| 1 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sq. mm. |
| 3 | Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA ofUPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)\"s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc-(a) 2KVA |
| 4 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required-25 mm |
| 5 | SITC of 4MP fixed lens Bullet IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOS or better**Minimum Illumination: 0.08 lux color, 0 lux with IR or better**Shutter Speed:1/3 – 1/100,000 sFrame Rate: 1-20 fps or better**S/N ratio: >45 dBLens: 2.8mm fixedVideo Compression: H.265 or better**Resolution: (2650x1440) or better**Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 30mOperating Temperature: -30 to 50 deg CentWeatherproof Standard: IP66 or better**Safety standard: UL |
| 6 | SITC of 4MP varifocal lens Dome IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOSMinimum Illumination: 0.05 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate: 20 fps or better **Lens: 3.6 to 10mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (2650x1440) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 30mOperating Temperature: -20 to 50 deg CentWeatherproof Standard:IP66 or better **Safety standard: UL |
| 7 | SITC of full HD LED Monitor,42 INCHES complying with the following specifications: Resolution : Full HD : 1920 x 1080 or better Backlight : LED Brightness : 300 NITS min. Contrast : 1200 : 1 or better Power supply : 230v + / - 10%, 50 Hz at sitewith connections andalong with all accessories etc.complete as required. |
| 8 | S/I/T/C of 16channel NVR with the following specifications: Camera resolution:upto8MP Interface: 1 HDMI, 1VGA minimum Compression :H.265or better Network Hard disk interface: 1 SATA port suitable for 6TB each Throughput :80Mbps or better** USB Port: 2 USB port (USB2.0)minimum Protocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS Operating temp: -10 to 55 deg Cent Safety standard: UL |
| 9 | SITC of 8 port Giga PoE switch, 16(PoE 10/100) + 2(10/100/1000)+ 1G SFP slot long distance switch |
| 10 | SITC of 10 TB surveillance HDD |
| 11 | SITC of following rack capacity with glass front door, steel rear door, power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U |
| 12 | SITC of IP65 box(without PoE switches)of dimention 310mmX160mmX140 mm onpole or wall with suitable arrangement for support/installation of 8 port Giga PoE switch and 1 nos. 15/16 amp modular switch socket set |