| Sl. No. | Item Description |
| 1 | Dismantling of AC corrugated sheets of any thickness as in roofs including ridge complete all as specified and as directed. |
| 2 | Dismantling timber scantlings 40 sq. cm and over in section, in any positioncomplete all as specified and as directed. |
| 3 | Dismantling framed trusses exc 10m but not exc 15mcomplete all as specified and as directed. |
| 4 | Demolition of brick /stone masonry built in cement mortar of any description complete all as specified and as directed. |
| 5 | Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets any thickness complete all as specified and as directed. |
| 6 | Demolition of reinforced cement concrete of any description not otherwise specifically provided for (reiforcement cut to facilitate demolition) completecomplete all as specified and as directed. |
| 7 | S&F prepainted galvalume aluminium zinc coating G.I based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering /cladding to wall, fixed with self taping screwscomplete all as specified and as directed. |
| 8 | S&F prepainted galvalume aluminium zinc coating G.I based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa as in roof covering /cladding to wall, fixed with self taping screws as in ridge coverin complete all as specified and as directed. |
| 9 | S&F `Rooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etcconforming to Fe 410 W (gde E-250) complete all as specified and as directed. |
| 10 | S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachementconforming to Fe 410 W (gde E-250) complete all as specified and as directed. |
| 11 | S&F mild steel purpose made bolts of diameter of neck exc 12 mm but n.exc 20 mmwith hexagonal or square head one end and screwed the other or screwed both ends, each screwed ends to be fitted with washers and one hexagonal or sqare n.exc 30 cm longcomplete all as specified and as directed. |
| 12 | M&L for reinforced cement concrete type B1 (1:2:4) using 20 mm gradedas in beams, cantilevers, bressummers, lintls over 1.5 m spancomplete all as specified and as directed. |
| 13 | M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup ports, overhangs, etc also spays between floors and beams etc complete all as specified and as directed. |
| 14 | M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking and bending spirally for hopping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90mm dia) or securing with clipscomplete all as specified and as directed. |
| 15 | All as Per Srl Item No 14 but 5 to 10 mm dia as in stirrups, spacer etccomplete all as specified and as directed. |
| 16 | M&L for brickwork with sub class \"B\" bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6complete all as specified and as directed. |
| 17 | Brick work with sub class ‘B’ bricks ,straight or curved on plan exc 6 m mean radius and built in cement mortar1:6 complete , but except bricks , i.e using serviceable bricks obtained from demolition complete all as specified and as directed. |
| 18 | Suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured varient E-board (classic), ISI marked, conforming to IS:14982-2000 over and including GI snap grid frame workfor false ceiling, grid size605 x 605 mm with GI angle of size 24x24mm, main runner ‘T’ of size 24x38mm, secondary runner ‘T’ of size 24x28mm with 6mm GI wire with butterfly clips for leveling, fastners, supports, plugs to walls/joists etc all as per manufacturer’s Instructions,including making holes, cutting chasis and making good existing walls in cement mortar 1:3 or PCC 1:2:4 type B1, complete all as specified anddirected. Note : All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm including dismantling/taking down existing snap gridcomplete all as specified and as directed. |
| 19 | S&F sheet glass 3mm thick ordinary quality and glazing with oil putty in square not exc 0.5 Sqm each pane complete all as specified and as directed. |
| 20 | S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (both type) 300mm longh, and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified and as directed. |
| 21 | Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel springs, fixed in floor with over all length of cover plate 150mm complete all as specified and as directed. |
| 22 | M & L for helical door spring complete all as specified and as directed. |
| 23 | PCC 1:3:6type C - 1 (using 20 mm graded crushed stone aggregate) as in back fillingof chowkats and bed blocks for hold fasts etccomplete all as specified and as directed.. |
| 24 | 2nd Class hard wood 35mm thickfactory made glazed and skelton shutters open rebated and prepared to receive glass , gauze,etc (without sash bars) edges of framing plain , chamferedor rounded. Fitted with cut and mitred beads for securing wiremeshsupplied and fitted to chowkatscomplete all as specified and as directed. |
| 25 | Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with 2nd class soft wooden beadings complete all as specified and as directed. |
| 26 | 75 mm thick,plain cement concrete1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection etc, finishingsurface even and smooth without using extra cement including making joints with bitumastic filling in proportion of bitumen and sand 1:3 by weightcomplete all as specified and as directed.(Note : The concrete shall be laid at a stretch n.exc 3.0 m in length and every turning/ corners. |
| 27 | M&L for two coats synthetic enamel paint over a coat of red oxide primer on newly steel surfacescomplete all as specified and as directed. |
| 28 | Preparation of old painted steel surface of any description, over 10 cm in width or girth not other wise described, and applying one coat of synthetic enamel paintcomplete all as specified and as directed. |
| 29 | Preparation of old distemperedsurfaces and applying one coat of oilemulsion distemper on wallscomplete all as specified and as directed. |
| 30 | Non - skid ceramic coloured jointless tile400mm x 400mm x 7mm thick as in floors laid over and including 15 mm thick screed bed or bedding layer of cement mortar 1:4, set and jointed in neat cement slurry and pointed incoloured cement to match the colour of tilescomplete all as specified and as directed. |
| 31 | Non - skid ceramic colouredjointlesstiles 400mm x 400mm x 7 mm thickon vertical surfaces such as skirting /dado etc bedded & jointed in neat cement slurry over and including 10 mm thickbacking coat of cement mortar 1:4and pointed in white or coloured cement to match the colour of tilescomplete all as specified and as directed. |
| 32 | M & L forglazed/anti-skid vitrified dark shade tiles 10mmthick (square/rectangular polished area of each tiles n.exc 0.36 sqmregular useas in floor set and jointed in neat cement slurry and pointed in coloured cement to match the shade over and including 15 mm thick screed bed in CM 1 :6complete all as specified and as directed. |
| 33 | M & L forglazed/anti-skid vitrified dark shade tiles 10mmthick (square/rectangular polished area of each tiles n.exc 0.36 sqmregular useas in vertical surface set and jointed in neat cement slurry and pointed in coloured cement to match the shade as per manufacturer instructions over rendering 10mm thick on fair faces of brickwork or concrete surfaces with CM 1:4complete all as specified and as directed. |
| 34 | Angle valve 15 mm fancy type, chromium plated15 mm of cast copper alloy, screwed down for iron pipe ,fixed in repairscompletecomplete all as specified and as directed. |
| 35 | Taking down chowkats or frameswith shutters (without taking off shutter from the frames) exceeding1.5 sqm & not exceeding4 sqm eachcomplete all as specified and as directed. |
| 36 | Pressed steel frames of size125mm x 60mmfor doors with one or more rebatesincludingnecessary fixing lugs, keys , hinges lock, lock strike plate etc.made out of 1.25mm thick MS sheet including one shop coat of red oxide zinc chrome primer etccomplete all as specified and as directed. |
| 37 | M&L 35 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with both face is covered with deco rative face veneer with lipping/frame to matchcomplete all as specified and as directed.. |
| 38 | Taking downchowkats or frames with shutters (without taking off shutter from the frames) n.exc 1.50 Sqm eachcomplete all as specified and as directed. |
| 39 | Solid PVC door/cup board frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling and fixing in openingcomplete all as specified and as directed. |
| 40 | Factory made solid panel PVC door/cup board shutter 30mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails.M.S frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement or stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail.Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, suippling and fixing in the frame at site as per specification in SSR Part-I.complete all as specified and as directed. |
| 41 | Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements,complete all as specified and as directed. |
| 42 | Butt Hinges medium weight cold rolled mild steel of size 100 mmcomplete all as specified and as directed. |
| 43 | 150 mm size mild aluminium handles cast type anodisedcomplete all as specified and as directed. |
| 44 | 150mm Aluminium, anodised, barrel tower bolts of extruded section and fixedcomplete all as specified and as directed. |
| 45 | 75 mm thick Cement concrete type B2, 1:2:4 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing finishing the surface even and smooth complete all as specified and as directed. |
| 46 | Capillary rise treatment of walls, Consumption base coat: 0.3 Kg/Sqm, Second and Third coat : Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent, Consumption top coat: 3 Kg/Sqm, System requirements : density : 2.00 Kg/Ltr, Compressive strength: 0.5 N/Sqmm. complete all as specified and as directed. |
| 47 | Glass fibre reinforced modified cementitious coating system before the final coat of(or equivalent) in Sunken treatemen. Base coat :(or equivalent),Consumption base coat : 0.3 Kg/Sqm, Reinforcement : Glass fiber, Second and Third coat :(or equivalent), Consumption top coat: 3 Kg/Sqm, System requirements : density: 2.00 Kg/Ltr, Compressive strength : 0.5 N/Sqmm. (i) Wall penetration through the RCC slab must be sealed using Berger HS Repir (or equivalent). (ii) Intersection of base slab with wall must be provided with a 50 mm fillet using Berger HS Latex plus(or equivalent) modified mortar with a bonding coat of Berger HS Latexplus (or equivalent) modified cement slurry upto 1.5 Mtr. (iii) All depressions, unevenness, surface honeycombing shall be repaired using Berger HS Latex plus(or equivalent) modified polymer mortar with a bonding coat of Berger HS latex plus (or equivalent) modified cement slurry, including cleaning ofRCCsurface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc |
| 48 | M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 with water proofing compound tobe finished even and smooth without using extra cement completeall as specified and as directed (WPC to be measured separately) |
| 49 | Supply onlyIntegral water proofing compound liquid complete all as specified and as directed. |
| 50 | S&F 32 mm dia High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in as spout pipes to pour out residual water out from the treated area complete all as specified and as directed. |
| 51 | M&L for hard core, of broken bricks broken to gauge n exc 63mm for laying sub base of thickness 150mmcomplete all as specified and as directed. |
| 52 | M&L Cementconcrete type D-2 1:4:8 (40mm graded crushed stone aggregate) in foundations, filling and mass concrete in sub base complete all as specified and as directed. |
| 53 | M&L for 25mm thick PCC (1:2:4) type B1 with 20mm graded aggregate for laying floor tiles complete all as specified and as directed. |
| 54 | M&L for non skid coloured Ceramic tiles 8 to 10 mm thick in light shade (square/ rectangular) polished, area of each tiles exc 0.11 sqm but not exceeding 0.18 sqm, in floors/Skirting etc. set, jointed and pointed with Berger HS tile adhesive anti slip white @1.2kg/sqm thickness upto 8 to 10mm (or equivalent) and epoxy material for sealing of tile joints with Berger HS Epoxy tile grout(or equivalent) to the floor of toilets and bathroom complete all as specified and as directed. |
| 55 | Demolition of cement concrete in and paving (un reinforced)exc. 15 cm. thickness, below or above ground level, including removal of waste from defence land and dumping at a place as specified by civil authoritiescomplete all as specified and as directed. |
| 56 | Vitreous china squatting pan \"Orissa\" pattern long pan size 580 x440 mm white withintegral foot rests (excluding cistern and flush pipe), fixed in repair, complete all as specified and as directed. |
| 57 | Vitreous china wash down water closet (pedestal pattern) colouredcomplete, including connection to drain pipe and to flushing pipe antisyphonage pipe etc, including seat cover fixed in repair, complete all as specified and as directed. |
| 58 | S& F low level flushing cistern PVC valveles ,syphonic action type flushing cisternwhite with inlet valve,float and handle including bracket etccomplete all as specified and as directed. |
| 59 | S&F Vitreous china wash basin white flat back size 580x450 mm excluding taps waste chain and plug and porcelain stopper but including brackets, fixed in repair,complete all as specified and as directed. |
| 60 | S&F PVC (SWR) P trap 110mm bore complete all as specified and as directed. |
| 61 | S& F in repair chromium plated towel rail 20mm dia and 60 Cm long fixed to wallcomplete all as specified and as directed. |
| 62 | PVC 32mm dia waste pipe with CP coupling,complete all as specified and as directed. |
| 63 | Taking up or down 15mm bore steel tubing and connection including cleaning for re-fixing or removal to storecomplete all as specified and as directed. |
| 64 | Taking up or down 20mm bore steel tubing and connection including cleaning for re-fixing or removal to storecomplete all as specified and as directed. |
| 65 | S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors. complete all as specified and as directed. |
| 66 | S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore dia 20 mm, complete all as specified and as directed. |
| 67 | Refixingold galvanisedsteel tubing of20 mmboreand connections in new or old position with all fittings fixed complete to walls ,ceiling, or laid infloors etc. complete all as specified and as directed. |
| 68 | Refixing old galvanisedsteel tubing of15 mmboreand connections in new or old position with all fittings fixed complete to walls ,ceiling, or laid infloors etc. complete all as specified and as directed. |
| 69 | S & F 15 mm bore chromium plated bib taps fancy type, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. |
| 70 | PVC (SWR)floor trap, plain with CP grating including jointing with solvent cement of 75mm outlet diacomplete all as specified and as directed. |
| 71 | Fancy type, chromium plated angle valve 15 mm of cast copper alloy with crutch or butter fly handle, screwed down for iron pipe ,fixed in repairs complete all as specified and as directed. |
| 72 | Pillar taps 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or with out lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for iron pipe fixed in repairs complete all as specified and as directed. |
| 73 | Dismantling water tanks of any description1000 Ltrs capacitycomplete all as specified and as directed. |
| 74 | Rotational moulded polyethlene water storage tanks , triple layered, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of Capacity 1000 litres including over flow , drain out pipe and all accessoriescomplete all as specified and as directed. |
| 75 | Ball brass valve, high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed to pipe20 mm bore fixed in repairs complete all as specified and as directed. |
| 76 | Taking down cement plasteron bricksor stone wall / ceiling decayed surfaces of concrete, roof projections or chajjas etc upto triple storey including racking out joints, hacking for key, scrubbing down with water etccomplete all as specified and as directed. |
| 77 | M&L Rendering 10mm thick in cement plaster 1:6 on fair faces of brick/concrete surfaces finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 78 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and as directed. |
| 79 | Rendering 5 mm thick onconcrete surfaces of ceilingsin cm 1:3finished even and smooth withoutusing extra cement complete all as specified and as directed. |
| 80 | Complete removal of existing treatment and applying 2 coats of oil bound distemper emulsioncomplete all as specified and as directed. |
| 81 | Preparation of new plaster surfaces of walls and applying two coats of oil emulsion distemper over 3mm wall care putty on the walls complete all as specified and as directed. |
| 82 | Material and labour for preparation of newly plastered wall surface and applying two coat of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance of approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio as per manufacture\"s instruction and all coats incl primer to be applied with fully automatic airlessspray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed.Make: Berger Paints Weathercoat Long Life Flexo / Nerolac Paints excel Total / Asian Paint Apex Ultima / J.K Maximo ultraNote :-(a) Work shall be done as per MoU between tenderer and manufacturer of paints and their authorized applicator complete all as specified and directed (b) The contractor shall upload MoU between tenderer and manufacturer of paints and their authorized applicator after conclude of tender and before place of Work Order Documents as mentioned in NIT.(c) The work pertaning to periodical services & water proofing shall be executed from authorized applicator through manufacturer of which the material i.e.paint, distemper, cement base paint, putty etc. is proposed to be used by the contractor and approved by GE. |
| 83 | Material & Labour for RCC chajja/fascia/parapet repair by using following steps :-(a) Removal of existing concrete along with loose damaged and cracked concrete/cover concrete from chajjas etc, exposing corroded steel reinforcements upto a depth of 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting to chipped concrete and reinforcement all as directed by Engineer-in-charge. Hard concrete shall not be removed. However if the rebar is corroded, concrete around it shall be removed.(b)Cleaning the surface of reinforcement bars from dust by using wire brushes and dry cloth and applying FOSROC Rebakleens RR- Rust Remover or equivalentusing small brush and allow to react it for 16-24 hrs. (c) Providing and applying two coats of Fosroc Nitozinc Primer - two component, zinc rich epoxy, anti-corrosive protective coating or equivalentby brushes to the exposed and cleaned rebars with an interval of 45minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours all as directed by Engr-in-Charge. |
| 84 | Material and labour for complete removal of existing treatment including fascias, cornices etc by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7\"/9\" to make the surface free from dust, loose paint and loose plaster to be completely removed by skilled labour and repair of external wall/Chajjas to be done with repair mortar to get even surface including preparation of old surface of wall/ceiling by filling cracks by Putty / crack fill paste of approved make and make good smoothen surface by sand paper and applying two coats of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology ,Excellent Dirt Pick up resistance of Berger Paints Ltd or equivalent of other approved make with low VOC less than 50 gram/ litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over one coat of acrylic water based exterior grade primer @ 0.9ltr(undiluted)/10 sq mtrs diluted with water in 1:1ratio as per manufacture\"s instruction and all coats incl primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI all as specified and directed.Allow 6-8 hrs to dry the surface in subsequent coats of paint and including necessary scaffolding at any height complete all as specified and directed Make: Berger Paints Weathercoat Long Life Flexo/ Nerolac Paints excel Total / Asian Paint Apex Ultima / J.K Maximo ultraNote :-(a) Work shall be done as per MoU between tenderer and manufacturer of paints and their authorized applicator complete all as specified and directed (b) The contractor shall upload MoU between tenderer and manufacturer of paints and their authorized applicator after conclude of tender and before place of Work Order Documents as mentioned in NIT.(c) The work pertaning to periodical services & water proofing shall be executed from authorized applicator through manufacturer of which the material i.e.paint, distemper, cement base paint, putty etc. is proposed to be used by the contractor and approved by GE. |
| 85 | Preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primercomplete all as specified and as directed. |
| 86 | Preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and as directed. |
| 87 | Shower rose of C.P. swival joint of size 125mm for fixing 15mm pipeincluding fixing to steel pipe or union fixed in repairscomplete all as specified and as directed. |
| 88 | PVC connections 15mm dia & 600mm long with PTMT nutscomplete all as specified and as directed. |
| 89 | Box type steel windows comprising of tubular frame and shutters made out of 1.25mm thick MS steel tube, factory made, with double side shutters wire gauged shutter and glass glazed shutter (wire and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150 mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to F1 frame work, including other fittings, hinges, handles tarred hold fasts PCC blocks etc all as shown on Drawing No CEPZ/TD-354/09 sheet 1/3 to 3/3 including taking down old steel window of any sizecomplete all as specified and as directed. |
| 90 | Looking mirror 1200X600 x 5mm beveled edge mirror of selected quality glass 5mm thick mounted on 6 mm thick AC building board or commercial ply and fixed to wooden plugs with CP brass screws and cup washers etc, fixed in repairs,complete all as specified and as directed. |
| 91 | Peg stay Cloth Hanger 30 to 60 cm long between Hangs, fixed in repairs complete all as specified and as directed. |
| 92 | Complete removal of existing roof treatment or roof tile and removing from site to a place outside defence land as specified by civil authorities and clean the surface of roof with water and remove dustcomplete all as specified and as directed. |
| 93 | M&L for a one component liquid ,solvent free ,cold applied , water-proofing membrane that is highly elastic and UV resistant with 10 years Warranty .ASTM D 6083-97a Waterproofing and heat reflecting system having following key performance properties:1.UV resistant ,prevent yellowing and weathering2.Highly elastic upto 350% and crack bridging3.Excellent adhesion on porous and non-porous substrates4. Tensile Strength >10 N/mm2 with GeoTextile fleece5. Soler Reflective Index (SRI) more then 109-111ASTM E1980-11System: First coat:Providing and applying primer over the prepared surface with a liquid water proofing primer specifically designedfor use on roofs.Coverage: 0.2kg/m2(with 50% dilution of water)Reinforcement: Geotextile 40 gsmSecond coat: Liquid water proofing compound designed to protect roof from water damage.Consumption: 0.5 kg/m2.Third coat: A one component liquid, solvent free, cold applied, water proofing membrane that is highly elastic and UV resistant.Consumption : 0.8 kg/m2.System buildup-1.5kg/sqm with geotextile of 40gsmFor accessible roof, tiles with screed/ adhesive may be fixed thereafter. |
| 94 | Cleaning of the exposed concrete slab and repairing the surface irregularities like cracks, potholes, and building joints as per manufacturers method statement using non sag polymer modified, cementitious material with styrene butadiene rubber latex based liquid mixed with CM 1:4 for waterproofing of the exposed surfaces complete all as specified and as directed.. |
| 95 | Providing cement concrete type B-0 1:2:4 (using 12.5 mm graded stone aggregate ) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges finished even and smooth without using extra cementcomplete all as specified and as directed. |
| 96 | Dismantling floor, hearth or wall tiling , terrazzo topping on wallsincluding cement mortar ,bedding (but no backing) removing serviceable tiles and rubbish off the premisescomplete all as specified and as directed. |
| 97 | M&L for Non Skid joint freeceramic coloured tiles 300 x 300 x 7 to 8 mm thickin floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4complete all as specified and as directed. |
| 98 | Glazed ceramic coloured tiles of size450X 300X 7mm thick as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4,complete all as specified and as directed. |
| 99 | S & Fixed in repairs Angle stop valve cast copper alloy, with fancy type chromium plated capstan head, screwed down, high pressure screwed both ends for 15 mm bore iron pipe or for unions and fixedcomplete all as specified and as directed. |
| 100 | PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to wallincluding fixing clampscomplete all as specified and as directed. |
| 101 | PVC (SWR) pipes 75 mm bore single socketed in any length in floors or trenchescomplete all as specified and as directed. |
| 102 | S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints laid in floors or trenches complete all as specified and as directed. |
| 103 | PVC (SWR) pipes 100 mm bore single socketed in any length with rubber ring joints fixed to wallincluding fixing clampscomplete all as specified and as directed. |
| 104 | PVC (SWR) bends any radius 75mm borecomplete all as specified and as directed. |
| 105 | PVC (SWR)junction single(single T) equal or unequal 75mm borecomplete all as specified and as directed. |
| 106 | PVC (SWR) bends any radius 110mm borecomplete all as specified and as directed. |
| 107 | PVC (SWR)junction single(single T) equal or unequal 110mm borecomplete all as specified and as directed. |
| 108 | Dismantling cast iron or reinforced concrete drain pipes of 100/75mm bore, fixed with walls and taking out of trenches, if requiredcomplete all as specified and as directed. |
| 109 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m depth, for foundation etc or for shafts, manholes, etc not exc 10.00sqm on plan and not exc 1.5m depth and getting out in any type of soil complete all as specified and as directed. |
| 110 | Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m depth and not exceeding 3m for foundation, manholes, etc., and getting out in any type of soil complete all as specified and as directed. |
| 111 | Returning filling in, including spreading, levelling watering and well ramming in layer not exc 25 cm thick complete all as specified and as directed. |
| 112 | Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 metre above the starting point,complete all as specified and as directed. |
| 113 | Demolition and breaking up drain pipes 200mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, completecomplete all as specified and as directed. |
| 114 | Demolition and breaking up drain pipes 150mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, completecomplete all as specified and as directed. |
| 115 | Concrete bed to drain pipes including packing under, and haunching againstthe sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate for 200mm dia bore pipes allas per SSR Part-I specifications,complete all as specified and as directed. |
| 116 | Concrete bed to drain pipes including packing under, and haunching againstthe sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregatefor 150mm dia bore pipes allas per SSR Part-I specifications,complete all as specified and as directed. |
| 117 | S & F 200 mm dia DWCPE (SN8) HDPE pipes laid in trenches on PCC bed incl jointing as per manufactures instructions and as directed. (Bending/ haunching and earthwork paid separately under respective items of schedule) complete all as specified and as directed. |
| 118 | S & F 150 mm dia DWCPE (SN8) HDPE pipes laid in trenches on PCC bed incl jointing as per manufactures instructions and as directed. (Bending/ haunching and earthwork paid separately under respective items of schedule) complete all as specified and as directed. |
| 119 | Cutting into existing manholes for connecting new drains (internal dia of pipe 200mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as requiredfor (100/150/200) pipe. complete all as specified and as directed. |
| 120 | Demolition of unreinforced cement concrete in ground floors & pavings not exceeding 15cm thicknes (below or above ground level)complete all as specified and as directed. |
| 121 | Demolition of cement concrete (unreinforced) in ground floors and paving any thickness (below or above ground level)complete all as specified and as directed. |
| 122 | Brick work with sub class\"B\" bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4complete all as specified and as directed. |
| 123 | Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4, complete, but except brick, i.e. using serviceable bricks obtained from Serial Item No \"15.00\" here-in-beforecomplete all as specified and as directed. |
| 124 | Plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregates) as in benchimg, copings, lintels upto 1.50 metre clear span, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, kneelers, apex stones, bed plates, kerbs etc. and in similar works including weathering, slightly rounded or chamfered angles and throating and necessary form work complete all as specified directed. |
| 125 | Precast cement concrete 1:2:4 type B-I (using 20 mm graded stone aggregate) as in cover slabs (for manholes etc.), chullah hoods, chajjas, shelves and similar articles with plain facescomplete all as specified and as directed. |
| 126 | Mild steel TMT bars 8mm dia, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90 mm,complete all as specified and as directed. |
| 127 | S&F Urinal pot large size 465 x 355 x 265 mm white (minimum) with waste pipe, stop walve and PVC connection to be installed in position supported on angles connected to the GI tubing for complete supply to watercomplete all as specified and as directed. |
| 128 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, includingfixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etccomplete all as specified and as directed. |
| 129 | Taking down distribution boards/wooden board/Metal Clad ,switch fuse units,steel enclosures for MCB of any type and removing from sitecomplete all as specified and as directed. |
| 130 | Taking down existing unserviceable submain wiring any size and making good the disturbed surfacecomplete all as specified and as directed. |
| 131 | M&L for point wiring for one light/fan/bell point controlled by a one-way switch, using 1.5 sqmm FRLS PVC insulated, sheathed, single-core multi-stranded copper conductor cable (1100V grade), drawn through rigid non-metallic PVC concealed conduit (medium grade) of suitable diameter, including 1.5 sqmm FRLS copper earth wire connected to the earth dolly. Wiring shall be terminated in pressed steel sunken boxes with a minimum wall thickness of 1.22 mm (up to 200x300 mm) or 1.63 mm (for larger sizes), complete with 3mm thick Bakelite sheet cover for mounting accessories with and including cutting chase for fixing conduite and making good to the disturbed surfaces of wall appx 3 RM for each points , complete all as specified and as directed. |
| 132 | All as per ser item No 131 hereinbefore but for one 3 pin socket outlet 5 Amp independentcomplete all as specified and as directed. |
| 133 | All as per ser item No 131 hereinbefore but for one 3 pin socket outlet 5 Amp Same board complete all as specified and as directed. |
| 134 | All as per Item no 131 here-in-before but for one15 Amp 3pin switch socket outlet, independent with 2 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 2.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire complete all as specified and as directed. |
| 135 | Supply and fix ofSwitch piano flush type single pole, one way 5 Amp ,complete all as specified and as directed. |
| 136 | Supply and fix of Switch socket out let combination universal type, 2 in 1, 2 and 3 pin 5 Amp, piano flush type, 240 volts, complete all as specified and as directed.. |
| 137 | Supply and fix of Switch socket outlet combination universal type, 2 in 1, 3 pin 5 and 15 Amp, piano flush type, 240 volts, complete all as specified and as directed. |
| 138 | Supply and fixSocketoutlet 3 pin, 5A, flush type, 240 volts,complete all as specified and as directed. |
| 139 | Electronic fan regulator stepped type,two modulewith five step 240 volts,100Watt suitable for 1200/1400 mm sweep AC ceiling fancomplete all as specified and as directed. |
| 140 | Supply and fix of Ceiling rose surface bakelite three terminals 240 voltscomplete all as specified and as directed. |
| 141 | Supply and fix of Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings , complete all as specified and as directed. |
| 142 | Supply and fix of LED lamp,6500K,900lm in white colour of 10 Watt base cap B-22 with poly carbonate difusser and aluminium heat sink , complete all as specified and as directed. |
| 143 | Supply and fixingLED light fitting 1x20 watt, 220 volts AC decorative box type with driver, holder including LED tube linghtconnecting up with three core flexible copperconductor cable suitable size from ceiing rose and taking down existing unserviceable luminaire complete all as specified and as directed. |
| 144 | S&F of LED tube light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC , 6500K colour temprature decorative type with three core flexible copper conductor cable of suitable sizecomplete all as specified and as directed. |
| 145 | S&F of recess/surface mounting LED luminaire 600x600 mm, 2x2 36Watts (warm white/cool white 4000K), 220 volts AC with high efficiency PMMA diffuser, soft glare free light complete with suitable driver, holders & including suitable LED lamp suitable for POP/Gypsum/roof ceiling including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose including cutting of false ceiling in suitable size & making good the disturbed surfaces& matching with the existing surface including making of electrical connection with & including three core flexible copper conductor cable of suitable size complete with all accessoriescomplete all as specified and as directed. |
| 146 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protectioncomplete all as specified and as directed. |
| 147 | Supply, installation, testing, and commissioning of sub-main wiring using two single-core 4 sqmm FRLS PVC insulated (unsheathed), multi-strand copper conductor cables, along with one single-core 4 sqmm FRLS PVC insulated (unsheathed), solid copper conductor cable as continuous earth wire, drawn through and including ISI-marked 25mm dia concealed PVC conduit (medium grade), complete with all necessary fittings and accessories. The work includes cutting chases, fixing conduits, pinning, restoring surfaces with 1:3 cement mortar, and making good any disturbed areas. It also includes taking down and removing old unserviceable sub-main wiring, all as specified and as directed. (From Main DB to SPN 12 Way & 8 Way). |
| 148 | Supply, installation, testing, and commissioning of sub-main wiring using two single-core 1.5 sqmm FRLS PVC insulated (unsheathed), multi-strand copper conductor cables, along with one single-core 1.5 sqmm FRLS PVC insulated (unsheathed), solid copper conductor cable as continuous earth wire, drawn through and including ISI-marked 25mm dia concealed PVC conduit (medium grade), complete with all necessary fittings and accessories. The work includes cutting chases, fixing conduits, pinning, restoring surfaces with 1:3 cement mortar, and making good any disturbed areas. It also includes taking down and removing old unserviceable sub-main wiring, complete all as specified and as directed. |
| 149 | Taking down ceiling fan & Exhaust fan and refixing the same after removing fan and blades Painting of ceiling fans complete, in situwith synthetic enamel paint by sprayingincluding filling cavities with filler, onecoat after cleaning all dust etccomplete all as specified and as directed. |
| 150 | Supply and fix of Sheet metal enclosure IP-43 double door for DBs(where MCBs arereqd) SPN 240 V, for 12 ways with suitable busbar,complete all as specified and as directed. |
| 151 | Supply and fix of Sheet metal enclosure IP-43 double door for DBs(where MCBs arereqd) SPN 240 V, for 8 ways with suitable busbar ,complete all as specified and as directed. |
| 152 | Supply and fix of Isolator SP 40 Amp, 240 voltscomplete all as specified and as directed. |
| 153 | Supply and fix of Isolator SPN-40 Amp, 240 volts 50Hz AC supply,complete all as specified and as directed. |
| 154 | Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x600mm x 6mm thick buried dirctly in ground with earth pit not lesss than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 x 6 mm earthing lead by means of nuts bolts check nuts GI washers earth wire protected by GI pipe 32 mm bore, light grade, including concrete pit in PCC (1:3:6) type C1 of size 45x45x45 cm, precast RCC (1:2:4) type B1 as cover of size 40x40x10 cm with one handle for lifting made out of 8 mm dia MS bar, GI funnel wire mesh, 20 mm bore GI pipe, medium grade, for watering, charcoal or coke and salt packed all around in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion including demolition to existing one complete all as specifed and directed. (Note :- (i) PCC pit, RCC pit cover, GI earth protection & watering pipe, funnel, earth strip upto 7.5 Mtr etc shall deemed to be included in the unit rate. (ii) GI earth strip above 7.5 m length, if required,for earthing shall be paid measured and seperately as \"Supply only\". complete all as specified and as directed. |
| 155 | Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 16Sqmm 2 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and as directed. |
| 156 | Material and labour for cutting of bituminous road / floor / culvert / PCC hard standingfor laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5meterdeep including refilling / with material and, watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thickcomplete all as specified and as directed. |
| 157 | Supply & laying dry river sand as cable cushioning 15cm thick layer before laying and 8cm thick over cable after laying the cable in trenchcomplete all as specified and as directed. |
| 158 | Supply & laying dry bricks over cable as mechanical protection layed flat with width equal to length of brick with sub class \"B\" brickscomplete all as specified and as directed. |
| 159 | Material and labourfor GI pipe \"\"medium grade\"\"for road crossing / on wall / on pole with fixed clamps, nuts, boltsfor cableprotectionof size50 mm diacomplete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail