| 1 | Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 100 metres lead of : G.S. Sheet (DSR item code : 15.28.1; change : lead - 100m). |
| 2 | Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 100 metres lead of : Asbestos Sheet (DSR item code : 15.28.2; change : lead - 100m). |
| 3 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work (DSR item code: 13.52.1) . |
| 4 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (DSR item code: 12.5). |
| 5 | Providing & fixing Poly carbonate corrugated sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required. (DSR item code: 50.12.2.1) |
| 6 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Ridges plain (500-600 mm) (DSR item code: 12.51.1) |
| 7 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete: Gutter (600 mm over all girth) (DSR item code: 12.51.6) |
| 8 | Installation charges for postioting of Turbo ventilators in the roofing sheet, supplied by MRCMPU with all necessary fittings and fixtures (OD) |
| 9 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR item code: 10.2) |
| 10 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. (DSR item code: 15.18) |
| 11 | Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete (DSR item code: 50.10.2) |
| 12 | Structural steel work with departmental structural steel sections (supplied by MRCMPU) with riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer as per technical specifications, complete as per the direction of Engineer in charge. (OD) |
| 13 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter (DSR item code: 12.41.2) |
| 14 | Providing and fixing tarpaulin sheet beneth the roof truss/for vertical extension as per requirement including fastening/tying with building/scaffolding pipes or with any other fixtures etc. complete as per direction of Engineer-in-Charge. (One time payment shall be made for providing tarpaulin sheet from start of work till completion of work including shifting if any. The tarpaulin sheet shall be the property of the contractor on completion of the work) (OD) |
| 15 | Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10km for all lifts, complete as per directions of Engineer-in-charge. Payment shall be made on truck measurement (OD) Truck measurement (OD) Please Enable Macros to View BoQ information |