| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 2 | Providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 Coarse sand :8 graded stone aggregate 40 mm nominal size). |
| 3 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in cement mortar 1:6 (1-Cement : 6- Sand) |
| 4 | Chequerred precast cement concrete tiles 22 mm thick in footpath and courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 corse sand ) ordinary cement without any pigment |
| 5 | Centering & Shuttering with plywood or steel sheets including strutting propping, bracing both ways and removal of formworks for foundation in footings , straps beams , raft , bases of coloumns etc. |
| 6 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers ( if required ) excluding the cost of centering, shuttering and reinforcement . M20 Grade Nominal Mix / design mix |
| 7 | Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers ( if required ) excluding the cost of centering, shuttering and reinforcement . M20 Grade Nominal Mix / design mix Add extra for providing richer mixes respectively at all floor levels Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix. |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. |
| 9 | Random rubble dry stone kharanja under floor . |
| 10 | Brick work with mechanised autoclaved flyash lime bricks conforming to (IS:12894 :2002) of class designation 100 in super structure above plinth level up to floor five level in cement mortar 1:6.(1- cement : 6- coarse sand) |
| 11 | Half Brick work with mechanised autoclaved flyash lime bricks conforming to (IS:12894 :2002) of class designation 75 in super structure above plinth level up to floor five level in cement mortar 1:6.(1- cement : 6- coarse sand) |
| 12 | Centering & Shuttering with plywood or steel sheets including strutting propping, bracing both ways with steel props and removal of formworks for upto floor five level for suspended floors, roofs, landings staircases balconies, girders, cantivlevers bands,coping bed plates anchor blocks sill, chajjas, lintel , beams, plinth beam etc. |
| 13 | Centering & Shuttering with plywood or steel sheets including strutting propping, bracing both ways with steel props and removal of formworks upto floor five level for columns, pillers, posts and struts etc. |
| 14 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement for walls (any thickness) including attached pilasters, buttresses, plinth and string coarses,fillets, columns, pillars, piers,abutements, posts and struts etc.M-20 grade nominal mix/design mix.Add extra for providing richer mixes respectively at all floor levels M-25 Grade concrete by using cement as per codal provision instead of M-20 grade design mix |
| 15 | Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement for beams, suspended floors, roofs, griders, having slopes up to 15 degree, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases etc.M-20 grade nominal mix/design mix. |
| 16 | Providing and fabricating reinforcement for R.C.C. work including strengthening, cutting, bending, placing in position and binding including cost of binding wire all complete up to floor five level.(original producers\" who manufacture billet directly from iron oras and role the bilets to produce steel conforming to IS:1786) TMT Bars(CONFORMING OF RELEVENT IS CODE) |
| 17 | PLASTER (Internal) Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finish : 12 mm thick. |
| 18 | PLASTER (External) Plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finish : 20 mm thick |
| 19 | Washed stone grit plaster on exterior walls of height upto 10 M. above level in two layers, under layer 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2kg of cement per sqm, top layer 15 mm cement plaster 1:1/2:2 ( 1 cement : 1/2 coarse sand : 2 stone chipping size 10 mm nominal size) in panel with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chipping, complete as per specification and direction of Engineer in charge. (Payment for providing grooves shall be made separately) |
| 20 | Making grooves as per design in plaster 10mm to 20mm wide. |
| 21 | Kota Stone slabs 25 mm thick in risers of step skerting, dado and pillars Laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand ) and jointed with Grey cement Slurry mixed with pigment to match the shade of the Slabs, including rubbing and Polishing complete For area of each slab upto 2001 sqcm. |
| 22 | Kota Stone slabs flooring 25mm thick over 20mm (averege) thick base laid over and jointed with Grey cement Slurry mixed with pigment to match the shade of the Slab including rubbing and Polishing complete with base of cement mortar 1:4 (1 cement : 4 coare sand) For area of each slab from 2001 to 5000 sqcm. |
| 23 | S&F in walls machine cut & polished stone shelves ,tands and in CM1:3 with machine cut edges : Kota Stone minimum 30 mm thick. |
| 24 | Kota Stone slabs 25 mm thick in risers of step skerting, dedo and pillers Laid on 12mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand ) and jointed with Grey cement Slurry mixed with pigment to match the shade of the Slabs, including rubbing and Polishing complete For area of each slab from 2001 to 5000 sqcm. |
| 25 | Providing and fixing Ms Sheet 1mm thick single Leaf doors shutter in angle iron frame 35x35x5mm suitabilly digonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engineer incharge but excluding cost of chowkhats including two coats of anti-corrosive red oxide primer paint. Add 20 % extra for double leaf shutter. |
| 26 | Providing and Fixing T-iron /frames for doors, windows and ventilators of mild steel tee section joints mitred and welded with 15 x 3 mm lugs, 10cm . Long embedded in cement concrete blocks, 15 x 10 x 10 cm of 1:3:6 (1 cement, 3 coursed sand and 6 graded stone aggregate 20 mm nominal size or with wooden plugs and screws or rawl plugs and screw or with fixing clips or with bolt and nuts as require including fixing of necessary butt hinges and screw and applying a priming coat of approved steel primer |
| 27 | Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred welded and grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to frame for paitam fixing float glass 4mm thick panes with glazing clips and metal sash putty and fixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge. Window openable. |
| 28 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 29 | Providing and fixing square bars or other flat welded to window ventilators etc |
| 30 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : (2 or more coat on new work ). |
| 31 | Providing and Applying white cement based putty over plastered surface to prepare the surface even and smooth complete new plaster surface (three or more coats) |
| 32 | Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete |
| 33 | finishing walls with acrylic smooth exterior paint of required shade including all scaffolding new work (two or more coat applyied @1.67 lt. per 10 sqm over an including base coat of water proofing cement paint applyied @ 2.20 k.g. per 10 sqm. |
| 34 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 35 | P/A Three coat of acrylic water proof membrane heving sunlight and UV resisttant properties over waterproofing slurry coat initial coat of 50-75 micron thickness with diluting 1 part of chemical with 2 part of clean water , over which applying 2 coats at 2 hrs intervals each with diluting 1 part of chemical with 20 % of clean water for total thickness of 400 to 450 microns ( covering area 0.90 sqm /kg of chemical including preparation of surface by cleaning brushing and dust removing scaffolding if necessary etc. with contractor\"s labour, tools, machinery etc. complete as directed by engineer incharge |
| 36 | Grading For roof water proofing tratment with water proofing compound cement concreate 1:2:4 (1cement :2coarse sand :4 graded stone aggregate 20mm nominal size) |
| 37 | Providing Gola75 mm x 75 mm in cement concrete (1:2:4)(1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge )including finishing with cement mortar 1:3( 1 cment : 3 fine sand ) as per standard design. |
| 38 | P& F rigid PVC Pipe (IS 4985 Mark) Class 2nd /(4 kg /sqcm) approved quality / Make including joining the pipe with solvant cement rubber ring and lubricant 110 mm dia. |
| 39 | Providing & Fixing Steel gate grating and grills made of angles, tees, square bars, flats or black pipe with holdfast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide raliling (steps & ramps) |
| 40 | Supplying and fixing machine cut fine dressed Red/Pink sand stone dasa or coping, with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade. 50 mm thick |
| 41 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 42 | Lattering with black japan paint of approved brand and manufacture |
| 43 | ELECTRICAL WORK |
| 44 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.25mm dia. |
| 45 | P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 46 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Short point(up to 3 mtr) |
| 47 | .-----Medium point (up to 6 mtr.) |
| 48 | .------ Long point (up to 10 mtr..) |
| 49 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.On board |
| 50 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.3 x 2.5 sq.mm |
| 51 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.6 A to 32 A rating |
| 52 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 50/63 A rating |
| 53 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.Metal door (single phase) IK-09 and IP-43 with Metal end box.4Way(4+2) |
| 54 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 55 | Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) |
| 56 | Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printed made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including all as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.5 step fan regulator 2 Module 360 dgree rotating |
| 57 | P & F 1.2 mm thick G. I. / M .S. Sheet boxes duly finished with two coats of red oxide and with earthing terminal of following sizes (nominal size) in recessed/surface as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.1.2 mm thick M. S. Sheet boxes .175mm x 100mm x 60mm |
| 58 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .LED Street Light fixture with Minimum lumen output 7500 lm |
| 59 | P & F P.V.C. sheet 2.0 mm thick of following size Including screws, cup washer as required.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.75 mm dia |
| 60 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) including testing etc. as required of following size. OEM must have it\"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.4.0 Sq. mm,2 core |
| 61 | Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR . Please Enable Macros to View BoQ information |