| 94 | Supply & laying,tubes, 25mm medium grade, galvanised iron water tubes with screwed socket joint together with and includingall GI fittings connection on waal or floor with clamps digging etc as per site requirement as per Engr-in-Charge |
| 95 | M&L for Fan hook fabricatedwith MS Flat 25X6mm 350mmlong 02 nos bend to shapedrilled with holes and MS nut, boltsandwasher of required as per side with one coatof primer and twocoatof paints as per site complete as per direction by EIC |