| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 2 | M&L for Vitrified ceramic light shade tiles double charged of 10mm thick and area of each tiles exceeding 0.42 Sqm not exceeding 1.00 Sqm for flooring using 3 mm thick spacer with epoxy grouting over 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 3 | M&L for Non skid coloured ceramic tiles 7 to 8 mm thickmatt finish(square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm,in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile including screed bed 15 mm thick in CM (1:6) complete all as specified and directed. |
| 4 | Demolition of plain cement concrete (unreinforced) in ground floor and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed. |
| 5 | M&L 75 mm thick cement concrete type B-2,1:2:4 (40 mm graded stone aggregate) for plinth protection complete all as specified and directed. |
| 6 | M&L for Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ for thickness of slab 100mm below complete all as specified and directed. |
| 7 | Taking down cement plaster from brick or stone including raking out joints, hacking for keys, scrubbing down with water etc, wall of any description complete all as specified and directed. |
| 8 | M&L for 10mm thick cement plaster in CM 1:6 on brick work or concrete surfaces rendering is to be even & smooth without using extra cement on internal walls complete all as specified and directed. |
| 9 | M&L for 15mm thick cement plaster in CM 1:4 on brick work or concrete surfaces rendering is to be even & smooth without using extra cement on external wall complete all as specified and directed. |
| 10 | M&L for Rendering 10mm thick in CM (1:3) on concrete surfaces (ceiling) finished even and smooth without using extra cement complete all as specified and directed. |
| 11 | M&L for Keyed pointing in Cement mortar 1:4 to random or polygonal rubble complete all as specified and directed. |
| 12 | M&L for new wall surface applying waterproof cement based putty @ 300 Gm (undiluted) per Sqm of average thickness 1 mm over the putty surface with mechanical wall sander having mechanical vacuum mechanism with RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust and applying two coats of interior acrylic emulsion paint over one coat of interior wall primer using airless spary technology with max two working pressure of 3300 PSI and capable of operating single spray gun with max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying acrylic emulsion should be able to spray in hard to reach area and penetration of acrylic emulsion on the surface etc. by skilled labour as per following steps complete all as specified and directed:-(a) Mix the putty powder by adding water as per manufacturer instructions and mix with putty mixer with the mixing capacity of min 2.50 kg putty per minute.(b) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI.(c ) Allow 6-8 hrs time to dry the putty surface. |
| 13 | M&L for new wall surface applyingtwo coats of exterior acrylic emulsion paint (Apex) over one coat of exterior wall primer using airless spray technology with max two working pressure of 3300 PSI and capable of operating single spray gun with max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying acrylic emulsion should be able to spray in hard to reach area and penetration of acrylic emulsion on the surface etc. by skilled labour as per manufacturer instructions complete all as specified and directed. |
| 14 | Complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7\"/9\" to make the surface free from dust, loose paint etc by skilled labour and applying waterproof cement based putty @ 300 Gm (undiluted) per Sqm of average thickness 1 mm over the putty surface with mechanical wall sander having mechanical vacuum mechanism with RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust and applying two coats of interior acrylic emulsion paint over one coat of interior wall primer using airless spray technology with max two working pressure of 3300 PSI and capable of operating single spray gun with max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying acrylic emulsion should be able to spray in hard to reach area and penetration of acrylic emulsion on the surface etc. by skilled labour as per following steps complete all as specified and directed:-(a) Mix the putty powder by adding water as per manufacturer instructions and mix with putty mixer with the mixing capacity of min 2.50 kg putty per minute.(b) Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI.(c ) Allow 6-8 hrs time to dry the putty surface. |
| 15 | M&L for Preparation of new plastered surfaces and applying three coats of white wash on ceiling surfaces complete all as specified and directed. |
| 16 | M&L for preparation of old painted steel surface of any description, over 10cm in width or girth, not otherwise described and applying two coat of Synthetic enamel over one coat red oxide on roof sheet/steel window complete all as specified and directed. |
| 17 | Complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7\"/9\" to make the surface free from dust ,loose paint etc by skilled labour and applyingtwo coats of exterior acrylic emulsion paint (Apex) over one coat of exterior wall primer using airless spray technology with maximum two working pressure of 3300 PSI and capable of operating single spray gun with maximum material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying acrylic emulsion should be able to spray in hard to reach area and penetration of acrylic emulsion on the surface etc. by skilled labour as per manufacturer instructions complete all as specified and directed. |
| 18 | S&F 110 mm Dia PVC(SWR) Pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and walls including taking down old pipes complete all as specified and directed. |
| 19 | S&F PVC (SWR) bends 110 mm dia in any radius with access door etc complete all as specified and directed. |
| 20 | Taking down door chowkhats or frames exceeding 1.50 sqm but not exceeding 4.00 sqm complete all as specified and directed. |
| 21 | Taking down shutters of any description exc 1.00 Sqm and n.exc 2.00 Sqm, complete all as specified and directed. |
| 22 | M&L plain solid straight chowkhats 2nd class hard wood and frame, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 23 | Cutting holes in brick walls built in CM for inserting hold fast and making good dismantled portion in CM 1:3 or PCC 1:2:4 (type B0) using 12.5 mm graded aggregate, depth of embedded portion of hold fast not exceeding half brick complete all as specified and directed. |
| 24 | S&F Powder coated anodised aluminium frame with all fixing arrangements for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc aluminium section of powder coating not less than 50 micron complete all as specified and directed. |
| 25 | S&F Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats and locking arrangement, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings complete all as specified and directed. |
| 26 | M&L Factory made, 35 mm thick, panelled shutter second class hard wood, plain framed, hammer marked, with lock rail. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 27 | S&F Butt hinges of size 100mm extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed. |
| 28 | S&F for brass, sliding door bolt 250 mm long with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed. |
| 29 | S&F for brass, barrel tower bolt 150mm with cast or sheet barrel and of extruded section rolled or cast bolts and fixed complete all as specified and directed. |
| 30 | S&F for extruded brass handle 150mm fabricated type polished complete all as specified and directed. |
| 31 | S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor 150 mm size of cover plate complete all as specified and directed. |
| 32 | M&L for preparation of new or previously untreated wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 33 | S&F sheet plane glass ordinary quality 4mm thick and glazing with oil putty in square n.exc 0.50 Sqm in each pane fixed with aluminium window and ventilator complete all as specified and directed. |
| 34 | All as item No.33 above but figured glass pin head type complete all as directed and specified. |
| 35 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width or aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 36 | S&F Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 37 | M&L for preparation of new or previously untreated surfaces of steel and iron of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel painting over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 38 | M&L for rendering 15mm thick (average) in cement mortar 1:4 on roof surfaces mixed with water proofing compound as per manufacturer\"s instructions, finished even and smooth without using extra cement complete all as specified and directed.Note:- supply only of water proofing compound will be measured and paid separately under relevant item. |
| 39 | Supply only approved integral water proofing compound complete all as specified and directed. |
| 40 | M&L for laying/fixing TPO membrane of non flammable water proofing of roof which shall be a 1.50 mm thick loose laid membrane using FOSROC Proofex ORG membrane or its equivalent in STP/CIPY/SIKA/PIDILITE DR FIXIT, in layers overlapped to achieve a minimum weld of 110mm. Hot air welding can be either hand applied or by means of automatic machines and the roll either end are overlappedwith 110mm are in staggered position and the membrane shall be laid over the layers of non woven geotextile fibre. The separation layer provided to prevent the mechanical abrasion and and cushioning between the fosroc proofex ORG and the concrete sub structure. The termination of Fosroc Proofex ORG by aluminium strip anchoring. Note: Work shall be executed by authorized applicator with prior experience of more than 5 years on applying similar system complete all as specified and directed. |
| 41 | Taking down existing unserviceable point wiring of any type/ size of light/fan/socket/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area complete all as specified and directed. |
| 42 | Taking down existing unserviceable light fittings, security light fittings, bulk head fittings, fall ceiling light fittings etc. from any height of building complete all as specified and directed. |
| 43 | Taking down existing unserviceable Distribution boards with MCB\"s/MCCB\"s of any capacity complete all as specified and directed. |
| 44 | Taking down earthing material, plate and pipe etc from 2.25 mtrs depth complete all as specified and directed. |
| 45 | M&L for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20 mm bore with conduit accessories for Modular surface wiring mount on wall or fixed on ceiling/roof/truss/columns etc, including provision of branded modular PVC terminal box of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards any size of modules for housing modular switches, sockets, fan regulators etc and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch complete all as specified and directed.Note(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. |
| 46 | All as per Sl item No 45 above but for One ceiling fan/exhaust fan point controlled by one switch through modular regulator complete all as specified and directed. |
| 47 | All as per Sl item No. 45 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent modular board complete all as specified and as directed. |
| 48 | All as per Sl item No. 45 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same modular board complete all as specified and as directed. |
| 49 | M & L for Point wiring complete with two runs of 4 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20 mm bore with conduit accessories for Modular surface wiringmount on wall or fixed on ceiling/roof/truss/columns etc, including provision of branded modular PVC terminal box of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards any size of modules for housing modular switches, sockets, etc and provn of 4 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one 15 Amps socket outpoint independent boardNote(1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth. |
| 50 | S&F single pole Modular switch 1 way 6 Amps, 1 Module complete all as specified and as directedNote:(i)All light/fan switches shall besymbol embossed (light/fan) typecomplete all as specified and as directed.(ii) All switches for sockets shall be LED indicator type. |
| 51 | S&F single pole Modular switch 1 way 16 Amps, 1 Module with red LED indicator complete all as specified and as directed. |
| 52 | S&F Socket modular type multipurpose 2/3 Pin, 6 amps, 230 volts 2 Module complete all as specified and directed. |
| 53 | S&F Socket modular type multipurpose 3/6 Pin, 16 amps, 230 volts 2 Module complete all as specified and directed. |
| 54 | S&F Modular ceiling fan regulator stepped socket size, 2 module suitable to work on 230 volts complete all as specified and as directed |
| 55 | S&F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed |
| 56 | M&L for LED batten light fitting 20 Watts 4 feet surface / wall mounted aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. |
| 57 | M&L for LED security light fitting 25 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant, efficacy complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 42 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enamel paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in all respect complete all as specified and directed. |
| 58 | S&F MCB SP 6 to 32 Amps 240 volts C type with rupturing capacity 10 KA complete all as specified and as directed. |
| 59 | S&F MCB SPN 40 to 63 Amps 240 volts C type with rupturing capacity 10 KA complete all as specified and as directed. |
| 60 | S&F sheet metal enclosure MCB DB SPN 8 way double door with 100 amps rated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed. |
| 61 | M&L for removing defective ceiling fan from the site, rewinding of the ceiling fan of any sweep upto 1400mm complete with equivalent new super enamelled copper wire as per existing gauge and weight as per manufacturer\"s design and instructions including varnishing complete including taking down, transportation, assembling back and refixing all as specified and as directed. Note : 1.The items are to be removed from the site to betaken for rewinding from MES stores and returned to MES stores after necessary repair works. 2. The transportation for the same is inclusive of the rate quoted. |
| 62 | Taking out defective capacitor and supply and fix new capacitor of 2.5 mfd of approved make with holding clamp for various makes of ceiling fans complete all as specified and as directed. |
| 63 | S&F rigid PVC conduit of 20/30 mm dia ISI marked complete all as specified and as directed. |
| 64 | S&F rigid PVC casing capping of suitable size as per the size requirement complete all as specified and as directed. |
| 65 | M&L in repairs of Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GIearth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate).Note :(a)Earthing value should be less than 5 ohms.(b)If desired value of earth resistance not achieved during testing, the earthing work shall be redone by the contractor at free of cost to achieve the desire value of earthing resistance. The rate quoted by the contractor deemed to be inclusive of the provision. |