| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" Part-I (Building/Structures) (To be quoted by the tenderer) |
| 2 | Item No 01 : Design and constructionof OPD COMPLEX ALONGWITH DEPARTMENT OF EMERGENCY AND TRAUMA CARE complete all as specifiedin soil bearing capacity report, design basis report, drawings and tender documents. |
| 3 | Item No 02 : Design and constructionof AC Plant Room complete all as specifiedin soil bearing capacity report, design basis report, drawings and tender documents. |
| 4 | Item No 03 : Design and constructionof UG Sump 100000 Gallon) complete all as specifiedin soil bearing capacity report, design basis report, drawings and tender documents. |
| 5 | Sch \"A\" Part-II (External Water supply)Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule \"A\" Part-II against the lump sum price inserted by the MES. |
| 6 | Sch \"A\" Part-III (External Water supply)Lump sum price worked out by the contractor for (External Water supply) as listed in Schedule \"A\" Part-III against the lump sum price inserted by the MES. |
| 7 | Sch \"A\" Part-IV(Road Path Culvert)Lump sum price worked out by the contractor for (Road Path Culvert) as listed in Schedule \"A\" Part-IV against the lump sum price inserted by the MES. |
| 8 | Sch \"A\" Part-V (Sewage Disposal)Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule \"A\" Part-V against the lump sum price inserted by the MES. |
| 9 | Sch \"A\" Part-VI(Area Drainage)Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule \"A\" Part-VI against the lump sum price inserted by the MES. |
| 10 | Sch \"A\" Part-VII(Compound Wall)Lump sum price worked out by the contractor for (Compound Wall) as listed in Schedule \"A\" Part-VII against the lump sum price inserted by the MES. |
| 11 | Sch \"A\" Part-VIII (Hot water)Lump sum price worked out by the contractor for (Hot water) as listed in Schedule \"A\" Part-VIII against the lump sum price inserted by the MES. |
| 12 | Sch \"A\" Part-IX(Conduit for PA system)Lump sum price worked out by the contractor for (Conduit for PA system) as listed in Schedule \"A\" Part-IX against the lump sum price inserted by the MES. |
| 13 | Sch \"A\" Part-X (Water cooler)Lump sum price worked out by the contractor for (Water cooler) as listed in Schedule \"A\" Part-X against the lump sum price inserted by the MES. |
| 14 | Sch \"A\" Part-XI(Refrigeration)Lump sum price worked out by the contractor for (Refrigerationn) as listed in Schedule \"A\" Part-XI against the lump sum price inserted by the MES. |
| 15 | Sch \"A\" Part-XII (Fire detector system/ alarm Sysem)Lump sum price worked out by the contractor for (Fire detector system/ alarm Sysem) as listed in Schedule \"A\" Part-XII against the lump sum price inserted by the MES. |
| 16 | Sch \"A\" Part-XIII(Fire Fighting)Lump sum price worked out by the contractor for (Fire Fighting) as listed in Schedule \"A\" Part-XIII against the lump sum price inserted by the MES. |
| 17 | Sch \"A\" Part-XIV(Site Clearance and development)Lump sum price worked out by the contractor for (Site Clearance and development) as listed in Schedule \"A\" Part-XIV against the lump sum price inserted by the MES. |
| 18 | Note for Srl No 3 to 17The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 3 to 17by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 19 | Schedule \"A\" Part-XV (Miscellaneous items of works) |
| 20 | Lift |
| 21 | Item No 04 :Design supplying, installing, testing & commissioning of electrically operated gearless 15 Passengerof size 1000x 2400 mm(1020 Kg capacity) suitable for hospital strecherlifts to serve 3 floors i.e. G + 2 upper floors in thelift well as available , confirming to all relevant IS, speed 1.5 metre/sec with automatic micro stroke button control, microprocessor based controller, simplex selective/ collective control suitable for 3 phase, 415 volts, 50 Hz, AC supply,independent operation with AC Variable Voltage Variable Frequency [AC VVVF] drive control [closed loop] with power saving regenerative drive with suitable gearless motor traction type to serve G+2 floors i.e. 3 stops and 3 landings |
| 22 | (Travel/ rise 30M approx) with and without attendant, suitable for synchronised operation, automatic power operated 1000mm centre opening sliding type stainless steel (SS 304) doors 16 gauge haireline finish with vision panel of size 300x1700mm covered with 8mm thick toughened plain glass, having full curtain infrared sensor safety (3D infra red sensors for car doors along the full height), UPS based Automatic Rescue Device [ARD] system with [±] 5mm and suitable batteries, Floor position digital indicators in car and all landings with call indicating lights, built in voice announcing system including necessary joists and beams for mounting the machine in machine room , all necessary civil works required in connection with erection of lift complete all as specified and as directedcomplete all as specified and as directed. |
| 23 | Notes: The lift shall be provided with and including the following: [a] Fireman Switch[b] UPS based Automatic Rescue Device [ARD] during power failure including manual operation provision with suitable capacity of batteries designed for running the lift with full load. The ARD batteries shall be securely housed in a suitable battery box fabricated from 1.5 mm thick mild steel (MS) sheet, duly powder coated for corrosion resistance with an insulating mat provided inside to ensure electrical safety and prevent direct contact between the batteries and the metallic surface.with suitable locking arrangemement.[c] Battery operated emergency light [LED Ceiling Fitting] alarm [speaker for emergency alarm system to be fixed] and stop button in car with rechargeable arrangement for battery.[d] LED light fitting 5 Watts x 6 Nos. recessed mounted in false ceiling.[e] Provision of two axial flow fans suitable for recessed mounting in false ceiling.[f] Provision of premium quality Jet blacj Granite stone slab of 18-20 mm thick as in flooring for lift car (not more than two parts) over 3mmthick aluminium chequered plate in flooring for lift car. |
| 24 | [g] Nonstop button/ independent operation.[h] Over load warning indicator in COP with voice announciation and overload protection/ tripping system having relays , etc.[i] Stainless steel sliding doors with front opening for all landings made of 16 gauge 304 grade stainless steel sheet with haireline finish with vision panel of size 300x1700mm covered with 8mm thick toughened plain glass.[j] Landing door frames shall be made of 1.5mm thick 304 grade stainless steel sheet. |
| 25 | [k] All the dimensions of the lift and connected items shall be designed in conformity with IS 14665 standards and the contractor shall submit the design drawing to Accepting Officer for approval before commencementof work. The body shall be SS 304 grade stainless steel of 16 gauge with hairline finish.[l]Provision of built-in voice announciating system for floor announciation, direction of lift movement i.e. going up and going down announciation with background music complete all as specified, directed and approved by Engineer-in-charge/GE.[m] Provision of voice announciating system for ARD operation during power failure complete all as specified, directed and as approved by Engineer-in-charge/GE.[n] Set of three in number limit switches at the bottom and top most position of lift hoist way as specified in IS.[o]A safety instructions plate, duly embossed or laser printed on an SS 304 sheet, shall be riveted inside the lift car at a clearly visible location, displaying the content in English, Hindi, and Telugu with letters of sufficient size to be easily readable by the users.as approved by the Enginee-in-Charge |
| 26 | [p]Provision of Car Operating Panel (COP) with a dot matrix type display to indicate various information such as floor level, directional arrow, overload, ARD functioning, and other relevant signals, along with push buttons incorporating Braille/raised letters in sharp contrast to the background, to aid persons with visual impairments in compliance with Clause B-6.4.5 (c) of NBC of India 2016.[q] Provision of suitable phase reversal relays to the controller to protect lift/ equipment against phase reversal, phase failure and low voltage.[r] Provision of 3 way Intercom system with hand set at Ground floor and machine room andbuilt in push to talk(PTT) in COP without hand set.[s] Provision of hand rail made out of 38mm dia 304 grade stainless steel pipe with closed and smooth finished complete all as specified and as directed by Engineer-in-charge.[t] Continuous earthing for machine and equipment with Aluminium strip of size 25x3mm from machine unit and controller panel up to the earth test point provided at the bottom of the bldg. New earth pits-02 Nos shall be provided with 600mmx600mmx6mm GI earth plate electrode and 32x6mm earth strip from earth electrode to test point shall be provided. |
| 27 | [u] Steel Wire rope of adequate size as per relevant IS and as per manufacturers specification.[v] Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards, buffers, gear unit brakes, control panel, car operational panel, governor, locks, power control and trailing cables complete all as per revelent IS specifications. [w] Main drives and controls shall be high efficient and low power consumption.[x] Lift design, specifications, drawings, manufacturers instructions shall be got approved from Accepting Officer before placing order for procurement.[y] The contractor shall carry third party load testing for each lift installed once in every six months till defect liability period and shall submit staisfactory test results and the rate quoted shall be deemed to included for this provision.[z] Shaft lighting shall be provided in the lift shaft with provision of LED Bulk head light 10W at each floor level with FRLS copper conductor wires drawn through PVC conduit. The wiring for shaft lighting shall be connected and controlled from machine room lighting and it shall be independent from lift supply. |
| 28 | [aa] Provision of CCTV Camera, 3MP, 2K, made in India with 256GB Micro SD memory card housed in a stainless steel safety grill with small padlock complete fixed in lift car. A separate UPS with battery, suitable to provide a minimum of 15 minutes backup for the CCTV system, shall be installed in the machine room, and the power supply to the CCTV shall be connected from the UPS through an independent cable drawn along with the trailing cable.[ab] Directional signs indicating the location of an accessible lift to transport persons with disabilities at all usable levels shall be provided at a location that is clearly visible from the accessible building entrance. The directional signs shall incorporate a representation of the International symbol of accessibility in compliance with Clause B-6.4.1 of NBC of India 2016.[ac] Provision of Landing Operating Panel (LOP) at all floors with a dot matrix type display to indicate both the floor level and directional arrow, along with push buttons incorporating Braille/raised letters in sharp contrast to the background, to aid persons with visual impairments in compliance with Clause B-6.4.5 (c) of NBC of India 2016.[ad]Solid Cast Iron blocks only shall be used for Counterweight. No other castings shall be permitted. |
| 29 | [ae] The mild steel machined guide rails shall only be permitted.The minimum thickness of guide rails shall be 16 mm for the car and 10 mm for the counterweight.[af] Automated Breakdown Notification System: The lift shall be equipped with an intelligent controller capable of detecting and diagnosing faults or malfunctions in real time. In the event of any lift breakdown or critical fault, the controller shall automaticallytrigger on SMS. Upon rectification of the fault and restoration of functionality, the system shall automatically trigger a follow-up SMS indicating that the lift is operational.[ag] SMS Alert Configuration: The system shall be configured to send SMS messages to the designated personnel, including but not limited to the following:-[i] Lift Technician[ii]Engineer-in-Charge[ah] Content of SMS Alert: Each SMS alert shall clearly mention the following:-[i] Building Number / Name where the lift is installed[ii]Time and date of fault occurance[iii] Primary cause of breakdown, such as Voltage fluctuation, No power supply, OPverload / Overweight, Emergency stop triggered and any other specific error detected by the system. |
| 30 | [ai] Responsibility of Vendor / OEM: [i]The contractor/vendor shall ensure complete configuration and testing of the SMS alert system at the time of commissioning.[ii]Any necessary SIM card, GSM mobile, or associated hardware / software required for this functionolity shall be supplied and installed by the vendor.[iii] The vendor shall provide documentation and training for the configuration and update of alert recipient numbers.[aj] Compliance & Acceptance: This feature shall form an essential part of the technical compliance. Absence or non-functionolity of the SMS based alert system shall be treated as a deviation from the technical specifications and may attract penalities or non-acceptance during commissioning.[ak] Providing and fixing landing toe guards from the bottom of the sill support up to the next floor door header level to cover the exposed wall surfaces with 1.2 mm thick G.I. sheets, complete with all necessary fixing accessories, fastners and supports to the wall surface, as specified and directed by the Engineer-in-Charge. |
| 31 | Note For Serial Item No. 1 to 1.4: The pre-dispatch factory inspection of the complete material shall be carried out at the manufacturer’s premises by a representative nominated by the Accepting Officer . A report shall be prepared duly signed by the representative of the manufacturer, contractor, and the representative of the Accepting Officer, and shall be approved by the Accepting Officer before dispatching the material from the manufacturer’s factory. The contractor, in liaison with the manufacturer, shall make all necessary arrangements for the inspection and intimate the department at least 15 days prior to the date of inspection. |
| 32 | Phase-II: Schedule \"A\" Part – II: [Comprehensive Maintenance of Lifts provided under item No. 1 to 1.4 above after completion of defects liability period]: |
| 33 | Item No05 : Comprehensive Maintenance of Electrically operated Passenger Lift of 15 Passenger (1020 Kg) Capacity to serve 3 Floors (i.e G+2 upper floors) as mentioned under revelent item of Phase-I with collective / selective control by carrying out periodical checks, repairs including Replacement of defective spares / accessories etc. and testing as specified and as recommended by the OEMto ensure smooth, safe and efficient functioning during first year after expiry of defects liability period complete all as specified in Particular Specifications and as directed. |
| 34 | Item No06 : All as per description of item No. 2.1 but for second year after expiry of defects liability period. |
| 35 | Item No07 : All as per description of item No. 2.1 but for third year after expiry of defects liability period. |
| 36 | Notes for Serial Item No. 06 to 07 above:[a] The contractor shall be required to employ Minimum 01 No. of lift Mechanic with sound knowledge and adequate experience Round the Clock. All the manpower employed shall report to Office of AGE [E/M]/ Complaint Cell for day to day maintenance and efficient operation of Lifts.[b] The rate quoted is deemed to be inclusive of supply and fixing of all Major and Minor Spares viz. Mechanical / Electrical / Electronic / LED Lights etc.as and when required for trouble free, smooth and efficient functioning of lifts including overhauling as and when required to all mechanical parts of lifts, Rewinding of Electric Motors, repair/maintenance of Gear Unit, repair / maintenance of Door Drive, Controllers, Pulleys, Limit Switches, Relays etc. complete all as directed by the Engineer-in-Charge. |
| 37 | [c] All the safety measures including ARDs shall be ensured for serviceable condition round the clock and nothing extra shall be paid on these accounts.[d] The rate quoted shall be deemed to be inclusive of testing of each lift by Licensed Lift Inspector of Government of Andhra Pradesh twice in a year for worthiness of the Lift in respect of safety. Certificate issued by the Licensed Lift Inspector shall be submitted to the Engineer-in-Charge and a copy of Certificate shall be displayed in all Lift Cabins as directed[e]Emergency Light and necessary tools shall be available in a tool box in the shift for smooth functioning of lifts. |
| 38 | [f]Conveyance and communication system like mobile phone etc. shall be provided by the contractor to all Lift Mechanics and Helpers.[g]The contractor shall abide by the latest Labour Rules and Minimum Wages Act.[h] Wages paid by the contractor to the persons employed shall not be less than the minimum wages fixed by State / Central Government from time to time whichever is higher.[i] The contractor is responsible for making subscription towards Insurance, EPF, ESI,Labour Welfare Cess etc., as applicable and shall pay Gratuity, Bonus etc to the Workmen as per existing Labour Rules / Acts / Regulations and rate quoted shall be deemed to be included for the same. |
| 39 | [j] The contractor shall provide the workmen with Dark Blue Colour Uniform [Formal Pant & T-Shirt] with labels showing / printed i.e. \"Name of the Firm and Designation\" on Front and \"GE [U-II][V] on theback of the T-Shirt along with protective clothing / gear. The contractor shall also provide shoes to the workers and no person shall be allowed to enter the work site without wearing shoes.[k] The contractor shall be responsible for all Accidents / Injuries happening to the workmen. Any accident causing Minor / Fatal Injury, Partial Disability due to any untoward incident or non-adherence to Safety and IE Regulations or fault in maintaining of Lifts System / Safety Mechanism or on account of any mishandling / wrong operation / lack of knowledge of safety precautions or on account of any circumstances beyond his/their control, the contractor shall be solely responsible for settling all claims of compensation to the deceased, failing which department will have a right to recover any sum indicated / claimed by Labour Commissioner / Court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Contractor shall provide first aid boxes to meet any emergency situations. |
| 40 | [l] Fortnight, Quarterly maintenance registers shall be maintained and signed by the site engineer and contractor.[m] Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engr -in-Charge.[Notes for item No. 1 to 1.4 and 2.1 to 2.3]: The Bidder shall upload a Memorandum of Understanding (MoU obtained from OEM of Lift)alongwith Valid Product Approval letter of the OEM of the lift by MES (i.e E-in-C’s Branch / any Command HQs/ADG, for the Design, Supply, Installation, Testing, Commissioning, and future maintenance of the lift. The MoU and Valid Product Approval letter from the OEM are required to be uploaded online alongwith Technical Bid, failing which the bid will be summarily rejected and the Financial Bid shall not be opened. No representation or correspondence in this regard shall be entertained. |
| 41 | Conduit for PA system |
| 42 | Item No08 : M & L TV socket outlet suitable for co axialcable one module complete all as specified and directed by engg-in-charge. |
| 43 | Water cooler |
| 44 | Item No09 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volts to 250 Volts with output voltage stabilized at 230 Volts with accuracy of ± 2.5% and of capacity 2 KVA complete with alla auxillaries required for fully fintional, all as specified. |
| 45 | External Water supply |
| 46 | Item No10 : Supply, laying, jointing and testing of ductile iron pressure pipe with socket & spigot ends having ISI stamping marking confirming to IS:8329/2000 in standard length of 5.50 - 6.00 meter of classification K-7 suitable for and including push on rubber tyton (gasket D-jointing) with cement mortar lining in the pipes having 100 mm bore, including aligning the pipes inside trench as per IS:12288/1987 and testing the joints with required water pressure complete all as specified & directed. Note: (i) Cutting of pipe shall be measured and paid for separately (ii) Excavation earth works shall be measured and paid for separately. |
| 47 | Item No11 : M & L for Ductille iron fitting upto 100 mm dia for Bends,Tee pieces single branch. \"Y\" junction, double branch, crosscollars, caps and plugs, (all sockets or socket and spigot) complete all as specified and directed. |
| 48 | Item No12 : M & L for construction of brick masonry valves pits of the following internal dimension complete with 3.15 mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC work complete. |
| 49 | (a) 900 mm x 900 mm x 900 mm |
| 50 | (a) 900 mm x 900 mm x 900 mm |
| 51 | Refrigeration |
| 52 | Item No13 : Supply and fix refrigerator, electric driven (single phase), capacity upto to 195 Litres BEE 5 star rated complete all as specified and directed. |
| 53 | Item No14 : Supply and installation of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA with digital display and smart control. Complete with all accessories required for sully funtional pluc top etc asspecified and directed |
| 54 | External Electric supply |
| 55 | Item No15 : Supply and erecting GI Octogonal type pole size top dia 70 mm bottom dia 135mm thicness 3mm base plate 220x220mm base platethicness 12 mm foundation bolt m16x650x4 mm (7mtr long) including foundation nut bolt as per manufacture recommedation and GI Bracket single arm for fixing of street lightcomplete all as specified and directed. |
| 56 | Item No16 : Supply and fixing street light sintex box of size 300 mm x 200 mm x 105 mm, made out of FRP sheet with weather proof hinged door including self locking arrangement, out door type weather and vermin proof complete comprising of insulated / high quality PVC sleeves aluminium bus bar of capacity 63 Amps 04 Nos (three phase RBY and black for neutral) with and including 6 Apms MCB single pole, single phase 230 volts, including 25 x 3 mm flat iron mounted on insulators, having arrangement of connecting incoming and outgoing cables complete and all as specified and directed. NOTE:- 40mm dia elbow from coping to GI pipe shall be deemed inclusive in this quoted rate. |
| 57 | Item No16 : Supply & fixingof Nature switch Panel fixing for street light switch of wall/pole mountablePVCenclosure conforming to IP 65 consisting of Nature switch smart SPD.Isolater,MCB ddrive for loading , and terminal blocks the enclosure comes complete with mounting brackets 16 amp 5 KW, three Phase - contactor rating 16/63 A - 01 No, MCB TPN, 01 No and MCB DP, 240volts 16 Amp 01 No Make :MS flat clamps, nuts, bolts and washers complete all as specified and directed. |
| 58 | Item No17 : M & L for Earthingcomplete with galvanized earth plate electrode60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground levelconnected to GI strip 32 x 6mm as earth lead by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover , charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 40mm dia GI pipe light grade for protection of GI strip, wire mesh andconnected to earth point including testing on all as specified and shown in electric plate No 3 of SSR Part I. |
| 59 | Item No18 : M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron Wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steelconnected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) |
| 60 | type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle 8mm dia, plastering 15mm thick CM (1:6) externally upto 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test |
| 61 | Results on a 3.0mm thick painted M.S. earth pit marking Plate (200mm x 100mm) duly welded with a 450mm long 10mm dia round M.S. rod, fixed with the earth pit chamber by grouting complete including taking out old unserviceable earthing system including demolishing with old earth pit chambers and removing of debris from the site with levelling the ground all as specified an directed. |
| 62 | Item No19 : Supply, fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500mm x 1500mm x 400mm (over all dimension) made out of 3.00 mm thick CRCA sheet duly supported with MS angle iron of size 40x40x5mm vertical frame and legs with mild steel flat iron 25x5 mm in horizontal sides of the frame with front and back side openable, single hinged door/shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incoming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories complete all as specified and directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (Location : Main LT Panel Near Prop Transformer) |
| 63 | INCOMMING(a) Copper busbar of 1000 amps rated capacity wrapped with PVC sleeves with proper colour code and provision of holes with copper nuts, bolts & washers for cable connections including insulators with nuts & bolts at both ends - 04 nos(b) ACB, 4 pole, 415 Volts, microprocessor release type, manual draw out, 630 Amps with breaking breaking capacity 36 KA including all fixing accessories - 01 No. |
| 64 | (c) LED indicator lamp (RYB) with fuse holder 230 volts, AC -01 set (set of 3) (d) Digital Ammeter of range (0-300) Amps, flush mounting type of size 100mm x 100mm (4”x4”) square dial with CT’s of ratio 300/5 and selector switch – 01 set.(e) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No. |
| 65 | OUTGOING(a) MCCB, 4 pole, 415 Volts, adjustable type, 250 Amps with breaking breaking capacity 36 KA, Magnetic and thermal adjustable, Ics = 75 % Icu including all fixing accessories - 02 No. (1 Spare)(b) MCCB, 4 pole, 415 Volts, adjustable type, 160 Amps with breaking breaking capacity 36 KA, Magnetic and thermal adjustable, Ics = 75 % Icu including all fixing accessories - 02 No. |
| 66 | (c) MCCB, 4 pole, 415 Volts, adjustable type, 63 Amps with breaking breaking capacity 36 KA, Magnetic and thermal adjustable, Ics = 100 % Icu including all fixing accessories - 01 No.(d) MCB TPN 32 Amps 10 KA, C-series - 02 Nos(e) Multifunctional Digital type timer Switch 240 volts AC Single Phase - 01 No(f) Multifunctional Digital type timer Switch 240 volts AC Single Phase - 01 No |
| 67 | (g) Power contactor 32 amps 3 Pole 415 Volts AC - 01 No (h)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm x 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 68 | Item No20 : Supply, fabrication, installation and testing of semi concealed type LT wall mounted panel indoor type factory made CPRI Approved, water and vermin proof protection of size 1000mm x 1000mm x 300mm (over all dimension) made out of 2.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 25 x 25 x 5mm frame with front openable, single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces and connections of all outgoing / incommingcableinclusive of necessary fixing clamp as required including the following fitment accessories all complete as specified and as directed. |
| 69 | INCOMMING(a) Copper busbar of 600 amps rated capacity wrapped with PVC sleeves with proper colour code and provision of holes with copper nuts, bolts & washers for cable connections including insulators with nuts & bolts at both ends - 04 nos(b) MCCB, 4 pole, 415 Volts, adjustable type, 250 Amps with breaking breaking capacity 36 KA, Magnetic and thermal adjustable, Ics = 75 % Icu including all fixing accessories - 01 No. |
| 70 | (c) LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) (d) Digital Ammeter of range (0-200) Amps, flush mounting type of size 100mm x 100mm (4”x4”) square dial with CT’s of ratio 300/5 and selector switch – 01 set. (e) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No. |
| 71 | OUTGOING(a) MCCB, 4 pole, 415 Volts, adjustable type, 63 Amps with breaking breaking capacity 36 KA including all fixing accessories - 05 No. (1 Spare)(b) MCB TPN 32 Amps 10 KA, C-series - 02 Nos(c)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm x 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. |
| 72 | Shadowless lamp |
| 73 | Item No21 : Supply and fix Shadow less light fitting complete with emergency power unit & battery back up for min 30 minutes (3 KVA), having dome of 810 mm dia, fully counter balanced and fixed on suspension rod capable of having axial rotation of 360 degree. The unit to be suitable for operation on 230 V, single phase 50 cycles mains supply. lux level 40000 Light should be adjustable type, having technical specification should be as follow1.source: LED, cold light,CRI (Ra) ≥ 90,2.Colour temperature: 4000–5000 K, 3.focal distance: 0.8–1.2 m working distance(adjustable type) as per NHSRC specifications.4.Compliance with electrical & medical device safety standards (IEC 60601-1 for safety & compatibility, ISO 13485 certified manufacturer) 5.Brightness / intensity control (step adjustment or stepless), ability to focus/adjust light field, adjustable arms (radial, angular, axial movements) |
| 74 | 1.source: LED, cold light,CRI (Ra) ≥ 90,2.Colour temperature: 4000–5000 K, 3.focal distance: 0.8–1.2 m working distance(adjustable type) as per NHSRC specifications.4.Compliance with electrical & medical device safety standards (IEC 60601-1 for safety & compatibility, ISO 13485 certified manufacturer) 5.Brightness / intensity control (step adjustment or stepless), ability to focus/adjust light field, adjustable arms (radial, angular, axial movements) |
| 75 | Item No22 : Supply and fix Shadow less light fitting complete with emergency power unit & battery back up for min 30 minutes (3 KVA), having dome of 810 mm dia, fully counter balanced and fixed on suspension rod capable of having axial rotation of 360 degree. The unit to be suitable for operation on 230 V, single phase 50 cycles mains supply. lux level 40000 Light should be adjustable type, having technical specification should be as follow |
| 76 | 1.source: LED, cold light,CRI (Ra) ≥ 90,2.Colour temperature: 4000–5000 K, 3.focal distance: 0.8–1.2 m working distance(adjustable type) as per NHSRC specifications. 4.Compliance with electrical & medical device safety standards (IEC 60601-1 for safety & compatibility, ISO 13485 certified manufacturer) 5.Brightness / intensity control (step adjustment or stepless), ability to focus/adjust light field, adjustable arms (radial, angular, axial movements)6. should be mobile type and can be easily movable as per need. |
| 77 | Fire detector system/ alarm Sysem) |
| 78 | Item No23 : S & F for wiring fire alarm systems with cable of 2 core, multistranded annealed of size 1.5 sqmm armoured red colour FRLS PVC insulated copper conductor,in surface / recessed as required in MS conduit of 25mm dia, Complete with saddles and GI perforated tray of suitable size accessories required for fitting cablesfor fully functional as specified directed. |
| 79 | FIRE FIGHTING |
| 80 | Item No24 : Supply and fix MS cabinate (Approx 750 mm x600mm x450 mm ) to enclose firebrigade inletconnection fabricate from 16 gauge sheet with full front glass door and locking arrangement . |
| 81 | Item No25 : Providing and fixing resilient rubber neoprene lined single arch vibration eliminators suitable for raw water upto 450C temperature working pressure 7kg and test pressure 14 kg/ cm2. |
| 82 | (a) 80 mm bore |
| 83 | (b) 100 mm bore |
| 84 | Item No26 : M&L for construction of brick massonry valve pit of internal size 900 mm x 900mm x 900 mm including necessary excavation and earth work in soft/loose soil , brick work , plastering, white wash , PCC coping, MS frame mde out of angle iron of size 40 mmx 40 mmx 6 mm , MS sheet cover of 3 mm thick fixed to angle ireon frame by means of hinges welded to frame and painting with 2 coats of synhetic ennameled paint over a coat of red oxide primer on steel surfaces and gruoting the frame in PCC 1:2:4 type B1 including handle and locking arrangement with one number 50 mm dia brass pad lock, complete all as specified and directed by Engineer in charge. NOTE :-1.Brick wall shall be 23 cm thick built in cement mortor 1:4 2. Internal plaster shall be 15 mm thick in cement mortor 1:4 and external plaster up to 450 mm from top shall be 20 mm thick in CM. |
| 85 | Item No27 : Supply install,testing and commissioning LT panelindoor type, dust and vermin proof totally enclosed plateform mounted factory made (Protection class IP-54) double shutter gears front and rear frame work and 16 SWG thick MS sheet duly painted with powder coated overtwo coats of redoxide primer and made of40 x 40 x 6 mm thick angle iron frame all as specfified including necessay foundation.bolt grouted in PCC 1:2:4 for mounting the pannel suitable for 415 Volts, 50 C/s 3 phase and nutral system and shall be completed with 300 amps capacity Copper bus bar with bus bar chamber,internal wiring with suitable size of PVC insulated copper cable and copper lugs comprising of following accessories:- |
| 86 | (A)Incomming(i) MCCB, 4 pole, 160 Amp, thermal megnatic release adjustable type , 35KA-01 No (ii) Digital type Ammeter 0-200 Amps -with CTs- Set of Three-01 Nos(iii) Digital type Voltmeter 0-500 volts with selector switch -01 No (iv)Indicating lamp-01 setof three(B)Outgoing(i) MCCB, 3 pole, 100 Amp, thermal megnatic release adjustable type type, 25KA-01 No(ii) MCCB, 3 pole, 32 Amp, thermal megnatic release adjustable type, 25KA-01 No |
| 87 | (iii) Digital type Ammeter 0-200 Amps -with CTs- Set of Three-02 Nos (iv) Star delta starter 50 H.P. -01 No. (v) Star delata starter 20 H.P -01 No (vi) Battery Charger 12 Volts DC.-01 Nos (vii) LED Indicating Lamp -set of Three ( 02 Nos) ( viii) Auto Manual switch -03 Noswith control wiring 2.5 Sqmm 3 core copper multistranded FRLS wire for pressure switch for auto operation of jockey pump,electric driven pump and Diesel pump. |
| 88 | Item No28 : Supply install,testing and commissioning star delta starter of capacity 20 HPcomparising of single phase prevantor, TNC sitch for auto manual operation and fixing arrangement on wall. |
| 89 | Item No29 : Supply only of fire exingusiser ISI marked CO2 type fire Existinguiser 4.5 KG capacity confirming to IS : 15683:2006 (old IS : 2878) made from seamless cylinder confirming to IS : 7285 duly aproved by chief controller of explosive , Nagpur fitted with ISI Marked Controlled valve confirming to IS 3224, hight pressure 1mtr long discharge hose and hom complete with intitail gas charged with carrying handle and wall mounting bracket, sutaible for operating between 30 degree centngrated to + 55 centigarte , Fire Rating Class-138. |
| 90 | Item No30 : Supply only stored pressure fire exinguisher ISI Marked Powder type Fire Exingusher 4 KG Capacity suitable for Class A,B, C fir consisting with discharge hose and nosle of welded cylinder , squeeze liver discharge valve fitted with pressure indicating guage, internal discharge tube, discharge nosle, suspension bracket confirming to IS: 15683: 2016 duly charged with ISI Maked Ammonium phosphate base ABC powder confirming to IS : 14609and pressized with Nitrogen Gas , suitable for opersting between 30 degree centigate to +55 digree centrigrate, Fire Rating Class- 1A & 13B. |
| 91 | Item No31 : Supply of fire bucket iron red colour 10 L capacity for dry sand stored type ISI Marked IS : 2546 : 2006, complete all as specified and as directed. |
| 92 | Item No32 : Supply only of Fire Exitingusher Mechanical Foam type ISI Marked Foam (AFFF) type fire exinguisher 9 L capacity fitted with forged brass squeeze liver discharge valve confirming to IS :15683 : 2006complete with intial refile consisting of of ISI Marked CO Gas Cargtridge of 60 Gms Capacity confirming to IS 4947 and ISI Marked AFFF confirming to IS 4989 suitable for operating between + 50 degree centrigrate, fir rating Class 3A an 34. |
| 93 | Medical Gas Pipe line |
| 94 | Item No33 : Design, supply, install, testing and commissioning of copper pipes (degassed, medical - grade), Brazing with silver alloy (no flux, per standards) medicinal gas pipe line network with connected valves, Pressure regulators and filters, necessary pumps / motors and connected items, Medicinal gases comprise of Oxygen, suction and compressed air etc. Pipe line network is to be laid in treatment room, injection room, recovery room and minor OT of trauma care centre in the scale of 1 per room and connected them to the manifold room to previded sufficient medicinal gas supply. |
| 95 | All these pipes are to be different colours conforming to laid down standard mounting to wall. outlet wall mounted fitting to be provided to each outlet including adopter. flow meter, antistatic tubing up to bed. system, terminal units different connectors for each gas to prevent mix-ups as per ISO 7396-1 (Pipline systems) and all connected necessary items for the proposed location. The designing and installation of medicinal gas pipeline system shall be as per relavant IS specification and best practices for Hospitals. |
| 96 | Any other Technical items which is required for proper/efficient installation of medicinal gas supply system as per standared norms and as specified in tender shall deemed to included in the quoted rates. Design of medicinal gas pipeline system to be submitted to the dept duly vetted by MH authority after 30 days of acceptance of the contract. Testing after installation should be done as per relevant IS by MH Authority. |
| 97 | Central AC Plant |
| 98 | Item No34 : Design, Vetting, supply, installation, testing & commissioning of Central air conditioning plant with Water cooled Chiller Plant of reference design Capacity 130 TR (03 Nos of equal capacity), AHUS, FCUS, Electric Hot water Generator set, Expansion tank for chilled water and Hot water, Humidifiers, water pump sets (min 2W+1S) of suitable type and capacity for chilled water condenser, hot water generator, FRP Induced Draught cooling towers (1W+15), ducting and Insulation for duct and pipings. Voltage stablizer of required capacity (min 200KVA) natural oil cooled, Electrical Panels and cables of suitable size for Chiller AHU Panels, Hot water Generator, any type of Pumps and any other electrical equipments shall deemed to be included in the quoted rates. Cable tray, Water piping for condenser, chiller hot water generator etc with strainer, all typ |
| 99 | es of valves and vents, Piping Accessories, Temperature guage, Pressure guage, Dampers/fire proof damper, diffusers and grills, Air curtain, earthing, ducting sheet, associated civil work, plumbing work and electrical work shall demed to be included in the quoted rate. The designing and installation of Central AC Plant shall be as per ASHRAE/ISHRAE standards, relavant IS specification and best practices for auditorium bldgs. Any other Technical items which is required for proper/efficient installation of HVAC system as per standard norms and as specified in tender shall deemed to be included in the quoted rates. Design of Central AC Plant to be submitted to the dept duly vetted by IIT/NIT/any govt engg college after 30 days of acceptance of the contract. |
| 100 | Note:1-(I) Design of energy efficient central air conditioning plant based on inside & outside conditions inside conditions as per given data sheet attached in PS. The design shall meet relevant ASHRAE/ISHRAE norms and code requirements and should as per latest IS practices. It should included the followings:-(a) Data based heat load calculations for all weather seasons(b) Duct drawing showing different sizes of ducts air flow details, incl fire dampers and air dampers.(c) Chiller water piping / condenser water piping etc drawings including valves, vents,strainer, drains etc. |
| 101 | (d) Layout schematic line diagram of LT control panel suitable for the plant showing all the details such as main incoming, outgoing and their type, capacities, qty, alongwith connected measuring instrument/meters, indication lamp, starters, MCB/MCCB/ isolator literature of various components.(e) Specification/description of equpeiment and other materials/items with technical literature of various components.(f) Line plan of plant AHU showing various eqpts/items with dimensions of various qpts/items with specific working clearances between eqpts to eqpts and from walls, after due consideration of existing doors and windows. |
| 102 | (g) Schedule of item/description of equipment of all items with accounting unit. Qty and particular specification etc.(h) Full description of item/eqpt of schedule as per recommended brands/makes in the Tender.(i) Inside design conditions are required to be maintained irrespective of minor variations in outside conditions throughout the year as per desired conditions as per PS data sheet.(j) Contractor will submit detailed Qty with line plan which shows the all type of valves, pumps, pipe lines, Chiller AHU, Cooling Tower, Expansion tank etc.Note2:(a) Contractor should submit 2 Nos CD showing detailed design with description/specfification complete alongwith heat load calculation (For summer, winter & monsoon design, drawings, bill of quantities and four Nos hard copies.(b) Outside design conditons at Jabalpur can be obtained from concerned metrological authorities. |
| 103 | (c) Contractor will develop the soft copy of all the drawings required for the work on the basis of hard copy/line plan of the project.(d) Design folder duly incorporating above design details, layout plans and specifications incl BOQ of the items shall be submitted by the contractor duly bound 3 hard copies and CDs after vetting from HT/NIT/ any Govt Engineering College for the acceptance by the Rep of accepting officer before execution.(e) The work of Air conditoning shall be carried out by a specialist agency having past experience.(f) Noise level (Sound pressure) should not exceed the permissible limts.(g) Testing includes phase-1 24 Hrs continuous after completing the main work and phase-II 72 Hrs continuous for all three seasons after isssuing completion of Phase- I by the IEM(h) Any modification/alteration done for ducting and piping in the building, the Contractor shall make good the damage done for the same. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |