| 1 | PART-A CIVIL WORKCEMENT CONCRETE (CAST IN SITU) |
| 2 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness)includingattachedpilasters,columns,piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: |
| 3 | 1:2:4 (1Cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | MASONRY WORK |
| 5 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 6 | Cement mortar 1:6(1 cement :6 coarse sand) |
| 7 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 8 | Cement mortar 1:6(1 cement : 6 coarse sand) |
| 9 | CLADDING WORK |
| 10 | Providingandfixing 18mmthickgangsawcut,mirrorpolished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters,window sills,facias andsimilar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 11 | Granite stone slab of colour black, Cherry/Ruby red |
| 12 | Area of slab over 0.50 sqm |
| 13 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 14 | Granite work |
| 15 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width up to 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 16 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 17 | WOOD AND P. V. C. WORK |
| 18 | Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. |
| 19 | 50 mm |
| 20 | Providingandfixingaluminiumextrudedsectionbodytubulartype universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight up to 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 21 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 22 | 150x10 mm |
| 23 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 24 | Twin rubber stopper |
| 25 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc. complete. |
| 26 | Providing and fixing magnetic catcher of approved quality in cupboard/ ward robe shutters, including fixing with necessary screws etc. complete. |
| 27 | Double strip (horizontal type) |
| 28 | Providingand fixingbright /matt finishedStainless Steelhandles of approved quality & make with necessary screws etc. all complete. |
| 29 | 100mm |
| 30 | Providing and fixing stainless steel self closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. |
| 31 | FLOORING |
| 32 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 33 | Size of Tile 600x600 mm |
| 34 | ProvidingandlayingVitrifiedtilesindifferent sizes (thickness tobe specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 35 | Size of Tile 600x600 mm |
| 36 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 37 | Size of Tile 600x600 mm |
| 38 | Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles (rate will be considered negative). |
| 39 | ROOFING |
| 40 | Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 nnm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers including chasing into the walls and finishing etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required. |
| 41 | Providingandfixingridgesandhipsinfibrecementreinforcedby organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete. |
| 42 | Corrugated serrated adjustable ridges |
| 43 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main \"T\" runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross \"T\" of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main\"T\" at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main \"T\" runners to be suspended from ceiling using al. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main \"T\". Bottom exposed with 24 mm of all T-sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection >85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity <0.043 w/mK. |
| 44 | Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm c/c, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I channels 45 x15 x 0.90 mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450 mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64 mm dia x 230 mm long G.I wire at every junction, including fixing perimeter channels 0.50 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25 mm at 230 mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150 mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture\"s specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with: |
| 45 | 8 mm thick Calcium Silicate Board made with Calcareous & Siliceousmaterialsreinforcedwithcellulose fibre manufactured through autoclaving process. |
| 46 | FINISHING |
| 47 | 12 mm cement plaster of mix: |
| 48 | 1:6(1 cement: 6 fine sand) |
| 49 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement: 6 fine sand). |
| 50 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 51 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 52 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 53 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand andmanufacturerincluding applying additional coats wherever required to achieve even shade and colour |
| 54 | Old work (one or more coats) |
| 55 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approvedbrandandmanufacture,includingapplyingadditionalcoats wherever required to achieve even shade and colour. |
| 56 | One coat |
| 57 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 58 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 59 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 60 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 61 | One or more coats on old work |
| 62 | REPAIRS TO BUILDING |
| 63 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 64 | With cement mortar 1:4 (1 cement : 4 fine sand) |
| 65 | Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface including disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. |
| 66 | For door/ window/ clerestory window |
| 67 | Dismantling and Demolishing |
| 68 | Demolishingbrickworkmanually/bymechanicalmeansincluding stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 69 | In cement mortar |
| 70 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 71 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer- in-charge. |
| 72 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 73 | ALUMINIUM WORK |
| 74 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fastenersto be paid for separately) : |
| 75 | For fixed portion |
| 76 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 77 | Forshuttersofdoors,windows&ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 78 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 79 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 80 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 81 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 82 | Up to 5 mm depth and 5 mm width |
| 83 | Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 84 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge |
| 85 | Powder coated minimum thickness 50 micron aluminium |
| 86 | NEW TECHNOLOGIES AND MATERIALS |
| 87 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type orof approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 88 | 25 mm average thickness |
| 89 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust freesteel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 90 | Bars up to 12 mm diameter |
| 91 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as perspecifications and direction of Engineer- In-charge complete in all respect. |
| 92 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 93 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used)as per specifications and directions of Engineer-in-charge.Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 94 | 25 mm average thickness in 2 layers. |
| 95 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite)soliddoor/window/Clerestorywindows&otherFrames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with mitre joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A categorywithpropertyofbeingtermite/borerproof,water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and lengthcomplete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 96 | Frame size 45 x 70 mm |
| 97 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid board one side white colour and other side of board laminated with PVCfoil of minimum 14 micron thickness of approved design pasted with hot melt adhesive for cup boards, work stations and bathroom/ kitchen cabinet etc. of required sizes comprisingof virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel piano hinges/soft close clip on concealed hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.(Note: stainless steel piano hinges/soft close clip on concealed hinges and necessary S.S screws shall be paid separately) |
| 98 | 18 mm thick |
| 99 | Credit Items (as per Local MR) |
| 100 | Credit value item for selling of old aluminum section (door, partition) and aluminum frame work removed from false ceiling, etc. on as is where is basis (rate of item will be considered negative). |
| 101 | SOR Derived Items |
| 102 | Providing and fixing Kota stone slabs 20 to 25 mm thick gang saw cut and prepolished, machine cut for bottom stone of sandwich type kitchen platforms, vanitycounters and similar locations of required size fixed by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 103 | Providing and fixing machine cut, mirror/ eggshell polished, Granite stone work for wall cladding, door frame/ Window Jambs including dado, skirting, risers of steps etc., in required design and pattern wherever required, atfinished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with cement slurry @ 3.3 kg/sqm including pointing with epoxy grout with pigment of matching shade, including rubbing, curing, moulding and polishing of edges to give high gloss finish all complete as per directed by the Engineer-in-Charge. |
| 104 | Granite Stone of approved shade |
| 105 | Dismantling steel work in built-up sections such as angles, tees, flats, and channels including all gusset plates, bolts, nuts, cutting of rivets/welds, etc., including dismembering of components and stacking the serviceable material within 50 metres lead.Thereafter, the dismantled material shall be reused for fabrication of a new designed structure as per site requirement, including cutting, welding, drilling of holes, fixing with bolts/nuts, grinding, aligning, and all necessary fabrication operations. All members shall be thoroughly scraped to remove rust, scales, grease, etc., and one coat of red oxide zinc chromate primer shall be applied to all fabricated surfaces before erection, as directed by the Engineer-in-Charge. |
| 106 | NON SOR items |
| 107 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre with fully washability and ultra matt finish/ soft sheen finish with Teflon protector technology with 8 years of warranty of approvedbrandandmanufacture,includingapplyingadditionalcoats wherever required to achieve even shade and colour. |
| 108 | Two or more coats |
| 109 | PART-B ELECTRICAL WORKWIRING |
| 110 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 111 | Group C |
| 112 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 113 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 114 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 115 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 116 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connectionsbutexcludingmodularplateetc.as required. |
| 117 | 5/6 A switch |
| 118 | 15/16 A switch |
| 119 | 3 pin 5/6 A socket outlet |
| 120 | 6 pin 15/16 A socket outlet |
| 121 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 122 | 12 Module (200mmX150mm) |
| 123 | MCCB, MCB & DB\"S |
| 124 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DBcompletewithconnections,testingand commissioning etc. as required. |
| 125 | Single pole |
| 126 | Triple pole |
| 127 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \"C\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 128 | LED LIGHT |
| 129 | LED Panellight 2x2ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panellight 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirementwith Driver efficiency >85%, Operating voltage AC 140-270 Volt,frequency 50/60hz, Operatingtemprange -5 0Cto 40 0C,internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95,IP20, CRI >80, UGR(UnifiedGlareRating) <19,Flickerfree, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry),of minimum 50000 Burning Hours with , 70% of initial Lumenmaintained till life ends ,CCT 3000°K / 4000°K /5700°K /6500°K (As perANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. ManufacturesWordMark/NameEngraved/ Embossing/ Screen printing on housing. complete inallrespecti/c external connectionswith 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5yearOEMwarranty. System lumen efficacy>135lm/Watt output . LM79 & LM80 Test report andalltestingrequiredfor LED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heatsinkofaluminiumhousingsuchthatLED junction temperature shall not rise above 90°C). |
| 130 | 40 watt |
| 131 | BLDC FAN |
| 132 | Brush Less Direct Current (BLDC) Fan with Remote Supply,Installation,TestingandCommissioningof ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. PowerFactornotlessthan 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019fan i/c externalconnectionswith 1.5sq.mmFRLS/HFFR, PVC insulated copper conductor singlecorecable andearthingetc.asrequired. |
| 133 | 1400mm,service value≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 134 | MV CABLE LAYING |
| 135 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 136 | up to 35 sq. mm (clamped with 1mm thick saddle) |
| 137 | MV CABLE JOINTING & END TERMINATION |
| 138 | Supplyingandmakingendterminationwithbrass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required. |
| 139 | 3½ X 35 sq. mm (32mm) |
| 140 | Non-Schedule/ MR |
| 141 | Supplying & Fixing of 300 mm sweep metal body exhaust fan, HEAVYduty,,230 Volts,50Hz,1400 RPM single phaseA.C.supplyandmountingframe on teak wooden frame(19 mm) ,complete including making the hole in wall and refinished itwith testing, commissioning etc. as reqd. |
| 142 | Supply at site of 1100V/ 11000V Gr. following armoured XLPE cable having sector / circular shaped Aluminum conductor of the following sizes. |
| 143 | 3.5 core x 35 sq.mm Aluminium cable. |
| 144 | Supplying and fixing following ways surface/ recess mounting, vertical type, 415 volts, VTPN distribution board of sheet steel, dust protected, duly powder painted, inclusive of suitable amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s, with provision of 100-250 amps TP 25 KA MCCB as incomer, interconnection between incomer MCCB and bus bars as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (i)8 way (4 + 24), Double dooralong with Providing and fixing 125 Ampere TP MCCB rating and 25kA breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required and suitable Fit for this VTPN DB. |
| 145 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MOB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (i)8 way (4 + 24), Double door along with Providing and fixing 100 Ampere TP MCCB rating and 10kA breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required and suitable Fit for this VTPN DB. |
| 146 | Supplying & Fixing of wall mounted Hand dryer 220-240V, 50Hz, 24000 RPM, 70db(A), touch free Infra-Red Activation, 304 S S JET HAND DRYER MOTOR HEAVY DUTY complete including making the hole in wall and refinished itwith testing, commissioning etc. as reqd. |