| 1 | Taking down chowkats or frames exc 1.5 sqm but n.exc 4 Sqm each with shutters (without taking off shutters from the frames) complete all as secified and directed. |
| 2 | S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 100 x 65 mm comprising of virgin PVC polymer of natural fibewith property of being termite/borer proof water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as secified and directed. |
| 3 | S&F for Factory Made Solid WPC Door Shutter, 28 to 30mm thick (stiles), supplying & fixing in frame at site as per specification & drawing complete all as secified and directed. |
| 4 | S&F for powder coated aluminium sliding windows two track with three sliding shutters with extrusions aluminium of following sections including jointing cleats, glazing clips, rubbr packaging, snap beading and other necessary builders hardware as required complete all as secified and directed.(A) FRAME:-(i) Top and side member fortwo track frame of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.784 kg/ mtr), Model No. 20829 of Jindal or equivalent as specified in PS. |
| 5 | (ii) Bottom rail of frame for sliding of size 61.85 mm x 31.75 mm x 1.5 mm (weight 0.909 kg/ mtr), Model No. 20830 of Jindal or equivalent as specified in PS.(B) SHUTTER:-(i) Top and bottom rail of sliding shutter of size 40 mm x 18 mm x 1.5 mm (weight 0.547 Kg/ mtr), Model No. 20736 of Jindal or equivalent as specified in PS.(ii) Side of sliding shutter with handle and self locking arrangement, section of size 40 mm x 18 mm x 1.5 mm (weight 0.547kg/ mtr), Model No. 20738 of Jindal or equivalentas specified in PS.(C) Sliding shutter to be provided with 5.5 mm thick sheet glass complete all as specified and directed.(D) Supply & Fix for 6.5 mm thick aluminium diamond grill with mill finished fixing on wall/wooden chowkhat/ aluminium frame with suitable size of aluminium \"U\" channel and steel chromium plated, screw with rawel plug complete all as specified and directed with following details:- (i) Aperture size of aluminium grill 67 mm x 84 mm. (ii)Cord dimension 7 mm x 5.8 mm. (iii) Plate thickness 2 mm. (E)Supply & Fix for Galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm fixed with galvanised wire staples/ clip/ aluminium flat complete all as specified and directed. |
| 6 | S&F forSheet glass, selected quality5.0 mm thick, glazing with rubber beading not exc. 0.5 sqm in each pane complete all as secified and directed. |
| 7 | Excavating in post holes (or similar holes) each n.exc 0.5 Cum, getting out, returning, filling in and ramming earthor broken rubble mixed withearth around, in layers not exceeding 25 cm soft / loose soil complete all as secified and directed. |
| 8 | M&L for PCC1:3:6 type C2 using 40mm graded stone aggregate) infoundation filling mass concrete complete all as secified and directed. |
| 9 | S&F for prelaminated particle board 12 mm, exterior grade prelaminated one side with decorative choice lamination on other side balancing white lamination, fixed with screws to timber frame work complete all as secified and directed. |
| 10 | S&F for Veneered decorative plywood 12mm thick, grade 1 (with BWR resin) with decorative face veneers on one faces, fixed with screws to timber frame work lamination, fixed with screws to timber frame work complete all as secified and directed. |
| 11 | S&F for Beads, 2nd class hard wood straight (any size) for glazed or gauzed joinery, renewed, including mitres complete all as secified and directed. |
| 12 | S&F for 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel brass polished, bright finished complete all as secified and directed. |
| 13 | S&F for Hasp and staple, 75mm mild steel, safety type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as secified and directed. |
| 14 | S&F for 100 mm butt hinges, medium weight, cold rolled mild steel, and fixed complete all as secified and directed. |
| 15 | S&F for 150 mm butt hinges, medium weight, cold rolled mild steel, and fixed complete all as secified and directed. |
| 16 | M&L for 2 coats of synthetic enamel painting to new wooden surfaces over a coat of pink primer over 10cm width or girth including preparation of new surfaces complete all as secified and directed. |
| 17 | S&F for Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick having tensile strength of 550 Mpa as in roof covering/ridge/ cladding to wall, fixed with self tapping screw with in built washers and neoprene & EDPM washers, in roofs, walls etc complete allas specified and directed. |
| 18 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick having tensile strength of 550 Mpa as in roof covering /cladding to wall, as in valley gutter, ridge etc fixed with self tapping screws as specified etc complete all as secified and directed. |
| 19 | M&L for Painting tonew steel Surfaces of any description, over 10cm in width or grith with two coat of synthetic enamel paint over a coat of red oxide, not otherwise described complete all as secified and directed. |
| 20 | M&L for 15mm thick rendering in cement mortar (1:4)surfaces with fair and even without using extra cement complete all as secified and directed. |
| 21 | M/L rendering 10mm thick in cement mortar (1:6) on brick or concrete surface finished even and smooth without using extra cement complete all as secified and directed. |
| 22 | M&L for Preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat of putty and alkali resistant primer complete all as secified and directed. |
| 23 | Demolition of cement concrete (unreinforced) in ground floor and pavings n.exc 15 cm thickness(below or above ground level) complete all as secified and directed. |
| 24 | M&L for 75 mm thick, PCC (1:3:6) type B-2 using 40 mm graded stone aggregates as in sub base complete all as secified and directed. |
| 25 | M&L for heavy duty enduratileswith grey cement and pigments 30 cm x 30 cm x 8 mm thick, set jointed and pointed in neat cement slurry to be laid over screed bed complete all as secified and directed. |
| 26 | M&L for PCC 1:3:6, type C-1, 75mm thick as in plinth protection, surface finished fair and smooth without using extra cement complete all as secified and directed. |
| 27 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/ blankets, any thickness, including cover fillets removing rubbish obtained from dismantling from work site out side MD land at any distance complete all as secified and directed. |
| 28 | S&F for PVC Soffit systemfor False Ceiling / Wall Panelling purpose, to be screw fixed on a GI (GI-0.4mm) Channels or equivalent and standard hardware framework with interlocking between panels, Panel Size: 2700x300mm/; Panel colours : 4 shades of Wooden (Walnut / Winchestar oak / Oak /Golden Oak ) or 3 Shades of Uni Colour (White / Brown / Graphite); to be applied with finishing trims in same colour combination of soffit panel (J - Trim & T – Trim for False Ceilings. Panels to be in strict compliance with PN-EN ISO 527-1:2012 / PN-EN ISO 527-2:2012. Soffit Panels, 340 mm (effective usage area of 300mm) wide, 12 mm deep, 1.2 mm thick PVC sheets, plain / perforated / hidden perforated without non-woven acoustic textile. Panels feature a 11 mm wide flange for interlocking between the panels. Optionally the flange with 11 x 3 mm ventilation holes can be used to achieve a ventilated ceiling. Panels to be manufactured from Solid PVC surfacePanels have a size of 2700x340mm; Effective size for Coverage: 2700x300mm. Panels to be installed using J – Trim along the periphery and to be coupled in longitudinal direction using T – Trim of the same colour combination of the panel for False Ceiling applications complete all as secified and directed. |
| 29 | S&F for powder coated GI Snap grid system of size 605 X 605 mm for ceiling fixed to walls with rawl plugs and screws and hang to roof members with 2 mm dia GI wire comprising of the following sections complete all as specified and directed:- (i) Maint Tee 28mmx24mmx0.3mm thick, (ii) Cross Tee 28mmx24mmx0.3mm thick and (iii) Wall angle 24mmx24mmx0.3mm thick complete all as specified and directed. |
| 30 | S&F for 4 mm thick designer ceiling (E-board classic tiles) for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or GI sanp grid or with staples on snap grid as in ceilingwith and including dusting of surface and applying two coats of oil bond distemper over a coat of primer complete all as secified and directed. |
| 31 | S&F for PVC wall panelling 2to 3 mm thick any colourto be screw or fixed on a plywoodsmooth surface complete all as secified and directed. |
| 32 | S&F for 20 mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors complete all as secified and directed. |
| 33 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as secified and directed. |
| 34 | M&L for joint free non-skid coloured ceramic tiles 7 to 8 mm thick, area of each tile exc 0.18 Sqm but n.exc 0.38 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as secified and directed. |
| 35 | M&L for joint freeVirified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as secified and directed. |
| 36 | S&F for glazed ceramic coloured /printed tiles 300x450x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match on verticle surface of wall complete all as secified and directed. |
| 37 | M&L for screed bed or bedding laying of cement mortar (1:4) 15 mm thick for as in floor finishes complete all as secified and directed. |
| 38 | M&L for backing coat of cement mortar 1:410 mm thick for as in vertical surfaces such as skirting , dados etc complete all as secified and directed. |
| 39 | M&L for 20mm thick Granite (of any type) tiles machine cut, in vertical surface/ slab laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 10mm thick rendering of cement mortar 1:4 for laying of granite complete all as specified and as directed. |
| 40 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as secified and directed. |
| 41 | S&F for rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 ltr capacity hoisted and fixed in position with air pipe all as specified including dismantling old one complete all as secified and directed. |
| 42 | S&F for sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe,bowl size 410mm x 330mm x 160mm complete all as secified and directed. |
| 43 | S&F for Stop valves, fancy type,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair complete all as secified and directed. |
| 44 | S&F in repair mozio cabinet lion vanity withWall Mirrors , wash hand basin sizeincluding 32mm dia brass chromium plated waste fitting a pair if cast iron bracket duly painted /erecting stand including cutting and pinning in ends making good disturbed surfaces in cement mortar 1:3 including taking down unserviceable wash hand basin and connected items of any description complete all as secified and directed. |
| 45 | S&F in repair 15mm bore dia pillar taps, fancy type chromium plated with capstan heads chromium plated screwed down high pressure, with or without lettered \"hot or cold\" with long screwed shank and fly nuts screw for iron pipe complete all as secified and directed. |
| 46 | M&L for 75mm PVC (SWR) floor trap, with grating including jointing with solvent cement complete all as secified and directed. |
| 47 | S&F for PVC (SWR) pipes single socketed in any length with rubberring joints fixed to walls with clamps 110mm bore complete all as secified and directed. |
| 48 | S&F for PVC (SWR) pipes single socketed in any length with rubberring joints fixed to walls with clamps 75mm bore complete all as secified and directed. |
| 49 | S&F for PVC (SWR) bends any radius 110mm bore complete all as secified and directed. |
| 50 | S&F for PVC (SWR) bends any radius 75mm bore complete all as secified and directed. |
| 51 | S&F for PVC connection 15mm size with PTMT nuts of length 450mm complete all as secified and directed. |
| 52 | S&F for grating doom 100/125 mm dia of PTMT (Minimum weight 5gms) complete all as secified and directed. |
| 53 | S&F for Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wiren.exc 4kg per Sqm not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as secified and directed. |
| 54 | M&L for Fe 410 -W (Gde-250)quality B Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etccomplete all as secified and directed. |
| 55 | M&L for Fe 410 -W (Gde-250)quality BSteel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240complete all as secified and directed. |
| 56 | Demolition of Brickwork or stone/ boulder masonary ,built in cement mortar or cement lime mortar complete all as secified and directed. |
| 57 | M&L for Brick work with sub-class `B\" in half brick , straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as secified and directed. |
| 58 | M&L for brick work built in cement mortar (1:6) straight or curved on plan exceeding 6 metre mean radius using sub class ‘B’ bricks (Old size bricks) complete all as specified and directed. |
| 59 | S&F for 20 mm bore ballbrassvalve,high pressure with polythene float and fly nut complete,screwed for iron pipe or brass ferrule,complete all as secified and directed. |
| 60 | Surface excavation in soft/loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as secified and directed. |
| 61 | Removal of excavated soil exec 50 mt andn exc 250m and deposition where directed at a level n.exc 1.5m above the starting point complete all as secified and directed. |
| 62 | M&L for Hard core of gauge n.exc 63mm broken stone or boulder deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as secified and directed. |
| 63 | M&L for 100 mm thick Plain Cement Concrete Type D2 1:4:8 ( using 40 mm graded stone aggregte) in Pavings complete all as secified and directed. |
| 64 | M&L for machine pressed precast concrete interlocking paver block any shape and size size conforming to IS-15658-2006 of60mm thickness M-35m Gradewith grey cement and pigment complete all as secified and directed. |
| 65 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as secified and directed. |
| 66 | M&L for Providing, cement concrete Type B1 1:2:4 (20mm graded stone aggregate)in roof kerbs or mud stops, rounded or chamfered on edges complete all as secified and directed. |
| 67 | M&L for Preparation of old decorated plastered surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying two coat of distemper oil emulsion over a coat of wall care putty complete all as secified and directed. |
| 68 | S&F for Room Divider Curtain, Privacy Cubicle Curtain with Mesh Top, 1 Panel, 9ft Wide x 8ft Tall Grommet Curtain, Freestanding Hanging Room Divider Curtain Rodand all fittings required for hanging curtain Studio Rental Hospital (Beige) including Polyester Curtainof 3 m height complete all as secified and directed. |
| 69 | Demolition of cement concrete above ground floor and pavings exc 15 cm thickness (below or above ground level) unreinforced complete all as secified and directed. |
| 70 | S&F for Window Films Opaque Sparkle Frosted Home Security Self Adhesive for Bathroom Door Window Heat Control Anti UV - 16 x 48 Inches complete all as secified and directed. |
| 71 | S&F in repair Door closer hydraulically regulated ,aluminium extudrddesignation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as secified and directed. |
| 72 | S&F for Godrej Mortise Lock I Mortise Door Handle Lock for Main & Internal Door in Residential & Commercial Spaces I NEH 19-1 CK I Antique Brass Finish 20cm / 8 Inches Handle, with Lock Body & 3 Keys complete all as secified and directed. |
| 73 | S&F forItalian Collection One-piece Fabio Floor Mount Western Commode for Bathroom Made of Ceramic S-220 TrapSyphonic Flush Rimless Soft Close Star White anyshape complete all as secified and directed. |
| 74 | S&F for Decor Production Self Adhesive PVC Wall Sticker - Multicolor ,Vinyl Wall Posters for Home, Living Room, Hall, Play Room, Bedroom and Office DecorEasy to Apply & Remove of sign complete all as secified and directed. |
| 75 | M&L for RCC Nominal mix Type B0 1:2:4 (12.5mm graded aggregate) Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves complete all as secified and directed. |
| 76 | M&L for Mild steel TMT bars 10 mm dia and over as in reinforcement cut to length bent to shape required including cranking, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia complete all as secified and directed. |
| 77 | S&F in repair CP health faucet with complete assembly all asspecified and directedincluding taking down existing complete all as secified and directed. |
| 78 | S&F in repair CP brass body Angle cock all asspecified and directedincluding taking down existing complete all as secified and directed. |
| 79 | M&L for point wiring with 1.5 sqmm cable PVC insulated, unsheathed type, copper conductor, multistranded cable (FRLS Type), 1100 Volts grade (red colour cable for phase and black colour cable for neutral) including 1.5 sqmm copper conductor, multistranded cable (FRLS type) 1100 volts grade unsheathed PVC insulated ( green colour cable for earth wire) continuity earth wire connected to common earth dolly to be drawn in and including PVC casing caping, medium grade of suitable size including all fittings such as bend, elbow, tee, joint etc with sunk cast pressed steel terminal box made out of MS sheet with 3 mm thick hylum laminated sheet cover / plastic gang box for mounting of switch, complete all as specified and directed for following:- |
| 80 | Light/ Exhaust fan point controlled by one number one way switch |
| 81 | M&L for sub main wiring with two run of 4.0 sqmm PVC insulated unsheathed FLRS copper conductor single core multi strandedand one run of insulated copper earth wire 4.0 Sqmm drawn through PVC medium grade Conduit complete all as secified and directed. Note :- Copperconductor 3 run of 4 sqmm and one run PVC conduit shall be measured as one length. |
| 82 | M&L for concealed sub main wiring with two run of 6.0 sqmm PVC insulated unsheathed FLRS copper conductor single core multi strandedand one run of insulated copper earth wire 6.0 Sqmm drawn through PVC medium grade Conduit complete all as secified and directed.Note :- Copperconductor 3 run of 6 sqmm and one run PVC conduit shall be measured as one length. |
| 83 | S&F for Modular switch 1 way 6A,1 module complete all as secified and directed. |
| 84 | S&F for Modular switch 1 way 16A,1 module complete all as secified and directed. |
| 85 | S&F for Modular Socket 6A/16A - 2/3 pin combined 2 module complete all as secified and directed. |
| 86 | S&F for White cover plate with frame,3 module complete all as secified and directed. |
| 87 | S&F for Modular Metal flush box 3 module complete all as secified and directed. |
| 88 | S&F for ceiling rose surface type bakelite 3 terminals 230 volts AC complete all as secified and directed. |
| 89 | S&F for sheet metal enclosure single pole and neutral with two pin and earth plug complete with one single pole MCB 20 amps, 230 volts complete all as secified and directed. |
| 90 | S&F for sheet metal enclosure MCB DB TPN double door type AC 415 V 4 way with 200 Amps rated bus bar, vertical/horizantal type complete and making good of disturbed surface complete all as secified and directed. |
| 91 | S&F for sheet metal enclosure single door type suitable for mounting MCCB TPN AC 415V ,vertical / horizantal type complete and making good of disturbed surface complete all as secified and directed. |
| 92 | S&F for sheet metal enclosure MCB DB SPN single door type AC 240 V 4 way with 200 Amps rated bus bar, vertical/horizantal type complete and making good of distructed surface complete all as secified and directed. |
| 93 | S&F for MCB TPN 40 to 100 Amps, 230 volts, C curve complete all as secified and directed. |
| 94 | S&F for MCB SPN 32 Amps, 230 volts complete all as secified and directed. |
| 95 | S&F for MCB SP 20 Amps, 230 volts, C curve complete all as secified and directed. |
| 96 | S&F for MCCB, TPN 200 Amps, 36 kA breaking capacity with overload and adjustable thermal & adjustable Magnetic tripping features, 415 volts, AC, 50 Hz complete with suitable spreader complete all as secified and directed.Note: Requirement of nuts and bolts, cable lugs for fixing of MCCB in existing panel deemed to be included in quoted rate |
| 97 | S&F for inverter type batten LED light fitting of capacity 1X 20 W (or nearest next higher wattage) (4feet), 6500K, wall/ surface mounted,square profile housing and polycarbonate channel including lithium lon battery with charging time 8 hours and back up time up to 4 hours decorative type with integrated high efficiency electronic driver and operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up complete all as secified and directed. |
| 98 | S&F for exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers in suitable square/rectangle/circle shape in wall including cutting of wall and making good disturbed surfaces of walls complete all as secified and directed. |
| 99 | Excavation in trenches n.exc 1.50 mtr wide and not exceeding 1.50 mtr deep for taking out/ laying of under ground cable, pole, pipe, stay and getting out in soft soil strata including making good to the disbturbed surfaces such as hardstanding, footpath/ pavments complete all as specified and directed. |
| 100 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm spread any type of soil complete all as secified and directed. |
| 101 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above the starting point complete all as secified and directed. |
| 102 | M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable complete all as secified and directed.Note: Punned thickness of sand shall be measured & paid. |
| 103 | M&L for well burnt sub class \"B\" bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as secified and directed. |
| 104 | M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing upto 80 mm bore complete all as specified and directed. |
| 105 | S&F in replacement GI protection pipe of 80 mm dia light grade for cable protection including all fittings laid in trenches or fixed on pole/ walls with mild steel clamps, bolts, nuts and washers complete all as secified and directed.Note:- Earth work shall be measured and paid separately. |
| 106 | Supply, fixing/ laying, connecting and commissioning LT underground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable with multistranded aluminium conductor,95 sqmm,3.5 core, 1100 Volts grade laid in trenches/ on wall/ poles/ ducts/ pipe including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as secified and directed.Note: Earth work shall be measured & paid separately. |
| 107 | Supply, fixing/ laying, connecting and commissioning LT underground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable with multistranded aluminium conductor,35 sqmm,3.5 core, 1100 Volts grade laid in trenches/ on wall/ poles/ ducts/ pipe including cable glands, lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and directed.Note: Earth work shall be measured & paid separately. |
| 108 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x 6.30 mm thick elecrode and 4mm galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm as earth lead by means ofbolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 20mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I complete all as specified and directed. |
| 109 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |