| 1 | Excavation in trenches not exc. 1.5 M wideand not exc 1.5 M in depth and getting out in soft/loose soilfor laying pipes etc including forming bottom surface to required level complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in soft/loose soil complete all as specified and directed. |
| 3 | Removing excavated material (soil) to a distance not exc 50 M and depositingwheredirected at a level not exc 1.5 Mabove the starting point complete all as specified and directed. |
| 4 | Supply and laying75 mm outer diaCPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings, including jointed with yellow solvents cement laid in trenches complete all as specified and directed. |
| 5 | All as per item No 4 here in before, but25 mmdia of pipes complete all as specified and directed. |
| 6 | Supply and fixing 80 mm bore CPVC ball valves suitable for CPVC pipe with necessary fittingscomplete all as specified and directed. |
| 7 | All as per item No 6 here in before, but25 mmdia of pipes complete all as specified and directed. |
| 8 | Material and labour, plain cement concrete (1:3:6) type C2 using 40mm graded stone aggregate as in foundationsfilling and mass concrete complete all as specified and as directed. |
| 9 | Cutting existing road/hardstand/concrete blocks/slabs/brick work or stone masonry of any type by using crow bar chisel up to adepth of 30 cm for laying GI/CPVC pipe including making good the surface by returning filling watering ramming in layers cold mix bitumen over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 10 | Supply and fix 5000 ltr capacity rotational moulded polyethylene water storage tanks (ISI marked) (cylindrical vertical with closed top) hoisted & fixed in position complete all as specified and directed |
| 11 | Material and labour, for cross arms, bracing, supports clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size indicated or directed and inclusive of one primer coat one under coat and one finishing coat of synthetic enamel paint(Blue colour) complete all as specified and as directed. |
| 12 | Supply install and testing three phase horizontal monoblock pump(pressurisation pump) having capacity5 HP, 65mm suction and 50mm delivery fitted with CI impeller, mechanical sealed and SS shaft suitable for 15 to 20 metres head and 4.1 LPS discharge respectivelycomplete, with accessories such as base plate coupling, coupling guard, pressure pads, foundation bolts & nuts, etc complete inclusive of three phase DOL motor starter, pressure gauge, PCC foundation with necessary fittings, cabling from panel to starter and starter to motor, wiring conduitcomplete all as specified and directed.Note:- Rate includes DI/GI/CPVC fittings and fixtures for connections. |
| 13 | Supply and fixing non return butterfly valve 80 mmwith necessary fittings complete, all as specified and directed. |
| 14 | Supply and fixing butterfly valve 80 mmwith necessary fittings complete all as specified and directed. |
| 15 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4 mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified including taking down of old item complete all as specified and directed.NOTE :- Cost of GI pipe 40 mm and GI strip for length of upto 7.5 RM shall deemed to be included in the quoted rate and over and above shall be measured and paid separately. |
| 16 | Supply,installation,testing and commissioning of detectors complying with and type certified to EN - 45 addressabletype muiltisensor detectors with heat and smoke with combination complete all as specified and directed. |
| 17 | Supply,installation,testing and commissioningof addressable manual call pointre-settable type complete all as specified and directed. |
| 18 | Supply,installation,testing and commissioning addressable electronic sounder cum strobe complete all as specified and directed. |
| 19 | Supply, installation, testing and commissioningofPVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade complete all as specified and directed. |
| 20 | Material and labour for reprograming of existing fire alarm system installed at INHS Sanjivani including loope checking, adding of device location Name and Address of the roomand preparing as build drawing complete all as specified and directed. |
| 21 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 32 x 6 mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified including taking down of old item complete all as specified and directed.Note :-Cost of GI pipe 40 mm and GI strip for length of upto 7.5 RM shall deemed to be included in the quoted rate and over and above shall be measured and paid separately. |
| 22 | Supply and layingin trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 3.5 core 400 sqmmincluding necessary thimble, gland, etc andtaking down old item, complete all as specified and directed. |
| 23 | Supply and laying cables in trenches, or fixing on walls or passing through cable duct / pipe XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade having cross sectional area 2 core 6 sqmm including taking down old cable complete all as specified and directed. |
| 24 | Supply,install, testing and commissioning ofindoor type panel board,dust and vermin proofhaving suitable widthwith 2 mm thick CRCA sheetenclosure powder coated, all necessary frame work ,IP-54 protection including aluminum bus bar of approx minimum 1600 ampsincluding electrical interlocking of two incomer ACBs and with sufficient space duly laminated with PVC sleeves with colour coding, plate for fixing ACB/MCCB\"s, cover plate for covering ACB/MCCB\"s with openings for ACB/MCCB\"s knobsincludingfront and back open, providing necessary tower bolt as required. The cabinet and all accessories should be chemically treated with nine panel process. The panel should be suitablefor 415 Volts, 50 Hz, 3 phase 4 wire system, CTs, sliding fuse, control cable / wire, etc as requiredand internal connection should be suitablefor 415 V, 50 Hz, 3 phase 4 wire system, CTs, sliding fuse, control cable / wire, etc as requiredand internal connection should be pre-wired with suitable size of power cable / control cable / copper solid wire/strip for instrument/protecting devices, all metersthimble for cable connection and comprising the following itemsduly connected with other electrical acessories and marking of all Incoming/outgoing feeders for identification of feeders by sticker letters or writing by paint including electrical connection of all inciming / outgoing cables as directed by Engr-in-charge including necessary foundation with MC75 andwith PCC 1:2:4 type B-4 (using 40 mm graded aggregate) etc complete all as specified and directed.. The panel shall comprises of the following:- |
| 25 | INCOMING :- (a) From transformer, ACB, 4 pole, EDO, 1250 Amp, 50 kA, microprocessor based,415 volt AC at 50 Hz with inbuilt 7NO+7NC aux contact, safety shutter assembly, racking handle, door sealing frame, push butten cover = 01 No, (b) Digital ACLED multifunction meter, 3 phase, class 0.5, Model \"A\",with built in selector switch, RS485 port= Each 01, (c) MCBs of suitable rating, (d) LED indicator Red,Yellow, Pilot lamp,220Volt,50HZ - 01 Set (set of two) , = Set 01, (e) LED indicator bluePilot lamp,220Volt,50HZ= Each 01 Note:-All LT breakers should be of single make for this project.OUTGOING : - (a) MCCB400 AMP 36KA 4 pole(adj thermal magnetic release) 415 volt AC at 50 Hz= Each 02 Nos (b) MCCB250 AMP 36KA 4 pole(thermal magnetic release) 415 volt AC at 50 Hz= Each 01 Nos(c) MCCB 63 Amp 36 KA 4 pole = Each 01 No(d) MCCB 32 Amp 36 KA 4 pole = Each 02 No |
| 26 | Material and labour for riddled soil cushioning and covering of UG cables in trenches complete all as specified and directed.Note :-Punned thicknessshall be measuredand paid for measurement purpose only. |
| 27 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size250 mm x 150 mm x 40 mm. laid in trenches for protectionofcable complete all as specified and directed. |
| 28 | Material and labour for earth continuity conductor or main earthing strip fixed to wall on batten or porcelain insulators or recess or chases or buried in ground or drawn inGI pipe 40 mm or fixed with poles or any other indicated sitution for loop earthing etc as required using galvanised iron strip of size 32 X 6 mm complete all as specified and directed.Note :- GI Pipe 40 mm shall be measured and paid separately |
| 29 | Material and labour for 40 mmboreMS tubes light grade galvanised, with all fittingslaid in trenches or walls or for passing earth strip, etc ,including taking down old item complete all as specified and directed. |