| 1 | Dismantling galvanised steel sheet roof including ridges, hips, valleys and gutters etc; and stacking the materials with 50 metres lead complete all as specified and directed. |
| 2 | Providing and fixing 0.56mm galvalume colour coated profile sheet with centre to centre pitch of 175mm, depth of 46mm, top crest width of 41mm, bottom valley width of 80mm overall profile width of 1144, cover width 1050mm at all height, levels and locations colour finish galvalume alloy roofing sheets of alloy and dimensions as per IS standard with characteristics of good formability and corrosion resistance complete all as specified and directed. |
| 3 | Providing and spray applying two component hybrid polyurea polyureathane waterproofing system at all levels for terrace waterproofing by the manufacturer or his approved applicator consisting the following operations (Horizontal Surfaces):(a) Dismantling and removing the existing APP layer alongwith protective screed of concrete if any including disposal of malba. |
| 4 | (b) Grinding the surface to remove clinged APP layer and dirt, dust & grease etc; and treating the surface as recommended by manufacturer and there after treated cracks, holes etc; with surface polymer modified cement mortor and ponded with water for 24 hrs for testing of leakage or seepage.(c) Providing and applying by spray or brush two component solvent free rasin / epoxy primer mixed in proportion by volume / weight as recommended by manufacturer over cement concrete surface after 14 days having consumption from 0.20 to 0.40 Kg/Sqm depending on the porosity and undulations of the surface. |
| 5 | (d) Providing and sprinkling sand as recommended by manufacturer over freshly laid primed tacky surface @ 0.25 to 0.4 Kg/Sqm as decided by the Engineer-in-Charge.(e) Over sandy surface providing and spray applying two component hybrid polyurea polyureathane coating system. Solvent free mixed in proportion by volume / weight as recommended by the manufacturer having elongation > 400%. Shore A Hardness > 75 (after 28 days). Tensile stregth of minimum of 10 MPa as per DIN/ASTM and tear strength of minimum 30 N/mm as per DIN 53515 or minimum 45 N/mm as per ASTM D624 and having dry film thickness of two coats shall be minimum 1.5 mm and 20 sec maximum gel time / reaction time. |
| 6 | (f) A layer of non woven polypropylene geo textile of minimum mass / unit area of 120 gsm with an overlap of 50 mm shall be laid over the polyurea / polyureathane coating surface having minimum tensile strength 2.4 KN/m as per ASTM.(g) Providing and laying screed of cement concrete, 1:1.5:3 using 20mm graded aggregate of thickness 30mm. |
| 7 | Providing and spray applying two component hybrid polyurea polyureathane waterproofing system at all levels for terrace waterproofing by the manufacturer or his approved applicator consisting the following operations (Vertical surfaces i.e. upward roof facias / parapet wall):(a) Dismantling the existing cement plaster / APP treated vertical surface including disposal of malba.(b) 15 mm thick cement plaster with cement mortor 1:3 over a coat of cement slurry @ 2 Kg/Sqm.(c) Providing and laying coving in concave shape of cement concrete 1:1.5:3 using 20 mm graded aggregate of size 75 x 75 mm at the junction of vertical wall and horizontal surfaces along the length of wall. |
| 8 | (d) Providing and applying by spray or brush two component solvent free resin / epoxy primer mixed in proportion by volume / weight as recommended by manufacturer over cement concrete surface in dry condition, having consumption from 0.20 to 0.40 Kg/Sqm depending on the porosity and undulations of the surface.(e) Providing and sprinkling washed coarse sand as recommended by manufacturer over freshly laid primed tacky surface @ 0.4 to 0.5 Kg/Sqm as decided by the Engineer-in-Charge. |
| 9 | (f) Over sandy surface providing and spray applying two component hybrid polyurea polyureathane coating system. Solvent free mixed in proportion by volume / weight as recommended by the manufacturer having elongation > 400%. Shore A Hardness > 75 (after 28 Days). Tensile stregth of minimum of 10 MPa as per DIN/ASTM and tear strength of minimum 30 N/mm as per DIN 53515 or minimum 45 N/mm as per ASTM D624 and having dry film thickness of two coats shall be minimum 1.5 mm and 20 sec maximum gel time / reaction time. |
| 10 | Renewing glass pane with putty, glazing clips and nails wherever necessary at building height of 10mtr incluidng racking out the old putty including float glass panes of nominal thickness 5mm (weight not less than 12.5 kg/Sqm) complete all as specified and directed. |
| 11 | Providing and fixing on wall face 110mm diameter unplasticised rigid PVC rain water pipes conforming to IS:13592 type \"A\" including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion single socketed pipes complete all as specified and directed. |
| 12 | Providing and fixing on wall face unplasticised - PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS:13592 type \"A\" including jointing with seal ring conforming to IS:5382, leaving 10mm gap for thermal expansion bend 87.5 110mm bend complete all as specified and directed. |
| 13 | Demolishing brick work in cement mortarmanually / by mechanical means including stacking of serviceable materials and disposal of unserviceable materials within 50 meter lead omplete all as specified and directed. |
| 14 | Demolishing cement concrete of any mix manually / by mechanical means including disposal of materials within 50 metres complete all as specified and directed. |
| 15 | Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:4 complete all as specified and directed. |
| 16 | Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar 1:6 complete all as specified and directed. |
| 17 | Providing half brick masonry with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level in cement mortar 1:4 complete all as specified and directed. |
| 18 | Providing and laying 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size derived from natural sources) in position cement concrete of specified grade excluding the cost of centering and shuttering all work upto plinth level complete all as specified and directed. |
| 19 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. |
| 20 | 15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete all as specified and directed. |
| 21 | 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete all as specified and directed. |
| 22 | 6mm thick cement plaster 1:3 (1 cement : 3 fine sand) on ceiling surface finished with a floating coat of neat cement and thick coat of lime wash on top of ceiling when dry for bearing of RCC slabs and beams complete all as specified and directed. |
| 23 | Repairs to plaster of thickness 12mm to 20mm in CM 1:4 in patches of area 2.5 Sqm and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground complete all as specified and directed. |
| 24 | Distempring two coats on new workwith 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams / litre of approved brand and manufacture of required shade and colour complete all as specified and directed. |
| 25 | Finishing wall new work (two coats) applied @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm with 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS-15489 :2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives complete all as specified and directed. |
| 26 | Finishing wall with acrylic smooth exterior paint on old work in two coats applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 0.90 kg/10 Sqm of required shade complete all as specified and directed. |
| 27 | Finishing wall with acrylic smooth exterior paint on old work in one coat applied @ 0.83 ltr/10 Sqm of required shade complete all as specified and directed. |
| 28 | Removing dry or oil bound distemper, water prooofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches complete all as specified and directed. |
| 29 | Distempering on old work (wall / ceiling) in one coat with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/litre of approved brand over a coat of water thinnable cement primerand manufacturer to give an even shade complete all as specified and directed. |
| 30 | Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite stone slab colour black, chery / ruby Red, area of slab over 0.50 Sqm for kitchen platforms, vanity counters, window cills, facias and similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joint treated with white cement mixed with mateching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to edges to give high gloss finish etc complete at all levels complete all as specified and directed. |
| 31 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregte 40mm nominal size) in pavements, floors, paths etc laid in required slope and camber in panels as required including consolidation finishing and tamping complete all as specified and directed. |
| 32 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20mm nominall size derived from natural sources) of 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth complete all as specified and directed. |
| 33 | Providing and laying double charge vitrified tiles size 600 x 600mm in floor in different size (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved brand & manufacturer, in all colours and shade, laid on 20mm thick cement mortar 1:4 jointing with grey cement slurry @ 3.3 kg/Sqm incluidng grouting the joints with white cement and matching pigments etc., the tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, piler, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 34 | Providing and laying vitrified tiles in different sizes (size of tiles 600 x 600 mm) (thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in all colours & shade in skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/Sqm including grouting the joint with white cement & matching pigments complete all as specified and directed. |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black and size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg/per sqm, incluidng pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 36 | Providing and laying ceramic non skid floor tiles of size 300 x 300 mm or more (thickness to be specified by the manufacturer) of 1st quality confirming to IS:15622 of approved make in colours and shade except white ivory, Grey, fume Red Brown, laid on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/Sqm incluidng pointing the joints with white cement and matching pigment complete all as specified and directed. |
| 37 | Dismantling tiles work in floors and roof laid in cement mortar including stacking materials within 50 metres leadfor thickness of tiles 8mm to 25mm complete all as specified and directed. |
| 38 | Dismantling aluminium / gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable materials and stacking of serviceable materials within 50 metres lead complete all as specified and directed. |
| 39 | Providing and fixing 12.5mm thick tapered edge glass reinforced Gypsum board of size 595mm x 595mm conforming to IS:2095 (Part 3) : 1996 false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from MS sheet and galvanised with zinc coating of 120gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm at 1200mm centre to centre, one flanges fixed to the ceiling with dash fastener 12.5mm dia x 50mm along with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x 50mm of required length with nut & bolts of required size complete all as specified and directed. |
| 40 | Disconnecting damaged over head / terrace PVC water storage tank of any size from water supply line and removing from the terrace incluidng shifting at ground level complete all as specified and directed. |
| 41 | Providing and placing on terrace (at all floor leels) polyethylene water storage tank, triple layered 1000 ltr capacity IS:12701 marked with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but without fittings complete all as specified and directed. |
| 42 | Providing and fixng PTMT ball cock 20mm nominal bore 120mm long, weighing not less than 198 gms of approved quality, colour and make complete with epoxy coated aluminium rod with LP/HP HD platic ball complete all as specified and directed. |
| 43 | Providing and fixing gun metal gate valve 20mm nominal bore with CI wheel of approved quality (screwed end) complete all as specified and directed. |
| 44 | Dismantling 15 to 40mm dia GI pipe internal work exposed on wall including stacking of dismantled pipes (within 50 metres lead) complete all as specified and directed. |
| 45 | Providing and fixing GI pipes 15mm dia nominal bore complete with GI fittings and clamps including making good the walls etc concealed pipe including painting with anti corrosive bitumastic paint cutting chases and making good the wall complete all as specified and directed. |
| 46 | Providing and fixing GI pipes 20mm dia nominal bore complete with GI fittings and clamps including making good the walls etc concealed pipe including painting with anti corrosive bitumastic paint cutting chases and making good the wall complete all as specified and directed. |
| 47 | Providing and fixing water closet squatting pan (Indian type WC pan) White vitreous china orrissa pattern WC, pan of size 580 x 440 mm with integral type foot rests with 100 mm sand cast iron P or S trap, 10 litre low level white PVC flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete includng cutting and making good the walls and floors wherever required complete all as specified and directed. |
| 48 | Providing and fixing white vitreous china pedestal type water closet (European type WC pan) WC pan with ISI marked white solid plastic seat and lid, 10 litre low level white PVC flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required complete all as specified and directed. |
| 49 | Providing and fixing white vitreous china flat back half stall urinal of size 580 x 380 x 350 mm with 5 litre white PVC automatic flushing cistern with Penumatic push cock fittings, standard size CP brass flush pipe, spreaders with unions and clamps (all in CP brass) with waste fittings as per IS:2556, CI trap with outlet gratings and other couplings in CP brass including painting to fittings and cutting and making good the walls and floors wherever required complete all as specified and directed. |
| 50 | Providing and fixing White vitreous china flat back wash basin size 550 x 400mm with CI brackets with single 15mm self closing CP brass pillar taps, 32mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required complete all as specified and directed. |
| 51 | Providing and fixing white vitreous china laboratory sink size 600 x 450 x 200mm with CI brackets, CP brass chain with rubber plug, 40mm CP brass waste and 40mm CP brass trap with necessary CP brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required complete all as specified and directed. |
| 52 | Providing and fixing PVC low level flushing cistern 10 litre capacity white with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete all as specified and directed. |
| 53 | Providing and fixing uplasticised PVC connection 15mm nominal bore, 45 cm length pipe with PTMT nuts, collar and bush of approved and colour complete all as specified and directed. |
| 54 | Providing and fixing CP brass long nose bib cock 15mm nominal bore of approved quality conforming to IS standards and weighing not less 810 gms complete all as specified and directed. |
| 55 | Providing and fixing CP brass angle valves 15mm nominal bore for basin, mixed, geyser, urinal etc; points of approved quality conforming to IS:8931 complete all as specified and directed. |
| 56 | Providing and fixing CP/SS health faucet with flexible tube upto 1 metre long to Eureopean type WC of quality and make complete all as specified and directed. |
| 57 | Providing and fixing 15mm dia stop cock cast brass alloy with capstan head of approved quality and design complete all as specified and directed. |
| 58 | Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP brass screws and washers complete all as specified and directed. |
| 59 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangements of approved quality and colour 600mm long complete all as specified and directed. |
| 60 | Providing and fixing PTMT circular type 125mm nominal dia with 25mm waste hole grating of approved quality and colour complete all as specified and directed. |
| 61 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materails with snap fittings of approved quality and colour, weighing not less than 105 gms complete all as specified and directed. |
| 62 | Providing and fixing PVC waste pipe flexible pipe 32mm / 40mm dia for sink or wash basin and urinal incluindg PVC waste fittings complete all as specified and directed. |
| 63 | Providing and fixing 100 mm inlet and 100 mm outlet sand cast iron S&S trap of self cleansing design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors complete all as specified and directed. |
| 64 | Dismantling old 75mm diameter CI pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at the site lead upto 50 metre complete all as specified and directed. |
| 65 | Dismantling old 100mm diameter CI pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at the site lead upto 50 metre complete all as specified and directed. |
| 66 | Providing and fixing 100 mm dia sand cast iron S&S pipe as per IS:1729 soil waste and vent pipes complete all as specified and directed. |
| 67 | Providing and fixing 75 mm dia sand cast iron S&S pipe as per IS:1729 soil waste and vent pipes complete all as specified and directed. |
| 68 | Providing and fixing bend of required degree with access door insertion rubber washer 3 mm thick, 75 mm dia sand cast iron S&S as per IS:1729 complete all as specified and directed. |
| 69 | Providing and fixing bend of required degree with access door insertion rubber washer 3 mm thick, 100 mm dia sand cast iron S&S as per IS:1729 complete all as specified and directed. |
| 70 | Providing and fixing square mouth S.W gully trap 150 x 100 mm size P type with common burnt clay F.P.S (non modular) bricks of class designation 7.5 brick masonry chamber with water tight C.I cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design class SP-1 complete with C.I grating complete all as specified and directed. |
| 71 | Providing and fixing 100mm dia sand cast iron S&S as per IS-1729 cowls complete all as specified and directed. |
| 72 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc;complete and stacking within 50 metres lead of area 3 Sqm and below complete all as specified and directed. |
| 73 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc;complete and stacking within 50 metres lead of area beyond 3 Sqm complete all as specified and directed. |
| 74 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area 3 Sqm and below complete all as specified and directed. |
| 75 | Providing and fixing factory made PVC door frame of size 50 x 47 mm with wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corner and joined with 02 Nos of 150mm long bracket of 15 x 15 mm MS square, the vertical door frame profiles to be reinforced with 19 x 19 mm MS square tube of 19 gauge, EDPM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using MS screws of 65/100 mm size complete as per manufacturers specification complete all as specified and directed. |
| 76 | Providing and fixing, factory made solid panel PVC door shutter 30mm thick plain PVC door shutter (style) consisting of frame made out of MS tubes for top & bottom tails. MS frames shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail on either side and as insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and directed. |
| 77 | Providing and fixing ISI marked 35 mm thick flush door shutters conforming to IS:2202 (Part-I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including ISI marked stainless steel butt hinges with necessary screwscomplete all as specified and directed. |
| 78 | Providing and fixing aluminium tower bolts 150 x 10 mm, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws complete all as specified and directed. |
| 79 | Providing and fixing aluminium handles 125mm, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws complete all as specified and directed. |
| 80 | Providing and fixing aluminium sliding door bolts 300 x 16 mm, ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with nut and screws complete all as specified and directed. |
| 81 | Providing and fixing aluminium twin rubber stopper hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws complete all as specified and directed. |
| 82 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections for fixed portion powder coated aluminium (minimum thickness of powder coating 50 micron) and other sections of approved make conforming to IS:733 & IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc., aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling CP brass / stainless steel screws, all complete as per the directions of Engineer-in-Charge. Note: Glazing to be measured and paid for separately. |
| 83 | All as per Sl item No 77 above but for shutters of doors, windows & ventilators powder coated aluminium (minimum thickness of powder coating 50 micron) including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required. |
| 84 | Providing and fixing anodised aluminum grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design / pattern with approved standard section and fixed to the existing windows frame with CP barss / stainless steel screws @ 200 mm centre to centre incluidng cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed. |
| 85 | Proving and fixing glazing with float glass panes of 5mm thickness (weight not less than 12.50 Kg/Sqm) in aluminium door, window, ventilator shutters and partitions etc; with EPDM rubber / neoprene gasket etc complete all as specified and directed. |
| 86 | S&F, 12mm thick both side prelaminated particle board to aluminium door, partiion complete all as specified and directed. |
| 87 | Providing and fixing aluminium powder coated 50 micron thickness round shape handle of out dia 100mm with SS screws complete all as specified and directed. |
| 88 | Providing and fixing aluminiuim extruded section body universal type hydraulic door closer (having brand logo with ISI, IS:3564, embosed on the body, door weight upto 36 to 80 kgs and door width from 701 to 1000 mm) with double speed adjustable with necessary accessories and screws complete all as specified and directed. |
| 89 | Providing and fixing brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminum door including necessary cutting and making good complete all as specified and directed. |
| 90 | S&F, venetian blinds (roller type) with all fittings (to be matched with existing pattens) & taking down old venetian blinds complete all as specified and directed. |
| 91 | Providing and fixing in position collapsible steel shutters with vertical channels 20 x 10 x 2 mm and braced with flat iron diagonals 20 x 5 mm size, with top and bottom rail of T-iron 40 x 40 x 6 mm, with 40mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles including applying a priming coat of approved steel primer complete all as specified and directed. |
| 92 | Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc; including welding grinding, buffing, polishing and making curvature (wherever required) and fittings the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc; of required size on the top of the floor or the sides of waist slab with suitable arrangement complete all as specified and directed. Note: Only weight of stainless steel members shall be considered for payment purpose. |
| 93 | S&F, rolling shutters 80 x 1.25 mm MS laths with 1.25mm thick top cover of approved make, made of required size, MS laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangement for inside and outside locking with push and pull operation complete includng the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 Part-I and MS top cover of required thickness for rolling shutters complete all as specified and directed. |
| 94 | Painting on new steel surface (two coats) including a coat of approved steel primer (red oxide primer) with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade complete all as specified and directed. |
| 95 | Painting two coats on new wood work with synthetic enamel paint of approved brand and manufacture to give an even shade including a coat of approved wood primer complete all as specified and directed. |
| 96 | Providing and fixing 18mm thick prelaminated (one side decorative and other side balancing lamination) flat pressed 3 layers or graded particle board (medium density) Grade I, Type II, IS:12823 marked with necessary fixing arrangement and screws incluindg drilling necessary holes for rawl plugs complete all as specified and directed. |
| 97 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead complete all as specified and directed. |
| 98 | White washing on new work (three coats) with lime to give an even shade complete all as specified and directed. |
| 99 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in R.S. Joists in rolling shutters complete all as specified and directed. |
| 100 | Taking down carefully of any type point wiring light, fan, socket or power complete fitting such as switch ceiling rose, pendent, regulator, sockets etc; removing material and making good disturbed surface of wall floor etc; complete all as specified and directed. |
| 101 | M&L for wiring with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, bell push, two way switch - 02 Nos and modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc., as required for one light point controlled by one wayswitch complete all as specified and directed. |
| 102 | All as per Sl item No. 96.00 here-in-before but for one fan point / exhaust fan point controlled by one way switch. |
| 103 | All as per Sl item No. 96.00 here-in-before but for one bell point controlled by one bell push switch. |
| 104 | All as per Sl item No. 96.00 here-in-before but for one 2-way light point controlled by two, 2-way switches. |
| 105 | Wiring for circuit / submain wiring alongwith earth wire with 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire for 5 A socket and highbay light fittings of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 106 | Wiring for circuit / submain wiring alongwith earth wire with 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire for 15 A socket and highbay light fittings of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 107 | Wiring for circuit / submain wiring alongwith earth wire with 2 x 4 sq. mm + 1 x 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 108 | Wiring for circuit / submain wiring alongwith earth wire with 2 x 6 sq. mm + 1 x 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 109 | Wiring for circuit / submain wiring alongwith earth wire with 4 x 6 sq. mm + 2 x 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 110 | Wiring for circuit / submain wiring alongwith earth wire with 4 x 10 sq. mm + 2 x 10 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 111 | Wiring for circuit / submain wiring alongwith earth wire with 4 x 16 sq. mm + 2 x 16 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 112 | S&F, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 Amps modular socket outlet and 5/6 A modular switch, connections etc as required complete all as specified and directed. |
| 113 | S&F, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 and 15/16 Amps modular socket outlet and 15/16 A modular switch, connections etc as required complete all as specified and directed. |
| 114 | S&F, modular switch board containing 04 Nos of 6/16Amps, 6 pin mulitipurpose socket outlet and 16 Amps modular switches on one switch board recessed in wall suitable for terminal boxes for fixing of switch sockets etc, including suitable size modular plates and including all internal electrical connections with copper conductor complete all as specified and directed. |
| 115 | S&F, LED lights fitting 1 x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 116 | S&F, LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 117 | S&F, LED light fitting 30 Watts recessed mounted type 2\" x 2\" feet down lighter, fully diffused, 6500K with high transmitive diffuser suitable for indoor complete with all accessories and making electrical connections as required complete all as specified and directed. |
| 118 | S&F, LED street light 35 W IP66, street light complete with all accessories and including wall mounting GI pipe medium bracket of suitable size and adequate length and clamps and making electrical connections as required complete all as specified and directed. |
| 119 | S&F, LED highbay light fitting160 Watts with wide beam optic with toughened glass complete with all accessories including GI angle iron frame of suitable size and making electrical connections as required complete all as specified and directed. |
| 120 | S&F, LED spot light fitting,10W, 230 volts complete all as specified and directed. |
| 121 | S&F, call bell 230V, AC supply complete with all accessories and making electrical connections as required complete all as specified and directed. |
| 122 | S&F, modular electronic fan regulator 120 W, 230 V, 2 module complete all as specified and directed. |
| 123 | S&F, ceiling rose surface bakelite three terminal, 230 V complete all as specified and directed. |
| 124 | Taking down and dismantling of existing ceiling fan for carryout servicing and paintingwith two coats of synthetic enamel spray painting of approved brand to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safetypins, reinstalling the same and making electrical connections as required complete all as specified and directed. |
| 125 | S&F, MCB SP 6-32 Amps, 10 KA, \"C\" curve240 Volts complete all as specified and directed. |
| 126 | S&F, MCB SPN 40 Amps, 10 KA, \"C\" curve240 Volts complete all as specified and directed. |
| 127 | S&F, MCB FP 63 Amps, 10 KA, \"C\" curve415 Volts complete all as specified and directed. |
| 128 | S&F, MCB DB sheet steel enclosure duly powder coated fixed in recess / flush in wall including MCB DP 25/32 A, 10 KA, 240 V \"C\" curve complete with connections as required complete all as specified and directed. |
| 129 | S&F, VTPN MCCB DB 4 Way, 415V, double door IP 43 protection sheet steel enclosure duly powder coated fixed in recess / flush in wall inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar suitable for MCCB as incommer and MCBs SP/TP as outgoing complete all as specified and directed. |
| 130 | S&F, MCB DB 4 way, TPN, 415V, double door IP 43 protection sheet steel enclosure duly powder coated fixed in recess / flush in wall inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar complete all as specified and directed. |
| 131 | S&F, MCB DB 12 way, SPN, double door, IP 43 protection sheet steel enclosure duly powder coated fixed in recess / flush in wall inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar complete all as specified and directed. |
| 132 | S&F, MCB DB 8 way, SPN, double door, IP 43 protection sheet steel enclosure duly powder coated fixed in recess / flush in wall inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar complete all as specified and directed. |
| 133 | S&F, MCCB FP 125A, 36KA, 415V fixed type with fixing arrangement including cable connections as required site complete all as specified and directed. |
| 134 | S&F, MCCB FP 100A, 25KA, 415V fixed type including sheet steel enclosure of suitable size and fixing arrangement surface / recess including cable connections as required site complete all as specified and directed. |
| 135 | S&F, MCCB FP 63A, 25KA, 415V fixed type including sheet steel enclosure of suitable size and fixing arrangement surface / recess including cable connections as required site complete all as specified and directed. |
| 136 | S&F, PVC conduit of 25mm dia medium grade complete with all accessories in recess / concealed in wall including cutting the wall and making good the surface to match with existing surface complete all as specified and directed. |
| 137 | M&L for fabrication, supply, fixing of remote control motor for existing rolling shutter with automatic level stopping switch button, singIe phase and also provision of power chain crank in absence of power with lifting capacity of motor is 1 Metric Ton with electric connection complete all as specified and directed. |
| 138 | M&L for fabrication, supply, fixing of remote control motor for existing rolling shutter with automatic level stopping switch button, singIe phase and also provision of power chain crank in absence of power with lifting capacity of motor is 0.5 Metric Ton with electric connection complete all as specified and directed. |
| 139 | Earthing with G.I.earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc., with charcoal / coke and salt as required with 25 x 4mm GI strip as earth conductor complete all as specified and directed. |
| 140 | Supply & install, split type air conditioner of capacity 1.5 TR complete with indoor / outdoor complete witil cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 complete all as specified and directed. |
| 141 | Supply & install, split type air conditioner of capacity 2.0 TR complete with indoor / outdoor complete witil cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 complete all as specified and directed. |
| 142 | Supply, installation, commissioning of water cooler fully stainless steel, elctric driven (single phase), having approx storage capacity of 80 ltrs and nominal cooling capcity of 40 ltrs per hour complete all as specified and directed. |
| 143 | S&F, voltage stabilizer of capacity 4 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and directed. |
| 144 | S&F, voltage stabilizer of capacity 5 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and directed. |
| 145 | S&F, voltage stabilizer of capacity 2 KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and directed. |
| 146 | M&L for wiring for circuit / submain wiring 2 x 4 sq. mm + 1 x 4 sq. mm alongwith earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed. |
| 147 | S&F, 20 A, 240 V, SPN industrial type socket outlet with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure on surface or in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc., as required complete all as specified and directed. |
| 148 | S&F, copper piping of size 1/2\" (12.7 mm) including jointing with all accessories from indoor to outdoor unit complete all as specified and directed. |
| 149 | S&F, copper piping of size 1/4\" (6.35 mm) including jointing with all accessories from indoor to outdoor unit complete all as specified and directed. |
| 150 | S&F, copper piping of size 5/8\" (15.87 mm) including jointing with all accessories from indoor to outdoor unit complete all as specified and directed. |
| 151 | S&F, copper piping of size 3/8\" (9.52 mm) including jointing with all accessories from indoor to outdoor unit complete all as specified and directed. |
| 152 | Taking out the existing old Air Conditioners and shifting the same after repairing of the building including gas charging, servicing and all the electrical and gas connection complete all as specified and directed. |
| 153 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade of size 3 core 120 sq mm complete all as specified and directed. |
| 154 | S&F, cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminum conductor cable of size 120 Sqmm complete all as specified and directed. |
| 155 | Supply, laying, testing & commissioning of LT cable XLPE insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade laid in trenches / ducts, fixed on walls, trays, through pipes etc; of 3.5 core; 300 Sqmm cross sectional area complete all as specified and directed. |
| 156 | Supply, laying, testing & commissioning of LT cable XLPE insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade laid in trenches / ducts, fixed on walls, trays, through pipes etc; of 3.5 core; 185 Sqmm cross sectional area complete all as specified and directed. |
| 157 | Supply, laying, testing & commissioning of LT cable XLPE insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade laid in trenches / ducts, fixed on walls, trays, through pipes etc; of 3.5 core; 120 Sqmm cross sectional area complete all as specified and directed. |
| 158 | Supply, laying, testing & commissioning of LT cable XLPE insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade laid in trenches / ducts, fixed on walls, trays, through pipes etc; of 3.5 core; 95 Sqmm cross sectional area complete all as specified and directed. |
| 159 | Supply, laying, testing & commissioning of LT cable XLPE insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade laid in trenches / ducts, fixed on walls, trays, through pipes etc; of 3.5 core; 70 Sqmm cross sectional area complete all as specified and directed. |
| 160 | Supply, laying, testing & commissioning of LT cable XLPE insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade laid in trenches / ducts, fixed on walls, trays, through pipes etc; of 3.5 core; 50 Sqmm cross sectional area complete all as specified and directed. |
| 161 | Supply, laying, testing & commissioning of LT cable XLPE insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade laid in trenches / ducts, fixed on walls, trays, through pipes etc; of 3.5 core; 35 Sqmm cross sectional area complete all as specified and directed. |
| 162 | Supply, laying, testing & commissioning of LT cable XLPE insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade laid in trenches / ducts, fixed on walls, trays, through pipes etc; of 4 core; 25 Sqmm cross sectional area complete all as specified and directed. |
| 163 | Supply, fix, testing & commissioning of indoor type LT panel board CPRI approved suitable for working on 3 phase, 4 wire, AC, 415 Volts, 50 Hz, cubicle type made out of 2 mm thick CRCA sheet steel with IP 52 protection duly powder coated painting in 7 tank process with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors, colour coadedPVC sleeved TPN aluminium bus bar of suitable capacity in the middle the ACB location and both side MCCBs and both the outer side the outgoing cable bus to be provided for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy with supported of angle iron frame 50 x 50 x 6 mm including LED digital Voltmeter, |
| 164 | Ammeter with built in selector switch, CTs of suitable ratio and LED indication lamps R, Y, B and making incoming and outgoing cables with suitable lugs, glands etc and providing PCC foundation and comprising of the following: - Location: Sub Station No. 4ACB 1000 Amps, 4 pole, 50 KA, 415 V, 50 Hz - 01 No (incoming).Onload changeover switch of capacity 630 Amps - 01 No.MCCB 400 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 03 Nos (outgoing). |
| 165 | MCCB 315 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 03 Nos (outgoing).MCCB 200 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 03 Nos (outgoing).MCCB 100 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 03 Nos (outgoing). |
| 166 | Supply, fix, testing & commissioning of indoor type LT panel board CPRI approved suitable for working on 3 phase, 4 wire, AC, 415 Volts, 50 Hz, cubicle type made out of 2 mm thick CRCA sheet steel with IP 52 protection duly powder coated painting in 7 tank process with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors, colour coaded PVC sleeved TPN aluminium bus bar of suitable capacity fixed on suitable insulator all housed in suitable bus bar chamber and cable alley with supported of angle iron frame 50 x 50 x 6 mm including LED digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio and LED indication lamps R, Y, B and making |
| 167 | incoming and outgoing cables with suitable lugs, glands etc; and providing PCC foundation and comprising of the following: - Location: Sub Station No. 4 (2nd Panel)MCCB 500 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 01 No (incoming).Onload changeover switch of capacity 400 Amps - 01 No.MCCB 400 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 01 No (outgoing).MCCB 200 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 03 Nos (outgoing). |
| 168 | MCCB 100 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 03 Nos (outgoing).MCCB 63 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 03 Nos (outgoing). |
| 169 | Supply, fix, testing & commissioning of indoor type LT panel board CPRI approved suitable for working on 3 phase, 4 wire, AC, 415 Volts, 50 Hz, cubicle type made out of 2 mm thick CRCA sheet steel with IP 52 protection duly powder coated painting in 7 tank process with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors, colour coadedPVC sleeved TPN aluminium bus bar of suitable capacity fixed on suitable insulator all housed in suitable bus bar chamber and cable alley with supported of angle iron frame 50 x 50 x 6 mm including LED digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio and LED indication lamps R, Y, B and making |
| 170 | incoming and outgoing cables with suitable lugs, glands etc; and providing PCC foundation and comprising of the following: - Location: Building No 66A.MCCB 350 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 01 No (incoming).MCCB 100 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 02 Nos (outgoing).MCCB 63 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 04 Nos (outgoing).MCCB 32 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 04 Nos (outgoing). |
| 171 | Supply, fix, testing & commissioning of indoor type LT panel board CPRI approved suitable for working on 3 phase, 4 wire, AC, 415 Volts, 50 Hz, cubicle type made out of 2 mm thick CRCA sheet steelwith IP 52 protection duly powder coated painting in 7 tank process with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors, colour coadedPVC sleeved TPN aluminium bus bar of suitable capacity fixed on suitable insulator all housed in suitable bus bar chamber and cable alley with supported of angle iron frame 50 x 50 x 6 mm including LED digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio and LED indication lamps R, Y, B and making |
| 172 | incoming and out going cables with suitable lugs, glands etc; and providing PCC foundation and comprising of the following: -Location: Cabin Panel 1 & 2 (Bldg No. 41 Water Automization Panel - 2).MCCB 400 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 01 No (incoming).MCCB 200 Amps, 4 pole, 26 KA, 415 V, 50 Hz - 02 Nos (outgoing).MCCB 100 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 02 Nos (outgoing).MCCB 63 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 02 Nos (outgoing). |
| 173 | Supply, fix, testing & commissioning of indoor type LT panel board CPRI approved suitable for working on 3 phase, 4 wire, AC, 415 Volts, 50 Hz, cubicle type made out of 2 mm thick CRCA sheet steel with IP 52 protection duly powder coated painting in 7 tank process with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors, colour coaded PVC sleeved TPN aluminium bus bar of suitable capacity fixed on suitable insulator all housed in suitable bus bar chamber and cable alley with supported of angle iron frame 50 x 50 x 6 mm including LED digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio and LED indication lamps R, Y, B and making |
| 174 | incoming and outgoing cables with suitable lugs, glands etc; and providing PCC foundation and comprising of the following: -Location: Bldg No. 41 Water Automization First Floor.MCCB 250 Amps, 4 pole, 26 KA, 415 V, 50 Hz - 01 No (incoming).Onload changeover switch of capacity 250 Amps - 01 No.MCCB 100 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 03 Nos (outgoing). |
| 175 | Supply, fix, testing & commissioning ofIndoor type LT panel board CPRI approved suitable for working on 3 phase, 4 wire, AC, 415 Volts, 50 Hz, cubicle type made out of 2 mm thick CRCA sheet steel with IP 52 protection duly powder coated painting in 7 tank process with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors, colour coadedPVC sleeved TPN aluminium bus bar of suitable capacity fixed on suitable insulator all housed in suitable bus bar chamber and cable alley with supported of angle iron frame 50 x 50 x 6 mm including LED digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio and LED indication lamps R, Y, B and making |
| 176 | incoming and outgoing cables with suitable lugs, glands etc and providing PCC foundation and comprising of the following: -Location: Bldg No. 41, 2nd Floor.MCCB 400 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 01 No (incoming).MCCB 350 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 01 No (outgoing).MCCB 200 Amps, 4 pole, 26 KA, 415 V, 50 Hz - 01 No (outgoing).MCCB 63 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 01 No (outgoing).MCCB 32 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 01 No (outgoing). |
| 177 | Supply, fix, testing & commissioning of indoor type LT panel board CPRI approved suitable for working on 3 phase, 4 wire, AC, 415 Volts, 50 Hz, cubicle type made out of 2 mm thick CRCA sheet steel with IP 52 protection duly powder coated painting in 7 tank process with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors, colour coadedPVC sleeved TPN aluminium bus bar of suitable capacity fixed on suitable insulator all housed in suitable bus bar chamber and cable alley with supported of angle iron frame 50 x 50 x 6 mm including LED digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio and LED indication lamps R, Y, B and making |
| 178 | incoming and outgoing cables with suitable lugs, glands etc; and providing PCC foundation and comprising of the following: -Location: Bldg No. 41, PPG Section.MCCB 400 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 01 No (incoming).Onload changeover switch of capacity 400 Amps - 01 No.MCCB 250 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 02 Nos (outgoing).MCCB 200 Amps, 4 pole, 26 KA, 415 V, 50 Hz - 01 No (outgoing).MCCB 160 Amps, 4 pole, 26 KA, 415 V, 50 Hz - 01 No (outgoing).MCCB 63 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 05 Nos (outgoing). |
| 179 | Supply, fix, testing & commissioning of indoor type LT panel board CPRI approved suitable for working on 3 phase, 4 wire, AC, 415 Volts, 50 Hz, cubicle type made out of 2 mm thick CRCA sheet steel with IP 52 protection duly powder coated painting in 7 tank process with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors, colour coaded PVC sleeved TPN aluminium bus bar of suitable capacity fixed on suitable insulator all housed in suitable bus bar chamber and cable alley with supported of angle iron frame 50 x 50 x 6 mm including LED digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio and LED indication lamps R, Y, B and making incoming and outgoing.Location: Back side of Computer section. |
| 180 | MCCB 350 Amps, 4 pole, 36 KA, 415 V, 50 Hz - 01 No (incoming).Onload changeover switch of capacity 250 Amps - 01 No.MCCB 200 Amps, 4 pole, 26 KA, 415 V, 50 Hz - 02 Nos (outgoing).MCCB 125 Amps, 4 pole, 26 KA, 415 V, 50 Hz - 01 No (outgoing).MCCB 100 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 02 Nos (outgoing).MCCB 63 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 02 Nos (outgoing). |
| 181 | Supply, fix, testing & commissioning ofIndoor type LT panel board CPRI approved suitable for working on 3 phase, 4 wire, AC, 415 Volts, 50 Hz, cubicle type made out of 2 mm thick CRCA sheet steel with IP 52 protection duly powder coated painting in 7 tank process with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors, colour coadedPVC sleeved TPN aluminium bus bar of suitable capacity fixed on suitable insulator all housed in suitable bus bar chamber and cable alley with supported of angle iron frame 50 x 50 x 6 mm including LED digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio and LED indication lamps R, Y, B and making |
| 182 | incoming and outgoing cables with suitable lugs, glands etc; and providing PCC foundation and comprising of the following: -Location: Bldg No. 41 Wksp Area - 02 No\"s & Bldg No 66 - 01 No.MCCB 200 Amps, 4 pole, 26 KA, 415 V, 50 Hz - 01 No (incoming).MCCB 100 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 01 No (outgoing).MCCB 63 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 03 Nos (outgoing).MCCB 32 Amps, 4 pole, 16 KA, 415 V, 50 Hz - 04 Nos (outgoing). |
| 183 | S&F, MCCB 630 Amps, 4 pole, 50 KA, 415 V, 50 Hz and making connections complete all as specified and directed. |
| 184 | S&F, MCCB 200 Amps, 4 pole, 36 KA, 415 V, 50 Hz and making connections complete all as specified and directed. |
| 185 | S&F, MCCB 100 Amps, 4 pole, 30 KA, 415 V, 50 Hz and making connections complete all as specified and directed. |
| 186 | S&F, MCCB 63 Amps, 4 pole, 16 KA, 415 V, 50 Hz and making connections complete all as specified and directed. |
| 187 | S&F, MCCB 40 Amps, 4 pole, 16 KA, 415 V, 50 Hz and making connections complete all as specified and directed. |
| 188 | S&F, sheet steel enclosure made out of CRCA sheet factory made suitable for 630 Amps, FP MCCB fixed with flush in wall complete all as specified and directed. |
| 189 | S&F, sheet steel enclosure made out of CRCA sheet factory made suitable for 200 Amps, FP MCCB fixed with flush in wall complete all as specified and directed. |
| 190 | S&F, sheet steel enclosure made out of CRCA sheet factory made suitable for 100 Amps, FP MCCB fixed with flush in wall complete all as specified and directed. |
| 191 | S&F, sheet steel enclosure made out of CRCA sheet factory made suitable for 63 Amps, FP MCCB fixed with flush in wall complete all as specified and directed. |
| 192 | S&F, sheet steel enclosure made out of CRCA sheet factory made suitable for 32 Amps, FP MCCB fixed with flush in wall complete all as specified and directed. |
| 193 | S&F, the LED sign board of board size : 1 ft x 4ft and inner iron frame of size 1\"\" x 2\"\" x 2\"\" depth with backside cover with GI sheet & silicon fixed in ACP panel of grey colour with computerised script CNC hollow router cutting acrylic letters with colour, wall thickness 1\"\" in white colour LED\"s complete with drivers, controllers and other accessories and shall be inner high definition with water proof and neccessary fixing arrangrment including making connections as required complete all as specified and directed. |
| 194 | S&F, cable tray of size 150 mm width x 50 mm depth x 1.6 mm thickness perforatted type powder coating complete with fixing arrangement on ceiling walls complete all as specified and directed. |
| 195 | Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc., with charcoal / coke and salt as required with 25 x 5mm GI strip as earth conductor complete all as specified and directed. |
| 196 | S&F, GI strip 25 x 5 mm on surface or in crecess for connection complete all as specified and directed. |
| 197 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft / loose soil for foundation of poles, structures, stay rods, laying of underground cable etc; complete all as specified and directed. |
| 198 | Returning, filling in, including spreading, leveling, watering and well ramming in layers each not exceeding 25cm thick using soil complete all as directed. |
| 199 | Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 200 | Supply & spreading, dry river sand in trenches / transformer yard / two pole structure yard for cable protection complete all as specified and directed.Note: Punned thickness only shall be measured for payment purpose. |
| 201 | Supplying & laying, un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 202 | Supplying & laying, un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 203 | Cutting to existing steel tubing for alterations upto 50 mm GI tubing complete all as specified and directed. |
| 204 | Pipes galvanized, “medium class”, supplied and laid complete including fittings 50 mm (2.0”) dia complete all as specified and directed. |
| 205 | Pipes galvanized, “medium class”, supplied and laid complete including fittings 40 mm (1.5”) dia complete all as specified and directed. |
| 206 | Pipes galvanized, “medium class”, supplied and laid complete including fittings 25 mm (1.0”) dia complete all as specified and directed. |
| 207 | Pipes galvanized, “medium class”, supplied and laid complete including fittings 15 mm (1/2”) dia complete all as specified and directed. |
| 208 | S&F, cast copper alloy stop valve, 50 mm size screwed down, high pressure with butterfly handle screwed both end for iron pipe complete all as specified and directed. |
| 209 | S&F, cast copper alloy stop valve,25 mm size screwed down, high pressure, with butterfly handle screwed both end for iron pipe complete all as specified and directed. |
| 210 | Ball brass valves, 15 mm size high pressure with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail