| 1 | Dismantling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coveringsany gauge, thickness,as in valley gutter, ridge of roof, wall and cladding etc complete all as specified and directed. |
| 2 | Demolition of brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articlescomplete all as specified and directed. |
| 3 | Dismantling timber scantling 40 sqcm & over in section, any position in unframed workcomplete all as specified and directed. |
| 4 | Dismantling weather boarding, any description, fixed in any position with screwscomplete all as specified and directed. |
| 5 | Material and labour for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. |
| 6 | Material and labour for brick work with sub class \"B\" bricks, straight or curved on plan excto any radius in half brick thick walls built in built in CM 1:4 complete all as specifed and directed. |
| 7 | Material and labour for clean sawn 2nd class hardwood as in timber scantlings for replacement pieces of rafter, purlin or other truss member etc fixed at its old position with necessary arrangement as required at site and directed by engineer-in-charge complete all as specified and directed. |
| 8 | Material and labour for 2nd class hard wood weather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30mm laps complete all as specified and directed. |
| 9 | Supply and fix in repairs, suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 32 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic)in & including a grid of GI system duly suspended with 4mmdia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid complete all as specified and directed. |
| 10 | Supply and fix pre-painted hot dip aluminium zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick (total coated thickness), any patteren corresponding to IS 15965: 2012 of durability class 3, four (4) coat atmospheric classification category 3, coating class AZ 150 of an approved colour havingb yield strength of 550MPa as in roof covering/wall cladding, fixed with self tapping screws as complete all as specified and as directed |
| 11 | Supply and fix pre-painted hot dip aluminium zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick (total coated thickness), any patteren corresponding to IS 15965: 2012 of durability class 3, four (4) coat atmospheric classification category 3, coating class AZ 150 of an approved colour havingb yield strength of 550MPa as in roof covering/wall cladding, fixed with self tapping screws as specified and as directedNote: To be executed for provison of ridges and hips, valley etc complete all as specifed and as directed |
| 12 | Material and labour for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to fair faces of brick or concrete wall surfaces, top layer 5 mm thickmixed with water proofing compound (@ 200 ml/50 Kg weight of cement or as per manufacture\"s instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note :Water proofing compoundto be measured and paid separately. |
| 13 | Material and labour for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed |
| 14 | Supply only liquid water proofing compound |
| 15 | Material and labour for preparation of newly plastered surface of wall andapplying a coat of alkali resistant primer and two coats of acrylic distemper complete all as specified and directed. |
| 16 | Material and labour for preparation of newly plastered surface of walls and aapplying two coat of acrylic exterior weather coat paint (Weather proof paint with quality of dust guard, anti algal and anti fungal paint with minimum 05 years performance warranty over a coat of approved primer over 1mm thick wall care putty of same manufacturer complete all as specified and directed. |
| 17 | Material and labour for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with Creosote oil complete all as specified and directed. |
| 18 | Material and labour for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed. |
| 19 | Material and labour for preparation of old steel or iron surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paints complete all as specified and as specified anddirected. |
| 20 | Material and labour for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 21 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, includingfixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. |
| 22 | Taking down ceiling/exhaust fan including connection wires carefully removal to store in safe custody and refixing the same in original position after servicing includingball bearing, bush etc ( if required)complete all as specified and as directed. |
| 23 | Material and labour for Point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Casing and Caping with all accessories including fabricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One light or fan point controlled by one 5 Amps switch one way complete all as specified and as directed. |
| 24 | Allas per item No 23 here-in-before butOne bell/buzzer point controlled by one push button on the same board with other switches or independent with cablescomplete all as directed. |
| 25 | Allas per item No 23 here-in-before butfor One 3 pin 5 Amp switch socket outlet on independent board |
| 26 | Allas per item serial No 23 here-in-before but for One 3 pin 5 Ampsocket outlet on same board with other switches. |
| 27 | Allas per item No 23 here-in-before but wiringwith 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly. |
| 28 | Material and labour for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFR-LSH cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC rigid conduit on walls/ceiling (concealed),with MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulators etc. including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for one light or fan point controlled by one 5 Amp switch one way complete all as specified and as directed. |
| 29 | Allas per item No 28 here-in-before butOne bell/buzzer point controlled by one push button on the same board with other switches or independent with cablescomplete all as directed. |
| 30 | Allas per item No 28 here-in-before butfor One 3 pin 5 Amp switch socket outlet on independent board |
| 31 | Allas per item serial No 28 here-in-before but for One 3 pin 5 Ampsocket outlet on same board with other switches. |
| 32 | Allas per item No 28 here-in-before but wiringwith 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly. |
| 33 | Supply and fix modular switch 1 way 6 amp, 1 module complete all as specified and as directed |
| 34 | Supply and fix modular switch 1 way 16 amp, 1 module complete all as specified and as directed |
| 35 | Supply and fixmodular socket, 6 Amp 2/3 pin combined, 2 module complete all as specified and as directed |
| 36 | Supply and fix modular socket, 16 Amp 2/3 pin combined, 2 module complete all as specified and as directed |
| 37 | Supply and fix modular Bell push 6A, 1 module complete all as specified and as directed |
| 38 | Supply and fix modular fan regulator,120 W, 2module complete all as specified and as directed |
| 39 | Supply and fix switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed |
| 40 | Supply and fix in repair switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed |
| 41 | Supply and fix Bell push switch, flush type, 5 Amps 230 volt complete all as specified and as directed |
| 42 | Supply and fix in repair Bell push switch, flush type, 5 Amps 230 volt complete all as specified and as directed |
| 43 | Supply and fix in repair socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed |
| 44 | Supply and fix socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed |
| 45 | Supply and fix in repair switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed |
| 46 | Supply and fix switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed |
| 47 | Supply and fix in repair switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed |
| 48 | Supply and fix switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed |
| 49 | Supply and fix lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as specified and as directed |
| 50 | Supply and fix in repair lamp holder insulated PVC/ Polycarbonate/ bakelite body, with back plate suitable for batten fitting or PVC round or squre box, complete all as specified and as directed |
| 51 | Supply and fix stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed |
| 52 | Supply and fix in repair stepped type electronic fan regulator, two module size, flush type complete all as specified and as directed |
| 53 | Supply and fix in repair ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed |
| 54 | Supply and fix ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed |
| 55 | Supply and fix call bell Ding Dong AC. 230 volts,single pole complete all as specified and as directed |
| 56 | Supply and fix modular white cover plate with frame, 1 module complete all as specified and as directed |
| 57 | Supply and fixmodular white cover plate with frame, 3 module complete all as specified and as directed |
| 58 | Supply and fixmodular white cover plate with frame, 4 module complete all as specified and as directed |
| 59 | Supply and fixmodular white cover plate with frame, 6 module complete all as specified and as directed |
| 60 | Supply and fixmetal flush box 3 module complete all as specified and as directed |
| 61 | Supply and fixmetal flush box 4 module complete all as specified and as directed |
| 62 | Supply and fix metal flush box 6 module complete all as specified and as directed |
| 63 | Taking down carefully by unscrewing from boards/outlet boxes,fittings and fixtures such as switches, sockets,ceiling roses,lamp holders,brackets,ceiling fitting ,bulkhead fitting,tubelight fitting and regulators etc for reuse at site or carring to the store ( To be measured only when found serviceable in all respect complete for reuse) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed |
| 64 | Supply and fixing in repair LED lights fitting 1x 20W, 220V, AC decorative batten type connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed |
| 65 | S & F in repair LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed |
| 66 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed |
| 67 | Supply and fix in repair wall decorative fixtures in durable body and designer mesh in gold finish suitable for 9W LED lamp of B22, including lamp of 9watt complete all as specified and as directed |
| 68 | Supply and fix in repair/replacement LED 60 W building secruity light made up of pressure die cast housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia upto 43 mm complete all as specified and as directed |
| 69 | Material and labour in repair forbuilding secruity light bracket made out of 40 mm bore light grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape for fixing street light luminaries all as directed, length of GI Pipe shall not be less than 2.0 mtrs complete all as specified and directed. |
| 70 | Disconnecting the main power supply to distribution box and make a proper dressing of SPN/TPN/VTPN MCB/MCCB DBs ofpre-connected MCBsby changingscrew of DB cover ,earth wire and other necessary connecting items and dressing of wires with the help of cable tie inside the distribution box after completion supply power complete all as specified and directed. |
| 71 | Supply and fix in repairfactory made, sheet steel distribution boards, TPN, 4 Way, IP -43 double door,with provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed |
| 72 | Supply fix in repair MCB DB of sheet metal enclosure double door SPN 8 way IP-43 with 200 A rated bus barand grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed |
| 73 | Supply and fix in repairMCB Tripple pole & neutral 40 to 100 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series rupturing capacity providing in DB complete all as specified and as directed |
| 74 | Supply and fix in repairMCBs, SPN upto 40 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA ,C-series marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and as directed |
| 75 | Supply and fix in repair MCBs, SP 6 to 32 Amps In accordance with IS/IEC 60898-1, 240 V, 50 Hz, 10 kA,C-series marked fixing in DBs (DBs catered separately in this Schedule) complete all as specified and as directed |
| 76 | Dressing of pre-wired casing caping/PVC conduit by changing Casing caping /PVC conduit and necessary connecting items (such as flexiable conduit ,screws etc) complete all as specified and directed. |
| 77 | Material and labour for Sub main wiring with 2 runs of 6.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit. |
| 78 | Material and labour for Sub main wiring with 2 runs of 4.0 sqmm, single core,FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core FR-LSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. Note: 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit. |
| 79 | Material and labour for plate earthing completewith galvanizedmild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrodeat one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm boreGIpipe medium gradewith all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I. |
| 80 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core complete all as specified and as directed |
| 81 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 82 | Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punnedthickness shall be measured and paid) |
| 83 | Material and labour for bricks sub class ‘B’ brick old size for cable protection laid in flat in trenches over the cable perpendicular to the direction of cable complete all as specified |
| 84 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and directed. |
| 85 | Removing of excavated soil not exc 50cm & depositing where as directed at a level n.exc 1.5m above starting point complete all as specified and directed. |