| 1 | Providing & Fixing Precoated galvanised iron profile /Trapezoidal prifile sheets (Size,Shape and pitch of corrugation as approved by Engineer-In-Charge)manufactured out of 0.50 mm (0.05%)TCT with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyster top coating 15-18 micron. Sheets should have protective guard film of 25 microns minimum to avoid scratches during transportation. The sheet shall be fixed using self drilling/self tapping screws size(5.50-8 x55 mm) with EPDM seal, complete upto any pitch in Horizontal/Vertical or curved surfaces, excluding the cost of purlins,rafters & trussesand including cutting to size and shape whenever required. |
| 2 | Providing and fiixing precoated galvanised steel sheetsroofing accessories 0.50 mm(+0.50%) total coated thickness , Zinc coating 120 grams per sqm as per IS 277, 240 mpa steel grade , 5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns using self drilling/self tapping screws of size ( 5.5-8 x 55 mm with EPDM seal) complete.(A) Ridges plain(500-600 mm). |
| 3 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption\"s less than 0.08% andconformingtoIS:15622ofapprovedmakeinallcoloursand shades, laidon 20mm thick cement mortar 1:4 (1 cement: 4coarse sand)includinggroutingthejointswithwhitecementandmatching pigments etc., complete.Size of Tile 60x60 cm |
| 4 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-Charge12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 5 | Providing and fixing aluminium work for doors, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved mark confirming to IS : 733 and IS : 1285 , fixed with dash fastners of required dia and size , including necessary fillings up of gaps at junctions at top, bottom and sides with required EPDM Rubber / Neoprene gasket etc. Aliminium sections shall be smooth rust free straight metred and jointed mechanically wherever required including clit angle aliminium snap beading for glazing / panneling C.P Brass/ stainless steel screws all complete as per architectural drawing and the directions of Engineering In Charge (Glazing ,panneling dash fasteners to be paid for separately). For shutters of doors , windows and ventilators including providing and fixing hinge/pivots and making provision for fixing of fittings wherever required including the cost of EPDM Rubber / Neoprene gasket required (fitting shall be paid for separately) Power coated aluminium (Minimum thickness of powder coating 50 micron). |
| 6 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 7 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead :With cement mortar 1:4 (1 cement : 4 fine sand) |
| 8 | DISMANTLING WOODEN PARTITION WALL INCLUDING FRAME WORK, COMMERCIAL PLY, DOOR SHUTTER WITH BUTT HINGES, WOODEN BEADING ETC. COMPLETE, AS PER DIRECTION OF ENGINEER IN- CHARGE. LABOUR RATE ONLY |
| 9 | REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS, ROOFS HAVING SLOPE UPTO 15 DEGREE, LANDINGS , BALCONIES, SHELVES, CHAJJAS, LINTELS, BANDS, PLAIN WINDOW SILLS, STAIRCASES AND SPIRAL STAIR CASES UPTO TO FLOOR FIVE LEVEL EXCLUDING THE COST OF CENTERING, SHUTTING AND REINFORCEMENT WITH 1:2:4 ( 1 CEMENT : 2 COARSE SAND : 4 GRADED STONE AGGREGATE 20 MM NOMINAL SIZE). |
| 10 | ReinforcementforR.C.C. workincludingstraightening,cutting, bending, placing in position and binding all complete. Cold twisted bars |
| 11 | Takingoutdoors,windowsandclerestorywindowshutters(steelor wood) including stacking within 50 metres lead: Of area 3 sq. metres and below |
| 12 | Dismantling roofing including ridges, hips valleys andgutters etc., and stacking the material within 50 metres lead of: Asbestos sheet |
| 13 | Finishing walls with water proofing cement paint of required shade : new work(two or more coats applied @3.84kg/10 sqm) |
| 14 | PROVIDING AND APPLYING WHITE CEMENT BASED PUTTY OF AVERAGE THICKNESS 1 M.M. OF APPROVED BRAND AND MANUFACTURER OVER THE PLASTERED WALL SURFACE TO PREPARE THE SURFACE EVEN AND SMOOTH COMPLETE. |
| 15 | WALL PAINTING WITH ACRYLIC EMULSION PAINT OF APPROVED BRAND |
| 16 | Paintingwithsyntheticenamelpaintofapprovedbrandand manufacture to give an even shade :Two or more coats on new work |
| 17 | Centeringandshutteringincludingstrutting,proppingetc.and removal of form for : Suspendedfloors,roofs,landings,balconiesand access platform. |
| 18 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked for doors including cost of cutting floors as required embeding in floors and cover plate with brass pivot and single piece M.S. Sheet outer box with slide plate etc With Brass cover plate |
| 19 | Demolishingcementconcretemanually/bymechanicalmeans including disposal of material within 50 metres lead as per direction of Engineer - in - charge.1:3:6 or richer mix |
| 20 | DemolishingR.C.C.workmanually/bymechanicalmeansincluding stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 21 | Carriage of material by mechanical transport including loading, unloading and stacking:Lime, moorum, building rubbish:Lead 1 KM. |
| 22 | Providingandfixingonwall faceunplasticised RigidPVCrainwater pipes conforming to IS : 13592 Type A including jointing with seal ring conformingtoIS: 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. 110 mm diameter |
| 23 | Providing and fixing on wall face unplasticised - PVC moulded fittings/Accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Shoe (Plain)- 110 mm |
| 24 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 MM |
| 25 | Providing and fixing on wall face unplasticised - PVC moulded fittings/Accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Bend 87.5°- 75 mm bend |
| 26 | PROVIDING AND FIXING BRIGHT FINISHED BRASS 100 MM. MORTICE LATCH AND LOCK WITH 6 LEVERS AND A PAIR OF LEVER HANDLES WITH NECESSARY SCREWS ETC. COMPLETE.(BEST MAKE OF APPROVED QUALITY) |
| 27 | REMOVING DRY OR OIL BOUND DISTEMPER BY SCRAPPING, SAND PAPERING AND PREPARING THE SURFACE SMOOTH INCLUDING NECESSARY REPAIRS TO SCRATDHES ETC. COMPLETE. |
| 28 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 29 | PROVIDING AND FIXING 6 MM DIA. G.I. LEVEL ADJUSTING HANGERS (UPTO 1200 MM LENGTH), FIXED TO ROOF SLABS BY MEANS OF CEILING |
| 30 | Structural steel work riveted bolted or welded in built up section,trusses and framed work including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete. |