| 1 | Civil |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manualmeans over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil , For vertical pipes , walls plinth protection |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering – All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zoneIII) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) for pipe grouting , wall foundation, plinth protection |
| 4 | Providing and constructing concrete block masonry using 150x200x400 mm solid core compact concrete block (Grade C – 50Kg/Cm2 ) in CM 1:6 including all scaffolding, curing, etc. complete For side curtain walls |
| 5 | Centering and shuttering including strutting, propping etc .and removal for walls |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level 1:2:4 (1 cement:2 coarse sand(zone-Ill) derived from natural sources:4graded stone aggregate 20mm nominal size derived from natural sources) |
| 7 | Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads,flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m all kinds of soil |
| 8 | Providing Cement plaster 1:3 (1 cement: 3 coarse sand)finished with a floating coat of neat cement. 12 mm cement plaster |
| 9 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer |
| 10 | Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (Asian Tractor / Jonson Nicholson/Berger) |
| 11 | Supplying and erecting superstructure framework. : The work shall include cutting, threading, welding, hoisting, grinding, finishing, painting joints with zinc rich primer etc. complete for a side height of 3 mt and central height of 4.20 mt. complete as per directions: Gp square or rectangular pipes as aper approved sample for verticals, roof member , struts , purlins as per design at site ( wastage will not be considered) |
| 12 | Providing and fixing in position 50% cut-off green HDPE woven shade net with all edge and over laps, stitching with plastic tape to the edges as instructed at site (shade net as per approved sample and colour) etc., complete as per directions. 75% cutoff HDPE green mono x mono 125gsm monofilament green color shade net) |
| 13 | Supplying fixing G.I. wire including tightening as required and as instructed at site G.I. wire (60 cm c/c both ways for top to hold shade net as directed at site) as per approved sample and thickness only for roof |
| 14 | For roof and for sides,: Providing and fixing 06 mm thick UV Stabilized multiple wall Poly Carbonate Sheet (Sunlite / Tufflite / Polymac / Micropoly or equivalent ) of approved sample with all necessary overlaps, silicon joint sealants, etc complete as per directions. ( wastage will not be considered) |
| 15 | Supplying and fixing as per approved sample aluminium profiles with standard spacings as indicated at site with ss self -threading screws rubber washer wherever required and edge profile and U section beading complete as required and directed at site |
| 16 | Supplying and fixing in position 100mm thick cross fluted cellulose pad (CELDEK) cool cooling pad with necessary cover pipes for water circulation & back flow drain with all aluminium cover all round with return water gutter at the bottom all complete |
| 17 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 18 | Supplying doubled wall PVC tank and placing of the tank below ground level as directed work includes earth work (Sintex / Kaveri / Fusion) 500 lts two nos |
| 19 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge 20 mm nominal dia Pipes (Asrtal / Supreme / Prince ) |
| 20 | Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Flush/ Ruled pointing |
| 21 | Electrical |
| 22 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 23 | Supplying and fixing of 20W LED tube light fittings as required at site. |
| 24 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 25 | Supply and fixing of following switch /socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required |
| 26 | 5/6 amp switch |
| 27 | 15/16 amp switch |
| 28 | 3 pin 5/6 amp socket outlet |
| 29 | 6 pin 15/16 amp socket outlet |
| 30 | 6 Module (200mmX75mm) |
| 31 | SITC of 1 KVA UPS with 42 AH, 12 V SMF Battery set. |
| 32 | SITC of 1 HP, 1 Ph, 220 V Submersible type Pump set with accessories to be connected as per site requirement.(for Foggers). |
| 33 | SITC of 0.5 HP, 1 Ph, 220 V Submersible type Pump set with accessories to be connected as per site requirement.(for Cooling Pad system). |
| 34 | SITC of Electronic and sensor based/Temperature and humidity set up based Misting unit with micro fogging to be connected with auto control Cooling fan pad system and also to micro misting system (drain proof), including electrical control panel, with necessary connections to be fixed inside the net house. As per approved sample Temperature and humidity logger with display memory of One month data (one each) reputed make and model (water proof) as per approved sample |
| 35 | SITC of direct drive 1 Ph/3phase Draft fans for exhaust of 900mm dia with necessary louvers of approved quality and size as suitable for greenhouse as directed by the engineer at site with all necessary control panel having DOL L&T starter and MCB, SPP enclosed in a suitable box with stainless steel mesh, locking facility with all necessary electrical wiring, switches etc complete including integrating with the existing cooling system. |
| 36 | Connecting micro misting system (drain proof), with micro filter unit, return gutter , control valve assembly , PVC flush valve 40MM, plain lateral 16 MM (Class –II), cool pro foggers 5.5X4, 22 lph with accessories, to be fixed to the net house. As per approved sample |
| 37 | Supplying and laying of fallowing sizes of PVC insulated Alluminium conductor wired Armored UG cable on surface by using necessary fittings for fixing, (including earthing and end termination) etc. as required at the site 35 Sq mm x 4 core. |
| 38 | Supplying and fixing of DWC Pipe double walled corrugated high density poly ethylene pipe having corrugation on the outer wall 50 mm and plain surface inner wall of 55 mm sizes conforming to IS14930, with necessary DWC fitting for protection of 1.1 KV grade UG Cable directly in ground at a depth of 2 feet including excavation and refilling on the Soft Soil. |
| 39 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 40 | 10 A Single pole |
| 41 | 20 A Single pole |
| 42 | 25 A Single pole |
| 43 | 32 A Tp and N |
| 44 | Supplying and fixing of 100 Amps open type 4 way copper Bus bar box of size 18” X 18” with cable termination by using copper lugs. |
| 45 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 46 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 47 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |