| 1 | INTERNAL ELECTRIFICATION:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSHPVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 2 | Wiring for twin control light point with 1.5 sq.mm FRLSHPVC insulated copper conductor single core cable in surface / recessed steel conduit,2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 3 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bellpoint ( without independent switch etc.) with 2.5 sq. mm FRLSH PVC insulated copperconductor single core cable in surface/ recessed PVC conduit,and earthing thepoint with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable etcas required.Group C |
| 4 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessed steelconduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 6 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 7 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm |
| 8 | Wiring for light/ power plug with 2X4 sq. mm FRLSH PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 9 | Wiring for light/ power plug with 4X4 sq. mm FRLSH PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 11 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 12 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 13 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 14 | Supplying & fixing of the following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plates etc as required.5/6 Amps One way modular switch |
| 15 | Supplying & fixing of the following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plates etc as required.5/6 A socket |
| 16 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A SWITCH |
| 17 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet |
| 18 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 19 | Supplying and fixing following way, horizontal type three pole and neutral , sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing and suitable cable end box etc. as required. (But without MCB/RCCB/Isolator) 6 way (8+18) Double door |
| 20 | Supplying and fixing following way, horizontal type three pole and neutral , sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing and suitable cable end box etc. as required. (But without MCB/RCCB/Isolator) 12 way (8+36) Double door |
| 21 | Supplying and fixingfollowing ratingTriple Pole and Neutral,415 volts, C curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 AMPS |
| 22 | Supplying and fixingfollowing ratingTriple Pole and Neutral,415 volts, C curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 AMPS |
| 23 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 AMPS |
| 24 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 100 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 AMPS |
| 25 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 26 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 27 | Supply of1200 mm sweep BLDC Ceiling fan, 5 star ratedwith double ball bearing , including motor,shckle kit, pair of canopies,down rod,afety wires and other standard accessories ,remote without regulator as required. |
| 28 | Supply of 300 mm diasingle phase 900 RPM Heavy Duty Industrial Exhaust fan including all accessoriesetc as required. |
| 29 | Supply of 40 W surface mounted extruded aluminiumLED batten (4 feet) with opal diffuser along with all acessories like heat sink, constant current output driver, reflector, cover etc. completesuitable for operating at 230 V,50 Hz, single phase AC supply as per specifications. |
| 30 | Supply of 20 W surface mounted extruded aluminiumLED batten (4 feet) with opal diffuser along with all acessories like heat sink, constant current output driver, reflector, cover etc. completesuitable for operating at 230 V,50 Hz, single phase AC supply as per specifications. |
| 31 | Supply of Integral 45 Watts LED Street Light Luminairewith pressure die cast aluminium housing with IP 66 protection along with all acessories like heat sink, constant current output driver, reflector,glass cover etc. completesuitable for operating at 230 V,50 Hz, single phase AC supply as per specifications. |
| 32 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLSH PVC insulated, copper conductor, single core cable etc. as required. |
| 33 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep |
| 34 | Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 35 | ITC of Street LightLuminaire on wall with suitable Medium class GIpipe bent to shapeincluding wiring the pipe,making connections etc.complete as required. |
| 36 | Supplying, Installation, Testing and commissioningof Astronomical time switchof following configuration to be mounted in feeder pillars / Lighting DBs forautomatic switching On & OFF of street lights at sun Each & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.nominal switching current of 16 A, with 1 NO contact,power reserve for minimum 3 years and One number 3 pole contactor with 12 amps rating (AC3)suitable for 230 V, 50 HZ AC Supply in suitable metal enclosure including providingconnections testing and commissioning etc. as required. |
| 37 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet RJ 11 |
| 38 | Supply and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 1 Pair |
| 39 | EARTHINGEarthing with copper Earth plate 600mm x 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and saltas required. |
| 40 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refilling etc. as required. |
| 41 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 42 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or anyother metallic object) by riveting / nut bolting/ sweating and soldering etc as required. |
| 43 | CABLE LAYING:Supply of aluminium conductor XLPE insulated, PVC inner sheathed, armoured power cable of 1.1 KV grade conforming to IS-7098 Part 1(1988) amended up to date.3.5 X 50 sq mm |
| 44 | Supply of aluminium conductor XLPE insulated, PVC inner sheathed, armoured power cable of 1.1 KV grade conforming to IS-7098 Part 1(1988) amended up to date.3.5 X 25 sq mm |
| 45 | Supplying and laying of following sizeHDPE pipe of PE 80 grade PN 8 pressure rating conforming to IS 4984 -2016 along with all accessories complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63mm dia (OD) HDPE pipe |
| 46 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.Above 35 sq. mm and up to 95 sq.mm |
| 47 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.Upto 35 Sqmm |
| 48 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as requiredAbove 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 49 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as requiredUpto 35 sq. mm (clamped with 1mm thick saddle) |
| 50 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 35 sq. mm and upto 95 sq. mm |
| 51 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 Sqmm |
| 52 | Supplying and installing following size of perforated painted with powder coating hot dipped galvanised iron cable tray with perforation not more than 17.5% in convenient sections ,joined with connectors ,suspended from ceiling with G.I suspenders including GI bolts and nuts etc as required.300 mm width x 50 mm depth x 1.6 mm thickness |
| 53 | Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 54 | Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 55 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5x50 sq mm(35 mm) |
| 56 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm (28mm) |
| 57 | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm and disposal of surplus excavated soil as directed, within a lead of 50 metres. |
| 58 | Supplying and fixing 4 pole, Load Break Switch in Sheet Steel Enclosure of following rating conforms to IEC 947-3 AC-23A, Front operated suitable for 415V, 50Hz AC supply as required.100 Amps |
| 59 | Supplying and fixing 4 pole, Load Break Switch in Sheet Steel Enclosure of following rating conforms to IEC 947-3 AC-23A, Front operated suitable for 415V, 50Hz AC supply as required.63 Amps |
| 60 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.100 A,36KA,FPMCCB |
| 61 | Providing, Laying & Fixing following dia GI pipe (Medium class) in ground complete with GI fittings excluding trenching as required.100 mm dia |
| 62 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead asper direction of Engineer - in- charge. |
| 63 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 2 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 64 | Lightning Arrestor:Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at topwith 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 65 | Jointing copper/ G.I. tape (with another copper/ G.I. tape, base of the finial or any other metallic object) by riveting/ nut bolting/ sweating and soldering etc as required. |
| 66 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
| 67 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
| 68 | Providing and laying GI Tape 32 mm x 6 mm from earth electrode directly in ground as required. |
| 69 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 70 | SITC OF ADDRESSABLE FIRE ALARM SYSTEMSupplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.2 x 1.5 sq. mm |
| 71 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess includingpainting in case of surface conduit, or cutting the walland making good the same in case of recessed conduit as required.32mm |
| 72 | Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications ,complete as required. (Cost of plug in common base shall deemed to be included in cost of detectors) |
| 73 | Supply, installation, testing and commissioning of UL/EN listed (LatestVersion) intelligent Addressabletype Heat Detector(Fixed cum-rate ofrise type) with in built fault isolator / isolator base with max. triggering temperature programable from 58 degree C to 69 degree Ccomplete with all fixing accessorieslike base,base box,self adhesive sticker indicating loop number and address etc. to be installed below/ above false ceiling,roof and concealed space,etc. interconnecting to loop cable,etc.as per specificationcomplete as required. |
| 74 | Supply, installation, testing and commissioning of UL/ENlisted (latest version) Intelligent addressableControl Module/Relay Module (output module) with inbuilt fault isolator/ isolator modulecomplete with termination etc.complete as requiredand as per enclosed specifications. |
| 75 | Supply, installation, testing and commissioning of UL/EN listed (LatestVersion) Response Indicators for getting fire indications of detectors including mounting boxes installed above false ceiling area interconnecting toloop cable etc. as per specificationcomplete as required. |
| 76 | Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable Manual call station (Resetable pull / push type) suitable for semi flush mounting, IP 54with inbuilt fault isolator / isolator module with double gang outlet box, equipment for key operated test-reset lock, electronic or rotary switches for address setting. Manual pull station shall be connected with two wire to SLC loop of Fire Control Panel. Cover shall be made out of LEXAN (or polycarbonate equivalent) with clear operating instruction and the word Fire appearing on the front complete with connections etc. as required and as per enclosed specifications. |
| 77 | Supply, installation, testing and commissioning of UL / EN listed (latest version) loop powered addressable Hooter-cum- strobe with inbuilt fault isolator / isolator module with adjustable sound level in the range of min. 90 db to Max. 120 db at 1M distance complete with termination etc. as required and as per enclosed specification. |
| 78 | SITC OF AIRCONDITIONERS & WATER DISPENSERSSupply installation testing and commissioning of Invertrer type, 5 star rated, copper condensor & Evaporator,2 TR hi-wall mounted split type air conditioning unit consisting of non-ductable single phase wall mounted room unit (evaporator) with cordless remote control and one number of out door condensing unit comprising sealed compressor suitable for operation on singlephase 230 V 50Hz AC supply including fixing the outdoor unit on a raised angle iron platform/wall bracket, fixing of room unit (evaporator), providing and making all inter connection (control&power cablewith flexible copper cable of suitable size as per manufacturer\"s recommendation) between evaporator and condenser unit (if required), providing and making all inter connection between evaporator and condenser unit up to a length of 3.0 (three) meter comprising of Liquid Line & Suction Line including wrapping with closed cell elastomeric nitrile rubber insulation tubes/PE foam including wrapping in white vinyl tape,25mm dia rigid PVC drain pipe up to 03Mtr embedded in suitable dia closed cell elastomeric nitrile rubber insulation/PE foam & wrapping with white vinyl tape,first charging of refrigerant,making hole/openingof suitable size on wall for refrigerant/drain pipe/cable passage , making good the opening after installationetc. complete including all accessories as required.(As per List of approved makes attached herewith) |
| 79 | SITC of extra length of copper pipe (For use alongwithitem No. 01 for quantity in excess of3 metres) (suction & discharge together)between condensor and evaporator unit ,enclosed in with nitrile ruber insulation/PE foam including wrapping in white vinyl tape etc as required. |
| 80 | SITC of extra length of drain pipe(For use alongwithitem No. 01 for quantity in excess of3 metres)from evaporator to a suitable location as per direction of Engineer In Charge,enclosed in nitrile rubber insulation/PE foam including wrapping in white vinyl tape etcas required. |
| 81 | SITC of stabilizer suitable to use with 2 Ton Hi-Wall split ac (As mentioned in Sl no 1) operates in 230V,50Hz, Single phase AC power supply having feature of High and low voltage protection, initial time delay complete etc including all accessories as required. |
| 82 | Supply of HOT/COLD/NORMAL Water dispenser with UV+RO filter, Cold water storage tank of 40 Ltrs, total storage 70-80 Ltrs, Cooling capacity 40 LPH, R.O capacity of 50 LPH, three taps for HOT, COLD, and NORMAL water with Stainless steel body, eco friendly refrigerant, Operating on 230 V, 50 HZ, AC supply as required |
| 83 | SITC of Vertical type, wall mounted, 5 star rated, Electric Geyser , Min. 10 liter storage capacity, Min. 1 KW heating element, suitable for operation on 230 Volt, single phase AC supply, with visual indication for ON-OFF operation , Auto off Function, Stainless steel storage tank with insulation coating, Vitreous enamelled inner tank confirming to IS:13273, etc. complete as required. |