| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed. |
| 2 | S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, fixed with self tapping screwsupto the height of 15 m as specified and directed. |
| 3 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding, to wall, eaves board and roof bottom , fixed with self tapping screwsupto the height of 15 m as specified and directed. |
| 4 | S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, Eaves board and roof chajja and similar work con- forming to Fe.290.Gde-E-165upto the height of 15 m complete all as specified. |
| 5 | Dismantling Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 6 | S&F Anodised aluminium snap grid frame work for false ceiling all as specified 605 x 605mm complete all as specified and directed. |
| 7 | S&FProviding and fixing Gypsum Board 10mm thick decorative type in ceiling fixed with screw as per manufacturers instructions all as specified |
| 8 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 9 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concretesurfaces with water proofing compound @2% by weight of cement and finished surface even and smooth without using extra cement including necessary scaffolding etc. (WPC paid seprately) complete all as specified and directed. |
| 10 | Supply only WPC complete all as specified and directed. |
| 11 | M & L 15mm thick rendering in cement mortor 1:6 on fair faces of brick work and finishing surface even and smooth without using extra cement as specified. |
| 12 | M&L for applying two coat of exterior emulsion weather proof paint over one coat of exterior wall primer incl. preparation of surface of new plastered surface of walls complete all as specified and directed by Engr-in-Charge. Make Asian ACE or equivalent complete all as specified and directed.. |
| 13 | M&L Applying two coats of Distemper oil emulsion, white or tinted over 2 mm thick wall care putty on new wall surface including preparation of surface all complete and as specified. |
| 14 | M&L for complete removal of existing treatment and applying two coat of oil bound distemper over 2mm thick birla white putty including preparation of surface complete all as specified and directed. |
| 15 | M&L for complete removal of existing treatment and applying two coat of exterior emulsion weather proof paint over one coat of exterior wall primer incl. preparation of surface of old decorated walls etc , properly making of v shape crakes and filling of all crakes with crake sealof walls complete all as specified and directed by Engr-in-Charge. Make Asian ACE or equivalent complete all as specified and directed. |
| 16 | M&L for complete removal of existing treatment from Ceiling (any number of layers) by scrapping with steel scrappers or any other means, including filling depressions of scrapped surfaces and applying two coats of oil bound distemper over and including a coat of 3mm thick wall care putty includingpreparation of surfaces complete all as specified and directed.Note: The time difference between one coat and two coat will be decided by Engineer-in-Charge. |
| 17 | M&L for applying one coat of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface complete all as specified and directed. |
| 18 | Applying one coat of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface complete all as specified and directed.. |
| 19 | Applying two coats of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of pink primer complete all as specified and directed. |
| 20 | Taking down chowkat or frames exc 1.5 sqm but n exc 4.0 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed. |
| 21 | Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 22 | Taking down Shutters of any description n exc 1 sq.m each complete all as specified and directed. |
| 23 | Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each complete all as specified and directed. |
| 24 | S&F 2nd class hardwood Plain, solid, straight, chowkats & frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed. |
| 25 | S&F 30mm thick Glazed & skeleton shutters, open rebated & prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut & mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); to chowkats complete all as specified and directed. |
| 26 | S&F 30 mm thick Flush shutters, solid core construction, with particle board core & plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified. |
| 27 | S & FSolid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening complete all as specified and directed. |
| 28 | M & L Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to complete all as specified and directed.the stiles & rails with suitable PVC sheet beading, and joined together with solventcement, suppling & fixing in the frame at site as per specification & drawing. |
| 29 | S&F in stainless steel Butt hinges 75mm size, medium weight, complete all as specified and directed. |
| 30 | S&F in stainless steel Butt hinges 125mm size, medium weight complete all as specified and directed. |
| 31 | S&F in extrudedAluminium alloy handles 150mm size, cast type, anodised complete all as specified and directed. |
| 32 | S&F in Aluminium, anodised, barrel tower bolts 150mm long of extruded section complete all as specified and directed. |
| 33 | S&F Sheet glass 4.0mm thick, ordinary quality & glazing with oil putty in square n exc 0.5 sq.m in each pane including hacking out old broken glass (any thicknesss, size,quality or description) from metal frame inlcuding punching or drilling out old glazing pins/spring clips & providing & fixing new ones complete all as specified and directed. |
| 34 | S&F in repair Galvanised mild steel wire cloth, 0.56 nominal dia of wire & average width of aperture 1.18mm with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 35 | S&F 20mm bore mild steel cromium plated curtain rods, suitable for door/windows curtain with incl necessary fancy type dooms as approved by GE, and fitted to each end, brackets and fixed to wall complete all as specified and directed. |
| 36 | Dismantling, floor, hearth or wall tiling including CM bedding (but not backing), removing serviceable tiles to store & rubbish off the premises as specified and directed. |
| 37 | S&F Coloured Non Skid ceramic tiles7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm,in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:6) as specified and directed. |
| 38 | S&F coloured Glazed ceramic tiles in vertical surfaces350x250mmx7mm/450x350x7mm thickset and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in CM(1:4) on fair face of brick or concrete surface complete all as specified and directed. |
| 39 | S&Fin repair vitreous china wash down water closet (pedestal pattern) pan, white(excluding fixing bolts, flushing cistern and flush pipe) etc.. completeall as specified and as directed. |
| 40 | S & F plastic seat cover white closed pattern with flat bottom and cover and mild CP aluminium hinging device all as specified and directed. |
| 41 | S & F in repair PVC 10 ltrs capacity low levelflushingcistern complete set including flush pipe all as specified and directed. |
| 42 | S & F in repair health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 43 | S& F 600 x 450 mm bevelled edge mirror or alu/metal frame of selected quality glass mounted on 6 mm thick PVC bldg board fixed with wooden plug with chromium plated brass screw and cup washer all as specified and directed. |
| 44 | S&F MS Grating doom 100 mm dia(min. weight 25 gms) complete all as specified and directed. |
| 45 | S&F for Rotational moulded polyethylene 500Ltr water storage tanks(cylindrical vertical with closed top)hoisted and fixed in position including dismantling all as specified and directed |
| 46 | S & F Ball valves 15mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe & fixed. (min weight 15mm-142 gms) all as specified and directed. |
| 47 | S & F in repair 20mm dia gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed. |
| 48 | Taking up or down steel tubing and connections, 15mm bore including cleaning for refixing or removal to store complete all as specified and as directed. |
| 49 | Taking up or down steel tubing and connections, 20mm bore including cleaning for refixing or removal to store complete all as specified and as directed. |
| 50 | M&L Lagging to pipes used in internal water supply or plumbing all round with, 25mm thick bonded mineral wool pre-formed mineral wool pre-formed `SNAP ON\" pipe secions of density 144 Kg/cum conforming to IS 9842 on pipe of internal dia 20 mm complete all as specified and directed. |
| 51 | M&L 16mm outer dia for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as pecified and directed. |
| 52 | M&L 20mm outer dia for 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as pecified and directed. |
| 53 | Cutting chases, pinning in brickwork and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girthcomplete all as specified and as directed. |
| 54 | S & F in repair 15mm bib tap fancy type chromium platedwith crutch or butterfly handle screwed for iron pipecomplete all as specified and directed. |
| 55 | S & F in repair 15mm angle cock angular type cromium plated fancy type , screwed down , high pressure,with crutch or butterflyhandles complete all as specified and directed. |
| 56 | S & F in repair 15mm 2 in one angle cock angular type cromium plated fancy type , screwed down , high pressure,with crutch or butterflyhandles complete all as specified and directed. |
| 57 | S & F PVC connection pipe 15mm size with PTMT nuts of length 600mm all as specified and directed. |
| 58 | S&F Towel rail 600mm long of PTMT fixed with & including CP brass screws & wooden/plastic cleats (min. weight 190gms) complete all as specified and directed. |
| 59 | M & L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed. |
| 60 | S & F 110 mm dia unplasticised PVC pipes of pressure rating 10kgf/sqcm fixed complete to walls, ceilings or in floors etc, any type of pipe all as specified and directed. |
| 61 | S & F 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and directed. |
| 62 | Ditto all as per item above but 75mm dia complete all as specified and directed. |
| 63 | S & F 110 mm dia PVC (SWR) branch piece, double, (double Y) equal or unequal all as specified and directed. |
| 64 | S & F 110 mm dia PVC (SWR) bend any radius complete all as specified and directed. |
| 65 | Ditto all as per item above but 75mm dia complete all as specified and directed. |
| 66 | S&F PVC (SWR), junction single, (Single T) equal or unequal 110mm dia provided with eccess door complete all as specified and directed. |
| 67 | Ditto all as per item above but 75mm dia complete all as specified and directed. |
| 68 | M & L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and directed. |
| 69 | S & F 110 mm dia PVC (SWR) vent cowl all as specified and directed. |
| 70 | Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level)(unreinforced) complete all as specified and directed. |
| 71 | M&L 75 mm thick Cement concrete type B2 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and as directed. |
| 72 | M&L for 25 mm cement concrete type B0, 1:2:4(12.5 mm graded aggregate) complete all as specified. |
| 73 | Taking down copper / alluminium point wiring (light, fan, socket or power) complete by removing all switches, socket, ceilling rose, pendent etc., excluding light fitting and making good the distributed surfaces as existing surfaces. |
| 74 | Taking down old and UNSV submain wiring any size of two core including earthwire complete including batten/ conduit and making good the distributed surfaces to match the existing surfaces. |
| 75 | Taking down old and UNSV, DB any type including changeover, fuses, MCBs etc., after removing all connection and making good the distributed surfaces to match the existing surfaces. |
| 76 | Material and Labour for concealed point wiring using FRLSH PVC Insulated,unsheathed, multi stranded copper conductor cable 1.5 sqmm, drawn through medium grade rigid PVC conduits of 19/20 mm diameter. This includes all conduit fittings such as tees, bands, sockets and junction boxes, along with a 1.5 sq mm FRLSH PVC insulated, unsheathed copper conductor for Earth continuity. Provide necessary arrangements to accomodate Modular flush boxes, complete all work as specified and directed. |
| 77 | All as per the item no 76 above but 5 Amp socket outlet on independant board all as specified and directed by Engr-in-charge. |
| 78 | All as per the item No.76 above but for one socket outlet 15 Amps on Independent board using cable (2.5 Sq mm for Phase & neutral and 2.5 Sq mm for Earthing) complete all as specified and directed by Engr-in-Charge. |
| 79 | Supply & fixing of DBs for MCB TPN double door, 4 way, 415 Volts, AC supply, with 200 Amperes rated Bus Bar, Earth Bar & Neutral Bar, IP-54, IS-8623, sheet metal enclosure complete all as specified and directed |
| 80 | Supply & fixing of DBs double door SPN-8 way, 230 volts, AC supply, with 100 Amp rated Bus Bar, Earth Bar & Neutral Bar, IP 54, IS-8623, sheet metal enclosure complete all as specified and directed. |
| 81 | Supply & fixing of MCB TPN 100 Amperes, 415V, 10 kA, AC supply, \"C\" curve miniature circuit breaker (MCB) all as specified and as directed. |
| 82 | Supply & fixing of SPN 63 Amperes, 240V, 10 kA, AC supply, \"C\" curve miniature circuit breaker (MCB) all as specified and as directed. |
| 83 | Supply & fixing of MCB SP 6 to 32 Amperes, 240V, 10 kA, \"C\" curve, AC supply all as specified and as directed. |
| 84 | Supply & fixing of MCB SPN 40 Amperes, 240V, 10 kA, \"C\" curve, AC supply all as specified and as directed. |
| 85 | S&F for switch Modular type single pole one way 5 amps 240 volts, with one module, complete all as specified and directed. |
| 86 | S&F for Modularswitch socket combination 2 in 1, 5 pin, 6 amp flush type with 3 Module complete all as specified and directed. |
| 87 | Supply and fixing LED street light fitting 60 Watts 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete |
| 88 | S&F for Modular switch socket combination 2 in 1, 5 pin, 15 amp flush type with 3 Module complete all as specified and directed. |
| 89 | S&F for White cover plate with frame of 1/2 Module as specified and directed. |
| 90 | S&F for White cover plate with frame of 3 Module as specified and directed. |
| 91 | Supply and fix Metal Flush box for 1/2 Module as specified and directed. |
| 92 | Supply and fix Metal Flush box for 3 Module as specified and directed. |
| 93 | S&F ceiling rose 3 terminal size 50x 65 mm surface type complete all as specified and directed. |
| 94 | S&F of 1x20 Watts LED 6500K (4 ft) decorative ultra slim square profile linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, extruded aluminium body heat shrink, provided for efficient dissipation and integrated electronic driver complete with lamp complete all as specified and directed. |
| 95 | S&F in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watts, 6500K, 220 V AC decorative type with driver holder & LED lamp including connecting up with 3 core flexible copper conductor cable of suitable size complete. |
| 96 | M&L of Sub main wiring complete, two run of 6 sqmm and one run of 1.5 sqmm with copper conductor, multi stranded, FRLSH, PVC insulated and sheathed, 1100 Volts grade, incl drawn through PVC suitable size conduitcomplete all as specified and directed.. |
| 97 | M&L for replacement of Earthing complete with GI earthplate 60x60cmx6mm thick electrode and 4mm dia GI wire as earthing lead.burried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified and as directed by Engr-in-Charge. |
| 98 | Disconnecting carefully existing Geyser 15/25 Ltr any type and the same is servicing properly, replacement of defective spare parts including rubbing andtwo coat of existing colour paint and re-fixing properly (including screws, nut bolts and pvc connection) and testing completely all as specified and directed. |
| 99 | Disconnecting carefully existing ceiling fan 1200/1400 mm any type and the same is servicing properly, replacement of defective spare parts including rubbing andtwo coat of existing colour paint and re-fixing properly (includingcanopy, nut bolts)andtesting completely all as specified and directed. |
| 100 | Notes :- Amount of Credit Schedule for Schedule \"A\" Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. |