| 1 | Dismantaling asbestos cement sheets(corrugated, semicorrugatd) in roof coverings complete all as specified and directed. |
| 2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screws complete all as specified and directed. |
| 3 | S&F Pre-painted galvatume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering / clading to waall , fixed self tapping screwscomplete all as specified and directed. |
| 4 | Dismantling mild steel or wrought iron work in roof trusses,gratings etc and similar work complete all asdirected |
| 5 | M&L for mild steel work in roof trusses,purlins,rafters,wind ties,crane gantries,posts,rails and fastenings and heavy bracket framing (Beam,Tee,Angle,Channel or Flat sections) including distance pieces,cleats etc complete all as specified and directed. |
| 6 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxideprimer, complete all as specified and directed. |
| 7 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc,) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed. |
| 8 | S & F for Aluminiumanodised snap grid frame work for false ceiling comprising of following section for making partitions of 605 X 605 mm size fixed to walls with rawl plugs and screws and hang to roof with s 6 mm dia. G.I. (upto1200mm length) adjusting levelfixed to roof slabs by means ofceilling cleats made out of G.I.flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm long complete all as specifiedsize of main tee shall be :-(i) 36.5mmx25mmx1.4mm thick, Weighing 0.24Kg/Rm(ii) Cross Tee 23.5mmx36.4mmx1.4mm thick Weighing 0.191 Kg/Rm and (iii) Wall angle 40mmx25mmx2mm thick. Weighing 0.36 Kg/Rm |
| 9 | S & F 4 mm thick non asbestos fiber designer ceiling (E-board classic) board / tiles for insulation and accoustic purpose, 600 X 600 mm size fixed in ceilingwith and including dusting of surface complete all as specified and directed |
| 10 | S&F in repairs 5mm thick hollow PVC Sheet wall Panelling (sand wiched between the longitudinal grid in PVC Sheet)any pattern fixing at site with PVC beading/fillet complete all as specified and directed |
| 11 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc complete all as specified and directed |
| 12 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding6m mean radius, built in CM (1:6) complete all as specified and directed |
| 13 | Taking down cement plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water etc.&removing rubbish to a disance not exc 250m complete all as specified and directed. |
| 14 | M & Lfor applying 15 mm thick rendering using ready mix plaster bags in CM 1:4 on brick / concrete surfaces of external walls finished even and fiar, using water proofing compound @ 3% by weight of cement or as per manufacturer instructions, complete all as specified and directed. Note:- Water proofing compound shall be measured and paid seperately |
| 15 | Supply only integral water proofing compound complete all as specified & directed. |
| 16 | M&L for preparation of newly plastered surfaces of wall and applying two coats of weather proof exterior emulsion over a coat of primer complete all as specified and directed. |
| 17 | M & L for 15 mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, surface finishedeven & smooth with using extra cement complete all as specified and directed. |
| 18 | M&L for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed |
| 19 | M&L for 3 mm thick applying a layer of puttyon wall surfaces including cornics etc for proper levelling of plastercomplete all as specified and directed. |
| 20 | M&L for complete removal of existing treatment , plastered or un-plastered surfaces of walls and applying two coats of weather proof exterior emulsion over a coat of primer complete all as specified and directed. |
| 21 | M&L for complete removal of existing treatment , plastered or un-plastered surfaces of walls and applying two coats of oil bound distemper white or tinted over a coat of primer complete all as specified and directed. |
| 22 | M & L for oldpainted surface to steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described with one coats of synthetic enamelincluding preparation of surfaces complete all as specified and directed. |
| 23 | M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed. |
| 24 | Demolition of cement concrete (unreinforced)in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) Complete all as specified and directed. |
| 25 | M&L for 25 mm thickCement concrete type-B-0 1:2:4 (12.5 MM graded aggregate) as subbase in floors all as specified and directed |
| 26 | S&FVitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or colouredcement over 15mm screed bed in CM 1:6 complete all as specified and directed. |
| 27 | S&FVitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or colouredcement over 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 28 | M & L for non skid ceramic coloured /printedtiles 7 to 8 mm thick (square / Rectangular)area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm in floorsetc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles, laid over screed bed or bedding layer 15mm thick in cement mortar(1:6) for laying floor finishes Complete all as specified and directed. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as directed. |
| 30 | M & L for non skid ceramic coloured /printedtiles 7 to 8 mm thick (square / Rectangular)area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm in skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles,10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 31 | M & L for glazed ceramic coloured / printed tiles 450mm x 300mmX7mm thick, on vertical surfaces set and jointed in neat cement slurry and pointed in white/coloured cement to match the tiles,over rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 for backing of Dado/ Skirting& vertical Tiles complete all as specified and as directed. |
| 32 | M&L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed |
| 33 | M & L for 75 mm thick PCC (1:3:6) type C2 using 40mm graded stone aggregate as in plinth protection finishing the surface even and smooth without using extra cement Complete all as specified and directed. |
| 34 | Taking down chowkats or frames with shutters (without taking off shutters from the frame)not exc 1.5 sqm each complete all as specifed & directed. |
| 35 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4.0 Sqm each complete all as specifed & directed. |
| 36 | M & L for Anodised aluminium Powder Coated (of Approvedcolour ,Thickness or powder coating not less than 50 micron) door Shutter, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including frame of chowkhats, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium Complete fittings as required complete all as specified and directed. |
| 37 | S&F factory made three track three shutter sliding window with frame incl stainless steel fly proof wire mesh having 0.56mm nominal dia of wire and average width of aperture 1.18mm & 5.5 mm thick glass (As approved by GE) panes fixed (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 (+) (-) 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension uPVC white colour sliding glazed window comprising uPVC multi chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 (+) (-) 0.2 mm thick alvanized mild steel section made from roll forming porcess of required length (shape & size according to uPVC profile) including appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing grame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Rate inclusive of (Single/ double glass panes, wire mesh,frames and silicon sealent and shall not be paid separately) |
| 38 | S&F powder coated approved colour anodised aluminium partition with sash bars, aluminium sections weighing 0.55 Kg/mtr (minimum) incl fixed with , clips, frame , necessary joining cleats, glazing clips, neoprene rubber gasket with aluminium beading screws suitable anodised fittings such as hinges, handles including powder coated anodised aluminium frame with one or more rebates including S&F 5.50 mm thick plain/tinted glass complete all as specified and directed. |
| 39 | S&F in repairs 20mm Dia Aluminium alloy anodised curtain rod decorative fancy type with brackets complete all as specified & directed. |
| 40 | M&L for framed work such as grills, angle grating etc. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, railings and similar work confirming to Fe-410-O or Fe-310-O, complete all as specified and directed |
| 41 | M & L for hard core of gauge not exc. 63mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed. |
| 42 | M&L 75 mmthick cement concrete 1:4:8 type D-2 finished fair and even as in sub base Complete all as specified and directed. |
| 43 | M&L for chequred cement concrete tiles of size 300x300x25 mm thick coloured rubber pressed glossy finish, set and jointed in neat cement slurry and pointed in white or colour cement to match the surace of tiles in foor/steps, over 15 mm thick screed bed or bedding layer in CM 1:6 complete as all specified and directed. |
| 44 | M&L for Sand filling under interlocking tiles or in foundations including watering and consolidation complete all as specified and directed |
| 45 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006of 60 mm thickness M-35 Grade with grey cement complete all as specified and directed |
| 46 | M&L for Providing cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) as in copings,platform,kerbs etc including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed |
| 47 | Removing demolished material exceeding 250 M but not exceeding 500M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 48 | Taking down carefully any type of battens or conduit point wiringwith conduit (light, fan, socket or power) complete including fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, pendent light fittings, MCBs / isolators, fan regulators, tube light fittings etc removing material from site and making good disturbed surfaces of walls, ceilings etc including two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed |
| 49 | Material and labour for point wiringwith 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, stranded, FRLS PVC insulated, unsheathed, copper conductor cable in and including PVC concealed conduit of any size/dia complete with all accessories/fittings, brass screws, washer etc, sunk zinc coated pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated stranded copper conductor cable, unsheathed and connected to common earth and earth duly complete all as specified and directed for the followings:- |
| 50 | All as described ser item no 49.00 here-in-before but one tube light/Bulb/ street light point controlled by one, one way switch 05 / 06 Amps. |
| 51 | All as described ser item no 49.00 here-in-before but one 3 pin, 05 / 06 Amps socket outlet point on independent board controlled by one, one way 05 / 06 Amps switch. |
| 52 | All as described ser item no 49.00 here-in-before but one 3 pin, 05 / 06 Amps socket outlet point on same board controlled by one, one way 05 / 06 Amps switch. |
| 53 | All as described ser item no 51.00 here-in-before but with 2.5 Sqmm nominal cross sectional area copper conductor cable for one 15 / 16 Amps socket outlet point on independent board. |
| 54 | All as described ser item no 51.00 here-in-before but with 4sqmmmulti stranded PVC insulated, unsheathed copper conductor,FR, cable in and including in rigid PVC conduit 20 mm dia or higher medium grade. |
| 55 | S&Fswitch piano flush type, 05 / 06 Amps single pole, one way 240 volts complete all as specified & directed |
| 56 | S&F insocket outlet 5 pin, 05 / 06 Amps flush type 240 volts complete all as specified & directed |
| 57 | S&F of socket outlet 3 pin, 05 / 06 Amps and 3 pin 15 / 16 Amps (2 in 1 Multipurpose) 240 volts complete all as specified & directed |
| 58 | S&F inswitch piano flush type, 15 / 16 Amps single pole, one way 240 volts complete all as specified & directed |
| 59 | S&F lamp holder (Angular / Straight), insulated body, with back plate complete all as specified & directed |
| 60 | S&F Led lamp 9/10 watt complete all as specified & directed |
| 61 | S&F LED tube light fitting T/5 surface mounting poly carbonate batten 240 volts 20 watts, 6500K complete all as specified & directed. |
| 62 | S&F of ceiling rose, 3 phase/PVC/polycarbonate isolated body complete all as specified & directed |
| 63 | S&F 1x36/40W LED Building security lightenergy saving & environmental friendly long life luminaire with high power LEDs as light source and electronic driver including security light brackets of 32 mm dia GI pipe medium grade upto 1.2 mtr long bend to shape at 100-120 degree including flat iron clamps and Suitable nuts and bolts grouted in wall including all material required for fitting all as specified and directed. |
| 64 | S&F in repairs LED Recess mounted, ceiling panel, 2\"x2\", 36 watts, 240V light fitting with heat exchanger unitcomplete all as specified & directed |
| 65 | M&L for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. |
| 66 | S&F sheet metal enclosure double door, single pole and neutral, AC, 240 volts, 8 way, with 200 Amps rated copper bus bar and IP - 43 protection with metal double door and flush to wall including all cutting on wall and making good including two coats of white/colour washing/distempering etc to match the existing disturbed surfaces complete all as specified & directed. |
| 67 | S&F MCB, SP, AC, 240 volts \"C\" series capacity of 06 to 40 Amps, 10kA and making connections complete all as specified & directed. |
| 68 | S&Fin repairsMCB SPN 40 Amps 10 KA, \"C\" series, 240 volts complete all as specified and directed. |
| 69 | Supply,install, Split AC ( hot and cold ) complete with cordless remote control unit and with cooling and heating function with standard accessories of capacity 1.5 TR, BEE 5 star rated complete all as specified & directed |
| 70 | S & F and grouting in wall sheet metal enclosure factory fabricated with single pole & neutral with a two pin and earth plug top and socket complete with one single pole MCB 20 Amps 240 volts complete all as directed |
| 71 | M&L for submain wiring along with earth wire using 2X4.0 sq mm(colour coading) + 1X2.5 sqmm earth wire(green colour) of single core PVC insulatedmultistranded copper conductor1100 Volts grade FRLS type in and including PVC conduit medium grade ISI markedwith all fittings and accessories 25 mm dia(ISI Marked)such as bend ,junction boxes, short piecesof suitable sizecomplete all as specified & directedNote:- Two run of 4.0 sq mm cable and one run of 2.5 sq mm cable and one run of PVC conduit medium grade will be measured as one unit. |
| 72 | S&F for MCB SP32 Amps 10 KA,\"C\" seriescomplete all as specified and directed. |
| 73 | S&FVoltage stabilizer for automatic operation,single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with out voltage stabilized at20 volts with accuracy of± 2.5%and of capacity 3.0 KVA complete all as specified & directed |
| 74 | M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level steel earth plate connected with GI wire 04mm dia by means oflug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No.3 of SSR part I connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipemedium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 150mm center to center both way with suitable lifting handle and pit / chamber in PCC 1:3:6 type C1 , Angle iron 40x40x5mm frame for pit cover including testing on completioncomplete all as specified and directed. |
| 75 | Taking down existing ceiling fan of any size, CeiIing cable end,dismentalling blades ,makeone set ofthree blades and keep them safe to deposited to E/M yard complete all as specified & directed |
| 76 | S&F fan ceiling complete with blades, down rods, electronic regualtor and accessories ,230V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE.Five Star rated with Brushless direct current motor (BLDC) complete all as specified & directed |
| 77 | supply ,laying commissioning ,testing of XLPE under ground LT cable 1100 volts grade of size 25 sqmm 4 core armoured PVC sheathed with aluminium conductor heavy duty laid in trench ,fixing on wall ,under road crossing through proctection pipe etc complete all as specified and directed including taking down old LT UG cable complete all as specified & directed |
| 78 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying of Cable or Pipe etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ losse soil and leveling of bottom surface to required level complete all as specified and as directed. |
| 79 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft/ losse soil complete all as specified and as directed. |
| 80 | Supply and spreading clean fine dry river sand in trenches for cushioning of under ground cable/ cable duct complete all as specified and as directed.Note: Only punned thickness shall be measured for payment purpose complete all as specified & directed |
| 81 | Supply and laying brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat,size 230mm x 115mmx 75mm, all as directed. |
| 82 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting pointin soft/ losse soil complete all as specified and as directed. |
| 83 | S&F in repairs, GI medium, grade tubing 40mm dia laid in trenches, road crossing , pasing through pipe or laid in wall/pole complete all as specified & directed |
| 84 | Excavation in trenches in soft/lose soil n.exc. 1.5M wide & n exc 1.5M deep for laying of GI/CI pipe line & getting out including forming bottom surface complete all as specified & directed |
| 85 | Disconnecting and Taking out old existing GI pipe and connecting of any description / grade and any position of trenches / under floors/ on walls etc including connecting fitting / accessoriese and fixtures such as bend, union, elbow socket etc. all as directed and specified for the following size of pipe :- |
| 86 | All as described ser item no 85.00 here-in-before but 40/ 50mm dia bore |
| 87 | All as described ser item no 85.00 here-in-before but 25mm dia bore |
| 88 | S & FGI tubing, medium grade, 50 mm bore ISI marked complete with all fittings, laid in trenches or laid under floors, fixed on walls with and providing clamps etc complete all as specified & directed |
| 89 | S & F GI tubing, medium grade, 25 mm bore ISI marked complete with all fittings, laid in trenches or laid under floors, fixed on walls with and providing clamps etc complete all as specified & directed,. |
| 90 | M & L for 25 mm Gun metal gate valve with iron wheel head screwed both ends for iron pipe including testing complete all as specified & directed |
| 91 | M&L for making joint to existing CI/DI line incld making hole of desired size if required along with reducer and other accessories etc complete all as specified & directed |