Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling stone slabs/tiles of any description or thickness in floors, approns etc all as specified and as directed by Engineer Incharge. |
| 2 | Demolition of cement concrete in ground floor & pavings n exc 15cm thick (below or above ground level) all as specified and as directed by Engineer Incharge. |
| 3 | M&L for 40 mm thick Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in sub base all as specified and as directed by Engineer Incharge. |
| 4 | M&L for Heavy duty, Anti skid 300mm x 300mm x 10mm thick Grip series outdoor tiles of colour Star beige/ Teracotta in floors etc. and pattern as approved by Garrison Engineer) set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tileslaid over and including 15 mm thick screed bed orbedding layer of cement mortar (1:6) complete all as specified and directed by Engineer Incharge. |
| 5 | M&L for Pre-cast cement concrete solid block as in kerb stone set in mortar 1:4,Type B-1 1:2:4 using 20 mm graded stone aggregate complete all as specified and as directed by Engineer Incharge. |
| 6 | S&F for 110 mm bore PVC (SWR) type B pipes single socketed, in any length with rubber ring joints, fixed to wall or laid in trenches all as specified and as directed by Engineer Incharge. |
| 7 | S&F for 110mm bore PVC (SWR) bendsall as specified and as directed by Engineer Incharge. |
| 8 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including core cutting, welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement all as specified and as directed by Engineer Incharge. |
| 9 | M&L for Light/Dark shade Granite 18 to 20mm thick colour as approved by Garrison Engineer machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 20 mm thick screed bed in cement mortar (1:6)complete all as specified and as directed by Engineer Incharge. |
| 10 | M&L for Light/ Dark shade Granite 18 to 20mm thick colour as approved by Garrison Engineerin leather finish for top surface of steps tread, skid surface etc with three grooved lines. machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 20 mm thick screed bed in cement mortar (1:6)complete all as specified and as directed by Engineer Incharge. |
| 11 | M&L for Light/ Dark shade Granite 18 to 20mm thick colour as approved by Garrison Engineer machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 10 mm thick backing coat in cement mortar (1:4)complete all as specified and as directed by Engineer Incharge. |
| 12 | M&L for Aluminium Compostie panel in metalic/glossy finish as approved by Garrison Engineer, cut to shape required made out of 3mm thick aluminium composite panel material comprising of 2.5 mm thick FR grade mineral core sandwiched between two aluminium sheets (each 0.25 mm thick) using stainless steelscrews , nuts , bolts, washers, cleats, weather silicon sealant, backer rods etc all as specified and as directed by Engineer Incharge. |
| 13 | S&F Anodised aluminium frame work for ACP panel and like with one or more rebates, screw, anchor bolt, joining cleat etc. complete all as specified and as directed by Engineer Incharge. |
| 14 | M&L for20 mm average thickness of screed layer on RCC slab in cement mortar ( 1:4) including liquid water proofing complete all as specified and as directed by Engineer Incharge.Note :- Water proofing compound will be measured and paid separately |
| 15 | M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces with using water liquid proofing compound and finishing the surface even & smooth without using extra cement complete all as specified and as directed by Engineer Incharge.Note :- Water proofing compound will be measured and paid separately |
| 16 | M&L for Water proofing treatment to RCC roof slab, walls, chhajjas etc,and shall be carried out as specified below and as directed by Engineer-in-Charge.(a) Taking down existing water proofing treatment of any description and layers from wall/roofs including screed bed or bedding layers of mortar of any complete and cleaning the surfaces free from dust and scrubbing down with water.(b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying evenly acoat of approved bituminous primer @ 0.40 Ltr/sqm of area.(c) Providing APP polymer modified approved membrane, non woven,polyester, weighing not less than 3.5 Kg/sqm with laps & overlaps asspecified & joints sealed and applied complete by torch application methodall as specified & directed by Engr-in-Charge. Carrying out test by floodingwater for 24 hrs for leakage & seepages and rectifying the same to theentire satisfaction of GE.(d) Finally applying two coats of solar reflective bituminous aluminium paint@ 0.3 ltr/sqm on the top of membrane surfaces complete all as specified and as directed by Engineer Incharge. |
| 17 | Supply only intergal water proofing compound complete all as specified and as directed by Engineer Incharge. |
| 18 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and getting out in any type of soil complete all as specified and as directed by Engineer Incharge. |
| 19 | M&L forPlain Cement concrete 1:4:8 type D-2, using 40mm graded aggregate) as in foundation fillng and mass concrete complete all as specified and as directed by Engineer Incharge. |
| 20 | M&L for brickwork with Modular fly ash bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed by Engineer Incharge. |
| 21 | M&L for providing cement concrete1:3:6 type C1 (20 mm graded stone aggregateas in copings all as specified and as directed by Engineer Incharge. |
| 22 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and as directed by Engineer Incharge. |
| 23 | M&L forRendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces finished the surface even & smooth without using extra cementin cement all as specified and as directed by Engineer Incharge. |
| 24 | M&L for returning, filling in, including spreading, levelling, watering and well ramming in soil in layers not exc 25 cm all as specified and as directed by Engineer Incharge. |
| 25 | Removing excavated material (soil) not exc. 50m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and as directed by Engineer Incharge. |
| 26 | S&F Mild steel GDE Fe 410-O or Fe 310-O Framed work as in gates, grills, gratings, etc. with ends of bars shouldered or riveted or forged into spikes framed guard bars, barred iron doors and similar work conforming to Fe-290-Gde-E-165 complete all as specified and as directed by Engineer Incharge. |
| 27 | S&F Mild steel GDE Fe 410-O or Fe 310-O Framed work as in gates, grills, gratings, etc. of ornamental and intricate design (Design of gate and grills as approved by Garrison Engineer) with ends of bars shouldered or riveted or forged into spikes framed guard bars, barred iron doors and similar work conforming to Fe-290-Gde-E-165 complete all as specified and as directed by Engineer Incharge. |
| 28 | M&L for 18 to 20 mm thickGranite work (table rubbed and polished) (Colour of granite as approved by Garrison Engineer) as inwash basin platforms, urinal partitions, gate pillarsetc.in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of graniteall as specified and as directed by Engineer Incharge. |
| 29 | M&L for preparation of newly plastered surfaces of wallsProviding and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litreand UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over plastered surfaces all as specified and as directed by Engineer Incharge. |
| 30 | M&L for complete removal of existing treatment by mechanical means on plastered surfaces of walls and Providing and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litreand UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over plastered surfaces all as specified and as directed by Engineer Incharge. |
| 31 | M&L for complete removal of existing treatment by mechanical means on plastered surfaces of walls and Providing and applying wall care putty of total 1.5mm thick in two layers over plastered surface to prepare the surface even and smooth, and applying two coats of acrylic emulsion distemper over and including a coat of primer all as specified and as directed by Engineer Incharge. |
| 32 | M&L for complete removal of existing treatment by mechanical means on plastered surfaces of ceiling Providing and applying wall care puttyof total 1.5 mm thick in two layers over plastered surface to prepare the surface even and smooth, and applyingtwo coats of acrylic emulsion distemper over and including a coat of primer all as specified and as directed by Engineer Incharge. |
| 33 | M&L for preparation of new steel surface and applying two coat of synthetic enamel paint over a coat of red oxide all as specified and as directed by Engineer Incharge. |
| 34 | M&L for preparation of new steel surface and applying two coats of golden paint over a coat of red oxide on small articles ofgates, grills etc and similar atricles when unconnectd with painting or when painted in a different tint all as specified and as directed by Engineer Incharge. |
| 35 | M&L for point wiring (Concealed wiring) of any length using approved colour coding as per IS and IE rule , withmulti stranded copper conductor 1.5 Sqmm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS-H cable,1100 volts grade, conf to IS:694, ISI markedin and includingPVC rigid conduits heavy duty, medium grade,ISI marked (Min 20mm dia )with valid CMLNo. totally concealed in wall/ floor and providing casing caping, ISI marked, not less than 20 mm diato be fix on roof/ ceiling including all accessories as requiredat site complete including GI Metal Flush box (sunken box of min 1.0mm thick) with modular frame/cover plateof suitable sizefor mountingmodular switches/sockets etc and PVC insulatedmulti strandedFRLSH copper conductor 1.5 Sq.mm single core cable (Green colour) as earth conductor and connecting to common earth dolly complete all as specified and directed by Engineer in Charge for the following:- |
| 36 | One light point controlled by one switch one way type |
| 37 | One Ceiling fan/Exhaust fan point controlled by one switch one way type |
| 38 | One 3 pin 5 Amps socket outlet point on Same board |
| 39 | One 3 pin 5 Amps socket outlet point on independent board |
| 40 | All as per item No 35 above but with 2.5 sq mm copper conductor FRLSH (multistrand), 1100 volts grade PVC insulated, ISI marked unsheathed cable in and including concealed PVC conduit heavy duty ,ISI marked, medium grade with valid CML No not less than 20 mm dia with all fitting &accessories as required and including PVC insulated ISI marked, unseathed, FRLSH copper conductor cable of size 2.5 s q mm (Green Colour) as earth wire to common earth dolly complete all as specified and directed by Engineer in Charge, for one three pin socket outlet 15 Amps.Note for Item Sr No 35 to 36i) Contractor shall providecircuit wiring with 3 x 2.5 Sqmmcopper wirefrom DB to switch board and rate for the same is deemed to be included in unit rate of item.(ii) Cutting in chases and pointing in brick wall/Stone Wall shall be done by contractor without any extra cost.(ii) Making good of distrubed surfaces matching with existing finishes shall be done by contractor without any extra cost.(iii) Contractor shall make the surface good after flushing the sunken box as existing without any extra cost(iv) Length of Point wiring for light points/ fan points (ceiling/ exhaust / wall) shall be of suitable length as per site requirement and location of fittings and their switches as directed by Engr-in-charge. The cost of same shall deemed to be included in quoted rates. (v) Contractor shall provide wire mesh before plastering work on chase cutting to avoid cracks developed on surface(vi) GI Sunken box and modular switch socket shall be of same make and sunken box shall be suitable for mounting modular switch and socket as approved by GE. |
| 41 | Dismantling and taking down old US switches, sockets, PVC boxes of any description and cutting holes/ making chases at same / new location for installation ofnew GI Sunken boxes ( to be flush in wall to make the wiring concealed) of required size inlcuding all fixing arrangements and making good of disturbed surfaces to match with adjoining / existing surface complete all as specified and as directed by Engineer Incharge.Note : Cost of new GI metal sunkun box and switch / sockets will be paid separately under relevant items. |
| 42 | M&L for installation of GI modular sunken box of 3 Module ( min 1.0 mm thick)including modular frame and plates all as specified and as directed by Engineer Incharge. |
| 43 | M&L for installation of GI modular sunken box of6 Module (min 1.0 mm thick ) including modular frame and plates all as specified and as directed by Engineer Incharge. |
| 44 | M&L for installation of GI modular sunken box of12 Module (min 1.0 mm thick ) including modular frame and plates all as specified and as directed by Engineer Incharge. |
| 45 | S&F modular switch, oneway, 6 Amps, one module complete all as specified and as directed by Engineer Incharge. |
| 46 | S&F modular socket 6 Amps 2/3 pin,two module complete all as specified and as directed by Engineer Incharge. |
| 47 | S&F modular switch, one way, 16 Amps, one module complete all as specified and as directed by Engineer Incharge. |
| 48 | S&F modular socket 6 Amps/16 Amps 2/3 pintwo module complete all as specified and as directed by Engineer Incharge. Note : Modular switch / sockets and modular sunken box shall be of same make. |
| 49 | S&F ceiling rose, 3 terminals / PVC / Polycarbonate, isolated body complete all as specified and as directed by Engineer Incharge. |
| 50 | S&F LED Tube light fitting 22 watt, surface / wall mounted LED batten housing made of aluminium extrusionwith high efficient LED`s, opal diffuser, IP 20, with system efficacy of 100 lm/W , colour temp 6500 K, 50 Hz, 240 V complete including all accessories internally pre-wired and including connecting up with three core twisted flexiblesheathed copper conductor cable ofsuitable size from ceiling rose to connector of light fittings, incl 2 x PVC mounting box for fixing of light complete as directed by Engineer in Charge .Cat Part No- Halonix HLB-03-22-CW-AL-SQ or equivalent inLuker - LUMOS PRIMO Aluminium tube set-LT-522 , or equivalent as mentioned in Appendix C to Tender Document. |
| 51 | S&F LED Tube light fitting 20 Watt,Surface/wall mounted/ suspended LED decorative batten, CRCA housing batten with extruded aluminium heat sinkforefficient heat dissipation,with built in electronic driver having THD<10%,Milky white polycarbonate diffuser and elegant designed white coloured ABS endcaps , heavy duty driver,20 W LED, colour temp 6500 K, complete including all accessories internally pre-wired, in and including 2 x PVC box / 2 x suspension clamp,connecting up with sheathedflexible copper wire three coreofsuitable size from ceiling rose to connector of light fittings all as specified and as directed by Engineer Incharge.Cat Part No . STOUTMIN11200BSGEN20WLED865SPCWHor equivalent as mentioned in Appendix C to Tender Document. |
| 52 | S&F LED Tube light fitting 10 Watt,Surface / wall mounted LED batten housing made of aluminium extrusion with high efficient LED`s, opal diffuser, IP 20, with system efficacy of 100 lm/W , colour temp 6500 K, 50 Hz, 240 V complete including all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable ofsuitable size from ceiling rose to connector of light fittings, including 2 x PVC mounting box for fixing of light complete all as specified and as directed by Engineer Incharge.Make- Halonix Cat Part No . HLB-03-10-CW-ALSQ or equivalent as mentioned in Appendix C to Tender Document. |
| 53 | S&F LED Ceiling Light, IP65 10W,White,including fixing arrangemet all as required at site and all as specified and as directed by Engineer Incharge.Make :- Luker product code no -GESTO LBKRDSL 10 or equivalent as mentioned in Appendix C to Tender Document. |
| 54 | S&F LED Security light fittings 35/36 Watt with PDC aluminium housing with energy efficient LEDs, Direct modular IP Lens, IP 66 with potted driver and with system efficacy of 125 lm/watt top opening separate driver compartment, IK 07 complete with all accessories such as MS flat iron clamp - 02 Nos , nut, bolts, GI pipe mounting bracket min 32 mm dia of length upto 1.5 mtretc, prewired, connecting light fitting to light source (ceiling rose) with sheathed three core flexible copper wire in PVC flexible pipe of 15 mm dia all as specified and as directed by Engineer Incharge.Make :- Luker Cat part no - HLSLD-14-36-CWDL-R-P or equivalent as mentioned in Appendix C to Tender Document. |
| 55 | S&F in repair / replacement surface mounted LED Panel light 40 W LED of size 600mm x 600mm x 35mm, 240 Volts, colour temp 6500 K with glare free symmetrical illumination suitable for ceiling, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with three core wire, all acessories as required for fixing the light fitting and matching to the adjacent ceiling surfaces all as specified and as directed by Engineer Incharge.Make :- Halonix Cat Part No - HLFPS22-02-40-CW-R, Luker - modelno - LNPSRS 40 (IRIS Surface Panel or equivalent as mentioned in Appendix C to Tender Document. |
| 56 | S&F exhaust fan300 mm sweep, wall mounted, Grey colour, metal body with metal body louvers, 3 blade,heavy duty single phase suitable for 230 volts, 50 HZ,1400 RPM andair deilvery 1250 CMH,and connecting up complete including making electric connectionby providing 1.0 Sqmm x3 core flexible sheathed copper cable from ceiling rose to connector of fanin flexible PVC pipe of min 15 mm dia incl all acessories and including all fixing arrangement to fix onwall by making circular hole of suitable size incl all civil work, make good of surface as adjoining and providing all material required at site for installation of exhaust fan in toiletall as specified and as directed by Engineer Incharge.Note :- The contractor shall make all necessary arrangementfor fixing exhaust fan on wallby making opening including all civil work,making good surface as adjoining and provide all material required on site (like Ply board/PVC board of min 6 mm thickas base etc for installation of exhaust fan) and the cost of the same shall be deemed to be included in quoted rate and noting extra on this account is admissible. |
| 57 | S&F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 8 way Double door enclosure made up of CRCA sheet steel, powder coated, IP 43, as per IEC 61439-3, suitable for flush mounting and surface mounting, with neutral bar, earth bar and cable ties for cable management, fully shrouded neutral bar, prefitted masking sheet, reversible door including blanking plates and taking down old US MCB DBs and fixing the DB box flush in wall of any type and making good the distrubed surface to match with the adjoining/ existing surfaces all as specified and directed by Engineerr-in-charge. |
| 58 | S&F MCB SPN 32 Amps, 240V,10 KA , C curve including complete with connection testing and commissioning all as specified and directed by the Engineer-in-Charge. |
| 59 | S&F MCB SP 6 to 32 Amps 240V,10 KA, C curve, including complete with connection testing and commissioning all as specified and directed by the Engineer-in-Charge. |
| 60 | S&F DB Box, in sheet metal enclosure VT DB TPN, 4 way, double door with MCB as incomer (suitable for mounting 63 Amp MCB) and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, As Per IEC 61439-3, with 100 Amp fully insulated copper bus bar for each phase, with 2 Neutral bar, 2 Earth bar and cable ties for cable management, with fully insulated busbar and shrouded neutral bar, reversible door provision, with colour coded interconnecting wire set,, reversible door provision, blanking plates of and circuit identification labels, including flushing and fixing DB box neatly in wall / solid block wall including copper lugs/thimbles duly crimped for connection complete all as specified and directed by the Engineer-in-Charge.Note :- (i) MCB shall be measured & paid seperately |
| 61 | S&F MCB TPN 63 Amps,415V, 16 KA breaking capacityas per IS/IEC 60898-1 2002all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing all as specified and directed by the Engineer-in-Charge..Note for item No 53 to 57 :- (i) Contractor shall provide MCB and DB box of same make. |
| 62 | M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including through surfaceconduit, including PVC casing capping,heavy duty, ISI marked not less than 25 mm dia , with valid CML No, double locking type in any type of wall/floor, etc, with all connected fittings, including PVC insulated unsheathed 4.0 Sq mm FRLSH cable with multistranded copper conductor of green colour as continuous earth conductor cable connected to earth dolly and make good to match with the existing surfaces after completion all as specified and directed by the Engineer-in-Charge.Note :-(i) Two runs of 04 Sqmm cable with 01 run of 4 Sqmm earth wire along with PVC casing capingshall be measured as one unit length. |
| 63 | M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, FRLSH cable drawn in but including through surfaceconduit, including PVC caing capping,heavy duty, ISI marked not less than 25 mm dia , with valid CML No, double locking type in any type of wall/floor, etc, with all connected fittings, including PVC insulated unsheathed 6.0 Sq mm FRLSH cable with multistranded copper conductor of green colour as continuous earth conductor cable connected to earth dolly and make good to match with the existing surfaces after completion all as specified and directed by the Engineer-in-Charge.Note :-(i) Two runs of 06 Sqmm cable with 01 run of 6 Sqmm earth wire along with PVC casing capingshall be measured as one unit length. |
| 64 | S&F LED Flood light, 30W, White,Energy saving , enviorment friendly, long life, made up of pressure die cast aluminium housing with toughened glass and high power LED`s and secondary lenses withIP 66 protection ,having system efficacy > 100 Lumen Per Watt inclusive of driver, 10 KV SPD and all acessories, Light fitting suitable for highlightingarchitectural facade and general purpose lightingsincludingproviding all fixing arrangements, studs , nut bolts, washers and flat iron clamp for fixing of light on PCC plateformall as required at sitetohighlightingarchitectural facade/ trophyall as specified and directed by Engineer-in-Charge.Make:- Luker- Alcor SY LED flood light Cat Part No LFL30TGLNSY or equivalent as mentioned in Appendix C to Tender Document. |
| 65 | S&F LED Flood light, 50W, White,Energy saving , enviorment friendly, long life, made up of pressure die cast aluminium housing with toughened glass and high power LED`s and secondary lenses withIP 66 protection ,having system efficacy > 100 Lumen Per Watt inclusive of driver, 10 KV SPD and all acessories, Light fitting suitable for highlightingarchitectural facade and general purpose lightingsincludingproviding all fixing arrangements, studs , nut bolts, washers and flat iron clamp for fixing of light on PCC plateformall as required at sitetohighlightingarchitectural facade/ trophyall as specified and directed by Engineer-in-Charge.Make :- Luker Alcor SY LED flood light Cat Part No LFL50TGLNSY or equivalent as mentioned in Appendix C to Tender Document. |
| 66 | S&F LED Flood light, 100W, White,Energy saving , enviorment friendly, long life, made up of pressure die cast aluminium housing with toughened glass and high power LED`s and secondary lenses withIP 66 protection ,having system efficacy > 100 Lumen Per Watt inclusive of driver, 10 KV SPD and all acessories, Light fitting suitable for highlightingarchitectural facade and general purpose lightingsincludingproviding all fixing arrangements, studs , nut bolts, washers and flat iron clamp for fixing of light on PCC plateformall as required at sitetohighlightingarchitectural facade/ trophyall as specified and directed by the Engineer-in-Charge.Make:- Luker Alcor SY LED flood light Cat part No - LFL100TGLNSY or equivalent as mentioned in Appendix C to Tender Document. |
| 67 | S&F LED Flood light, 150W, White,Energy saving , enviorment friendly, long life, made up of pressure die cast aluminium housing with intigrated IP lens and SMD LED`s withIP 66 protection ,having system efficacy > 110 Lumen Per Watt inclusive of driver, 10 KV SPD and all acessories, Light fitting suitable for highlightingarchitectural facade and general purpose lightingsincludingproviding all fixing arrangements, strut , nut bolts, washers and flat iron clamp for fixing of light on PCC plateformall as required at sitetohighlightingarchitectural facade/ trophyall as specified and directed by the Engineer-in-Charge. Make :- Luker Alcor LED SY flood light Cat part No - LFL150TGLNSY or equivalent as mentioned in Appendix C to Tender Document. |
| 68 | S&F LED Flood light, 200W, White,Energy saving , enviorment friendly, long life, made up of pressure die cast aluminium housing with intigrated IP lens and SMD LED`s withIP 66 protection , having system efficacy > 110 Lumen Per Watt inclusive of driver, 10 KV SPD and all acessories, Light fitting suitable for highlightingarchitectural facade and general purpose lightingsincludingproviding all fixing arrangements, strut , nut bolts, washers and flat iron clamp for fixing of light on PCC plateformall as required at sitetohighlightingarchitectural facade/ trophycomplete all as specified and directed by the Engineer-in-Charge.Make :- Luker Alcor LNSY LED flood light, Cat part No - LFL200TGLNSY or equivalent as mentioned in Appendix C to Tender Document. |
| 69 | S&F LED Bollard light fitting,12 Watt, warm white, IP - 54, 2 feet height including fixing arrangement and electric connectioncomplete all as specified and directed by the Engineer-in-Charge.Make :- Luker Product code No - DUNE B7 ,LODBR12 or equivalent as mentioned in Appendix C to Tender Document. |
| 70 | S&F LED Facade light fitting green colour , IP54,30W, Green including fixing arrangement complete all as specified and directed by the Engineer-in-Charge.Make :- Luker Cat part No - Cube S6- LODSP30 or equivalent as mentioned in Appendix C to Tender Document. |
| 71 | S&F LED Flood light fitting green colour , IP54,50W, Green including fixing arrangement complete all as specified and directed by the Engineer-in-Charge.Make :- Luker Alcor SGLED flood light, Cat part No - LFL50NSG(Green) or equivalent as mentioned in Appendix C to Tender Document. |
| 72 | S&F LED Flood light fitting green colour , IP54,100W, Green including fixing arrangement complete all as specified and directed by the Engineer-in-Charge.Make :- Luker Alcor LNLED flood light, Cat part No - LFL100LN(Green) or equivalent as mentioned in Appendix C to Tender Document. |
| 73 | S&F LED Gate light (Post Top Lantern) outdoor type, IP 54, 18 Watt, Warm Whiteincluding fixing arrangements, gate light base and all acessoriescomplete all as specified and directed by the Engineer-in-Charge.Make :- Luker Cat part No - Zeus Post Top LED Light or equivalent as mentioned in Appendix C to Tender Document. |
| 74 | S&F LED Post Top light, outdoor type, IP 54, 60 Watt, WH (White)including fixing arrangements and all acessories to be fixed on 09 mts height existingsteel tubular pole complete all as specified and directed by the Engineer-in-Charge.Make :- Luker Product code No - Zeus Post Top LEd Light or equivalent as mentioned in Appendix C to Tender Document. |
| 75 | Note :- The contractor shall provide minimum 2 years on site warranty from OEM for All LED light fittings/flood lights/Bollard/Post Top Laten. |
| 76 | S&F Grey Plexo box & adaptor with PVC membrane -1 row X 3 module 230V, 50 HZ, IP-55 & IK-09 Class-II, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty-1 Nos including 15Amps Switch and Sockets, 240 V, 50 HZ - 01 No and all wiring and making electrical connection complete all as specified and directed by Engineer-in-Charge. |
| 77 | M&L Painting ofsteel pole (swan neck or straight Pole any type) up to 12 mtr heightwith cross arms, clamp of any length and shape for LT overhead line/ for street lightwith two coat of aluminium paint after scratching out old paint, cleaning and exiting surface rust free, preparation of the existing surface,including marking pole numbers in a 15 cm dia yellow circle with number writting with blacksyenthic paint/ Stricker, includingpainting strips in alternate from bottom to top with three strips of black syntheticpaint & two strips of Yellow/ Sky blue paint(as per existing pattern through out the circumference of pole, including one coat of lime wash on PCC copping of pole complete all as specified and directed by the Engineer-in-Charge. |
| 78 | M&L for fixing of GI pipe 40 mm dia medium grade of length 45cm with GI socket, MS frame made up of flat iron of size 50 x 5 x 200 mm frame structure, including drilling, welding, bending, and making the holes complete as required at the site for fixing/mounting of flood / facade light fitting, including excavation in any type of soil for grouting 1/6 of the length of the pipe belowground level and PCCin 1:2:4 ( 20 mm graded stone aggregate) coping of 100 mm heightto be made above ground level complete all as specified and directed by the Engineer-in-Charge. |
| 79 | M&L for fixing of GI pipe 40 mm dia medium grade of length 1.5 mtr with GI socket, MS frame made up of flat iron of size 50 x 5 x 200 mm frame structure, including drilling, welding, bending, and making the holes complete as required at the site for fixing/mounting of flood / facade light fitting including excavation in any type of soil for grouting 1/6 of the length of the pipe belowground level and PCC coping of 150mm heightto be made above ground level complete all as specified and directed by the Engineer-in-Charge. |
| 80 | M&L for fixing of GI pipe 40 mm dia medium grade of length 3.0m with GI socket, MS frame made up of flat iron of size 50 x 5 x 200 mm frame structure, including drilling, welding, bending, and making the holes complete as required at the site for fixing/mounting of flood / facade light fitting, including excavation in any type of soil for grouting 1/6 of the length of the pipe belowground level and PCC coping of 150mm heightto be made above ground level complete all as specified and directed by the Engineer-in-Charge.Note for item No 73 to 75:- The PCC coping to be measured and paid separately. |
| 81 | M&L for PCC foundation, PCC 1:3:6, type C1 (using 20mm graded stone aggregate) and making all as specified for mounting GI pipe and LED light fitting including necessary excavation work, complete all as specified and directed by the Engineer-in-Charge. |
| 82 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) for coping around poles , including necessary form work finishing even and smooth without using extra cement ,complete all as specified and directed by the Engineer-in-Charge. |
| 83 | M&L for shifting of existing LT steel tubular pole by cutting from the bottom of the pole and erecting the same as directed by the Engr- in -charge near the open museum building with the help of JCB & Crane as required at the site complete all as specified and directed by the Engineer-in-Charge.(Note - The cost of the excavation and earthwork in any strata including PCC in 1:3:6 (20mm graded stone aggregate) is deemed to be included in quoted rate and noting extra on this account will be admissible) . |
| 84 | Supply install testing and commissioning Auto timer switch for auto ON/ OFF of street lights/ any type of light fittings in sheet steel enclosure, including all accessories like contactor,digital timer switch , MCB, pre wired, of 40 Amp , 3 Pole, 230 Volt, digital timer switchincluding making all electrical connections , fixing of timer switch box by providing4 Nos 35x35x4mm thick angle iron supports of not less than each 0.6 mt height duly painted with anti-corrosive black paint and grouted in PCC 1:3:6 at suitable depth as per site requirement, incl excavation and all earth work complete all as specified and directed by the Engineer-in-Charge.Make :- INDOASIAN Cat No:- TL040DB0, TIMELITE DISTRIBUTION BOARD or equivalent as mentioned in Appendix C to Tender Document. |
| 85 | Supply of Customized CNC / Laser Cut Heavy duty LED Bollard specially designed with \"NDA\" word and \"NDA Logo\" (Font and Logo size72 X 60 mm), Bollard height 800 mm with MS Body with min 2.2 mm Thickness , Luminaire System Wattage should be 12 -15W , with PF > 0.95 CRI > = 70 andITHD % < 20at full load. Input Supply Voltage Range:150 -270 V, Frequency :50-60 HZ;Internal Surge Protection: 2.5 KV LED driver , Reverse Polarity, Open & Short Circuit . Luminaire CCT to be 2700K + 200 K. Product should be IP65. Luminaire base 150mmX150mm and height 800mm complete all as specified and directed by the Engineer-in-Charge. |
| 86 | Supply and laying of40mm outer dia, double walled corrugated DWC pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed by Engineer Incharge. |
| 87 | Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade, ISI marked, with valid CML No. of stranded aluminium conductor of size 10 sqmm 4 core, laying in undergound in trenches or on surface by providing proper GI clamps or in protection pipe including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends complete all as specified and as directed by Engineer Incharge.. |
| 88 | Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade, ISI marked, with valid CML No. of stranded aluminium conductor of size 6 sqmm 2 core, laying in undergound in trenches or on surface by providing proper GI clamps or in protection pipe including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends complete all as specified and as directed by Engineer Incharge.. |
| 89 | S&F PVC insulated, PVC sheathed copper cable of size 1.5 sqmmx 3 core conforming to relevent IS,ISI markcomplete all as specified and as directed by Engineer Incharge.Note:- The cost of providing flexible PVC pipe for protection of flexible cable as required to be deemed to included in quoted rate and nothing extra shall be admissible on this account. The contractor shall provide flexible PVC pipe for protection of flexible cable as per requirement without any extra cost complete all as specified and as directed by Engineer Incharge. |
| 90 | S&F distribution box/Plexo Boxes 2 Module 230V, 50 HZ, IP-65 & IK-09 Class-II, including 10 Amp SPN MCB 10 KA, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty-1 Nos, including end caps, 15/16 amps switches, 3 pin 15/16 ampssockets complete all as specified and as directed by Engineer Incharge. |
| 91 | Supply and installation weather, dust and vermin proof Feeder Pillar box (Cubical Panel box)factory made, outdoor type of 3.15 thickness of min size 450 x 400 x 300 mm to accommodateMCCB 3/4 pole upto 100 Amps rating - 01 No, IP 54, front openable type, with locking arrangement, powder coated mounted on MS angle iron frame of size 40 x 40 x 6 mm welded in shape, painted with two coats of synthetic enamel paint over a coat of red oxide primer including necessary grouting in PCC 1:3:6 type C - 1 using 20 mm graded coarse stone aggregate complete with leg 45 cm grouted in PCC and 40 cm above ground including making all electrical connection with glands etc. complete all as specified and as directed by Engineer Incharge. |
| 92 | S&F MCCB with Thermal - magnetic release of 63 Amps,4 Pole, 415V, 16 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting as per IS-13947 & IEC 60947-2 including all accessories like spreader terminals and face barriers including making all electrical connections by providing lugs of suitable size lugs including fixing of MCCB in feeder pillar boxcomplete all as specified and as directed by Engineer Incharge. |
| 93 | S&F Thermoplastic cable junction box of size 155mm x 210mm x 92mm , IP 66 , halogen free and weather proof with locking arrangement and necessary mounting arrangement on pole by providingMS clampwith nut , boltand double washer , for out door installation complete withconnector terminal for connecting cable, knockouts for cable entry up to the size of 10 Sqmm x 4 core,making connection of cable by providing suitable size cable lugs and PVC glands complete all as specified and directed by Engineer-in-charge. Make :- Hensel Cat No :- KF 1610 B or equivalent as mentioned in Appendix C to Tender Document.Note :- The Contractor shall provide cable lugs andPVC gland of suitable size if required on site for connecting cable in junction box. |
| 94 | S&F Thermoplastic cable junction box of size 240mm x 130mm x 110mm , IP 66 , halogen free and weather proof with locking arrangement and necessary mounting arrangement on pole by providingMS clampwith nut , boltand double washer , for out door installation complete with 3 Phase and Neutral bus bar for termination of cables,knockouts for cable entry up to the size of 10 Sqmm x 4 core,making connection of cable by providing suitable size cable lugs and PVC glands complete all as specified and directed by Engineer-in-charge. Make :- Sintex SMC FRP or equivalent as mentioned in Appendix C to Tender Document.Note :- The Contractor shall provide cable lugs andPVC gland of suitable size if required on site for connecting cable in junction box. |
| 95 | S&F Non metallic PVC Heavy grade (HMS) conduit 20 mm dia, ISI marked, white in colour for drawing aluminium/ copper conductor cable from junction box to light fitting including fixing the conduit on wall/surface by providing GI clamp and buried of conduit in trench in underground including excavation as per site requirement complete all as specified and as directed by Engineer Incharge.Note :- The Contractor shall provide flexible PVC pipe for protection of flexible cable as per requirement without any extra cost. |
| 96 | M&L for cutting of road / hard standing/ path for laying of cables in underground through protection pipe of size of trench width 45 x depth 45 Cm and making good with PCC (1:2:4) type B 1 (using 20 mm graded stone aggregate) complete all as specified and as directed by Engineer Incharge. |
| 97 | M&L For Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick,buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level),connected to galvanised steel earthing lead wire 4 mm dia, by means of bolts, nuts & checknuts and washers etc;GI pipe15 mm dia light grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 5 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1(using 20mm graded stone aggregate) earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata & testing on completion, complete all as specified and as directed by Engineer Incharge and shown on drgs. |
| 98 | M & L for fabrication of Glow Sign Board made up of white colour acylic sheet albhabate letters with LED lights, each letter having600 mm height x 25 mm depth and- Total letters 15 Nos written as (TRISHAKTI MUSEUM) and NDA Logo - 02 Nos to be fixed on both ends and of same height as that of letters, all letters and NDA logo to be fixed onsuitable size rectangular shape ACP Sheet of Burgundry colour (NDA colour). ACP sheetto be fixed onsquare section hollow MS tube (of min size 25 mm) base frame duly painted with two coat of syenthtic enamel paint over one coat ofred oxide primer including nut, bolts, washer , stuts and all fixing arrangements to fix the board on Trishakti open museum bldg and making all electrical connection for LED light fittings, 1.0 sqmm x 3 core sheathedcopper cable from source to glow sign boardcomplete all as specified and directed by engineer in charge. Note :- The conteractor shall visit office of AGE (E&M) of GE(P) NDA K\"wasla for sample board before quoting the rates. The board shall be same as per the sample shown and nothing extra on this account will be admissible. |
| 99 | Notes :- i) The Glow Sign Board should be of suitable Lengthto accommodate all letters and NDA Logo Lettering Margin of 300 from all sides.ii) The contractor shall submit the warranty certificate for board and any colour fadedness of ACP sheet & LED Lights fixed as alphabet letters and logo and fixing of letters and Logos on board complete for two years. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail